zabbix_export: version: '7.0' template_groups: - uuid: e960332b3f6c46a1956486d4f3f99fce name: 'Templates/Server hardware' templates: - uuid: fe5b8448661f41b9a6d948fccd7f9045 template: 'DELL PowerEdge R720 by SNMP' name: 'DELL PowerEdge R720 by SNMP' description: | Template for DELL PowerEdge R720 servers with iDRAC version 7 and later. MIBs used: HOST-RESOURCES-MIB IDRAC-MIB-SMIv2 SNMPv2-MIB You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates Generated by official Zabbix template tool "Templator" vendor: name: Zabbix version: 7.0-5 groups: - name: 'Templates/Server hardware' items: - uuid: 93c5649909334a61ba0414fe7e0063a3 name: 'SNMP walk RAID controllers table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]' key: dell.server.array.controller.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.' tags: - tag: component value: raw - uuid: 34a1321bf79841a2a600b11e12d3cef1 name: 'SNMP walk Battery table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]' key: dell.server.battery.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.' tags: - tag: component value: raw - uuid: 5e8cd7ff8b5b4ac796147f72087ea925 name: 'BIOS version' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]' key: dell.server.bios.version value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the version name of the system BIOS. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: cd86d6203a874b27be4ed91578928dcf name: 'System contact details' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.4.0]' key: 'dell.server.contact[sysContact]' delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB Name and contact information of the contact person for the node. If not provided, the value is a zero-length string. inventory_link: CONTACT preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: 4f2fabba628e45ab9dc8627e32e9a35a name: 'SNMP walk Processor device tables' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]' key: dell.server.cpu.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.' tags: - tag: component value: raw - uuid: d5c65ffddfff45319a3f6ba856b73f6b name: 'System description' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.1.0]' key: 'dell.server.descr[sysDescr]' delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: 9773c82f46a6485992049843de57de3e name: 'SNMP walk Physical disk table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]' key: dell.server.disk.physical.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.' tags: - tag: component value: raw - uuid: bf3b1c74945f40549ddd4688250846e1 name: 'SNMP walk Virtual disk table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]' key: dell.server.disk.virtual.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.' tags: - tag: component value: raw - uuid: 5e06ce9f690c4671bf0fbf38aa6e3b89 name: 'SNMP walk Cooling device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]' key: dell.server.fan.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.' tags: - tag: component value: raw - uuid: 00928da92ab7499aba169837b2fffc83 name: 'Firmware version' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]' key: 'dell.server.hw.firmware[racFirmwareVersion]' delay: 1h value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the firmware version of a remote access card. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 46c22d9eca174756903b8c26ec69c792 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0' name: 'Dell R720: Firmware has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: INFO description: 'Firmware version has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 34fd8f0eaae041828cd1743ef55c16f9 name: 'Hardware model name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]' key: 'dell.server.hw.model[systemModelName]' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the model name of the system. inventory_link: MODEL preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: f5753d89e11f43fba46959b60601d45c name: 'Hardware serial number' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]' key: 'dell.server.hw.serialnumber[systemServiceTag]' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the service tag of the system. inventory_link: SERIALNO_A preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: 1e3f0933fae74fc29c13177fe2cf6903 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0' name: 'Dell R720: Device has been replaced' event_name: 'Dell R720: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 3240487059234b49bb822113c1964693 name: 'Uptime (hardware)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]' key: 'dell.server.hw.uptime[systemPowerUpTime]' trends: '0' units: uptime description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the power-up time of the system in seconds. tags: - tag: component value: system - uuid: ca9019fd89654c52889a12153150151d name: 'System location' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.6.0]' key: 'dell.server.location[sysLocation]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string. inventory_link: LOCATION preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: beac13b3dfa04b0a9edf1a01e559021e name: 'Memory, total size' type: CALCULATED key: dell.server.memory.size.total units: B params: 'sum(last_foreach(//dell.server.memory.size[*]))' description: 'Total memory amount on the device.' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: memory triggers: - uuid: deb6d163f8824e489d9e64674d648d80 expression: 'change(/DELL PowerEdge R720 by SNMP/dell.server.memory.size.total)>0' name: 'Dell R720: Memory amount has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: AVERAGE tags: - tag: scope value: availability - uuid: 84267fb8555d48398b661bce37be8a74 name: 'SNMP walk Memory device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]' key: dell.server.memory.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.' tags: - tag: component value: raw - uuid: 8b72816906274e1281929a318c44e8c6 name: 'System name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.5.0]' key: 'dell.server.name[sysName]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string. inventory_link: NAME preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: 12327b9851254d28b1db193fbca51f9a expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.name[sysName]))>0' name: 'Dell R720: System name has changed' event_name: 'Dell R720: System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'The name of the system has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 2d273acf4bb646d7a3ca9602d7b529af name: 'SNMP walk Network device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]' key: dell.server.net.if.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.' tags: - tag: component value: raw - uuid: 767944c5d9e0470580f813948d9dbe96 name: 'Uptime (network)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]' key: 'dell.server.net.uptime[snmpEngineTime]' trends: '0' units: uptime description: | MIB: SNMP-FRAMEWORK-MIB The number of seconds since the value of the snmpEngineBoots object last changed. tags: - tag: component value: system - uuid: 18c324fe6e714549bc337c2711795c40 name: 'System object ID' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.2.0]' key: 'dell.server.objectid[sysObjectID]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1). preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: a5b4a818eeb04e1fb072b3b8e76441f3 name: 'SNMP walk Power supply table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]' key: dell.server.psu.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.' tags: - tag: component value: raw - uuid: 6f407f3ff09f48179075f54eb26604db name: 'SNMP walk Temperature sensor table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]' key: dell.server.sensor.temp.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.' tags: - tag: component value: raw - uuid: 341699ea98c64951b1d94d89b5c81362 name: 'Overall system health status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]' key: 'dell.server.status[globalSystemStatus]' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: health - tag: component value: system triggers: - uuid: 7b6bbbaf7a6f4ba084e812fc98aee033 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}' name: 'Dell R720: System is in unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 51bd134f73234388b1c9522468b73883 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}' name: 'Dell R720: System status is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for errors.' tags: - tag: scope value: availability - uuid: e026d877c5e540b9ae06d44874e7ec5d expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}' name: 'Dell R720: System status is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for warnings.' dependencies: - name: 'Dell R720: System status is in critical state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}' tags: - tag: scope value: availability - uuid: c8d519bdde9a4c3b89976f7b0dab0696 name: 'Operating system' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]' key: 'dell.server.sw.os[systemOSName]' delay: 1h value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the name of the operating system that the host is running. inventory_link: OS preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 2e07d3f10a114360b4189e47cfd777f8 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.sw.os[systemOSName]))>0' name: 'Dell R720: Operating system description has changed' priority: INFO description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 8cb0cacb3ca144d2b917ea457ef3ba24 name: 'SNMP walk System battery table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]' key: dell.server.system.battery.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.' tags: - tag: component value: raw - uuid: 5f7dc7b0c23c40e4b8442ae1223d70d5 name: 'SNMP walk Voltage probe table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]' key: dell.server.voltage.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.' tags: - tag: component value: raw - uuid: 65097a06ef764129bcb0cb7fdd1f0ec8 name: 'SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback delay: '0' value_type: LOG trends: '0' description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: component value: network - uuid: 943b9c35a40c4ca7811212b20b27677d name: 'SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' description: | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown valuemap: name: zabbix.host.available tags: - tag: component value: health - tag: component value: system triggers: - uuid: f0b0662e38cd4aa6893dc3b5f89b9c81 expression: 'max(/DELL PowerEdge R720 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0' name: 'Dell R720: No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' tags: - tag: scope value: availability discovery_rules: - uuid: b61fe289fe88450db55f03c632e8a26f name: 'Array controller discovery' type: DEPENDENT key: array.discovery delay: '0' description: 'Array controller discovery.' item_prototypes: - uuid: 0f565dd530fa4a0bb93b642c8ee19b0f name: 'Controller [{#CNTLR_NAME}]: Model' type: DEPENDENT key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The controller's name as represented in Storage Management. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.array.controller.walk tags: - tag: component value: diskarray - tag: component value: storage - uuid: 69ed8def6e2c4025abcc565217064600 name: 'Controller [{#CNTLR_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.array.controller.walk tags: - tag: component value: diskarray - tag: component value: storage trigger_prototypes: - uuid: c9298bbaac134cc39e268d0b94051fcc expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' name: 'Dell R720: Controller [{#CNTLR_NAME}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' dependencies: - name: 'Dell R720: Controller [{#CNTLR_NAME}]: Unrecoverable state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability - uuid: 69ff155a6ecd4b709a1579641a711283 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' name: 'Dell R720: Controller [{#CNTLR_NAME}]: Unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: ddb5bca1ce3b45fa8da9197d4ac0f758 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}' name: 'Dell R720: Controller [{#CNTLR_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R720: Controller [{#CNTLR_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' - name: 'Dell R720: Controller [{#CNTLR_NAME}]: Unrecoverable state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability master_item: key: dell.server.array.controller.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38 - '0' - '{#CNTLR_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: ed881938a95c4be2b9c7f0d548696f27 name: 'Battery discovery' type: DEPENDENT key: battery.discovery delay: '0' description: 'Battery discovery.' item_prototypes: - uuid: 9444982ba8cf4c70a03a780fab18a36a name: 'Battery [{#BATTERY_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold. valuemap: name: 'IDRAC-MIB-SMIv2::batteryState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.battery.walk tags: - tag: component value: battery - tag: component value: diskarray trigger_prototypes: - uuid: 7c3cb436445949b5a28368cf4ce00fdc expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' name: 'Dell R720: Battery [{#BATTERY_NAME}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 8cd73ebf8055426883d8301ceeca51de expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' name: 'Dell R720: Battery [{#BATTERY_NAME}]: Not in optimal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the device for faults.' dependencies: - name: 'Dell R720: Battery [{#BATTERY_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' - name: 'Dell R720: Battery [{#BATTERY_NAME}]: Warning state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' tags: - tag: scope value: availability - uuid: 893e3d8d04e841058eafa43752546f1c expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' name: 'Dell R720: Battery [{#BATTERY_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R720: Battery [{#BATTERY_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' tags: - tag: scope value: availability master_item: key: dell.server.battery.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#BATTERY_NUM}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 - '0' - '{#BATTERY_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 6df0976045b942b8986b8c3a46c2fde4 name: 'CPU status discovery' type: DEPENDENT key: cpu.discovery delay: '0' description: 'CPU status discovery.' item_prototypes: - uuid: 668835ea1b0a4146a6296d298a9f1607 name: 'CPU [{#CPU_FQDD}]: State' type: DEPENDENT key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]' delay: '0' description: 'This attribute defines the reading of the processor device status probe.' valuemap: name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.cpu.walk tags: - tag: component value: cpu trigger_prototypes: - uuid: 1f919ce7df874574b764d1c3f17ed693 expression: 'bitand(last(/DELL PowerEdge R720 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0' name: 'Dell R720: CPU [{#CPU_FQDD}]: Reading error' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 CPU probe reading flag is not `processorPresent`. tags: - tag: scope value: availability - uuid: 201313c89ba245a794e5e76778c0dfa4 name: 'CPU [{#CPU_FQDD}]: Status' type: DEPENDENT key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]' delay: '0' description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.cpu.walk tags: - tag: component value: cpu trigger_prototypes: - uuid: 54f006add0c7435b8cabaa361d8eb27e expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3' name: 'Dell R720: CPU [{#CPU_FQDD}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 CPU status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.cpu.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#CPU_FQDD}' - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: c0c2f9b115f04ebe8b709032f8c97669 name: 'Fan discovery' type: DEPENDENT key: fan.discovery delay: '0' filter: conditions: - macro: '{#TYPE}' value: '3' formulaid: A description: 'Fan discovery.' item_prototypes: - uuid: fdd01d80c11e41e3aa1c8975b4f2b926 name: 'Fan [{#FAN_DESCR}]: Speed' type: DEPENDENT key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]' delay: '0' units: rpm description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`. When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device. When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}' - '0' master_item: key: dell.server.fan.walk tags: - tag: component value: fan - uuid: 028a4cd49fd04e92aac769f4e38a40c9 name: 'Fan [{#FAN_DESCR}]: Status' type: DEPENDENT key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the cooling device. valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.fan.walk tags: - tag: component value: fan trigger_prototypes: - uuid: 20e8c5ad48a44748a5223aa1f2c391dc expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' name: 'Dell R720: Fan [{#FAN_DESCR}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit.' tags: - tag: scope value: availability - uuid: 791e1a7e913c467fb93209e75e33e7ca expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R720: Fan [{#FAN_DESCR}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the fan unit.' dependencies: - name: 'Dell R720: Fan [{#FAN_DESCR}]: Critical state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability graph_prototypes: - uuid: 32ac4de62079442c839ac548abd71e52 name: 'Dell R720: Fan [{#FAN_DESCR}]: Speed' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]' master_item: key: dell.server.fan.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.5 - '0' - '{#FAN_DESCR}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.8 - '0' - '{#TYPE}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.7 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: c5603b825445457c8b39662df9fd7db8 name: 'Memory discovery' type: DEPENDENT key: memory.discovery delay: '0' description: 'Memory discovery.' item_prototypes: - uuid: 4c857762cecb45fe8bb545b5cc786d9c name: 'Memory [{#SNMPVALUE}]: Size' type: DEPENDENT key: 'dell.server.memory.size[{#SNMPVALUE}]' delay: '0' units: B description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - type: MULTIPLIER parameters: - '1024' master_item: key: dell.server.memory.walk tags: - tag: component value: memory - uuid: c692910b52774a33aabaff78e46cc855 name: 'Memory [{#SNMPVALUE}]: Status' type: DEPENDENT key: 'dell.server.memory.status[{#SNMPVALUE}]' delay: '0' description: 'This attribute defines the status of the memory device.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.memory.walk tags: - tag: component value: memory trigger_prototypes: - uuid: a2ba71923e31415ead86dc46fd7e665e expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3' name: 'Dell R720: Memory [{#SNMPVALUE}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 Memory status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.memory.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 669b97ebc2464988857a2496af5652a0 name: 'Network interface discovery' type: DEPENDENT key: net.if.discovery delay: '0' description: 'Discovery of network interfaces.' item_prototypes: - uuid: e6728405f5c64aec8822190e868625d3 name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status' type: DEPENDENT key: 'dell.server.net.if.link[{#NIC_FQDD}]' delay: '0' description: 'This attribute defines the connection status of the network device.' valuemap: name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.net.if.walk tags: - tag: component value: network trigger_prototypes: - uuid: a5455d074ae94d7daa4eb11d345e33fb expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0' name: 'Dell R720: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | This trigger expression works as follows: 1. It can be triggered if the operations status is Down. 2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down. 3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.) manual_close: 'YES' tags: - tag: scope value: availability - uuid: 396dee5189a14314a861a04d9a0dcacc name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status' type: DEPENDENT key: 'dell.server.net.if.status[{#NIC_FQDD}]' delay: '0' description: 'This attribute defines the status of the network device.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.net.if.walk tags: - tag: component value: network trigger_prototypes: - uuid: a56df48040fd4ffcb6401cc7a407d303 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3' name: 'Dell R720: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 Network interface status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.net.if.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#NIC_FQDD}' - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1 - '0' - '{#NIC_MAC}' - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1 - '2' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: ed21036b0df047f5924df6ed4fd53b62 name: 'Physical disk discovery' type: DEPENDENT key: physicaldisk.discovery delay: '0' description: 'Physical disk discovery.' item_prototypes: - uuid: 6830d155acf647fd990822137efa9d02 name: 'Physical disk [{#DISK_NAME}]: Media type' type: DEPENDENT key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Drive (SSD). valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 3cae98ed317a43e7920d4ae9106fe9cd name: 'Physical disk [{#DISK_NAME}]: Model name' type: DEPENDENT key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The model number of the physical disk. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 27f4105ce0c24d9f8509f71b59ce8714 name: 'Physical disk [{#DISK_NAME}]: Serial number' type: DEPENDENT key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The physical disk's unique identification number from the manufacturer. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 74b1394597ce4036b9eef76db92a9ac7 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0' name: 'Dell R720: Physical disk [{#DISK_NAME}] has been replaced' event_name: 'Dell R720: [{#DISK_NAME}] has been replaced (new serial number received)' priority: INFO description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 20d406f393fc4a6b9963569d24a02106 name: 'Physical disk [{#DISK_NAME}]: Size' type: DEPENDENT key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]' delay: '0' trends: '0' units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the physical disk in megabytes. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: aa58b1d10ae8498a9f6ca736e083ec91 name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status' type: DEPENDENT key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 Indicates whether the physical disk has received a predictive failure alert. valuemap: name: 'IDRAC-MIB-SMIv2::BooleanType' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 85205e77583b4d82b408fd1bedb6e680 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}' name: 'Dell R720: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Disk probably requires replacement.' dependencies: - name: 'Dell R720: Physical disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability - uuid: 551bee86234a4c99a6c7c5ac7db89f37 name: 'Physical disk [{#DISK_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 899cfe68ef4f4a8abf841c7efb7448a7 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' name: 'Dell R720: Physical disk [{#DISK_NAME}]: Failed state' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check physical disk for warnings or errors.' tags: - tag: scope value: availability - uuid: aaeaa0c4d26d4f8d878517efff99c624 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}' name: 'Dell R720: Physical disk [{#DISK_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check physical disk for warnings or errors.' dependencies: - name: 'Dell R720: Physical disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability graph_prototypes: - uuid: 3b54483c46bb4038a3fb60070b1ab41b name: 'Dell R720: Physical disk [{#DISK_NAME}]: Size' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]' master_item: key: dell.server.disk.physical.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 - '0' - '{#DISK_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 166c453303e843bbadc62963b725da95 name: 'PSU discovery' type: DEPENDENT key: psu.discovery delay: '0' description: 'PSU discovery.' item_prototypes: - uuid: 43fe09a202994622bbef420c9b018d49 name: 'Power supply [{#PSU_DESCR}]: State' type: DEPENDENT key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the status of the power supply. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.psu.walk tags: - tag: component value: psu trigger_prototypes: - uuid: c3141535717d439fa74ffe068b0c61d5 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' name: 'Dell R720: Power supply [{#PSU_DESCR}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors.' tags: - tag: scope value: availability - uuid: 9b0d4e804b0c4918a7c3660f8772bc88 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}' name: 'Dell R720: Power supply [{#PSU_DESCR}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the power supply unit for errors.' dependencies: - name: 'Dell R720: Power supply [{#PSU_DESCR}]: Critical state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' tags: - tag: scope value: availability master_item: key: dell.server.psu.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 - '0' - '{#PSU_DESCR}' - 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 28b27d2152814dda9a9fef602ec78b38 name: 'System battery discovery' type: DEPENDENT key: system.battery.discovery delay: '0' description: 'System battery discovery.' item_prototypes: - uuid: 89887fe6674e42ac985018f1da7c86e0 name: 'System battery [{#SNMPVALUE}]: Status' type: DEPENDENT key: 'dell.server.system.battery[{#SNMPVALUE}]' delay: '0' description: 'This attribute defines the status of the battery.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.system.battery.walk tags: - tag: component value: battery trigger_prototypes: - uuid: d61b5c42fbe9451fb02e66cb65682a3d expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3' name: 'Dell R720: System battery [{#SNMPVALUE}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 System battery status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.system.battery.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 8e29bd2cab71430b8306394b6f629ac2 name: 'Temperature discovery' type: DEPENDENT key: temp.discovery delay: '0' description: 'Temperature sensor discovery.' item_prototypes: - uuid: 8933cb6596154baca790294c37d0a3b9 name: 'Probe [{#SENSOR_LOCALE}]: Status' type: DEPENDENT key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]' delay: '0' value_type: FLOAT trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the temperature probe. Possible values: other(1), -- probe status is not one of the following: unknown(2), -- probe status is unknown (not known or monitored) ok(3), -- probe is reporting a value within the thresholds nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold criticalUpper(5), -- probe has crossed the upper critical threshold nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold nonCriticalLower(7), -- probe has crossed the lower noncritical threshold criticalLower(8), -- probe has crossed the lower critical threshold nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold failed(10) -- probe is not functional valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.sensor.temp.walk tags: - tag: component value: temperature trigger_prototypes: - uuid: 6c9f6edf352f458a96ab3e388307afd6 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Critical status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: a897d28f37914cad92faaa3ffb218463 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}' name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Not in optimal status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the device for faults.' manual_close: 'YES' dependencies: - name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Critical status' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' - name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Warning status' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' tags: - tag: scope value: notice - uuid: 44b9519b16e441028e7af08ae1ec4942 expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Warning status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Critical status' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R720 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' tags: - tag: scope value: availability - uuid: 9c03b7da06874b69a43943de63912d82 name: 'Probe [{#SENSOR_LOCALE}]: Value' type: DEPENDENT key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]' delay: '0' value_type: FLOAT units: °C description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`. When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade. When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '0.1' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.sensor.temp.walk tags: - tag: component value: temperature graph_prototypes: - uuid: 857150f6f2ff4fec9fb80e3235adb830 name: 'Dell R720: Probe [{#SENSOR_LOCALE}]: Value' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]' master_item: key: dell.server.sensor.temp.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 - '0' - '{#SENSOR_LOCALE}' - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 4332291ca425477387bed6abccaaefd3 name: 'Virtual disk discovery' type: DEPENDENT key: virtualdisk.discovery delay: '0' description: 'Virtual disk discovery.' item_prototypes: - uuid: 6f63f8bbeba44c3a85a874f6e2796b26 name: 'Virtual disk [{#DISK_NAME}]: Layout type' type: DEPENDENT key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5 valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 9bcd5c8774d64293a3c03135df0026bf name: 'Virtual disk [{#DISK_NAME}]: Read policy' type: DEPENDENT key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: f52835c258ea4b2ab16ab91fa14f2cd9 name: 'Virtual disk [{#DISK_NAME}]: Size' type: DEPENDENT key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]' delay: '0' trends: '0' units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the virtual disk in megabytes. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 100faa8a115f4f34a61938fc9fe2b056 name: 'Virtual disk [{#DISK_NAME}]: Operational state' type: DEPENDENT key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 3m master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 9f49cd360dc849d19abe10cd5cf94a10 name: 'Virtual disk [{#DISK_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost. 4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk trigger_prototypes: - uuid: 0bd27a473d694b9c8ddb59fe2711608a expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' name: 'Dell R720: Virtual disk [{#DISK_NAME}]: Failed state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the virtual disk for warnings or errors.' tags: - tag: scope value: availability - uuid: 7ca47e8ba4a549b2a799d4e78adf5add expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}' name: 'Dell R720: Virtual disk [{#DISK_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the virtual disk for warnings or errors.' dependencies: - name: 'Dell R720: Virtual disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability - uuid: d599f3c67807443b82c9ec83af325142 name: 'Virtual disk [{#DISK_NAME}]: Write policy' type: DEPENDENT key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk graph_prototypes: - uuid: 7f5fdaf45edf49f4bde8c86147949c50 name: 'Dell R720: Virtual disk [{#DISK_NAME}]: Size' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]' master_item: key: dell.server.disk.virtual.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 - '0' - '{#DISK_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 1aa767e3c91e427ebd508df8e49f89dd name: 'Voltage probe discovery' type: DEPENDENT key: voltage.discovery delay: '0' filter: evaltype: AND conditions: - macro: '{#VPROBE_NAME}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}' formulaid: A - macro: '{#VPROBE_NAME}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: B - macro: '{#VPROBE_TYPE}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}' formulaid: C - macro: '{#VPROBE_TYPE}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: D description: 'Voltage probe discovery.' item_prototypes: - uuid: 2b9a84f4a7fb429081a22394ba9ef81f name: 'Voltage probe [{#VPROBE_NAME}]: Status' type: DEPENDENT key: 'dell.server.voltage.status[{#VPROBE_NAME}]' delay: '0' description: 'This attribute defines the status of the voltage probe.' valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}' - '0' master_item: key: dell.server.voltage.walk tags: - tag: component value: voltage trigger_prototypes: - uuid: 68360a834efd4d0188a9d58d01b9429a expression: 'last(/DELL PowerEdge R720 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3' name: 'Dell R720: Voltage probe [{#VPROBE_NAME}]: Status is not OK' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device''s voltage.' tags: - tag: scope value: availability - uuid: 053c9f3e14cc438795b0a7911ab57854 name: 'Voltage probe [{#VPROBE_NAME}]: Voltage' type: DEPENDENT key: 'dell.server.voltage.value[{#VPROBE_NAME}]' delay: '0' value_type: FLOAT units: V description: 'This attribute defines the reading for a voltage probe.' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '0.001' master_item: key: dell.server.voltage.walk tags: - tag: component value: voltage graph_prototypes: - uuid: 441e248166f64944aec3abc9e296c980 name: 'Dell R720: Voltage probe [{#VPROBE_NAME}]: Voltage' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.voltage.value[{#VPROBE_NAME}]' master_item: key: dell.server.voltage.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#VPROBE_NAME}' - 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1 - '0' - '{#VPROBE_TYPE}' - 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: class value: hardware - tag: target value: dell - tag: target value: 'dell poweredge' macros: - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}' value: '^.*Voltage.*$' description: 'Sets the regex string of voltage probe names to allow in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'Sets the regex string of voltage probe names to ignore in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}' value: 18|16 description: 'Sets the regex string of voltage probe types to allow in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'Sets the regex string of voltage probe types to ignore in discovery.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' value: '3' description: 'The critical status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' value: '2' description: 'The OK status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' value: '5' description: 'The critical status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' value: '6' description: 'The disaster status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}' value: '1' description: 'The critical S.M.A.R.T status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}' value: '5' description: 'The critical status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' value: '6' description: 'The critical status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' value: '10' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}' value: '5' description: 'The critical status of health for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}' value: '6' description: 'The disaster status of health for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}' value: '4' description: 'The warning status of health for the trigger expression.' - macro: '{$DELL.SNMP.IFCONTROL}' value: '1' description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".' - macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}' value: '5' description: 'The critical value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' value: '6' description: 'The critical value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}' value: '3' description: 'The OK status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.TIMEOUT}' value: 5m description: 'The time interval for the SNMP agent availability trigger expression.' - macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' value: '3' description: 'The critical status of the virtual disk for the trigger expression.' - macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}' value: '4' description: 'The warning status of the virtual disk for the trigger expression.' dashboards: - uuid: 4b25be13fc3d4fd9bb73621f4e00c64e name: Overview pages: - name: Overview display_period: '30' widgets: - type: item name: 'System health' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'System Health' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.status[globalSystemStatus]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: 'Serial number' 'y': '4' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'Serial number' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.hw.serialnumber[systemServiceTag]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: 'HW model' x: '36' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'HW model' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.hw.model[systemModelName]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: Firmware x: '36' 'y': '4' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: Firmware - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.hw.firmware[racFirmwareVersion]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - name: Discoveries display_period: '30' widgets: - type: honeycomb name: 'Interface link' width: '72' height: '4' fields: - type: STRING name: items.0 value: 'NIC*Link status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size value: '15' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAA - type: STRING name: thresholds.0.color value: 069C56 - type: STRING name: thresholds.0.threshold value: '1' - type: STRING name: thresholds.1.color value: FF681E - type: STRING name: thresholds.1.threshold value: '2' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '3' - type: honeycomb name: 'Temperature sensors' 'y': '4' width: '72' height: '4' fields: - type: STRING name: items.0 value: 'Probe*Value' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAB - type: INTEGER name: secondary_label_decimal_places value: '0' - type: honeycomb name: 'Physical disks' 'y': '8' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Physical disk*: Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size value: '15' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAC - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '0' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '3' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '4' - type: honeycomb name: 'Power supplies' 'y': '12' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Voltage probe*Voltage' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAE - type: honeycomb name: 'Virtual disks' x: '36' 'y': '8' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Virtual disk*: Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAD - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '1' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '2' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '3' - type: honeycomb name: Fans x: '36' 'y': '12' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Fan*Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAF - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '0' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '3' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '4' valuemaps: - uuid: 3764082c250540f0b2827412a751f842 name: 'IDRAC-MIB-SMIv2::batteryState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Ready - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - value: '5' newvalue: Missing - value: '6' newvalue: Charging - value: '7' newvalue: 'Below threshold' - uuid: ef50d21a037545078e00102504b9b79d name: 'IDRAC-MIB-SMIv2::BooleanType' mappings: - value: '0' newvalue: ok - value: '1' newvalue: failed - uuid: d731845914484868bbcb3c3e5b9d7707 name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum' mappings: - value: '0' newvalue: unknown - value: '1' newvalue: connected - value: '2' newvalue: disconnected - value: '3' newvalue: driverBad - value: '4' newvalue: driverDisabled - value: '10' newvalue: hardwareInitalizing - value: '11' newvalue: hardwareResetting - value: '12' newvalue: hardwareClosing - value: '13' newvalue: hardwareNotReady - uuid: faa7d65868044cb08c2681db9615ef83 name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: c0b777b910e94d338ebfaacc94ca5c54 name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: 596722d9a0b84c499908e460ba634a87 name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: HDD - value: '3' newvalue: SSD - uuid: 4b8e905e42a94f8ebb9a9a4b2648ed84 name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags' mappings: - value: '1' newvalue: internalError - value: '2' newvalue: thermalTrip - value: '32' newvalue: configurationError - value: '128' newvalue: processorPresent - value: '256' newvalue: processorDisabled - value: '512' newvalue: terminatorPresent - value: '1024' newvalue: processorThrottled - uuid: bd55f661ad24498a8876816ef9e70506 name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCriticalUpper - value: '5' newvalue: criticalUpper - value: '6' newvalue: nonRecoverableUpper - value: '7' newvalue: nonCriticalLower - value: '8' newvalue: criticalLower - value: '9' newvalue: nonRecoverableLower - value: '10' newvalue: failed - uuid: 487f601e3f35437e800314865895b69b name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' mappings: - value: '1' newvalue: Other - value: '2' newvalue: RAID-0 - value: '3' newvalue: RAID-1 - value: '4' newvalue: RAID-5 - value: '5' newvalue: RAID-6 - value: '6' newvalue: RAID-10 - value: '7' newvalue: RAID-50 - value: '8' newvalue: RAID-60 - value: '9' newvalue: 'Concatenated RAID 1' - value: '10' newvalue: 'Concatenated RAID 5' - uuid: a02a3f0c0fb24a52887f3feec42ae42a name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' mappings: - value: '1' newvalue: 'Not applicable' - value: '2' newvalue: Reconstructing - value: '3' newvalue: Resynching - value: '4' newvalue: Initializing - value: '5' newvalue: 'Background init' - uuid: e2b543acfe9045ae8950075c1174b836 name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' mappings: - value: '1' newvalue: 'No Read Ahead' - value: '2' newvalue: 'Read Ahead' - value: '3' newvalue: 'Adaptive Read Ahead' - uuid: 348ab665927b43e2b7e53eac8ab95820 name: 'IDRAC-MIB-SMIv2::virtualDiskState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Online - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - uuid: 3bfaa8f277a549f7ae8a1bf0dc49e64f name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' mappings: - value: '1' newvalue: 'Write Through' - value: '2' newvalue: 'Write Back' - value: '3' newvalue: 'Force Write Back' - uuid: 8124caf5004c4dd8985810ac9e6374b6 name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown triggers: - uuid: 03411617acad4aeb8ddcb5e873ae1b73 expression: '(last(/DELL PowerEdge R720 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R720 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R720 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R720 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)' name: 'Dell R720: Host has been restarted' event_name: 'Dell R720: {HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes.' manual_close: 'YES' tags: - tag: scope value: notice graphs: - uuid: 36ecb02a52704e5987c5736fd650722d name: 'Dell R720: Uptime' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.hw.uptime[systemPowerUpTime]' - sortorder: '1' color: F63100 item: host: 'DELL PowerEdge R720 by SNMP' key: 'dell.server.net.uptime[snmpEngineTime]'