zabbix_export:
version: '7.0'
template_groups:
- uuid: e960332b3f6c46a1956486d4f3f99fce
name: 'Templates/Server hardware'
templates:
- uuid: fc834b8da8864678b55557e9a237eac9
template: 'DELL PowerEdge R840 by SNMP'
name: 'DELL PowerEdge R840 by SNMP'
description: |
Template for DELL PowerEdge R840 servers with iDRAC version 7 and later.
MIBs used:
HOST-RESOURCES-MIB
IDRAC-MIB-SMIv2
SNMPv2-MIB
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-5
groups:
- name: 'Templates/Server hardware'
items:
- uuid: 7f08a9bf1d5540f0b05040d16d67d87a
name: 'SNMP walk RAID controllers table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]'
key: dell.server.array.controller.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.'
tags:
- tag: component
value: raw
- uuid: 39d26209dd3242c5ad90380b566c01aa
name: 'SNMP walk Battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]'
key: dell.server.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.'
tags:
- tag: component
value: raw
- uuid: 077c58fdb06c4191bf8f194b4c9108e7
name: 'BIOS version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]'
key: dell.server.bios.version
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the version name of the system BIOS.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 65da5f84a8bb43da8b72ddbe6d757fa8
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: 'dell.server.contact[sysContact]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
Name and contact information of the contact person for the node. If not provided, the value is a zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 94bcc2449dfa4bb59fd778ba96e3abdf
name: 'SNMP walk Processor device tables'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]'
key: dell.server.cpu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.'
tags:
- tag: component
value: raw
- uuid: 51c9b68b617c498eb612807734076367
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: 'dell.server.descr[sysDescr]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: c888185c08f84b059fdbf7ff0fa8eb6a
name: 'SNMP walk Physical disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]'
key: dell.server.disk.physical.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.'
tags:
- tag: component
value: raw
- uuid: f141e6e279fe4b3db65bbfe7e559389b
name: 'SNMP walk Virtual disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]'
key: dell.server.disk.virtual.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.'
tags:
- tag: component
value: raw
- uuid: d7e317cd293c4d8fa39f4283b79de6e4
name: 'SNMP walk Cooling device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]'
key: dell.server.fan.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 09e33063d84e486fb4964af35916cc25
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the firmware version of a remote access card.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 26f924a3a9e1470891cb0d9e9136ad9d
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0'
name: 'Dell R840: Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: b34415ae1ac84375834612f402d4ea0c
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]'
key: 'dell.server.hw.model[systemModelName]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the model name of the system.
inventory_link: MODEL
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: b46ad39d968141259ace337d70744001
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the service tag of the system.
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 8d1e926bb5f640b4bf8c8342b5cf1d56
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0'
name: 'Dell R840: Device has been replaced'
event_name: 'Dell R840: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: afa223e9d16b41deaac482b8328ba0e4
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
trends: '0'
units: uptime
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the power-up time of the system in seconds.
tags:
- tag: component
value: system
- uuid: 0445a9767ce34fb7b2be072609504011
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: 'dell.server.location[sysLocation]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: c84cc87d95664f66a674eefec258841a
name: 'Memory, total size'
type: CALCULATED
key: dell.server.memory.size.total
units: B
params: 'sum(last_foreach(//dell.server.memory.size[*]))'
description: 'Total memory amount on the device.'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: memory
triggers:
- uuid: c44165ebea1346c78970c1f8d96da0be
expression: 'change(/DELL PowerEdge R840 by SNMP/dell.server.memory.size.total)>0'
name: 'Dell R840: Memory amount has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags:
- tag: scope
value: availability
- uuid: 6ad434d7873f4c9e846ebaefa3e3640c
name: 'SNMP walk Memory device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]'
key: dell.server.memory.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 58be11401c084b0a81ebadbde199133d
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: 'dell.server.name[sysName]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 673eda315d9b4dfcb15509fa01fffac2
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.name[sysName]))>0'
name: 'Dell R840: System name has changed'
event_name: 'Dell R840: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 73802978c64b4d978b6e06ede9f5d760
name: 'SNMP walk Network device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]'
key: dell.server.net.if.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 49473f26fedb459c9642704bae33adb1
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]'
key: 'dell.server.net.uptime[snmpEngineTime]'
trends: '0'
units: uptime
description: |
MIB: SNMP-FRAMEWORK-MIB
The number of seconds since the value of the snmpEngineBoots object last changed.
tags:
- tag: component
value: system
- uuid: 808a099b33c6438e8fd91a4f29c41f35
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: 'dell.server.objectid[sysObjectID]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1).
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 0b013a35762f4bdab3ffeec58176779a
name: 'SNMP walk Power supply table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]'
key: dell.server.psu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.'
tags:
- tag: component
value: raw
- uuid: c2ab8a025fb34e878f7bbea9db51dbea
name: 'SNMP walk Temperature sensor table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]'
key: dell.server.sensor.temp.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 42be6e0b9fbe46179597650622a2241a
name: 'Overall system health status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]'
key: 'dell.server.status[globalSystemStatus]'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: c3e8fd8fd0d0406d8c2d9a2c45eeecee
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}'
name: 'Dell R840: System is in unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 4b32809fad0e468bb5f1bd09c7078def
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
name: 'Dell R840: System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for errors.'
tags:
- tag: scope
value: availability
- uuid: a75745134dad4592a23c43ca77975d95
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}'
name: 'Dell R840: System status is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for warnings.'
dependencies:
- name: 'Dell R840: System status is in critical state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
tags:
- tag: scope
value: availability
- uuid: 8d967ad6ac2b46c28072f713cd11b59f
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]'
key: 'dell.server.sw.os[systemOSName]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the name of the operating system that the host is running.
inventory_link: OS
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 4096c84c616743bfbfca9707e43a3db3
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.sw.os[systemOSName]))>0'
name: 'Dell R840: Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: f1068ce5a40b45ba9388e17f6dce3b79
name: 'SNMP walk System battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]'
key: dell.server.system.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.'
tags:
- tag: component
value: raw
- uuid: b5c04f5439244a87991b2b053b5f8f9b
name: 'SNMP walk Voltage probe table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]'
key: dell.server.voltage.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 074f6d9a11814bb7909d99664192421d
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: network
- uuid: b690c870c11c40ecbd162a01e82abbfe
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
description: |
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
Possible values:
0 - not available
1 - available
2 - unknown
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 6f00331597c0443a93c182a86040cca4
expression: 'max(/DELL PowerEdge R840 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0'
name: 'Dell R840: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: 23349a5dacb34beda5c745461fd2b2a9
name: 'Array controller discovery'
type: DEPENDENT
key: array.discovery
delay: '0'
description: 'Array controller discovery.'
item_prototypes:
- uuid: 9afa1fe4ec6343db9abdb7b1a6c57b10
name: 'Controller [{#CNTLR_NAME}]: Model'
type: DEPENDENT
key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The controller's name as represented in Storage Management.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
- uuid: 3af6572ca94d49da8b6c59185ddeb744
name: 'Controller [{#CNTLR_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the controller itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
trigger_prototypes:
- uuid: 149de042930a444d82d1a8016efaea2c
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
name: 'Dell R840: Controller [{#CNTLR_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
- uuid: 2fb2ddb749ed450da886420fdc5da394
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: b8cbc4a8cc404bcc83bf24af56997432
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
name: 'Dell R840: Controller [{#CNTLR_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R840: Controller [{#CNTLR_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
- name: 'Dell R840: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.array.controller.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38
- '0'
- '{#CNTLR_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 3f6ece6fbaae461bbb01f7adaeca9756
name: 'Battery discovery'
type: DEPENDENT
key: battery.discovery
delay: '0'
description: 'Battery discovery.'
item_prototypes:
- uuid: 9f78de09167d4de9b7c5f8606d8f9bb2
name: 'Battery [{#BATTERY_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Current state of battery.
Possible values:
1: The current state could not be determined.
2: The battery is operating normally.
3: The battery has failed and needs to be replaced.
4: The battery temperature is high or charge level is depleting.
5: The battery is missing or not detected.
6: The battery is undergoing the re-charge phase.
7: The battery voltage or charge level is below the threshold.
valuemap:
name: 'IDRAC-MIB-SMIv2::batteryState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.battery.walk
tags:
- tag: component
value: battery
- tag: component
value: diskarray
trigger_prototypes:
- uuid: 3624b95de99c42ac948402a4ca13a616
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 560fd4dcbf4a4ee8b49ad8880b767591
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
name: 'Dell R840: Battery [{#BATTERY_NAME}]: Not in optimal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
- name: 'Dell R840: Battery [{#BATTERY_NAME}]: Warning state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
tags:
- tag: scope
value: availability
- uuid: dc5c489632c54cf3a393cc78e50020db
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
name: 'Dell R840: Battery [{#BATTERY_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R840: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#BATTERY_NUM}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1
- '0'
- '{#BATTERY_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 3bcf2e1613ce4bcf82c8154dfa5dc7c8
name: 'CPU status discovery'
type: DEPENDENT
key: cpu.discovery
delay: '0'
description: 'CPU status discovery.'
item_prototypes:
- uuid: b5bc4152569c4d94ac18af051ac53545
name: 'CPU [{#CPU_FQDD}]: State'
type: DEPENDENT
key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the reading of the processor device status probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: 723b859cb5a94d339c7d0cba9ad2dc8d
expression: 'bitand(last(/DELL PowerEdge R840 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0'
name: 'Dell R840: CPU [{#CPU_FQDD}]: Reading error'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU probe reading flag is not `processorPresent`.
tags:
- tag: scope
value: availability
- uuid: 417e257e354542aa84741c435b7fe916
name: 'CPU [{#CPU_FQDD}]: Status'
type: DEPENDENT
key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: 66665f584f9a43c192cf995a4ef89f09
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3'
name: 'Dell R840: CPU [{#CPU_FQDD}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.cpu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#CPU_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 91a882b4c4fe48ac9224fdfb811bcf71
name: 'Fan discovery'
type: DEPENDENT
key: fan.discovery
delay: '0'
filter:
conditions:
- macro: '{#TYPE}'
value: '3'
formulaid: A
description: 'Fan discovery.'
item_prototypes:
- uuid: 8ee74a624afc41d0b607da978b2b0858
name: 'Fan [{#FAN_DESCR}]: Speed'
type: DEPENDENT
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
delay: '0'
units: rpm
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`.
When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device.
When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
- uuid: 40ffe2dbed764fab8f76ab3d77c4d48b
name: 'Fan [{#FAN_DESCR}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the cooling device.
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
trigger_prototypes:
- uuid: 4c81607b448445b7859af43eefda9c88
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
name: 'Dell R840: Fan [{#FAN_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit.'
tags:
- tag: scope
value: availability
- uuid: 9c23542532ca4414948cfaf5fb7976d2
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R840: Fan [{#FAN_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit.'
dependencies:
- name: 'Dell R840: Fan [{#FAN_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 3ca078011770494280453bce2c2198fe
name: 'Dell R840: Fan [{#FAN_DESCR}]: Speed'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
master_item:
key: dell.server.fan.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.5
- '0'
- '{#FAN_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.8
- '0'
- '{#TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.7
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: ab7d2361eeb946a48bb557e9dbc8904c
name: 'Memory discovery'
type: DEPENDENT
key: memory.discovery
delay: '0'
description: 'Memory discovery.'
item_prototypes:
- uuid: 0c87c1f952484471afad86f77c13073a
name: 'Memory [{#SNMPVALUE}]: Size'
type: DEPENDENT
key: 'dell.server.memory.size[{#SNMPVALUE}]'
delay: '0'
units: B
description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- type: MULTIPLIER
parameters:
- '1024'
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
- uuid: 2dab90151d1144fda74204e88c10067b
name: 'Memory [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.memory.status[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the memory device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
trigger_prototypes:
- uuid: 9ef225ff91114afdba9ee315c09a53c8
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3'
name: 'Dell R840: Memory [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Memory status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.memory.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 507b67db9d33407ab04b5b26eee17f33
name: 'Network interface discovery'
type: DEPENDENT
key: net.if.discovery
delay: '0'
description: 'Discovery of network interfaces.'
item_prototypes:
- uuid: 3400e8c414144a88baed85ccd1179008
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status'
type: DEPENDENT
key: 'dell.server.net.if.link[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the connection status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: 1fe39881ec004b87a41c1d8d44479981
expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0'
name: 'Dell R840: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is Down.
2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down.
3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.)
manual_close: 'YES'
tags:
- tag: scope
value: availability
- uuid: 1e3ec0d9d8284aed8edeff4490afe605
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status'
type: DEPENDENT
key: 'dell.server.net.if.status[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: 5196e2886545427dbafe649cb3cd651f
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3'
name: 'Dell R840: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Network interface status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.net.if.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#NIC_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1
- '0'
- '{#NIC_MAC}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1
- '2'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: d9c26b4a06bc45acb742315896b358da
name: 'Physical disk discovery'
type: DEPENDENT
key: physicaldisk.discovery
delay: '0'
description: 'Physical disk discovery.'
item_prototypes:
- uuid: be048b1285ba4a21a14e5f79727c2b91
name: 'Physical disk [{#DISK_NAME}]: Media type'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The media type of the physical disk. Possible Values:
1: The media type could not be determined.
2: Hard Disk Drive (HDD).
3: Solid State Drive (SSD).
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 79fa0faedeb743c1a9f9c0ea0d454935
name: 'Physical disk [{#DISK_NAME}]: Model name'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The model number of the physical disk.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: b2668345145f4d638dbb364afbdfb9f8
name: 'Physical disk [{#DISK_NAME}]: Serial number'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The physical disk's unique identification number from the manufacturer.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 7d2a1a115b304ca5823618360675d43d
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0'
name: 'Dell R840: Physical disk [{#DISK_NAME}] has been replaced'
event_name: 'Dell R840: [{#DISK_NAME}] has been replaced (new serial number received)'
priority: INFO
description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 6e50bc2fa3ee4ceeb8fe044a7d83f836
name: 'Physical disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the physical disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 3a2cd6a4c4ea4a3ab4ccbd555ee17f5b
name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Indicates whether the physical disk has received a predictive failure alert.
valuemap:
name: 'IDRAC-MIB-SMIv2::BooleanType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 3a648ce450cd4236bcda1b48f6cb840f
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}'
name: 'Dell R840: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Disk probably requires replacement.'
dependencies:
- name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
- uuid: fbb5d836a0c344e0929bb406cf9721ee
name: 'Physical disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the physical disk itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 426d1d50afb04253b92a5b99c9e96206
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check physical disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: 1d0a3f13c2fd4bc8be2c4305850c984c
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
name: 'Dell R840: Physical disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check physical disk for warnings or errors.'
dependencies:
- name: 'Dell R840: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 2b64a7034bb3455196e2716e622ce404
name: 'Dell R840: Physical disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.physical.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: d95e02ed8c204fe1b4edf5a3d3ad3847
name: 'PSU discovery'
type: DEPENDENT
key: psu.discovery
delay: '0'
description: 'PSU discovery.'
item_prototypes:
- uuid: fe99911125c54800be75e332c150356b
name: 'Power supply [{#PSU_DESCR}]: State'
type: DEPENDENT
key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the status of the power supply.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.psu.walk
tags:
- tag: component
value: psu
trigger_prototypes:
- uuid: 519b5f4f8c6f4b6b92eafb910c1e81eb
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
name: 'Dell R840: Power supply [{#PSU_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors.'
tags:
- tag: scope
value: availability
- uuid: 76ab0ba99e424e43b686d11049b40258
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
name: 'Dell R840: Power supply [{#PSU_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors.'
dependencies:
- name: 'Dell R840: Power supply [{#PSU_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.psu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
- '0'
- '{#PSU_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 1461820b857d483e9988434b36a9cf6f
name: 'System battery discovery'
type: DEPENDENT
key: system.battery.discovery
delay: '0'
description: 'System battery discovery.'
item_prototypes:
- uuid: b4c42aaf69b34fcaa8ff8a23f0767c3a
name: 'System battery [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.system.battery[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the battery.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.system.battery.walk
tags:
- tag: component
value: battery
trigger_prototypes:
- uuid: 9cc273d913d04f58af291d888fd942ff
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3'
name: 'Dell R840: System battery [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
System battery status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.system.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: e9897a4e0d9d41e38e1cfd198f94d2de
name: 'Temperature discovery'
type: DEPENDENT
key: temp.discovery
delay: '0'
description: 'Temperature sensor discovery.'
item_prototypes:
- uuid: c76c966651f940a5ac664c75c88ca689
name: 'Probe [{#SENSOR_LOCALE}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the temperature probe.
Possible values:
other(1), -- probe status is not one of the following:
unknown(2), -- probe status is unknown (not known or monitored)
ok(3), -- probe is reporting a value within the thresholds
nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold
criticalUpper(5), -- probe has crossed the upper critical threshold
nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold
nonCriticalLower(7), -- probe has crossed the lower noncritical threshold
criticalLower(8), -- probe has crossed the lower critical threshold
nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold
failed(10) -- probe is not functional
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: d1e14d635c0945298c5319380f8ac2f9
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 567f74a71047410c9dcb8d70298160b1
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Not in optimal status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
manual_close: 'YES'
dependencies:
- name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
- name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Warning status'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
tags:
- tag: scope
value: notice
- uuid: da4cdf74306947e7a6d394cca92c8c70
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Warning status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R840 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
tags:
- tag: scope
value: availability
- uuid: e498e0b6adca49048b27fcde07880661
name: 'Probe [{#SENSOR_LOCALE}]: Value'
type: DEPENDENT
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
units: °C
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`.
When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade.
When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.1'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
graph_prototypes:
- uuid: aec83bed731d402a841088d092bd6400
name: 'Dell R840: Probe [{#SENSOR_LOCALE}]: Value'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
master_item:
key: dell.server.sensor.temp.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
- '0'
- '{#SENSOR_LOCALE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 9e2d2bc270704e8eb646b55a7f4e377e
name: 'Virtual disk discovery'
type: DEPENDENT
key: virtualdisk.discovery
delay: '0'
description: 'Virtual disk discovery.'
item_prototypes:
- uuid: 27bb804aa7df49ddbc410b268db63218
name: 'Virtual disk [{#DISK_NAME}]: Layout type'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The virtual disk's RAID type.
Possible values:
1: Not one of the following
2: RAID-0
3: RAID-1
4: RAID-5
5: RAID-6
6: RAID-10
7: RAID-50
8: RAID-60
9: Concatenated RAID 1
10: Concatenated RAID 5
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 109cd4fc0cc24a6586a282272b8448bb
name: 'Virtual disk [{#DISK_NAME}]: Read policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The read policy used by the controller for read operations on this virtual disk.
Possible values:
1: No Read Ahead.
2: Read Ahead.
3: Adaptive Read Ahead.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: e4868bd552d34f79823d3c7518babad8
name: 'Virtual disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the virtual disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: cf12e14b376940189873430fdfa64c49
name: 'Virtual disk [{#DISK_NAME}]: Operational state'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The state of the virtual disk when there are progressive operations ongoing.
Possible values:
1: There is no active operation running.
2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.
3: A Consistency Check (CC) is being performed on the virtual disk.
4: The virtual disk is being initialized.
5: BackGround Initialization (BGI) is being performed on the virtual disk.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 3m
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 344be656d8d84bbca28853d240f5953f
name: 'Virtual disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The current state of this virtual disk (which includes any member physical disks.)
Possible states:
1: The current state could not be determined.
2: The virtual disk is operating normally or optimally.
3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost.
4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.
The data on the virtual disk might no longer be fault tolerant.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
trigger_prototypes:
- uuid: 443b942a8ea64600a6b1bdda2bb75ec3
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Failed state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the virtual disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: be479b50bc2c4320afff5eef0292bc88
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the virtual disk for warnings or errors.'
dependencies:
- name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
- uuid: db4f2a2abead4efba3d54124b2e992f7
name: 'Virtual disk [{#DISK_NAME}]: Write policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The write policy used by the controller for write operations on this virtual disk.
Possible values:
1: Write Through.
2: Write Back.
3: Force Write Back.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
graph_prototypes:
- uuid: 630725a2e858465ba6c3a6b5b8982d93
name: 'Dell R840: Virtual disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.virtual.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 43169b68868240d589e8c87bba94ce86
name: 'Voltage probe discovery'
type: DEPENDENT
key: voltage.discovery
delay: '0'
filter:
evaltype: AND
conditions:
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
formulaid: A
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
formulaid: C
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
description: 'Voltage probe discovery.'
item_prototypes:
- uuid: d8a499c3a77741d39e4108469009f9b0
name: 'Voltage probe [{#VPROBE_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.voltage.status[{#VPROBE_NAME}]'
delay: '0'
description: 'This attribute defines the status of the voltage probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
trigger_prototypes:
- uuid: 74ee37bcbbcc4122814912218889da61
expression: 'last(/DELL PowerEdge R840 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3'
name: 'Dell R840: Voltage probe [{#VPROBE_NAME}]: Status is not OK'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device''s voltage.'
tags:
- tag: scope
value: availability
- uuid: 7379dd15da4e48f295ab466eb45895da
name: 'Voltage probe [{#VPROBE_NAME}]: Voltage'
type: DEPENDENT
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
delay: '0'
value_type: FLOAT
units: V
description: 'This attribute defines the reading for a voltage probe.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.001'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
graph_prototypes:
- uuid: c40ac46b891f4ed892c532c8ff73ea50
name: 'Dell R840: Voltage probe [{#VPROBE_NAME}]: Voltage'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
master_item:
key: dell.server.voltage.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#VPROBE_NAME}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1
- '0'
- '{#VPROBE_TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: class
value: hardware
- tag: target
value: dell
- tag: target
value: 'dell poweredge'
macros:
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
value: '^.*Voltage.*$'
description: 'Sets the regex string of voltage probe names to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe names to ignore in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
value: 18|16
description: 'Sets the regex string of voltage probe types to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe types to ignore in discovery.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
value: '3'
description: 'The critical status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
value: '2'
description: 'The OK status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
value: '5'
description: 'The critical status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
value: '6'
description: 'The disaster status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}'
value: '1'
description: 'The critical S.M.A.R.T status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}'
value: '5'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
value: '6'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
value: '10'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}'
value: '5'
description: 'The critical status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}'
value: '6'
description: 'The disaster status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}'
value: '4'
description: 'The warning status of health for the trigger expression.'
- macro: '{$DELL.SNMP.IFCONTROL}'
value: '1'
description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}'
value: '5'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
value: '6'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
value: '3'
description: 'The OK status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for the SNMP agent availability trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
value: '3'
description: 'The critical status of the virtual disk for the trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
value: '4'
description: 'The warning status of the virtual disk for the trigger expression.'
dashboards:
- uuid: 05115b5959dd46e4aa916b6a13cf2e6b
name: Overview
pages:
- name: Overview
display_period: '30'
widgets:
- type: item
name: 'System health'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'System Health'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.status[globalSystemStatus]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'Serial number'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'Serial number'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'HW model'
x: '36'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'HW model'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.hw.model[systemModelName]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: Firmware
x: '36'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: Firmware
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- name: Discoveries
display_period: '30'
widgets:
- type: honeycomb
name: 'Interface link'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'NIC*Link status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAA
- type: STRING
name: thresholds.0.color
value: 069C56
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: FF681E
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: 'Temperature sensors'
'y': '4'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Probe*Value'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAB
- type: INTEGER
name: secondary_label_decimal_places
value: '0'
- type: honeycomb
name: 'Physical disks'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Physical disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAC
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
- type: honeycomb
name: 'Power supplies'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Voltage probe*Voltage'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAE
- type: honeycomb
name: 'Virtual disks'
x: '36'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Virtual disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAD
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: Fans
x: '36'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Fan*Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAF
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
valuemaps:
- uuid: 692c968229d64965b3f6c59ca79b4522
name: 'IDRAC-MIB-SMIv2::batteryState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Ready
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- value: '5'
newvalue: Missing
- value: '6'
newvalue: Charging
- value: '7'
newvalue: 'Below threshold'
- uuid: 1ee27c8f7c9d4f7cbafc8c7567b70c67
name: 'IDRAC-MIB-SMIv2::BooleanType'
mappings:
- value: '0'
newvalue: ok
- value: '1'
newvalue: failed
- uuid: a866da3a7c4e43d086efafb07178f8ec
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
mappings:
- value: '0'
newvalue: unknown
- value: '1'
newvalue: connected
- value: '2'
newvalue: disconnected
- value: '3'
newvalue: driverBad
- value: '4'
newvalue: driverDisabled
- value: '10'
newvalue: hardwareInitalizing
- value: '11'
newvalue: hardwareResetting
- value: '12'
newvalue: hardwareClosing
- value: '13'
newvalue: hardwareNotReady
- uuid: c238adb07fea463a8cb21f962fcb24d9
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: ee4ff377e3984685993e230911e6c13e
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: 7409409d584845e39579b478171a600a
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: HDD
- value: '3'
newvalue: SSD
- uuid: 092b816c537e4fe79c7f5826037c5872
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
mappings:
- value: '1'
newvalue: internalError
- value: '2'
newvalue: thermalTrip
- value: '32'
newvalue: configurationError
- value: '128'
newvalue: processorPresent
- value: '256'
newvalue: processorDisabled
- value: '512'
newvalue: terminatorPresent
- value: '1024'
newvalue: processorThrottled
- uuid: 1a301ddb56ba46d38314d5c3129544b4
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCriticalUpper
- value: '5'
newvalue: criticalUpper
- value: '6'
newvalue: nonRecoverableUpper
- value: '7'
newvalue: nonCriticalLower
- value: '8'
newvalue: criticalLower
- value: '9'
newvalue: nonRecoverableLower
- value: '10'
newvalue: failed
- uuid: f3e45e2d860b48c2a6f2b7a068cac361
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
mappings:
- value: '1'
newvalue: Other
- value: '2'
newvalue: RAID-0
- value: '3'
newvalue: RAID-1
- value: '4'
newvalue: RAID-5
- value: '5'
newvalue: RAID-6
- value: '6'
newvalue: RAID-10
- value: '7'
newvalue: RAID-50
- value: '8'
newvalue: RAID-60
- value: '9'
newvalue: 'Concatenated RAID 1'
- value: '10'
newvalue: 'Concatenated RAID 5'
- uuid: 6d457df3bf6646b3824ccc7be984587c
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
mappings:
- value: '1'
newvalue: 'Not applicable'
- value: '2'
newvalue: Reconstructing
- value: '3'
newvalue: Resynching
- value: '4'
newvalue: Initializing
- value: '5'
newvalue: 'Background init'
- uuid: 47bf555344fd4fc1a15b372374bc75a7
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
mappings:
- value: '1'
newvalue: 'No Read Ahead'
- value: '2'
newvalue: 'Read Ahead'
- value: '3'
newvalue: 'Adaptive Read Ahead'
- uuid: 2e035bf66ff144d8ab5e0c681bb246f6
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Online
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- uuid: 59eff775037e4e58925d3475ed0b0e34
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
mappings:
- value: '1'
newvalue: 'Write Through'
- value: '2'
newvalue: 'Write Back'
- value: '3'
newvalue: 'Force Write Back'
- uuid: 6b1b96e063084c8eb474006a9c691fb5
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 93a63868ca09460e89d3f40f72259828
expression: '(last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R840 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R840 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)'
name: 'Dell R840: Host has been restarted'
event_name: 'Dell R840: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
graphs:
- uuid: b0782a6e652a457b8004ae0436d2b3b0
name: 'Dell R840: Uptime'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R840 by SNMP'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
- sortorder: '1'
color: F63100
item:
host: 'DELL PowerEdge R840 by SNMP'