2609 lines
117 KiB
YAML
2609 lines
117 KiB
YAML
zabbix_export:
|
|
version: '7.0'
|
|
template_groups:
|
|
- uuid: e960332b3f6c46a1956486d4f3f99fce
|
|
name: 'Templates/Server hardware'
|
|
templates:
|
|
- uuid: fc834b8da8864678b55557e9a237eac9
|
|
template: 'DELL PowerEdge R840 by SNMP'
|
|
name: 'DELL PowerEdge R840 by SNMP'
|
|
description: |
|
|
Template for DELL PowerEdge R840 servers with iDRAC version 7 and later.
|
|
|
|
MIBs used:
|
|
HOST-RESOURCES-MIB
|
|
IDRAC-MIB-SMIv2
|
|
SNMPv2-MIB
|
|
|
|
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates
|
|
|
|
Generated by official Zabbix template tool "Templator"
|
|
vendor:
|
|
name: Zabbix
|
|
version: 7.0-5
|
|
groups:
|
|
- name: 'Templates/Server hardware'
|
|
items:
|
|
- uuid: 7f08a9bf1d5540f0b05040d16d67d87a
|
|
name: 'SNMP walk RAID controllers table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]'
|
|
key: dell.server.array.controller.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: 39d26209dd3242c5ad90380b566c01aa
|
|
name: 'SNMP walk Battery table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]'
|
|
key: dell.server.battery.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: 077c58fdb06c4191bf8f194b4c9108e7
|
|
name: 'BIOS version'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]'
|
|
key: dell.server.bios.version
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the version name of the system BIOS.
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 65da5f84a8bb43da8b72ddbe6d757fa8
|
|
name: 'System contact details'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
|
|
key: 'dell.server.contact[sysContact]'
|
|
delay: 1h
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
Name and contact information of the contact person for the node. If not provided, the value is a zero-length string.
|
|
inventory_link: CONTACT
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 1d
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 94bcc2449dfa4bb59fd778ba96e3abdf
|
|
name: 'SNMP walk Processor device tables'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]'
|
|
key: dell.server.cpu.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: 51c9b68b617c498eb612807734076367
|
|
name: 'System description'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
|
|
key: 'dell.server.descr[sysDescr]'
|
|
delay: 1h
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software.
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 1d
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: c888185c08f84b059fdbf7ff0fa8eb6a
|
|
name: 'SNMP walk Physical disk table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]'
|
|
key: dell.server.disk.physical.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: f141e6e279fe4b3db65bbfe7e559389b
|
|
name: 'SNMP walk Virtual disk table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]'
|
|
key: dell.server.disk.virtual.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: d7e317cd293c4d8fa39f4283b79de6e4
|
|
name: 'SNMP walk Cooling device table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]'
|
|
key: dell.server.fan.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: 09e33063d84e486fb4964af35916cc25
|
|
name: 'Firmware version'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]'
|
|
key: 'dell.server.hw.firmware[racFirmwareVersion]'
|
|
delay: 1h
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the firmware version of a remote access card.
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 1d
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
triggers:
|
|
- uuid: 26f924a3a9e1470891cb0d9e9136ad9d
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0'
|
|
name: 'Dell R840: Firmware has changed'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: INFO
|
|
description: 'Firmware version has changed. Acknowledge to close the problem manually.'
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
- uuid: b34415ae1ac84375834612f402d4ea0c
|
|
name: 'Hardware model name'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]'
|
|
key: 'dell.server.hw.model[systemModelName]'
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the model name of the system.
|
|
inventory_link: MODEL
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: b46ad39d968141259ace337d70744001
|
|
name: 'Hardware serial number'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]'
|
|
key: 'dell.server.hw.serialnumber[systemServiceTag]'
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the service tag of the system.
|
|
inventory_link: SERIALNO_A
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
triggers:
|
|
- uuid: 8d1e926bb5f640b4bf8c8342b5cf1d56
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0'
|
|
name: 'Dell R840: Device has been replaced'
|
|
event_name: 'Dell R840: Device has been replaced (new serial number received)'
|
|
priority: INFO
|
|
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
- uuid: afa223e9d16b41deaac482b8328ba0e4
|
|
name: 'Uptime (hardware)'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]'
|
|
key: 'dell.server.hw.uptime[systemPowerUpTime]'
|
|
trends: '0'
|
|
units: uptime
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the power-up time of the system in seconds.
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 0445a9767ce34fb7b2be072609504011
|
|
name: 'System location'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
|
|
key: 'dell.server.location[sysLocation]'
|
|
delay: 15m
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string.
|
|
inventory_link: LOCATION
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: c84cc87d95664f66a674eefec258841a
|
|
name: 'Memory, total size'
|
|
type: CALCULATED
|
|
key: dell.server.memory.size.total
|
|
units: B
|
|
params: 'sum(last_foreach(//dell.server.memory.size[*]))'
|
|
description: 'Total memory amount on the device.'
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: component
|
|
value: memory
|
|
triggers:
|
|
- uuid: c44165ebea1346c78970c1f8d96da0be
|
|
expression: 'change(/DELL PowerEdge R840 by SNMP/dell.server.memory.size.total)>0'
|
|
name: 'Dell R840: Memory amount has changed'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 6ad434d7873f4c9e846ebaefa3e3640c
|
|
name: 'SNMP walk Memory device table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]'
|
|
key: dell.server.memory.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: 58be11401c084b0a81ebadbde199133d
|
|
name: 'System name'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
|
|
key: 'dell.server.name[sysName]'
|
|
delay: 15m
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string.
|
|
inventory_link: NAME
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
triggers:
|
|
- uuid: 673eda315d9b4dfcb15509fa01fffac2
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName]))>0'
|
|
name: 'Dell R840: System name has changed'
|
|
event_name: 'Dell R840: System name has changed (new name: {ITEM.VALUE})'
|
|
priority: INFO
|
|
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
- uuid: 73802978c64b4d978b6e06ede9f5d760
|
|
name: 'SNMP walk Network device table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]'
|
|
key: dell.server.net.if.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: 49473f26fedb459c9642704bae33adb1
|
|
name: 'Uptime (network)'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]'
|
|
key: 'dell.server.net.uptime[snmpEngineTime]'
|
|
trends: '0'
|
|
units: uptime
|
|
description: |
|
|
MIB: SNMP-FRAMEWORK-MIB
|
|
The number of seconds since the value of the snmpEngineBoots object last changed.
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 808a099b33c6438e8fd91a4f29c41f35
|
|
name: 'System object ID'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
|
|
key: 'dell.server.objectid[sysObjectID]'
|
|
delay: 15m
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1).
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 0b013a35762f4bdab3ffeec58176779a
|
|
name: 'SNMP walk Power supply table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]'
|
|
key: dell.server.psu.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: c2ab8a025fb34e878f7bbea9db51dbea
|
|
name: 'SNMP walk Temperature sensor table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]'
|
|
key: dell.server.sensor.temp.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: 42be6e0b9fbe46179597650622a2241a
|
|
name: 'Overall system health status'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]'
|
|
key: 'dell.server.status[globalSystemStatus]'
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: component
|
|
value: health
|
|
- tag: component
|
|
value: system
|
|
triggers:
|
|
- uuid: c3e8fd8fd0d0406d8c2d9a2c45eeecee
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}'
|
|
name: 'Dell R840: System is in unrecoverable state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'Please check the device for faults.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 4b32809fad0e468bb5f1bd09c7078def
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
|
|
name: 'Dell R840: System status is in critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the device for errors.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: a75745134dad4592a23c43ca77975d95
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}'
|
|
name: 'Dell R840: System status is in warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the device for warnings.'
|
|
dependencies:
|
|
- name: 'Dell R840: System status is in critical state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 8d967ad6ac2b46c28072f713cd11b59f
|
|
name: 'Operating system'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]'
|
|
key: 'dell.server.sw.os[systemOSName]'
|
|
delay: 1h
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the name of the operating system that the host is running.
|
|
inventory_link: OS
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 1d
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
triggers:
|
|
- uuid: 4096c84c616743bfbfca9707e43a3db3
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName]))>0'
|
|
name: 'Dell R840: Operating system description has changed'
|
|
priority: INFO
|
|
description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.'
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
- uuid: f1068ce5a40b45ba9388e17f6dce3b79
|
|
name: 'SNMP walk System battery table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]'
|
|
key: dell.server.system.battery.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: b5c04f5439244a87991b2b053b5f8f9b
|
|
name: 'SNMP walk Voltage probe table'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]'
|
|
key: dell.server.voltage.walk
|
|
history: '0'
|
|
value_type: TEXT
|
|
trends: '0'
|
|
description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.'
|
|
tags:
|
|
- tag: component
|
|
value: raw
|
|
- uuid: 074f6d9a11814bb7909d99664192421d
|
|
name: 'SNMP traps (fallback)'
|
|
type: SNMP_TRAP
|
|
key: snmptrap.fallback
|
|
delay: '0'
|
|
value_type: LOG
|
|
trends: '0'
|
|
description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items'
|
|
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
|
|
tags:
|
|
- tag: component
|
|
value: network
|
|
- uuid: b690c870c11c40ecbd162a01e82abbfe
|
|
name: 'SNMP agent availability'
|
|
type: INTERNAL
|
|
key: 'zabbix[host,snmp,available]'
|
|
description: |
|
|
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
|
|
Possible values:
|
|
0 - not available
|
|
1 - available
|
|
2 - unknown
|
|
valuemap:
|
|
name: zabbix.host.available
|
|
tags:
|
|
- tag: component
|
|
value: health
|
|
- tag: component
|
|
value: system
|
|
triggers:
|
|
- uuid: 6f00331597c0443a93c182a86040cca4
|
|
expression: 'max(/DELL PowerEdge R840 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0'
|
|
name: 'Dell R840: No SNMP data collection'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
discovery_rules:
|
|
- uuid: 23349a5dacb34beda5c745461fd2b2a9
|
|
name: 'Array controller discovery'
|
|
type: DEPENDENT
|
|
key: array.discovery
|
|
delay: '0'
|
|
description: 'Array controller discovery.'
|
|
item_prototypes:
|
|
- uuid: 9afa1fe4ec6343db9abdb7b1a6c57b10
|
|
name: 'Controller [{#CNTLR_NAME}]: Model'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The controller's name as represented in Storage Management.
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.array.controller.walk
|
|
tags:
|
|
- tag: component
|
|
value: diskarray
|
|
- tag: component
|
|
value: storage
|
|
- uuid: 3af6572ca94d49da8b6c59185ddeb744
|
|
name: 'Controller [{#CNTLR_NAME}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The status of the controller itself without the propagation of any contained component status.
|
|
Possible values:
|
|
1: Other
|
|
2: Unknown
|
|
3: OK
|
|
4: Non-critical
|
|
5: Critical
|
|
6: Non-recoverable
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.array.controller.walk
|
|
tags:
|
|
- tag: component
|
|
value: diskarray
|
|
- tag: component
|
|
value: storage
|
|
trigger_prototypes:
|
|
- uuid: 149de042930a444d82d1a8016efaea2c
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
|
|
name: 'Dell R840: Controller [{#CNTLR_NAME}]: Critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the device for faults.'
|
|
dependencies:
|
|
- name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 2fb2ddb749ed450da886420fdc5da394
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
|
|
name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'Please check the device for faults.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: b8cbc4a8cc404bcc83bf24af56997432
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
|
|
name: 'Dell R840: Controller [{#CNTLR_NAME}]: Warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the device for faults.'
|
|
dependencies:
|
|
- name: 'Dell R840: Controller [{#CNTLR_NAME}]: Critical state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
|
|
- name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
master_item:
|
|
key: dell.server.array.controller.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#SNMPVALUE}'
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38
|
|
- '0'
|
|
- '{#CNTLR_NAME}'
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79
|
|
- '0'
|
|
error_handler: DISCARD_VALUE
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: 3f6ece6fbaae461bbb01f7adaeca9756
|
|
name: 'Battery discovery'
|
|
type: DEPENDENT
|
|
key: battery.discovery
|
|
delay: '0'
|
|
description: 'Battery discovery.'
|
|
item_prototypes:
|
|
- uuid: 9f78de09167d4de9b7c5f8606d8f9bb2
|
|
name: 'Battery [{#BATTERY_NAME}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
Current state of battery.
|
|
Possible values:
|
|
1: The current state could not be determined.
|
|
2: The battery is operating normally.
|
|
3: The battery has failed and needs to be replaced.
|
|
4: The battery temperature is high or charge level is depleting.
|
|
5: The battery is missing or not detected.
|
|
6: The battery is undergoing the re-charge phase.
|
|
7: The battery voltage or charge level is below the threshold.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::batteryState'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.battery.walk
|
|
tags:
|
|
- tag: component
|
|
value: battery
|
|
- tag: component
|
|
value: diskarray
|
|
trigger_prototypes:
|
|
- uuid: 3624b95de99c42ac948402a4ca13a616
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
|
|
name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the device for faults.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 560fd4dcbf4a4ee8b49ad8880b767591
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
|
|
name: 'Dell R840: Battery [{#BATTERY_NAME}]: Not in optimal state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: INFO
|
|
description: 'Please check the device for faults.'
|
|
dependencies:
|
|
- name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
|
|
- name: 'Dell R840: Battery [{#BATTERY_NAME}]: Warning state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: dc5c489632c54cf3a393cc78e50020db
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
|
|
name: 'Dell R840: Battery [{#BATTERY_NAME}]: Warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the device for faults.'
|
|
dependencies:
|
|
- name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
master_item:
|
|
key: dell.server.battery.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#BATTERY_NUM}'
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1
|
|
- '0'
|
|
- '{#BATTERY_NAME}'
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21
|
|
- '0'
|
|
error_handler: DISCARD_VALUE
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: 3bcf2e1613ce4bcf82c8154dfa5dc7c8
|
|
name: 'CPU status discovery'
|
|
type: DEPENDENT
|
|
key: cpu.discovery
|
|
delay: '0'
|
|
description: 'CPU status discovery.'
|
|
item_prototypes:
|
|
- uuid: b5bc4152569c4d94ac18af051ac53545
|
|
name: 'CPU [{#CPU_FQDD}]: State'
|
|
type: DEPENDENT
|
|
key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
description: 'This attribute defines the reading of the processor device status probe.'
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.cpu.walk
|
|
tags:
|
|
- tag: component
|
|
value: cpu
|
|
trigger_prototypes:
|
|
- uuid: 723b859cb5a94d339c7d0cba9ad2dc8d
|
|
expression: 'bitand(last(/DELL PowerEdge R840 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0'
|
|
name: 'Dell R840: CPU [{#CPU_FQDD}]: Reading error'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
CPU probe reading flag is not `processorPresent`.
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 417e257e354542aa84741c435b7fe916
|
|
name: 'CPU [{#CPU_FQDD}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.'
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.cpu.walk
|
|
tags:
|
|
- tag: component
|
|
value: cpu
|
|
trigger_prototypes:
|
|
- uuid: 66665f584f9a43c192cf995a4ef89f09
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3'
|
|
name: 'Dell R840: CPU [{#CPU_FQDD}]: Status is not OK'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
CPU status is not OK.
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
master_item:
|
|
key: dell.server.cpu.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#CPU_FQDD}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: 91a882b4c4fe48ac9224fdfb811bcf71
|
|
name: 'Fan discovery'
|
|
type: DEPENDENT
|
|
key: fan.discovery
|
|
delay: '0'
|
|
filter:
|
|
conditions:
|
|
- macro: '{#TYPE}'
|
|
value: '3'
|
|
formulaid: A
|
|
description: 'Fan discovery.'
|
|
item_prototypes:
|
|
- uuid: 8ee74a624afc41d0b607da978b2b0858
|
|
name: 'Fan [{#FAN_DESCR}]: Speed'
|
|
type: DEPENDENT
|
|
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
|
|
delay: '0'
|
|
units: rpm
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`.
|
|
When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device.
|
|
When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute.
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}'
|
|
- '0'
|
|
master_item:
|
|
key: dell.server.fan.walk
|
|
tags:
|
|
- tag: component
|
|
value: fan
|
|
- uuid: 40ffe2dbed764fab8f76ab3d77c4d48b
|
|
name: 'Fan [{#FAN_DESCR}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the probe status of the cooling device.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.fan.walk
|
|
tags:
|
|
- tag: component
|
|
value: fan
|
|
trigger_prototypes:
|
|
- uuid: 4c81607b448445b7859af43eefda9c88
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
|
|
name: 'Dell R840: Fan [{#FAN_DESCR}]: Critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the fan unit.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 9c23542532ca4414948cfaf5fb7976d2
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
|
|
name: 'Dell R840: Fan [{#FAN_DESCR}]: Warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the fan unit.'
|
|
dependencies:
|
|
- name: 'Dell R840: Fan [{#FAN_DESCR}]: Critical state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
graph_prototypes:
|
|
- uuid: 3ca078011770494280453bce2c2198fe
|
|
name: 'Dell R840: Fan [{#FAN_DESCR}]: Speed'
|
|
graph_items:
|
|
- color: 199C0D
|
|
item:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
|
|
master_item:
|
|
key: dell.server.fan.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#SNMPVALUE}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.5
|
|
- '0'
|
|
- '{#FAN_DESCR}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.8
|
|
- '0'
|
|
- '{#TYPE}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.7
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: ab7d2361eeb946a48bb557e9dbc8904c
|
|
name: 'Memory discovery'
|
|
type: DEPENDENT
|
|
key: memory.discovery
|
|
delay: '0'
|
|
description: 'Memory discovery.'
|
|
item_prototypes:
|
|
- uuid: 0c87c1f952484471afad86f77c13073a
|
|
name: 'Memory [{#SNMPVALUE}]: Size'
|
|
type: DEPENDENT
|
|
key: 'dell.server.memory.size[{#SNMPVALUE}]'
|
|
delay: '0'
|
|
units: B
|
|
description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '1024'
|
|
master_item:
|
|
key: dell.server.memory.walk
|
|
tags:
|
|
- tag: component
|
|
value: memory
|
|
- uuid: 2dab90151d1144fda74204e88c10067b
|
|
name: 'Memory [{#SNMPVALUE}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.memory.status[{#SNMPVALUE}]'
|
|
delay: '0'
|
|
description: 'This attribute defines the status of the memory device.'
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.memory.walk
|
|
tags:
|
|
- tag: component
|
|
value: memory
|
|
trigger_prototypes:
|
|
- uuid: 9ef225ff91114afdba9ee315c09a53c8
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3'
|
|
name: 'Dell R840: Memory [{#SNMPVALUE}]: Status is not OK'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
Memory status is not OK.
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
master_item:
|
|
key: dell.server.memory.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#SNMPVALUE}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: 507b67db9d33407ab04b5b26eee17f33
|
|
name: 'Network interface discovery'
|
|
type: DEPENDENT
|
|
key: net.if.discovery
|
|
delay: '0'
|
|
description: 'Discovery of network interfaces.'
|
|
item_prototypes:
|
|
- uuid: 3400e8c414144a88baed85ccd1179008
|
|
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.net.if.link[{#NIC_FQDD}]'
|
|
delay: '0'
|
|
description: 'This attribute defines the connection status of the network device.'
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.net.if.walk
|
|
tags:
|
|
- tag: component
|
|
value: network
|
|
trigger_prototypes:
|
|
- uuid: 1fe39881ec004b87a41c1d8d44479981
|
|
expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0'
|
|
name: 'Dell R840: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: |
|
|
This trigger expression works as follows:
|
|
1. It can be triggered if the operations status is Down.
|
|
2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down.
|
|
3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.)
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 1e3ec0d9d8284aed8edeff4490afe605
|
|
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.net.if.status[{#NIC_FQDD}]'
|
|
delay: '0'
|
|
description: 'This attribute defines the status of the network device.'
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.net.if.walk
|
|
tags:
|
|
- tag: component
|
|
value: network
|
|
trigger_prototypes:
|
|
- uuid: 5196e2886545427dbafe649cb3cd651f
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3'
|
|
name: 'Dell R840: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
Network interface status is not OK.
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
master_item:
|
|
key: dell.server.net.if.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#NIC_FQDD}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1
|
|
- '0'
|
|
- '{#NIC_MAC}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1
|
|
- '2'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: d9c26b4a06bc45acb742315896b358da
|
|
name: 'Physical disk discovery'
|
|
type: DEPENDENT
|
|
key: physicaldisk.discovery
|
|
delay: '0'
|
|
description: 'Physical disk discovery.'
|
|
item_prototypes:
|
|
- uuid: be048b1285ba4a21a14e5f79727c2b91
|
|
name: 'Physical disk [{#DISK_NAME}]: Media type'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The media type of the physical disk. Possible Values:
|
|
1: The media type could not be determined.
|
|
2: Hard Disk Drive (HDD).
|
|
3: Solid State Drive (SSD).
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.physical.walk
|
|
tags:
|
|
- tag: component
|
|
value: physicaldisk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: 79fa0faedeb743c1a9f9c0ea0d454935
|
|
name: 'Physical disk [{#DISK_NAME}]: Model name'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The model number of the physical disk.
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.physical.walk
|
|
tags:
|
|
- tag: component
|
|
value: physicaldisk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: b2668345145f4d638dbb364afbdfb9f8
|
|
name: 'Physical disk [{#DISK_NAME}]: Serial number'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The physical disk's unique identification number from the manufacturer.
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.physical.walk
|
|
tags:
|
|
- tag: component
|
|
value: physicaldisk
|
|
- tag: component
|
|
value: storage
|
|
trigger_prototypes:
|
|
- uuid: 7d2a1a115b304ca5823618360675d43d
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0'
|
|
name: 'Dell R840: Physical disk [{#DISK_NAME}] has been replaced'
|
|
event_name: 'Dell R840: [{#DISK_NAME}] has been replaced (new serial number received)'
|
|
priority: INFO
|
|
description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.'
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
- uuid: 6e50bc2fa3ee4ceeb8fe044a7d83f836
|
|
name: 'Physical disk [{#DISK_NAME}]: Size'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
units: B
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The size of the physical disk in megabytes.
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '1048576'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.physical.walk
|
|
tags:
|
|
- tag: component
|
|
value: physicaldisk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: 3a2cd6a4c4ea4a3ab4ccbd555ee17f5b
|
|
name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
Indicates whether the physical disk has received a predictive failure alert.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::BooleanType'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.physical.walk
|
|
tags:
|
|
- tag: component
|
|
value: physicaldisk
|
|
- tag: component
|
|
value: storage
|
|
trigger_prototypes:
|
|
- uuid: 3a648ce450cd4236bcda1b48f6cb840f
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}'
|
|
name: 'Dell R840: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'Disk probably requires replacement.'
|
|
dependencies:
|
|
- name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: fbb5d836a0c344e0929bb406cf9721ee
|
|
name: 'Physical disk [{#DISK_NAME}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The status of the physical disk itself without the propagation of any contained component status.
|
|
Possible values:
|
|
1: Other
|
|
2: Unknown
|
|
3: OK
|
|
4: Non-critical
|
|
5: Critical
|
|
6: Non-recoverable
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.physical.walk
|
|
tags:
|
|
- tag: component
|
|
value: physicaldisk
|
|
- tag: component
|
|
value: storage
|
|
trigger_prototypes:
|
|
- uuid: 426d1d50afb04253b92a5b99c9e96206
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
|
|
name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'Please check physical disk for warnings or errors.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 1d0a3f13c2fd4bc8be2c4305850c984c
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
|
|
name: 'Dell R840: Physical disk [{#DISK_NAME}]: Warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check physical disk for warnings or errors.'
|
|
dependencies:
|
|
- name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
graph_prototypes:
|
|
- uuid: 2b64a7034bb3455196e2716e622ce404
|
|
name: 'Dell R840: Physical disk [{#DISK_NAME}]: Size'
|
|
graph_items:
|
|
- color: 199C0D
|
|
item:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
|
|
master_item:
|
|
key: dell.server.disk.physical.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#SNMPVALUE}'
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1
|
|
- '0'
|
|
- '{#DISK_NAME}'
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2
|
|
- '0'
|
|
error_handler: DISCARD_VALUE
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: d95e02ed8c204fe1b4edf5a3d3ad3847
|
|
name: 'PSU discovery'
|
|
type: DEPENDENT
|
|
key: psu.discovery
|
|
delay: '0'
|
|
description: 'PSU discovery.'
|
|
item_prototypes:
|
|
- uuid: fe99911125c54800be75e332c150356b
|
|
name: 'Power supply [{#PSU_DESCR}]: State'
|
|
type: DEPENDENT
|
|
key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the status of the power supply.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.psu.walk
|
|
tags:
|
|
- tag: component
|
|
value: psu
|
|
trigger_prototypes:
|
|
- uuid: 519b5f4f8c6f4b6b92eafb910c1e81eb
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
|
|
name: 'Dell R840: Power supply [{#PSU_DESCR}]: Critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the power supply unit for errors.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 76ab0ba99e424e43b686d11049b40258
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
|
|
name: 'Dell R840: Power supply [{#PSU_DESCR}]: Warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the power supply unit for errors.'
|
|
dependencies:
|
|
- name: 'Dell R840: Power supply [{#PSU_DESCR}]: Critical state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
master_item:
|
|
key: dell.server.psu.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#SNMPVALUE}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
|
|
- '0'
|
|
- '{#PSU_DESCR}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: 1461820b857d483e9988434b36a9cf6f
|
|
name: 'System battery discovery'
|
|
type: DEPENDENT
|
|
key: system.battery.discovery
|
|
delay: '0'
|
|
description: 'System battery discovery.'
|
|
item_prototypes:
|
|
- uuid: b4c42aaf69b34fcaa8ff8a23f0767c3a
|
|
name: 'System battery [{#SNMPVALUE}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.system.battery[{#SNMPVALUE}]'
|
|
delay: '0'
|
|
description: 'This attribute defines the status of the battery.'
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.system.battery.walk
|
|
tags:
|
|
- tag: component
|
|
value: battery
|
|
trigger_prototypes:
|
|
- uuid: 9cc273d913d04f58af291d888fd942ff
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3'
|
|
name: 'Dell R840: System battery [{#SNMPVALUE}]: Status is not OK'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
System battery status is not OK.
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
master_item:
|
|
key: dell.server.system.battery.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#SNMPVALUE}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: e9897a4e0d9d41e38e1cfd198f94d2de
|
|
name: 'Temperature discovery'
|
|
type: DEPENDENT
|
|
key: temp.discovery
|
|
delay: '0'
|
|
description: 'Temperature sensor discovery.'
|
|
item_prototypes:
|
|
- uuid: c76c966651f940a5ac664c75c88ca689
|
|
name: 'Probe [{#SENSOR_LOCALE}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
value_type: FLOAT
|
|
trends: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the probe status of the temperature probe.
|
|
Possible values:
|
|
other(1), -- probe status is not one of the following:
|
|
unknown(2), -- probe status is unknown (not known or monitored)
|
|
ok(3), -- probe is reporting a value within the thresholds
|
|
nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold
|
|
criticalUpper(5), -- probe has crossed the upper critical threshold
|
|
nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold
|
|
nonCriticalLower(7), -- probe has crossed the lower noncritical threshold
|
|
criticalLower(8), -- probe has crossed the lower critical threshold
|
|
nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold
|
|
failed(10) -- probe is not functional
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.sensor.temp.walk
|
|
tags:
|
|
- tag: component
|
|
value: temperature
|
|
trigger_prototypes:
|
|
- uuid: d1e14d635c0945298c5319380f8ac2f9
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
|
|
name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the device for faults.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 567f74a71047410c9dcb8d70298160b1
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
|
|
name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Not in optimal status'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: INFO
|
|
description: 'Please check the device for faults.'
|
|
manual_close: 'YES'
|
|
dependencies:
|
|
- name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
|
|
- name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Warning status'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
- uuid: da4cdf74306947e7a6d394cca92c8c70
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
|
|
name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Warning status'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the device for faults.'
|
|
dependencies:
|
|
- name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: e498e0b6adca49048b27fcde07880661
|
|
name: 'Probe [{#SENSOR_LOCALE}]: Value'
|
|
type: DEPENDENT
|
|
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
value_type: FLOAT
|
|
units: °C
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`.
|
|
When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade.
|
|
When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute.
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '0.1'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.sensor.temp.walk
|
|
tags:
|
|
- tag: component
|
|
value: temperature
|
|
graph_prototypes:
|
|
- uuid: aec83bed731d402a841088d092bd6400
|
|
name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Value'
|
|
graph_items:
|
|
- color: 199C0D
|
|
item:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
|
|
master_item:
|
|
key: dell.server.sensor.temp.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#SNMPVALUE}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
|
|
- '0'
|
|
- '{#SENSOR_LOCALE}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: 9e2d2bc270704e8eb646b55a7f4e377e
|
|
name: 'Virtual disk discovery'
|
|
type: DEPENDENT
|
|
key: virtualdisk.discovery
|
|
delay: '0'
|
|
description: 'Virtual disk discovery.'
|
|
item_prototypes:
|
|
- uuid: 27bb804aa7df49ddbc410b268db63218
|
|
name: 'Virtual disk [{#DISK_NAME}]: Layout type'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The virtual disk's RAID type.
|
|
Possible values:
|
|
1: Not one of the following
|
|
2: RAID-0
|
|
3: RAID-1
|
|
4: RAID-5
|
|
5: RAID-6
|
|
6: RAID-10
|
|
7: RAID-50
|
|
8: RAID-60
|
|
9: Concatenated RAID 1
|
|
10: Concatenated RAID 5
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.virtual.walk
|
|
tags:
|
|
- tag: component
|
|
value: storage
|
|
- tag: component
|
|
value: virtualdisk
|
|
- uuid: 109cd4fc0cc24a6586a282272b8448bb
|
|
name: 'Virtual disk [{#DISK_NAME}]: Read policy'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The read policy used by the controller for read operations on this virtual disk.
|
|
Possible values:
|
|
1: No Read Ahead.
|
|
2: Read Ahead.
|
|
3: Adaptive Read Ahead.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 1h
|
|
master_item:
|
|
key: dell.server.disk.virtual.walk
|
|
tags:
|
|
- tag: component
|
|
value: storage
|
|
- tag: component
|
|
value: virtualdisk
|
|
- uuid: e4868bd552d34f79823d3c7518babad8
|
|
name: 'Virtual disk [{#DISK_NAME}]: Size'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
trends: '0'
|
|
units: B
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The size of the virtual disk in megabytes.
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '1048576'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.virtual.walk
|
|
tags:
|
|
- tag: component
|
|
value: storage
|
|
- tag: component
|
|
value: virtualdisk
|
|
- uuid: cf12e14b376940189873430fdfa64c49
|
|
name: 'Virtual disk [{#DISK_NAME}]: Operational state'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The state of the virtual disk when there are progressive operations ongoing.
|
|
Possible values:
|
|
1: There is no active operation running.
|
|
2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.
|
|
3: A Consistency Check (CC) is being performed on the virtual disk.
|
|
4: The virtual disk is being initialized.
|
|
5: BackGround Initialization (BGI) is being performed on the virtual disk.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 3m
|
|
master_item:
|
|
key: dell.server.disk.virtual.walk
|
|
tags:
|
|
- tag: component
|
|
value: storage
|
|
- tag: component
|
|
value: virtualdisk
|
|
- uuid: 344be656d8d84bbca28853d240f5953f
|
|
name: 'Virtual disk [{#DISK_NAME}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The current state of this virtual disk (which includes any member physical disks.)
|
|
Possible states:
|
|
1: The current state could not be determined.
|
|
2: The virtual disk is operating normally or optimally.
|
|
3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost.
|
|
4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.
|
|
The data on the virtual disk might no longer be fault tolerant.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
master_item:
|
|
key: dell.server.disk.virtual.walk
|
|
tags:
|
|
- tag: component
|
|
value: storage
|
|
- tag: component
|
|
value: virtualdisk
|
|
trigger_prototypes:
|
|
- uuid: 443b942a8ea64600a6b1bdda2bb75ec3
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
|
|
name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Failed state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'Please check the virtual disk for warnings or errors.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: be479b50bc2c4320afff5eef0292bc88
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
|
|
name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the virtual disk for warnings or errors.'
|
|
dependencies:
|
|
- name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Failed state'
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: db4f2a2abead4efba3d54124b2e992f7
|
|
name: 'Virtual disk [{#DISK_NAME}]: Write policy'
|
|
type: DEPENDENT
|
|
key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]'
|
|
delay: '0'
|
|
description: |
|
|
MIB: IDRAC-MIB-SMIv2
|
|
The write policy used by the controller for write operations on this virtual disk.
|
|
Possible values:
|
|
1: Write Through.
|
|
2: Write Back.
|
|
3: Force Write Back.
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 1h
|
|
master_item:
|
|
key: dell.server.disk.virtual.walk
|
|
tags:
|
|
- tag: component
|
|
value: storage
|
|
- tag: component
|
|
value: virtualdisk
|
|
graph_prototypes:
|
|
- uuid: 630725a2e858465ba6c3a6b5b8982d93
|
|
name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Size'
|
|
graph_items:
|
|
- color: 199C0D
|
|
item:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
|
|
master_item:
|
|
key: dell.server.disk.virtual.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#SNMPVALUE}'
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1
|
|
- '0'
|
|
- '{#DISK_NAME}'
|
|
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2
|
|
- '0'
|
|
error_handler: DISCARD_VALUE
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
- uuid: 43169b68868240d589e8c87bba94ce86
|
|
name: 'Voltage probe discovery'
|
|
type: DEPENDENT
|
|
key: voltage.discovery
|
|
delay: '0'
|
|
filter:
|
|
evaltype: AND
|
|
conditions:
|
|
- macro: '{#VPROBE_NAME}'
|
|
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
|
|
formulaid: A
|
|
- macro: '{#VPROBE_NAME}'
|
|
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
|
|
operator: NOT_MATCHES_REGEX
|
|
formulaid: B
|
|
- macro: '{#VPROBE_TYPE}'
|
|
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
|
|
formulaid: C
|
|
- macro: '{#VPROBE_TYPE}'
|
|
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
|
|
operator: NOT_MATCHES_REGEX
|
|
formulaid: D
|
|
description: 'Voltage probe discovery.'
|
|
item_prototypes:
|
|
- uuid: d8a499c3a77741d39e4108469009f9b0
|
|
name: 'Voltage probe [{#VPROBE_NAME}]: Status'
|
|
type: DEPENDENT
|
|
key: 'dell.server.voltage.status[{#VPROBE_NAME}]'
|
|
delay: '0'
|
|
description: 'This attribute defines the status of the voltage probe.'
|
|
valuemap:
|
|
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}'
|
|
- '0'
|
|
master_item:
|
|
key: dell.server.voltage.walk
|
|
tags:
|
|
- tag: component
|
|
value: voltage
|
|
trigger_prototypes:
|
|
- uuid: 74ee37bcbbcc4122814912218889da61
|
|
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3'
|
|
name: 'Dell R840: Voltage probe [{#VPROBE_NAME}]: Status is not OK'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the device''s voltage.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: 7379dd15da4e48f295ab466eb45895da
|
|
name: 'Voltage probe [{#VPROBE_NAME}]: Voltage'
|
|
type: DEPENDENT
|
|
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
|
|
delay: '0'
|
|
value_type: FLOAT
|
|
units: V
|
|
description: 'This attribute defines the reading for a voltage probe.'
|
|
preprocessing:
|
|
- type: SNMP_WALK_VALUE
|
|
parameters:
|
|
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}'
|
|
- '0'
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '0.001'
|
|
master_item:
|
|
key: dell.server.voltage.walk
|
|
tags:
|
|
- tag: component
|
|
value: voltage
|
|
graph_prototypes:
|
|
- uuid: c40ac46b891f4ed892c532c8ff73ea50
|
|
name: 'Dell R840: Voltage probe [{#VPROBE_NAME}]: Voltage'
|
|
graph_items:
|
|
- color: 199C0D
|
|
item:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
|
|
master_item:
|
|
key: dell.server.voltage.walk
|
|
preprocessing:
|
|
- type: SNMP_WALK_TO_JSON
|
|
parameters:
|
|
- '{#VPROBE_NAME}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1
|
|
- '0'
|
|
- '{#VPROBE_TYPE}'
|
|
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1
|
|
- '0'
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 6h
|
|
tags:
|
|
- tag: class
|
|
value: hardware
|
|
- tag: target
|
|
value: dell
|
|
- tag: target
|
|
value: 'dell poweredge'
|
|
macros:
|
|
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
|
|
value: '^.*Voltage.*$'
|
|
description: 'Sets the regex string of voltage probe names to allow in discovery.'
|
|
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
|
|
value: CHANGE_IF_NEEDED
|
|
description: 'Sets the regex string of voltage probe names to ignore in discovery.'
|
|
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
|
|
value: 18|16
|
|
description: 'Sets the regex string of voltage probe types to allow in discovery.'
|
|
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
|
|
value: CHANGE_IF_NEEDED
|
|
description: 'Sets the regex string of voltage probe types to ignore in discovery.'
|
|
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
|
|
value: '3'
|
|
description: 'The critical status of the disk array cache battery for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
|
|
value: '2'
|
|
description: 'The OK status of the disk array cache battery for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
|
|
value: '4'
|
|
description: 'The warning status of the disk array cache battery for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
|
|
value: '5'
|
|
description: 'The critical status of the disk array for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
|
|
value: '6'
|
|
description: 'The disaster status of the disk array for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
|
|
value: '4'
|
|
description: 'The warning status of the disk array for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}'
|
|
value: '1'
|
|
description: 'The critical S.M.A.R.T status of the disk for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}'
|
|
value: '5'
|
|
description: 'The critical status of the disk for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
|
|
value: '6'
|
|
description: 'The critical status of the disk for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
|
|
value: '4'
|
|
description: 'The warning status of the disk for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}'
|
|
value: '8'
|
|
description: 'The critical value of the FAN sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}'
|
|
value: '5'
|
|
description: 'The critical value of the FAN sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
|
|
value: '10'
|
|
description: 'The critical value of the FAN sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}'
|
|
value: '9'
|
|
description: 'The critical value of the FAN sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}'
|
|
value: '6'
|
|
description: 'The critical value of the FAN sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
|
|
value: '7'
|
|
description: 'The warning value of the FAN sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}'
|
|
value: '4'
|
|
description: 'The warning value of the FAN sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}'
|
|
value: '5'
|
|
description: 'The critical status of health for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}'
|
|
value: '6'
|
|
description: 'The disaster status of health for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}'
|
|
value: '4'
|
|
description: 'The warning status of health for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.IFCONTROL}'
|
|
value: '1'
|
|
description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".'
|
|
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}'
|
|
value: '5'
|
|
description: 'The critical value of the PSU sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
|
|
value: '6'
|
|
description: 'The critical value of the PSU sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
|
|
value: '4'
|
|
description: 'The warning value of the PSU sensor for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}'
|
|
value: '8'
|
|
description: 'The critical status of the temperature probe for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}'
|
|
value: '5'
|
|
description: 'The critical status of the temperature probe for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
|
|
value: '9'
|
|
description: 'The critical status of the temperature probe for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}'
|
|
value: '6'
|
|
description: 'The critical status of the temperature probe for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
|
|
value: '3'
|
|
description: 'The OK status of the temperature probe for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
|
|
value: '7'
|
|
description: 'The warning status of the temperature probe for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}'
|
|
value: '4'
|
|
description: 'The warning status of the temperature probe for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.TIMEOUT}'
|
|
value: 5m
|
|
description: 'The time interval for the SNMP agent availability trigger expression.'
|
|
- macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
|
|
value: '3'
|
|
description: 'The critical status of the virtual disk for the trigger expression.'
|
|
- macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
|
|
value: '4'
|
|
description: 'The warning status of the virtual disk for the trigger expression.'
|
|
dashboards:
|
|
- uuid: 05115b5959dd46e4aa916b6a13cf2e6b
|
|
name: Overview
|
|
pages:
|
|
- name: Overview
|
|
display_period: '30'
|
|
widgets:
|
|
- type: item
|
|
name: 'System health'
|
|
width: '36'
|
|
height: '4'
|
|
hide_header: 'YES'
|
|
fields:
|
|
- type: STRING
|
|
name: bg_color
|
|
value: 2196F3
|
|
- type: STRING
|
|
name: description
|
|
value: 'System Health'
|
|
- type: STRING
|
|
name: desc_color
|
|
value: FFFFFF
|
|
- type: INTEGER
|
|
name: desc_v_pos
|
|
value: '0'
|
|
- type: ITEM
|
|
name: itemid.0
|
|
value:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.status[globalSystemStatus]'
|
|
- type: INTEGER
|
|
name: show.0
|
|
value: '2'
|
|
- type: INTEGER
|
|
name: show.1
|
|
value: '1'
|
|
- type: STRING
|
|
name: value_color
|
|
value: FFFFFF
|
|
- type: INTEGER
|
|
name: value_size
|
|
value: '35'
|
|
- type: item
|
|
name: 'Serial number'
|
|
'y': '4'
|
|
width: '36'
|
|
height: '4'
|
|
hide_header: 'YES'
|
|
fields:
|
|
- type: STRING
|
|
name: bg_color
|
|
value: 2196F3
|
|
- type: STRING
|
|
name: description
|
|
value: 'Serial number'
|
|
- type: STRING
|
|
name: desc_color
|
|
value: FFFFFF
|
|
- type: INTEGER
|
|
name: desc_v_pos
|
|
value: '0'
|
|
- type: ITEM
|
|
name: itemid.0
|
|
value:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.hw.serialnumber[systemServiceTag]'
|
|
- type: INTEGER
|
|
name: show.0
|
|
value: '2'
|
|
- type: INTEGER
|
|
name: show.1
|
|
value: '1'
|
|
- type: STRING
|
|
name: value_color
|
|
value: FFFFFF
|
|
- type: INTEGER
|
|
name: value_size
|
|
value: '35'
|
|
- type: item
|
|
name: 'HW model'
|
|
x: '36'
|
|
width: '36'
|
|
height: '4'
|
|
hide_header: 'YES'
|
|
fields:
|
|
- type: STRING
|
|
name: bg_color
|
|
value: 2196F3
|
|
- type: STRING
|
|
name: description
|
|
value: 'HW model'
|
|
- type: STRING
|
|
name: desc_color
|
|
value: FFFFFF
|
|
- type: INTEGER
|
|
name: desc_v_pos
|
|
value: '0'
|
|
- type: ITEM
|
|
name: itemid.0
|
|
value:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.hw.model[systemModelName]'
|
|
- type: INTEGER
|
|
name: show.0
|
|
value: '2'
|
|
- type: INTEGER
|
|
name: show.1
|
|
value: '1'
|
|
- type: STRING
|
|
name: value_color
|
|
value: FFFFFF
|
|
- type: INTEGER
|
|
name: value_size
|
|
value: '35'
|
|
- type: item
|
|
name: Firmware
|
|
x: '36'
|
|
'y': '4'
|
|
width: '36'
|
|
height: '4'
|
|
hide_header: 'YES'
|
|
fields:
|
|
- type: STRING
|
|
name: bg_color
|
|
value: 2196F3
|
|
- type: STRING
|
|
name: description
|
|
value: Firmware
|
|
- type: STRING
|
|
name: desc_color
|
|
value: FFFFFF
|
|
- type: INTEGER
|
|
name: desc_v_pos
|
|
value: '0'
|
|
- type: ITEM
|
|
name: itemid.0
|
|
value:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.hw.firmware[racFirmwareVersion]'
|
|
- type: INTEGER
|
|
name: show.0
|
|
value: '2'
|
|
- type: INTEGER
|
|
name: show.1
|
|
value: '1'
|
|
- type: STRING
|
|
name: value_color
|
|
value: FFFFFF
|
|
- type: INTEGER
|
|
name: value_size
|
|
value: '35'
|
|
- name: Discoveries
|
|
display_period: '30'
|
|
widgets:
|
|
- type: honeycomb
|
|
name: 'Interface link'
|
|
width: '72'
|
|
height: '4'
|
|
fields:
|
|
- type: STRING
|
|
name: items.0
|
|
value: 'NIC*Link status'
|
|
- type: STRING
|
|
name: primary_label
|
|
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
|
|
- type: INTEGER
|
|
name: primary_label_size
|
|
value: '15'
|
|
- type: INTEGER
|
|
name: primary_label_size_type
|
|
value: '1'
|
|
- type: STRING
|
|
name: reference
|
|
value: AAAAA
|
|
- type: STRING
|
|
name: thresholds.0.color
|
|
value: 069C56
|
|
- type: STRING
|
|
name: thresholds.0.threshold
|
|
value: '1'
|
|
- type: STRING
|
|
name: thresholds.1.color
|
|
value: FF681E
|
|
- type: STRING
|
|
name: thresholds.1.threshold
|
|
value: '2'
|
|
- type: STRING
|
|
name: thresholds.2.color
|
|
value: D3212C
|
|
- type: STRING
|
|
name: thresholds.2.threshold
|
|
value: '3'
|
|
- type: honeycomb
|
|
name: 'Temperature sensors'
|
|
'y': '4'
|
|
width: '72'
|
|
height: '4'
|
|
fields:
|
|
- type: STRING
|
|
name: items.0
|
|
value: 'Probe*Value'
|
|
- type: STRING
|
|
name: primary_label
|
|
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
|
|
- type: INTEGER
|
|
name: primary_label_size_type
|
|
value: '1'
|
|
- type: STRING
|
|
name: reference
|
|
value: AAAAB
|
|
- type: INTEGER
|
|
name: secondary_label_decimal_places
|
|
value: '0'
|
|
- type: honeycomb
|
|
name: 'Physical disks'
|
|
'y': '8'
|
|
width: '36'
|
|
height: '4'
|
|
fields:
|
|
- type: STRING
|
|
name: items.0
|
|
value: 'Physical disk*: Status'
|
|
- type: STRING
|
|
name: primary_label
|
|
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
|
|
- type: INTEGER
|
|
name: primary_label_size
|
|
value: '15'
|
|
- type: INTEGER
|
|
name: primary_label_size_type
|
|
value: '1'
|
|
- type: STRING
|
|
name: reference
|
|
value: AAAAC
|
|
- type: STRING
|
|
name: thresholds.0.color
|
|
value: FF980E
|
|
- type: STRING
|
|
name: thresholds.0.threshold
|
|
value: '0'
|
|
- type: STRING
|
|
name: thresholds.1.color
|
|
value: 069C56
|
|
- type: STRING
|
|
name: thresholds.1.threshold
|
|
value: '3'
|
|
- type: STRING
|
|
name: thresholds.2.color
|
|
value: D3212C
|
|
- type: STRING
|
|
name: thresholds.2.threshold
|
|
value: '4'
|
|
- type: honeycomb
|
|
name: 'Power supplies'
|
|
'y': '12'
|
|
width: '36'
|
|
height: '4'
|
|
fields:
|
|
- type: STRING
|
|
name: items.0
|
|
value: 'Voltage probe*Voltage'
|
|
- type: STRING
|
|
name: primary_label
|
|
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
|
|
- type: INTEGER
|
|
name: primary_label_size_type
|
|
value: '1'
|
|
- type: STRING
|
|
name: reference
|
|
value: AAAAE
|
|
- type: honeycomb
|
|
name: 'Virtual disks'
|
|
x: '36'
|
|
'y': '8'
|
|
width: '36'
|
|
height: '4'
|
|
fields:
|
|
- type: STRING
|
|
name: items.0
|
|
value: 'Virtual disk*: Status'
|
|
- type: STRING
|
|
name: primary_label
|
|
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
|
|
- type: INTEGER
|
|
name: primary_label_size_type
|
|
value: '1'
|
|
- type: STRING
|
|
name: reference
|
|
value: AAAAD
|
|
- type: STRING
|
|
name: thresholds.0.color
|
|
value: FF980E
|
|
- type: STRING
|
|
name: thresholds.0.threshold
|
|
value: '1'
|
|
- type: STRING
|
|
name: thresholds.1.color
|
|
value: 069C56
|
|
- type: STRING
|
|
name: thresholds.1.threshold
|
|
value: '2'
|
|
- type: STRING
|
|
name: thresholds.2.color
|
|
value: D3212C
|
|
- type: STRING
|
|
name: thresholds.2.threshold
|
|
value: '3'
|
|
- type: honeycomb
|
|
name: Fans
|
|
x: '36'
|
|
'y': '12'
|
|
width: '36'
|
|
height: '4'
|
|
fields:
|
|
- type: STRING
|
|
name: items.0
|
|
value: 'Fan*Status'
|
|
- type: STRING
|
|
name: primary_label
|
|
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
|
|
- type: INTEGER
|
|
name: primary_label_size_type
|
|
value: '1'
|
|
- type: STRING
|
|
name: reference
|
|
value: AAAAF
|
|
- type: STRING
|
|
name: thresholds.0.color
|
|
value: FF980E
|
|
- type: STRING
|
|
name: thresholds.0.threshold
|
|
value: '0'
|
|
- type: STRING
|
|
name: thresholds.1.color
|
|
value: 069C56
|
|
- type: STRING
|
|
name: thresholds.1.threshold
|
|
value: '3'
|
|
- type: STRING
|
|
name: thresholds.2.color
|
|
value: D3212C
|
|
- type: STRING
|
|
name: thresholds.2.threshold
|
|
value: '4'
|
|
valuemaps:
|
|
- uuid: 692c968229d64965b3f6c59ca79b4522
|
|
name: 'IDRAC-MIB-SMIv2::batteryState'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: Unknown
|
|
- value: '2'
|
|
newvalue: Ready
|
|
- value: '3'
|
|
newvalue: Failed
|
|
- value: '4'
|
|
newvalue: Degraded
|
|
- value: '5'
|
|
newvalue: Missing
|
|
- value: '6'
|
|
newvalue: Charging
|
|
- value: '7'
|
|
newvalue: 'Below threshold'
|
|
- uuid: 1ee27c8f7c9d4f7cbafc8c7567b70c67
|
|
name: 'IDRAC-MIB-SMIv2::BooleanType'
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: ok
|
|
- value: '1'
|
|
newvalue: failed
|
|
- uuid: a866da3a7c4e43d086efafb07178f8ec
|
|
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: unknown
|
|
- value: '1'
|
|
newvalue: connected
|
|
- value: '2'
|
|
newvalue: disconnected
|
|
- value: '3'
|
|
newvalue: driverBad
|
|
- value: '4'
|
|
newvalue: driverDisabled
|
|
- value: '10'
|
|
newvalue: hardwareInitalizing
|
|
- value: '11'
|
|
newvalue: hardwareResetting
|
|
- value: '12'
|
|
newvalue: hardwareClosing
|
|
- value: '13'
|
|
newvalue: hardwareNotReady
|
|
- uuid: c238adb07fea463a8cb21f962fcb24d9
|
|
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: other
|
|
- value: '2'
|
|
newvalue: unknown
|
|
- value: '3'
|
|
newvalue: ok
|
|
- value: '4'
|
|
newvalue: nonCritical
|
|
- value: '5'
|
|
newvalue: critical
|
|
- value: '6'
|
|
newvalue: nonRecoverable
|
|
- uuid: ee4ff377e3984685993e230911e6c13e
|
|
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: other
|
|
- value: '2'
|
|
newvalue: unknown
|
|
- value: '3'
|
|
newvalue: ok
|
|
- value: '4'
|
|
newvalue: nonCritical
|
|
- value: '5'
|
|
newvalue: critical
|
|
- value: '6'
|
|
newvalue: nonRecoverable
|
|
- uuid: 7409409d584845e39579b478171a600a
|
|
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: Unknown
|
|
- value: '2'
|
|
newvalue: HDD
|
|
- value: '3'
|
|
newvalue: SSD
|
|
- uuid: 092b816c537e4fe79c7f5826037c5872
|
|
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: internalError
|
|
- value: '2'
|
|
newvalue: thermalTrip
|
|
- value: '32'
|
|
newvalue: configurationError
|
|
- value: '128'
|
|
newvalue: processorPresent
|
|
- value: '256'
|
|
newvalue: processorDisabled
|
|
- value: '512'
|
|
newvalue: terminatorPresent
|
|
- value: '1024'
|
|
newvalue: processorThrottled
|
|
- uuid: 1a301ddb56ba46d38314d5c3129544b4
|
|
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: other
|
|
- value: '2'
|
|
newvalue: unknown
|
|
- value: '3'
|
|
newvalue: ok
|
|
- value: '4'
|
|
newvalue: nonCriticalUpper
|
|
- value: '5'
|
|
newvalue: criticalUpper
|
|
- value: '6'
|
|
newvalue: nonRecoverableUpper
|
|
- value: '7'
|
|
newvalue: nonCriticalLower
|
|
- value: '8'
|
|
newvalue: criticalLower
|
|
- value: '9'
|
|
newvalue: nonRecoverableLower
|
|
- value: '10'
|
|
newvalue: failed
|
|
- uuid: f3e45e2d860b48c2a6f2b7a068cac361
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: Other
|
|
- value: '2'
|
|
newvalue: RAID-0
|
|
- value: '3'
|
|
newvalue: RAID-1
|
|
- value: '4'
|
|
newvalue: RAID-5
|
|
- value: '5'
|
|
newvalue: RAID-6
|
|
- value: '6'
|
|
newvalue: RAID-10
|
|
- value: '7'
|
|
newvalue: RAID-50
|
|
- value: '8'
|
|
newvalue: RAID-60
|
|
- value: '9'
|
|
newvalue: 'Concatenated RAID 1'
|
|
- value: '10'
|
|
newvalue: 'Concatenated RAID 5'
|
|
- uuid: 6d457df3bf6646b3824ccc7be984587c
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: 'Not applicable'
|
|
- value: '2'
|
|
newvalue: Reconstructing
|
|
- value: '3'
|
|
newvalue: Resynching
|
|
- value: '4'
|
|
newvalue: Initializing
|
|
- value: '5'
|
|
newvalue: 'Background init'
|
|
- uuid: 47bf555344fd4fc1a15b372374bc75a7
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: 'No Read Ahead'
|
|
- value: '2'
|
|
newvalue: 'Read Ahead'
|
|
- value: '3'
|
|
newvalue: 'Adaptive Read Ahead'
|
|
- uuid: 2e035bf66ff144d8ab5e0c681bb246f6
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: Unknown
|
|
- value: '2'
|
|
newvalue: Online
|
|
- value: '3'
|
|
newvalue: Failed
|
|
- value: '4'
|
|
newvalue: Degraded
|
|
- uuid: 59eff775037e4e58925d3475ed0b0e34
|
|
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
|
|
mappings:
|
|
- value: '1'
|
|
newvalue: 'Write Through'
|
|
- value: '2'
|
|
newvalue: 'Write Back'
|
|
- value: '3'
|
|
newvalue: 'Force Write Back'
|
|
- uuid: 6b1b96e063084c8eb474006a9c691fb5
|
|
name: zabbix.host.available
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: 'not available'
|
|
- value: '1'
|
|
newvalue: available
|
|
- value: '2'
|
|
newvalue: unknown
|
|
triggers:
|
|
- uuid: 93a63868ca09460e89d3f40f72259828
|
|
expression: '(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)'
|
|
name: 'Dell R840: Host has been restarted'
|
|
event_name: 'Dell R840: {HOST.NAME} has been restarted (uptime < 10m)'
|
|
priority: WARNING
|
|
description: 'Uptime is less than 10 minutes.'
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
graphs:
|
|
- uuid: b0782a6e652a457b8004ae0436d2b3b0
|
|
name: 'Dell R840: Uptime'
|
|
graph_items:
|
|
- color: 199C0D
|
|
item:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.hw.uptime[systemPowerUpTime]'
|
|
- sortorder: '1'
|
|
color: F63100
|
|
item:
|
|
host: 'DELL PowerEdge R840 by SNMP'
|
|
key: 'dell.server.net.uptime[snmpEngineTime]'
|