zabbix_export: version: '7.0' template_groups: - uuid: e960332b3f6c46a1956486d4f3f99fce name: 'Templates/Server hardware' templates: - uuid: fc834b8da8864678b55557e9a237eac9 template: 'DELL PowerEdge R840 by SNMP' name: 'DELL PowerEdge R840 by SNMP' description: | Template for DELL PowerEdge R840 servers with iDRAC version 7 and later. MIBs used: HOST-RESOURCES-MIB IDRAC-MIB-SMIv2 SNMPv2-MIB You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates Generated by official Zabbix template tool "Templator" vendor: name: Zabbix version: 7.0-5 groups: - name: 'Templates/Server hardware' items: - uuid: 7f08a9bf1d5540f0b05040d16d67d87a name: 'SNMP walk RAID controllers table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]' key: dell.server.array.controller.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.' tags: - tag: component value: raw - uuid: 39d26209dd3242c5ad90380b566c01aa name: 'SNMP walk Battery table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]' key: dell.server.battery.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.' tags: - tag: component value: raw - uuid: 077c58fdb06c4191bf8f194b4c9108e7 name: 'BIOS version' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]' key: dell.server.bios.version value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the version name of the system BIOS. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: 65da5f84a8bb43da8b72ddbe6d757fa8 name: 'System contact details' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.4.0]' key: 'dell.server.contact[sysContact]' delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB Name and contact information of the contact person for the node. If not provided, the value is a zero-length string. inventory_link: CONTACT preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: 94bcc2449dfa4bb59fd778ba96e3abdf name: 'SNMP walk Processor device tables' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]' key: dell.server.cpu.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.' tags: - tag: component value: raw - uuid: 51c9b68b617c498eb612807734076367 name: 'System description' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.1.0]' key: 'dell.server.descr[sysDescr]' delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: c888185c08f84b059fdbf7ff0fa8eb6a name: 'SNMP walk Physical disk table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]' key: dell.server.disk.physical.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.' tags: - tag: component value: raw - uuid: f141e6e279fe4b3db65bbfe7e559389b name: 'SNMP walk Virtual disk table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]' key: dell.server.disk.virtual.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.' tags: - tag: component value: raw - uuid: d7e317cd293c4d8fa39f4283b79de6e4 name: 'SNMP walk Cooling device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]' key: dell.server.fan.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.' tags: - tag: component value: raw - uuid: 09e33063d84e486fb4964af35916cc25 name: 'Firmware version' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]' key: 'dell.server.hw.firmware[racFirmwareVersion]' delay: 1h value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the firmware version of a remote access card. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 26f924a3a9e1470891cb0d9e9136ad9d expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0' name: 'Dell R840: Firmware has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: INFO description: 'Firmware version has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: b34415ae1ac84375834612f402d4ea0c name: 'Hardware model name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]' key: 'dell.server.hw.model[systemModelName]' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the model name of the system. inventory_link: MODEL preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: b46ad39d968141259ace337d70744001 name: 'Hardware serial number' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]' key: 'dell.server.hw.serialnumber[systemServiceTag]' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the service tag of the system. inventory_link: SERIALNO_A preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: 8d1e926bb5f640b4bf8c8342b5cf1d56 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0' name: 'Dell R840: Device has been replaced' event_name: 'Dell R840: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: afa223e9d16b41deaac482b8328ba0e4 name: 'Uptime (hardware)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]' key: 'dell.server.hw.uptime[systemPowerUpTime]' trends: '0' units: uptime description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the power-up time of the system in seconds. tags: - tag: component value: system - uuid: 0445a9767ce34fb7b2be072609504011 name: 'System location' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.6.0]' key: 'dell.server.location[sysLocation]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string. inventory_link: LOCATION preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: c84cc87d95664f66a674eefec258841a name: 'Memory, total size' type: CALCULATED key: dell.server.memory.size.total units: B params: 'sum(last_foreach(//dell.server.memory.size[*]))' description: 'Total memory amount on the device.' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: memory triggers: - uuid: c44165ebea1346c78970c1f8d96da0be expression: 'change(/DELL PowerEdge R840 by SNMP/dell.server.memory.size.total)>0' name: 'Dell R840: Memory amount has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: AVERAGE tags: - tag: scope value: availability - uuid: 6ad434d7873f4c9e846ebaefa3e3640c name: 'SNMP walk Memory device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]' key: dell.server.memory.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.' tags: - tag: component value: raw - uuid: 58be11401c084b0a81ebadbde199133d name: 'System name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.5.0]' key: 'dell.server.name[sysName]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string. inventory_link: NAME preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: 673eda315d9b4dfcb15509fa01fffac2 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName]))>0' name: 'Dell R840: System name has changed' event_name: 'Dell R840: System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'The name of the system has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 73802978c64b4d978b6e06ede9f5d760 name: 'SNMP walk Network device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]' key: dell.server.net.if.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.' tags: - tag: component value: raw - uuid: 49473f26fedb459c9642704bae33adb1 name: 'Uptime (network)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]' key: 'dell.server.net.uptime[snmpEngineTime]' trends: '0' units: uptime description: | MIB: SNMP-FRAMEWORK-MIB The number of seconds since the value of the snmpEngineBoots object last changed. tags: - tag: component value: system - uuid: 808a099b33c6438e8fd91a4f29c41f35 name: 'System object ID' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.2.0]' key: 'dell.server.objectid[sysObjectID]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1). preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: 0b013a35762f4bdab3ffeec58176779a name: 'SNMP walk Power supply table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]' key: dell.server.psu.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.' tags: - tag: component value: raw - uuid: c2ab8a025fb34e878f7bbea9db51dbea name: 'SNMP walk Temperature sensor table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]' key: dell.server.sensor.temp.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.' tags: - tag: component value: raw - uuid: 42be6e0b9fbe46179597650622a2241a name: 'Overall system health status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]' key: 'dell.server.status[globalSystemStatus]' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: health - tag: component value: system triggers: - uuid: c3e8fd8fd0d0406d8c2d9a2c45eeecee expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}' name: 'Dell R840: System is in unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 4b32809fad0e468bb5f1bd09c7078def expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}' name: 'Dell R840: System status is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for errors.' tags: - tag: scope value: availability - uuid: a75745134dad4592a23c43ca77975d95 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}' name: 'Dell R840: System status is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for warnings.' dependencies: - name: 'Dell R840: System status is in critical state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}' tags: - tag: scope value: availability - uuid: 8d967ad6ac2b46c28072f713cd11b59f name: 'Operating system' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]' key: 'dell.server.sw.os[systemOSName]' delay: 1h value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the name of the operating system that the host is running. inventory_link: OS preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 4096c84c616743bfbfca9707e43a3db3 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName]))>0' name: 'Dell R840: Operating system description has changed' priority: INFO description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: f1068ce5a40b45ba9388e17f6dce3b79 name: 'SNMP walk System battery table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]' key: dell.server.system.battery.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.' tags: - tag: component value: raw - uuid: b5c04f5439244a87991b2b053b5f8f9b name: 'SNMP walk Voltage probe table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]' key: dell.server.voltage.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.' tags: - tag: component value: raw - uuid: 074f6d9a11814bb7909d99664192421d name: 'SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback delay: '0' value_type: LOG trends: '0' description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: component value: network - uuid: b690c870c11c40ecbd162a01e82abbfe name: 'SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' description: | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown valuemap: name: zabbix.host.available tags: - tag: component value: health - tag: component value: system triggers: - uuid: 6f00331597c0443a93c182a86040cca4 expression: 'max(/DELL PowerEdge R840 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0' name: 'Dell R840: No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' tags: - tag: scope value: availability discovery_rules: - uuid: 23349a5dacb34beda5c745461fd2b2a9 name: 'Array controller discovery' type: DEPENDENT key: array.discovery delay: '0' description: 'Array controller discovery.' item_prototypes: - uuid: 9afa1fe4ec6343db9abdb7b1a6c57b10 name: 'Controller [{#CNTLR_NAME}]: Model' type: DEPENDENT key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The controller's name as represented in Storage Management. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.array.controller.walk tags: - tag: component value: diskarray - tag: component value: storage - uuid: 3af6572ca94d49da8b6c59185ddeb744 name: 'Controller [{#CNTLR_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.array.controller.walk tags: - tag: component value: diskarray - tag: component value: storage trigger_prototypes: - uuid: 149de042930a444d82d1a8016efaea2c expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' name: 'Dell R840: Controller [{#CNTLR_NAME}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability - uuid: 2fb2ddb749ed450da886420fdc5da394 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: b8cbc4a8cc404bcc83bf24af56997432 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}' name: 'Dell R840: Controller [{#CNTLR_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: Controller [{#CNTLR_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' - name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability master_item: key: dell.server.array.controller.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38 - '0' - '{#CNTLR_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 3f6ece6fbaae461bbb01f7adaeca9756 name: 'Battery discovery' type: DEPENDENT key: battery.discovery delay: '0' description: 'Battery discovery.' item_prototypes: - uuid: 9f78de09167d4de9b7c5f8606d8f9bb2 name: 'Battery [{#BATTERY_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold. valuemap: name: 'IDRAC-MIB-SMIv2::batteryState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.battery.walk tags: - tag: component value: battery - tag: component value: diskarray trigger_prototypes: - uuid: 3624b95de99c42ac948402a4ca13a616 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 560fd4dcbf4a4ee8b49ad8880b767591 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' name: 'Dell R840: Battery [{#BATTERY_NAME}]: Not in optimal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' - name: 'Dell R840: Battery [{#BATTERY_NAME}]: Warning state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' tags: - tag: scope value: availability - uuid: dc5c489632c54cf3a393cc78e50020db expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' name: 'Dell R840: Battery [{#BATTERY_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' tags: - tag: scope value: availability master_item: key: dell.server.battery.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#BATTERY_NUM}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 - '0' - '{#BATTERY_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 3bcf2e1613ce4bcf82c8154dfa5dc7c8 name: 'CPU status discovery' type: DEPENDENT key: cpu.discovery delay: '0' description: 'CPU status discovery.' item_prototypes: - uuid: b5bc4152569c4d94ac18af051ac53545 name: 'CPU [{#CPU_FQDD}]: State' type: DEPENDENT key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]' delay: '0' description: 'This attribute defines the reading of the processor device status probe.' valuemap: name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.cpu.walk tags: - tag: component value: cpu trigger_prototypes: - uuid: 723b859cb5a94d339c7d0cba9ad2dc8d expression: 'bitand(last(/DELL PowerEdge R840 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0' name: 'Dell R840: CPU [{#CPU_FQDD}]: Reading error' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 CPU probe reading flag is not `processorPresent`. tags: - tag: scope value: availability - uuid: 417e257e354542aa84741c435b7fe916 name: 'CPU [{#CPU_FQDD}]: Status' type: DEPENDENT key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]' delay: '0' description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.cpu.walk tags: - tag: component value: cpu trigger_prototypes: - uuid: 66665f584f9a43c192cf995a4ef89f09 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3' name: 'Dell R840: CPU [{#CPU_FQDD}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 CPU status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.cpu.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#CPU_FQDD}' - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 91a882b4c4fe48ac9224fdfb811bcf71 name: 'Fan discovery' type: DEPENDENT key: fan.discovery delay: '0' filter: conditions: - macro: '{#TYPE}' value: '3' formulaid: A description: 'Fan discovery.' item_prototypes: - uuid: 8ee74a624afc41d0b607da978b2b0858 name: 'Fan [{#FAN_DESCR}]: Speed' type: DEPENDENT key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]' delay: '0' units: rpm description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`. When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device. When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}' - '0' master_item: key: dell.server.fan.walk tags: - tag: component value: fan - uuid: 40ffe2dbed764fab8f76ab3d77c4d48b name: 'Fan [{#FAN_DESCR}]: Status' type: DEPENDENT key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the cooling device. valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.fan.walk tags: - tag: component value: fan trigger_prototypes: - uuid: 4c81607b448445b7859af43eefda9c88 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' name: 'Dell R840: Fan [{#FAN_DESCR}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit.' tags: - tag: scope value: availability - uuid: 9c23542532ca4414948cfaf5fb7976d2 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R840: Fan [{#FAN_DESCR}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the fan unit.' dependencies: - name: 'Dell R840: Fan [{#FAN_DESCR}]: Critical state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability graph_prototypes: - uuid: 3ca078011770494280453bce2c2198fe name: 'Dell R840: Fan [{#FAN_DESCR}]: Speed' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]' master_item: key: dell.server.fan.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.5 - '0' - '{#FAN_DESCR}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.8 - '0' - '{#TYPE}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.7 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: ab7d2361eeb946a48bb557e9dbc8904c name: 'Memory discovery' type: DEPENDENT key: memory.discovery delay: '0' description: 'Memory discovery.' item_prototypes: - uuid: 0c87c1f952484471afad86f77c13073a name: 'Memory [{#SNMPVALUE}]: Size' type: DEPENDENT key: 'dell.server.memory.size[{#SNMPVALUE}]' delay: '0' units: B description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - type: MULTIPLIER parameters: - '1024' master_item: key: dell.server.memory.walk tags: - tag: component value: memory - uuid: 2dab90151d1144fda74204e88c10067b name: 'Memory [{#SNMPVALUE}]: Status' type: DEPENDENT key: 'dell.server.memory.status[{#SNMPVALUE}]' delay: '0' description: 'This attribute defines the status of the memory device.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.memory.walk tags: - tag: component value: memory trigger_prototypes: - uuid: 9ef225ff91114afdba9ee315c09a53c8 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3' name: 'Dell R840: Memory [{#SNMPVALUE}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 Memory status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.memory.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 507b67db9d33407ab04b5b26eee17f33 name: 'Network interface discovery' type: DEPENDENT key: net.if.discovery delay: '0' description: 'Discovery of network interfaces.' item_prototypes: - uuid: 3400e8c414144a88baed85ccd1179008 name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status' type: DEPENDENT key: 'dell.server.net.if.link[{#NIC_FQDD}]' delay: '0' description: 'This attribute defines the connection status of the network device.' valuemap: name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.net.if.walk tags: - tag: component value: network trigger_prototypes: - uuid: 1fe39881ec004b87a41c1d8d44479981 expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0' name: 'Dell R840: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | This trigger expression works as follows: 1. It can be triggered if the operations status is Down. 2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down. 3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.) manual_close: 'YES' tags: - tag: scope value: availability - uuid: 1e3ec0d9d8284aed8edeff4490afe605 name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status' type: DEPENDENT key: 'dell.server.net.if.status[{#NIC_FQDD}]' delay: '0' description: 'This attribute defines the status of the network device.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.net.if.walk tags: - tag: component value: network trigger_prototypes: - uuid: 5196e2886545427dbafe649cb3cd651f expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3' name: 'Dell R840: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 Network interface status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.net.if.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#NIC_FQDD}' - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1 - '0' - '{#NIC_MAC}' - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1 - '2' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: d9c26b4a06bc45acb742315896b358da name: 'Physical disk discovery' type: DEPENDENT key: physicaldisk.discovery delay: '0' description: 'Physical disk discovery.' item_prototypes: - uuid: be048b1285ba4a21a14e5f79727c2b91 name: 'Physical disk [{#DISK_NAME}]: Media type' type: DEPENDENT key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Drive (SSD). valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 79fa0faedeb743c1a9f9c0ea0d454935 name: 'Physical disk [{#DISK_NAME}]: Model name' type: DEPENDENT key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The model number of the physical disk. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: b2668345145f4d638dbb364afbdfb9f8 name: 'Physical disk [{#DISK_NAME}]: Serial number' type: DEPENDENT key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The physical disk's unique identification number from the manufacturer. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 7d2a1a115b304ca5823618360675d43d expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0' name: 'Dell R840: Physical disk [{#DISK_NAME}] has been replaced' event_name: 'Dell R840: [{#DISK_NAME}] has been replaced (new serial number received)' priority: INFO description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 6e50bc2fa3ee4ceeb8fe044a7d83f836 name: 'Physical disk [{#DISK_NAME}]: Size' type: DEPENDENT key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]' delay: '0' trends: '0' units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the physical disk in megabytes. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 3a2cd6a4c4ea4a3ab4ccbd555ee17f5b name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status' type: DEPENDENT key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 Indicates whether the physical disk has received a predictive failure alert. valuemap: name: 'IDRAC-MIB-SMIv2::BooleanType' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 3a648ce450cd4236bcda1b48f6cb840f expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}' name: 'Dell R840: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Disk probably requires replacement.' dependencies: - name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability - uuid: fbb5d836a0c344e0929bb406cf9721ee name: 'Physical disk [{#DISK_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 426d1d50afb04253b92a5b99c9e96206 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check physical disk for warnings or errors.' tags: - tag: scope value: availability - uuid: 1d0a3f13c2fd4bc8be2c4305850c984c expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}' name: 'Dell R840: Physical disk [{#DISK_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check physical disk for warnings or errors.' dependencies: - name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability graph_prototypes: - uuid: 2b64a7034bb3455196e2716e622ce404 name: 'Dell R840: Physical disk [{#DISK_NAME}]: Size' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]' master_item: key: dell.server.disk.physical.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 - '0' - '{#DISK_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: d95e02ed8c204fe1b4edf5a3d3ad3847 name: 'PSU discovery' type: DEPENDENT key: psu.discovery delay: '0' description: 'PSU discovery.' item_prototypes: - uuid: fe99911125c54800be75e332c150356b name: 'Power supply [{#PSU_DESCR}]: State' type: DEPENDENT key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the status of the power supply. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.psu.walk tags: - tag: component value: psu trigger_prototypes: - uuid: 519b5f4f8c6f4b6b92eafb910c1e81eb expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' name: 'Dell R840: Power supply [{#PSU_DESCR}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors.' tags: - tag: scope value: availability - uuid: 76ab0ba99e424e43b686d11049b40258 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}' name: 'Dell R840: Power supply [{#PSU_DESCR}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the power supply unit for errors.' dependencies: - name: 'Dell R840: Power supply [{#PSU_DESCR}]: Critical state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' tags: - tag: scope value: availability master_item: key: dell.server.psu.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 - '0' - '{#PSU_DESCR}' - 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 1461820b857d483e9988434b36a9cf6f name: 'System battery discovery' type: DEPENDENT key: system.battery.discovery delay: '0' description: 'System battery discovery.' item_prototypes: - uuid: b4c42aaf69b34fcaa8ff8a23f0767c3a name: 'System battery [{#SNMPVALUE}]: Status' type: DEPENDENT key: 'dell.server.system.battery[{#SNMPVALUE}]' delay: '0' description: 'This attribute defines the status of the battery.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.system.battery.walk tags: - tag: component value: battery trigger_prototypes: - uuid: 9cc273d913d04f58af291d888fd942ff expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3' name: 'Dell R840: System battery [{#SNMPVALUE}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 System battery status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.system.battery.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: e9897a4e0d9d41e38e1cfd198f94d2de name: 'Temperature discovery' type: DEPENDENT key: temp.discovery delay: '0' description: 'Temperature sensor discovery.' item_prototypes: - uuid: c76c966651f940a5ac664c75c88ca689 name: 'Probe [{#SENSOR_LOCALE}]: Status' type: DEPENDENT key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]' delay: '0' value_type: FLOAT trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the temperature probe. Possible values: other(1), -- probe status is not one of the following: unknown(2), -- probe status is unknown (not known or monitored) ok(3), -- probe is reporting a value within the thresholds nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold criticalUpper(5), -- probe has crossed the upper critical threshold nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold nonCriticalLower(7), -- probe has crossed the lower noncritical threshold criticalLower(8), -- probe has crossed the lower critical threshold nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold failed(10) -- probe is not functional valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.sensor.temp.walk tags: - tag: component value: temperature trigger_prototypes: - uuid: d1e14d635c0945298c5319380f8ac2f9 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 567f74a71047410c9dcb8d70298160b1 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}' name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Not in optimal status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the device for faults.' manual_close: 'YES' dependencies: - name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' - name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Warning status' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' tags: - tag: scope value: notice - uuid: da4cdf74306947e7a6d394cca92c8c70 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Warning status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' tags: - tag: scope value: availability - uuid: e498e0b6adca49048b27fcde07880661 name: 'Probe [{#SENSOR_LOCALE}]: Value' type: DEPENDENT key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]' delay: '0' value_type: FLOAT units: °C description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`. When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade. When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '0.1' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.sensor.temp.walk tags: - tag: component value: temperature graph_prototypes: - uuid: aec83bed731d402a841088d092bd6400 name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Value' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]' master_item: key: dell.server.sensor.temp.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 - '0' - '{#SENSOR_LOCALE}' - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 9e2d2bc270704e8eb646b55a7f4e377e name: 'Virtual disk discovery' type: DEPENDENT key: virtualdisk.discovery delay: '0' description: 'Virtual disk discovery.' item_prototypes: - uuid: 27bb804aa7df49ddbc410b268db63218 name: 'Virtual disk [{#DISK_NAME}]: Layout type' type: DEPENDENT key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5 valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 109cd4fc0cc24a6586a282272b8448bb name: 'Virtual disk [{#DISK_NAME}]: Read policy' type: DEPENDENT key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: e4868bd552d34f79823d3c7518babad8 name: 'Virtual disk [{#DISK_NAME}]: Size' type: DEPENDENT key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]' delay: '0' trends: '0' units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the virtual disk in megabytes. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: cf12e14b376940189873430fdfa64c49 name: 'Virtual disk [{#DISK_NAME}]: Operational state' type: DEPENDENT key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 3m master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 344be656d8d84bbca28853d240f5953f name: 'Virtual disk [{#DISK_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost. 4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk trigger_prototypes: - uuid: 443b942a8ea64600a6b1bdda2bb75ec3 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Failed state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the virtual disk for warnings or errors.' tags: - tag: scope value: availability - uuid: be479b50bc2c4320afff5eef0292bc88 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}' name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the virtual disk for warnings or errors.' dependencies: - name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability - uuid: db4f2a2abead4efba3d54124b2e992f7 name: 'Virtual disk [{#DISK_NAME}]: Write policy' type: DEPENDENT key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk graph_prototypes: - uuid: 630725a2e858465ba6c3a6b5b8982d93 name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Size' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]' master_item: key: dell.server.disk.virtual.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 - '0' - '{#DISK_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 43169b68868240d589e8c87bba94ce86 name: 'Voltage probe discovery' type: DEPENDENT key: voltage.discovery delay: '0' filter: evaltype: AND conditions: - macro: '{#VPROBE_NAME}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}' formulaid: A - macro: '{#VPROBE_NAME}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: B - macro: '{#VPROBE_TYPE}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}' formulaid: C - macro: '{#VPROBE_TYPE}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: D description: 'Voltage probe discovery.' item_prototypes: - uuid: d8a499c3a77741d39e4108469009f9b0 name: 'Voltage probe [{#VPROBE_NAME}]: Status' type: DEPENDENT key: 'dell.server.voltage.status[{#VPROBE_NAME}]' delay: '0' description: 'This attribute defines the status of the voltage probe.' valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}' - '0' master_item: key: dell.server.voltage.walk tags: - tag: component value: voltage trigger_prototypes: - uuid: 74ee37bcbbcc4122814912218889da61 expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3' name: 'Dell R840: Voltage probe [{#VPROBE_NAME}]: Status is not OK' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device''s voltage.' tags: - tag: scope value: availability - uuid: 7379dd15da4e48f295ab466eb45895da name: 'Voltage probe [{#VPROBE_NAME}]: Voltage' type: DEPENDENT key: 'dell.server.voltage.value[{#VPROBE_NAME}]' delay: '0' value_type: FLOAT units: V description: 'This attribute defines the reading for a voltage probe.' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '0.001' master_item: key: dell.server.voltage.walk tags: - tag: component value: voltage graph_prototypes: - uuid: c40ac46b891f4ed892c532c8ff73ea50 name: 'Dell R840: Voltage probe [{#VPROBE_NAME}]: Voltage' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.voltage.value[{#VPROBE_NAME}]' master_item: key: dell.server.voltage.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#VPROBE_NAME}' - 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1 - '0' - '{#VPROBE_TYPE}' - 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: class value: hardware - tag: target value: dell - tag: target value: 'dell poweredge' macros: - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}' value: '^.*Voltage.*$' description: 'Sets the regex string of voltage probe names to allow in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'Sets the regex string of voltage probe names to ignore in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}' value: 18|16 description: 'Sets the regex string of voltage probe types to allow in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'Sets the regex string of voltage probe types to ignore in discovery.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' value: '3' description: 'The critical status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' value: '2' description: 'The OK status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' value: '5' description: 'The critical status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' value: '6' description: 'The disaster status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}' value: '1' description: 'The critical S.M.A.R.T status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}' value: '5' description: 'The critical status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' value: '6' description: 'The critical status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' value: '10' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}' value: '5' description: 'The critical status of health for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}' value: '6' description: 'The disaster status of health for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}' value: '4' description: 'The warning status of health for the trigger expression.' - macro: '{$DELL.SNMP.IFCONTROL}' value: '1' description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".' - macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}' value: '5' description: 'The critical value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' value: '6' description: 'The critical value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}' value: '3' description: 'The OK status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.TIMEOUT}' value: 5m description: 'The time interval for the SNMP agent availability trigger expression.' - macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' value: '3' description: 'The critical status of the virtual disk for the trigger expression.' - macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}' value: '4' description: 'The warning status of the virtual disk for the trigger expression.' dashboards: - uuid: 05115b5959dd46e4aa916b6a13cf2e6b name: Overview pages: - name: Overview display_period: '30' widgets: - type: item name: 'System health' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'System Health' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.status[globalSystemStatus]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: 'Serial number' 'y': '4' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'Serial number' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.hw.serialnumber[systemServiceTag]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: 'HW model' x: '36' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'HW model' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.hw.model[systemModelName]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: Firmware x: '36' 'y': '4' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: Firmware - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.hw.firmware[racFirmwareVersion]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - name: Discoveries display_period: '30' widgets: - type: honeycomb name: 'Interface link' width: '72' height: '4' fields: - type: STRING name: items.0 value: 'NIC*Link status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size value: '15' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAA - type: STRING name: thresholds.0.color value: 069C56 - type: STRING name: thresholds.0.threshold value: '1' - type: STRING name: thresholds.1.color value: FF681E - type: STRING name: thresholds.1.threshold value: '2' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '3' - type: honeycomb name: 'Temperature sensors' 'y': '4' width: '72' height: '4' fields: - type: STRING name: items.0 value: 'Probe*Value' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAB - type: INTEGER name: secondary_label_decimal_places value: '0' - type: honeycomb name: 'Physical disks' 'y': '8' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Physical disk*: Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size value: '15' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAC - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '0' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '3' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '4' - type: honeycomb name: 'Power supplies' 'y': '12' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Voltage probe*Voltage' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAE - type: honeycomb name: 'Virtual disks' x: '36' 'y': '8' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Virtual disk*: Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAD - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '1' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '2' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '3' - type: honeycomb name: Fans x: '36' 'y': '12' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Fan*Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAF - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '0' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '3' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '4' valuemaps: - uuid: 692c968229d64965b3f6c59ca79b4522 name: 'IDRAC-MIB-SMIv2::batteryState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Ready - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - value: '5' newvalue: Missing - value: '6' newvalue: Charging - value: '7' newvalue: 'Below threshold' - uuid: 1ee27c8f7c9d4f7cbafc8c7567b70c67 name: 'IDRAC-MIB-SMIv2::BooleanType' mappings: - value: '0' newvalue: ok - value: '1' newvalue: failed - uuid: a866da3a7c4e43d086efafb07178f8ec name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum' mappings: - value: '0' newvalue: unknown - value: '1' newvalue: connected - value: '2' newvalue: disconnected - value: '3' newvalue: driverBad - value: '4' newvalue: driverDisabled - value: '10' newvalue: hardwareInitalizing - value: '11' newvalue: hardwareResetting - value: '12' newvalue: hardwareClosing - value: '13' newvalue: hardwareNotReady - uuid: c238adb07fea463a8cb21f962fcb24d9 name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: ee4ff377e3984685993e230911e6c13e name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: 7409409d584845e39579b478171a600a name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: HDD - value: '3' newvalue: SSD - uuid: 092b816c537e4fe79c7f5826037c5872 name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags' mappings: - value: '1' newvalue: internalError - value: '2' newvalue: thermalTrip - value: '32' newvalue: configurationError - value: '128' newvalue: processorPresent - value: '256' newvalue: processorDisabled - value: '512' newvalue: terminatorPresent - value: '1024' newvalue: processorThrottled - uuid: 1a301ddb56ba46d38314d5c3129544b4 name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCriticalUpper - value: '5' newvalue: criticalUpper - value: '6' newvalue: nonRecoverableUpper - value: '7' newvalue: nonCriticalLower - value: '8' newvalue: criticalLower - value: '9' newvalue: nonRecoverableLower - value: '10' newvalue: failed - uuid: f3e45e2d860b48c2a6f2b7a068cac361 name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' mappings: - value: '1' newvalue: Other - value: '2' newvalue: RAID-0 - value: '3' newvalue: RAID-1 - value: '4' newvalue: RAID-5 - value: '5' newvalue: RAID-6 - value: '6' newvalue: RAID-10 - value: '7' newvalue: RAID-50 - value: '8' newvalue: RAID-60 - value: '9' newvalue: 'Concatenated RAID 1' - value: '10' newvalue: 'Concatenated RAID 5' - uuid: 6d457df3bf6646b3824ccc7be984587c name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' mappings: - value: '1' newvalue: 'Not applicable' - value: '2' newvalue: Reconstructing - value: '3' newvalue: Resynching - value: '4' newvalue: Initializing - value: '5' newvalue: 'Background init' - uuid: 47bf555344fd4fc1a15b372374bc75a7 name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' mappings: - value: '1' newvalue: 'No Read Ahead' - value: '2' newvalue: 'Read Ahead' - value: '3' newvalue: 'Adaptive Read Ahead' - uuid: 2e035bf66ff144d8ab5e0c681bb246f6 name: 'IDRAC-MIB-SMIv2::virtualDiskState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Online - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - uuid: 59eff775037e4e58925d3475ed0b0e34 name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' mappings: - value: '1' newvalue: 'Write Through' - value: '2' newvalue: 'Write Back' - value: '3' newvalue: 'Force Write Back' - uuid: 6b1b96e063084c8eb474006a9c691fb5 name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown triggers: - uuid: 93a63868ca09460e89d3f40f72259828 expression: '(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)' name: 'Dell R840: Host has been restarted' event_name: 'Dell R840: {HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes.' manual_close: 'YES' tags: - tag: scope value: notice graphs: - uuid: b0782a6e652a457b8004ae0436d2b3b0 name: 'Dell R840: Uptime' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.hw.uptime[systemPowerUpTime]' - sortorder: '1' color: F63100 item: host: 'DELL PowerEdge R840 by SNMP' key: 'dell.server.net.uptime[snmpEngineTime]'