zabbix_export:
version: '7.0'
template_groups:
- uuid: e960332b3f6c46a1956486d4f3f99fce
name: 'Templates/Server hardware'
templates:
- uuid: fe5b8448661f41b9a6d948fccd7f9045
template: 'DELL PowerEdge R720 by SNMP'
name: 'DELL PowerEdge R720 by SNMP'
description: |
Template for DELL PowerEdge R720 servers with iDRAC version 7 and later.
MIBs used:
HOST-RESOURCES-MIB
IDRAC-MIB-SMIv2
SNMPv2-MIB
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-5
groups:
- name: 'Templates/Server hardware'
items:
- uuid: 93c5649909334a61ba0414fe7e0063a3
name: 'SNMP walk RAID controllers table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]'
key: dell.server.array.controller.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.'
tags:
- tag: component
value: raw
- uuid: 34a1321bf79841a2a600b11e12d3cef1
name: 'SNMP walk Battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]'
key: dell.server.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.'
tags:
- tag: component
value: raw
- uuid: 5e8cd7ff8b5b4ac796147f72087ea925
name: 'BIOS version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]'
key: dell.server.bios.version
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the version name of the system BIOS.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: cd86d6203a874b27be4ed91578928dcf
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: 'dell.server.contact[sysContact]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
Name and contact information of the contact person for the node. If not provided, the value is a zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 4f2fabba628e45ab9dc8627e32e9a35a
name: 'SNMP walk Processor device tables'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]'
key: dell.server.cpu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.'
tags:
- tag: component
value: raw
- uuid: d5c65ffddfff45319a3f6ba856b73f6b
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: 'dell.server.descr[sysDescr]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 9773c82f46a6485992049843de57de3e
name: 'SNMP walk Physical disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]'
key: dell.server.disk.physical.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.'
tags:
- tag: component
value: raw
- uuid: bf3b1c74945f40549ddd4688250846e1
name: 'SNMP walk Virtual disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]'
key: dell.server.disk.virtual.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.'
tags:
- tag: component
value: raw
- uuid: 5e06ce9f690c4671bf0fbf38aa6e3b89
name: 'SNMP walk Cooling device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]'
key: dell.server.fan.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 00928da92ab7499aba169837b2fffc83
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the firmware version of a remote access card.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 46c22d9eca174756903b8c26ec69c792
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0'
name: 'Dell R720: Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 34fd8f0eaae041828cd1743ef55c16f9
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]'
key: 'dell.server.hw.model[systemModelName]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the model name of the system.
inventory_link: MODEL
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: f5753d89e11f43fba46959b60601d45c
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the service tag of the system.
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 1e3f0933fae74fc29c13177fe2cf6903
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0'
name: 'Dell R720: Device has been replaced'
event_name: 'Dell R720: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 3240487059234b49bb822113c1964693
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
trends: '0'
units: uptime
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the power-up time of the system in seconds.
tags:
- tag: component
value: system
- uuid: ca9019fd89654c52889a12153150151d
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: 'dell.server.location[sysLocation]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: beac13b3dfa04b0a9edf1a01e559021e
name: 'Memory, total size'
type: CALCULATED
key: dell.server.memory.size.total
units: B
params: 'sum(last_foreach(//dell.server.memory.size[*]))'
description: 'Total memory amount on the device.'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: memory
triggers:
- uuid: deb6d163f8824e489d9e64674d648d80
expression: 'change(/DELL PowerEdge R720 by SNMP/dell.server.memory.size.total)>0'
name: 'Dell R720: Memory amount has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags:
- tag: scope
value: availability
- uuid: 84267fb8555d48398b661bce37be8a74
name: 'SNMP walk Memory device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]'
key: dell.server.memory.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 8b72816906274e1281929a318c44e8c6
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: 'dell.server.name[sysName]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 12327b9851254d28b1db193fbca51f9a
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.name[sysName]))>0'
name: 'Dell R720: System name has changed'
event_name: 'Dell R720: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 2d273acf4bb646d7a3ca9602d7b529af
name: 'SNMP walk Network device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]'
key: dell.server.net.if.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 767944c5d9e0470580f813948d9dbe96
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]'
key: 'dell.server.net.uptime[snmpEngineTime]'
trends: '0'
units: uptime
description: |
MIB: SNMP-FRAMEWORK-MIB
The number of seconds since the value of the snmpEngineBoots object last changed.
tags:
- tag: component
value: system
- uuid: 18c324fe6e714549bc337c2711795c40
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: 'dell.server.objectid[sysObjectID]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1).
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: a5b4a818eeb04e1fb072b3b8e76441f3
name: 'SNMP walk Power supply table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]'
key: dell.server.psu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.'
tags:
- tag: component
value: raw
- uuid: 6f407f3ff09f48179075f54eb26604db
name: 'SNMP walk Temperature sensor table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]'
key: dell.server.sensor.temp.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 341699ea98c64951b1d94d89b5c81362
name: 'Overall system health status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]'
key: 'dell.server.status[globalSystemStatus]'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 7b6bbbaf7a6f4ba084e812fc98aee033
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}'
name: 'Dell R720: System is in unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 51bd134f73234388b1c9522468b73883
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
name: 'Dell R720: System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for errors.'
tags:
- tag: scope
value: availability
- uuid: e026d877c5e540b9ae06d44874e7ec5d
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}'
name: 'Dell R720: System status is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for warnings.'
dependencies:
- name: 'Dell R720: System status is in critical state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
tags:
- tag: scope
value: availability
- uuid: c8d519bdde9a4c3b89976f7b0dab0696
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]'
key: 'dell.server.sw.os[systemOSName]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the name of the operating system that the host is running.
inventory_link: OS
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 2e07d3f10a114360b4189e47cfd777f8
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.sw.os[systemOSName]))>0'
name: 'Dell R720: Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 8cb0cacb3ca144d2b917ea457ef3ba24
name: 'SNMP walk System battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]'
key: dell.server.system.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.'
tags:
- tag: component
value: raw
- uuid: 5f7dc7b0c23c40e4b8442ae1223d70d5
name: 'SNMP walk Voltage probe table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]'
key: dell.server.voltage.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 65097a06ef764129bcb0cb7fdd1f0ec8
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: network
- uuid: 943b9c35a40c4ca7811212b20b27677d
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
description: |
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
Possible values:
0 - not available
1 - available
2 - unknown
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: f0b0662e38cd4aa6893dc3b5f89b9c81
expression: 'max(/DELL PowerEdge R720 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0'
name: 'Dell R720: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: b61fe289fe88450db55f03c632e8a26f
name: 'Array controller discovery'
type: DEPENDENT
key: array.discovery
delay: '0'
description: 'Array controller discovery.'
item_prototypes:
- uuid: 0f565dd530fa4a0bb93b642c8ee19b0f
name: 'Controller [{#CNTLR_NAME}]: Model'
type: DEPENDENT
key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The controller's name as represented in Storage Management.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
- uuid: 69ed8def6e2c4025abcc565217064600
name: 'Controller [{#CNTLR_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the controller itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
trigger_prototypes:
- uuid: c9298bbaac134cc39e268d0b94051fcc
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
name: 'Dell R720: Controller [{#CNTLR_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R720: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
- uuid: 69ff155a6ecd4b709a1579641a711283
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
name: 'Dell R720: Controller [{#CNTLR_NAME}]: Unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: ddb5bca1ce3b45fa8da9197d4ac0f758
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
name: 'Dell R720: Controller [{#CNTLR_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R720: Controller [{#CNTLR_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
- name: 'Dell R720: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.array.controller.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38
- '0'
- '{#CNTLR_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: ed881938a95c4be2b9c7f0d548696f27
name: 'Battery discovery'
type: DEPENDENT
key: battery.discovery
delay: '0'
description: 'Battery discovery.'
item_prototypes:
- uuid: 9444982ba8cf4c70a03a780fab18a36a
name: 'Battery [{#BATTERY_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Current state of battery.
Possible values:
1: The current state could not be determined.
2: The battery is operating normally.
3: The battery has failed and needs to be replaced.
4: The battery temperature is high or charge level is depleting.
5: The battery is missing or not detected.
6: The battery is undergoing the re-charge phase.
7: The battery voltage or charge level is below the threshold.
valuemap:
name: 'IDRAC-MIB-SMIv2::batteryState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.battery.walk
tags:
- tag: component
value: battery
- tag: component
value: diskarray
trigger_prototypes:
- uuid: 7c3cb436445949b5a28368cf4ce00fdc
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
name: 'Dell R720: Battery [{#BATTERY_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 8cd73ebf8055426883d8301ceeca51de
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
name: 'Dell R720: Battery [{#BATTERY_NAME}]: Not in optimal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R720: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
- name: 'Dell R720: Battery [{#BATTERY_NAME}]: Warning state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
tags:
- tag: scope
value: availability
- uuid: 893e3d8d04e841058eafa43752546f1c
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
name: 'Dell R720: Battery [{#BATTERY_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R720: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#BATTERY_NUM}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1
- '0'
- '{#BATTERY_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 6df0976045b942b8986b8c3a46c2fde4
name: 'CPU status discovery'
type: DEPENDENT
key: cpu.discovery
delay: '0'
description: 'CPU status discovery.'
item_prototypes:
- uuid: 668835ea1b0a4146a6296d298a9f1607
name: 'CPU [{#CPU_FQDD}]: State'
type: DEPENDENT
key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the reading of the processor device status probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: 1f919ce7df874574b764d1c3f17ed693
expression: 'bitand(last(/DELL PowerEdge R720 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0'
name: 'Dell R720: CPU [{#CPU_FQDD}]: Reading error'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU probe reading flag is not `processorPresent`.
tags:
- tag: scope
value: availability
- uuid: 201313c89ba245a794e5e76778c0dfa4
name: 'CPU [{#CPU_FQDD}]: Status'
type: DEPENDENT
key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: 54f006add0c7435b8cabaa361d8eb27e
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3'
name: 'Dell R720: CPU [{#CPU_FQDD}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.cpu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#CPU_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: c0c2f9b115f04ebe8b709032f8c97669
name: 'Fan discovery'
type: DEPENDENT
key: fan.discovery
delay: '0'
filter:
conditions:
- macro: '{#TYPE}'
value: '3'
formulaid: A
description: 'Fan discovery.'
item_prototypes:
- uuid: fdd01d80c11e41e3aa1c8975b4f2b926
name: 'Fan [{#FAN_DESCR}]: Speed'
type: DEPENDENT
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
delay: '0'
units: rpm
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`.
When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device.
When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
- uuid: 028a4cd49fd04e92aac769f4e38a40c9
name: 'Fan [{#FAN_DESCR}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the cooling device.
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
trigger_prototypes:
- uuid: 20e8c5ad48a44748a5223aa1f2c391dc
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
name: 'Dell R720: Fan [{#FAN_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit.'
tags:
- tag: scope
value: availability
- uuid: 791e1a7e913c467fb93209e75e33e7ca
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R720: Fan [{#FAN_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit.'
dependencies:
- name: 'Dell R720: Fan [{#FAN_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 32ac4de62079442c839ac548abd71e52
name: 'Dell R720: Fan [{#FAN_DESCR}]: Speed'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
master_item:
key: dell.server.fan.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.5
- '0'
- '{#FAN_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.8
- '0'
- '{#TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.7
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: c5603b825445457c8b39662df9fd7db8
name: 'Memory discovery'
type: DEPENDENT
key: memory.discovery
delay: '0'
description: 'Memory discovery.'
item_prototypes:
- uuid: 4c857762cecb45fe8bb545b5cc786d9c
name: 'Memory [{#SNMPVALUE}]: Size'
type: DEPENDENT
key: 'dell.server.memory.size[{#SNMPVALUE}]'
delay: '0'
units: B
description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- type: MULTIPLIER
parameters:
- '1024'
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
- uuid: c692910b52774a33aabaff78e46cc855
name: 'Memory [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.memory.status[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the memory device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
trigger_prototypes:
- uuid: a2ba71923e31415ead86dc46fd7e665e
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3'
name: 'Dell R720: Memory [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Memory status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.memory.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 669b97ebc2464988857a2496af5652a0
name: 'Network interface discovery'
type: DEPENDENT
key: net.if.discovery
delay: '0'
description: 'Discovery of network interfaces.'
item_prototypes:
- uuid: e6728405f5c64aec8822190e868625d3
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status'
type: DEPENDENT
key: 'dell.server.net.if.link[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the connection status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: a5455d074ae94d7daa4eb11d345e33fb
expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0'
name: 'Dell R720: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is Down.
2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down.
3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.)
manual_close: 'YES'
tags:
- tag: scope
value: availability
- uuid: 396dee5189a14314a861a04d9a0dcacc
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status'
type: DEPENDENT
key: 'dell.server.net.if.status[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: a56df48040fd4ffcb6401cc7a407d303
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3'
name: 'Dell R720: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Network interface status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.net.if.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#NIC_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1
- '0'
- '{#NIC_MAC}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1
- '2'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: ed21036b0df047f5924df6ed4fd53b62
name: 'Physical disk discovery'
type: DEPENDENT
key: physicaldisk.discovery
delay: '0'
description: 'Physical disk discovery.'
item_prototypes:
- uuid: 6830d155acf647fd990822137efa9d02
name: 'Physical disk [{#DISK_NAME}]: Media type'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The media type of the physical disk. Possible Values:
1: The media type could not be determined.
2: Hard Disk Drive (HDD).
3: Solid State Drive (SSD).
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 3cae98ed317a43e7920d4ae9106fe9cd
name: 'Physical disk [{#DISK_NAME}]: Model name'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The model number of the physical disk.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 27f4105ce0c24d9f8509f71b59ce8714
name: 'Physical disk [{#DISK_NAME}]: Serial number'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The physical disk's unique identification number from the manufacturer.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 74b1394597ce4036b9eef76db92a9ac7
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0'
name: 'Dell R720: Physical disk [{#DISK_NAME}] has been replaced'
event_name: 'Dell R720: [{#DISK_NAME}] has been replaced (new serial number received)'
priority: INFO
description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 20d406f393fc4a6b9963569d24a02106
name: 'Physical disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the physical disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: aa58b1d10ae8498a9f6ca736e083ec91
name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Indicates whether the physical disk has received a predictive failure alert.
valuemap:
name: 'IDRAC-MIB-SMIv2::BooleanType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 85205e77583b4d82b408fd1bedb6e680
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}'
name: 'Dell R720: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Disk probably requires replacement.'
dependencies:
- name: 'Dell R720: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
- uuid: 551bee86234a4c99a6c7c5ac7db89f37
name: 'Physical disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the physical disk itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 899cfe68ef4f4a8abf841c7efb7448a7
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
name: 'Dell R720: Physical disk [{#DISK_NAME}]: Failed state'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check physical disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: aaeaa0c4d26d4f8d878517efff99c624
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
name: 'Dell R720: Physical disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check physical disk for warnings or errors.'
dependencies:
- name: 'Dell R720: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 3b54483c46bb4038a3fb60070b1ab41b
name: 'Dell R720: Physical disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.physical.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 166c453303e843bbadc62963b725da95
name: 'PSU discovery'
type: DEPENDENT
key: psu.discovery
delay: '0'
description: 'PSU discovery.'
item_prototypes:
- uuid: 43fe09a202994622bbef420c9b018d49
name: 'Power supply [{#PSU_DESCR}]: State'
type: DEPENDENT
key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the status of the power supply.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.psu.walk
tags:
- tag: component
value: psu
trigger_prototypes:
- uuid: c3141535717d439fa74ffe068b0c61d5
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
name: 'Dell R720: Power supply [{#PSU_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors.'
tags:
- tag: scope
value: availability
- uuid: 9b0d4e804b0c4918a7c3660f8772bc88
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
name: 'Dell R720: Power supply [{#PSU_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors.'
dependencies:
- name: 'Dell R720: Power supply [{#PSU_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.psu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
- '0'
- '{#PSU_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 28b27d2152814dda9a9fef602ec78b38
name: 'System battery discovery'
type: DEPENDENT
key: system.battery.discovery
delay: '0'
description: 'System battery discovery.'
item_prototypes:
- uuid: 89887fe6674e42ac985018f1da7c86e0
name: 'System battery [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.system.battery[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the battery.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.system.battery.walk
tags:
- tag: component
value: battery
trigger_prototypes:
- uuid: d61b5c42fbe9451fb02e66cb65682a3d
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3'
name: 'Dell R720: System battery [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
System battery status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.system.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 8e29bd2cab71430b8306394b6f629ac2
name: 'Temperature discovery'
type: DEPENDENT
key: temp.discovery
delay: '0'
description: 'Temperature sensor discovery.'
item_prototypes:
- uuid: 8933cb6596154baca790294c37d0a3b9
name: 'Probe [{#SENSOR_LOCALE}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the temperature probe.
Possible values:
other(1), -- probe status is not one of the following:
unknown(2), -- probe status is unknown (not known or monitored)
ok(3), -- probe is reporting a value within the thresholds
nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold
criticalUpper(5), -- probe has crossed the upper critical threshold
nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold
nonCriticalLower(7), -- probe has crossed the lower noncritical threshold
criticalLower(8), -- probe has crossed the lower critical threshold
nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold
failed(10) -- probe is not functional
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 6c9f6edf352f458a96ab3e388307afd6
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Critical status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: a897d28f37914cad92faaa3ffb218463
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Not in optimal status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
manual_close: 'YES'
dependencies:
- name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
- name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Warning status'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
tags:
- tag: scope
value: notice
- uuid: 44b9519b16e441028e7af08ae1ec4942
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Warning status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
tags:
- tag: scope
value: availability
- uuid: 9c03b7da06874b69a43943de63912d82
name: 'Probe [{#SENSOR_LOCALE}]: Value'
type: DEPENDENT
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
units: °C
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`.
When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade.
When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.1'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
graph_prototypes:
- uuid: 857150f6f2ff4fec9fb80e3235adb830
name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Value'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
master_item:
key: dell.server.sensor.temp.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
- '0'
- '{#SENSOR_LOCALE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 4332291ca425477387bed6abccaaefd3
name: 'Virtual disk discovery'
type: DEPENDENT
key: virtualdisk.discovery
delay: '0'
description: 'Virtual disk discovery.'
item_prototypes:
- uuid: 6f63f8bbeba44c3a85a874f6e2796b26
name: 'Virtual disk [{#DISK_NAME}]: Layout type'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The virtual disk's RAID type.
Possible values:
1: Not one of the following
2: RAID-0
3: RAID-1
4: RAID-5
5: RAID-6
6: RAID-10
7: RAID-50
8: RAID-60
9: Concatenated RAID 1
10: Concatenated RAID 5
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 9bcd5c8774d64293a3c03135df0026bf
name: 'Virtual disk [{#DISK_NAME}]: Read policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The read policy used by the controller for read operations on this virtual disk.
Possible values:
1: No Read Ahead.
2: Read Ahead.
3: Adaptive Read Ahead.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: f52835c258ea4b2ab16ab91fa14f2cd9
name: 'Virtual disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the virtual disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 100faa8a115f4f34a61938fc9fe2b056
name: 'Virtual disk [{#DISK_NAME}]: Operational state'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The state of the virtual disk when there are progressive operations ongoing.
Possible values:
1: There is no active operation running.
2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.
3: A Consistency Check (CC) is being performed on the virtual disk.
4: The virtual disk is being initialized.
5: BackGround Initialization (BGI) is being performed on the virtual disk.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 3m
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 9f49cd360dc849d19abe10cd5cf94a10
name: 'Virtual disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The current state of this virtual disk (which includes any member physical disks.)
Possible states:
1: The current state could not be determined.
2: The virtual disk is operating normally or optimally.
3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost.
4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.
The data on the virtual disk might no longer be fault tolerant.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
trigger_prototypes:
- uuid: 0bd27a473d694b9c8ddb59fe2711608a
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
name: 'Dell R720: Virtual disk [{#DISK_NAME}]: Failed state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the virtual disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: 7ca47e8ba4a549b2a799d4e78adf5add
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
name: 'Dell R720: Virtual disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the virtual disk for warnings or errors.'
dependencies:
- name: 'Dell R720: Virtual disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
- uuid: d599f3c67807443b82c9ec83af325142
name: 'Virtual disk [{#DISK_NAME}]: Write policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The write policy used by the controller for write operations on this virtual disk.
Possible values:
1: Write Through.
2: Write Back.
3: Force Write Back.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
graph_prototypes:
- uuid: 7f5fdaf45edf49f4bde8c86147949c50
name: 'Dell R720: Virtual disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.virtual.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 1aa767e3c91e427ebd508df8e49f89dd
name: 'Voltage probe discovery'
type: DEPENDENT
key: voltage.discovery
delay: '0'
filter:
evaltype: AND
conditions:
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
formulaid: A
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
formulaid: C
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
description: 'Voltage probe discovery.'
item_prototypes:
- uuid: 2b9a84f4a7fb429081a22394ba9ef81f
name: 'Voltage probe [{#VPROBE_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.voltage.status[{#VPROBE_NAME}]'
delay: '0'
description: 'This attribute defines the status of the voltage probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
trigger_prototypes:
- uuid: 68360a834efd4d0188a9d58d01b9429a
expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3'
name: 'Dell R720: Voltage probe [{#VPROBE_NAME}]: Status is not OK'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device''s voltage.'
tags:
- tag: scope
value: availability
- uuid: 053c9f3e14cc438795b0a7911ab57854
name: 'Voltage probe [{#VPROBE_NAME}]: Voltage'
type: DEPENDENT
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
delay: '0'
value_type: FLOAT
units: V
description: 'This attribute defines the reading for a voltage probe.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.001'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
graph_prototypes:
- uuid: 441e248166f64944aec3abc9e296c980
name: 'Dell R720: Voltage probe [{#VPROBE_NAME}]: Voltage'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
master_item:
key: dell.server.voltage.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#VPROBE_NAME}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1
- '0'
- '{#VPROBE_TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: class
value: hardware
- tag: target
value: dell
- tag: target
value: 'dell poweredge'
macros:
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
value: '^.*Voltage.*$'
description: 'Sets the regex string of voltage probe names to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe names to ignore in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
value: 18|16
description: 'Sets the regex string of voltage probe types to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe types to ignore in discovery.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
value: '3'
description: 'The critical status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
value: '2'
description: 'The OK status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
value: '5'
description: 'The critical status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
value: '6'
description: 'The disaster status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}'
value: '1'
description: 'The critical S.M.A.R.T status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}'
value: '5'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
value: '6'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
value: '10'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}'
value: '5'
description: 'The critical status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}'
value: '6'
description: 'The disaster status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}'
value: '4'
description: 'The warning status of health for the trigger expression.'
- macro: '{$DELL.SNMP.IFCONTROL}'
value: '1'
description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}'
value: '5'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
value: '6'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
value: '3'
description: 'The OK status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for the SNMP agent availability trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
value: '3'
description: 'The critical status of the virtual disk for the trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
value: '4'
description: 'The warning status of the virtual disk for the trigger expression.'
dashboards:
- uuid: 4b25be13fc3d4fd9bb73621f4e00c64e
name: Overview
pages:
- name: Overview
display_period: '30'
widgets:
- type: item
name: 'System health'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'System Health'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.status[globalSystemStatus]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'Serial number'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'Serial number'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'HW model'
x: '36'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'HW model'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.hw.model[systemModelName]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: Firmware
x: '36'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: Firmware
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- name: Discoveries
display_period: '30'
widgets:
- type: honeycomb
name: 'Interface link'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'NIC*Link status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAA
- type: STRING
name: thresholds.0.color
value: 069C56
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: FF681E
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: 'Temperature sensors'
'y': '4'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Probe*Value'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAB
- type: INTEGER
name: secondary_label_decimal_places
value: '0'
- type: honeycomb
name: 'Physical disks'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Physical disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAC
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
- type: honeycomb
name: 'Power supplies'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Voltage probe*Voltage'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAE
- type: honeycomb
name: 'Virtual disks'
x: '36'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Virtual disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAD
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: Fans
x: '36'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Fan*Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAF
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
valuemaps:
- uuid: 3764082c250540f0b2827412a751f842
name: 'IDRAC-MIB-SMIv2::batteryState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Ready
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- value: '5'
newvalue: Missing
- value: '6'
newvalue: Charging
- value: '7'
newvalue: 'Below threshold'
- uuid: ef50d21a037545078e00102504b9b79d
name: 'IDRAC-MIB-SMIv2::BooleanType'
mappings:
- value: '0'
newvalue: ok
- value: '1'
newvalue: failed
- uuid: d731845914484868bbcb3c3e5b9d7707
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
mappings:
- value: '0'
newvalue: unknown
- value: '1'
newvalue: connected
- value: '2'
newvalue: disconnected
- value: '3'
newvalue: driverBad
- value: '4'
newvalue: driverDisabled
- value: '10'
newvalue: hardwareInitalizing
- value: '11'
newvalue: hardwareResetting
- value: '12'
newvalue: hardwareClosing
- value: '13'
newvalue: hardwareNotReady
- uuid: faa7d65868044cb08c2681db9615ef83
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: c0b777b910e94d338ebfaacc94ca5c54
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: 596722d9a0b84c499908e460ba634a87
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: HDD
- value: '3'
newvalue: SSD
- uuid: 4b8e905e42a94f8ebb9a9a4b2648ed84
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
mappings:
- value: '1'
newvalue: internalError
- value: '2'
newvalue: thermalTrip
- value: '32'
newvalue: configurationError
- value: '128'
newvalue: processorPresent
- value: '256'
newvalue: processorDisabled
- value: '512'
newvalue: terminatorPresent
- value: '1024'
newvalue: processorThrottled
- uuid: bd55f661ad24498a8876816ef9e70506
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCriticalUpper
- value: '5'
newvalue: criticalUpper
- value: '6'
newvalue: nonRecoverableUpper
- value: '7'
newvalue: nonCriticalLower
- value: '8'
newvalue: criticalLower
- value: '9'
newvalue: nonRecoverableLower
- value: '10'
newvalue: failed
- uuid: 487f601e3f35437e800314865895b69b
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
mappings:
- value: '1'
newvalue: Other
- value: '2'
newvalue: RAID-0
- value: '3'
newvalue: RAID-1
- value: '4'
newvalue: RAID-5
- value: '5'
newvalue: RAID-6
- value: '6'
newvalue: RAID-10
- value: '7'
newvalue: RAID-50
- value: '8'
newvalue: RAID-60
- value: '9'
newvalue: 'Concatenated RAID 1'
- value: '10'
newvalue: 'Concatenated RAID 5'
- uuid: a02a3f0c0fb24a52887f3feec42ae42a
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
mappings:
- value: '1'
newvalue: 'Not applicable'
- value: '2'
newvalue: Reconstructing
- value: '3'
newvalue: Resynching
- value: '4'
newvalue: Initializing
- value: '5'
newvalue: 'Background init'
- uuid: e2b543acfe9045ae8950075c1174b836
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
mappings:
- value: '1'
newvalue: 'No Read Ahead'
- value: '2'
newvalue: 'Read Ahead'
- value: '3'
newvalue: 'Adaptive Read Ahead'
- uuid: 348ab665927b43e2b7e53eac8ab95820
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Online
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- uuid: 3bfaa8f277a549f7ae8a1bf0dc49e64f
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
mappings:
- value: '1'
newvalue: 'Write Through'
- value: '2'
newvalue: 'Write Back'
- value: '3'
newvalue: 'Force Write Back'
- uuid: 8124caf5004c4dd8985810ac9e6374b6
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 03411617acad4aeb8ddcb5e873ae1b73
expression: '(last(/DELL PowerEdge R720 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R720 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R720 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R720 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)'
name: 'Dell R720: Host has been restarted'
event_name: 'Dell R720: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
graphs:
- uuid: 36ecb02a52704e5987c5736fd650722d
name: 'Dell R720: Uptime'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
- sortorder: '1'
color: F63100
item:
host: 'DELL PowerEdge R720 by SNMP'
key: 'dell.server.net.uptime[snmpEngineTime]'