zabbix_export:
|
|
version: '7.0'
|
|
template_groups:
|
|
- uuid: e960332b3f6c46a1956486d4f3f99fce
|
|
name: 'Templates/Server hardware'
|
|
templates:
|
|
- uuid: cb66d34564e44b3893442fc74cf6e951
|
|
template: 'Cisco UCS by SNMP'
|
|
name: 'Cisco UCS by SNMP'
|
|
description: |
|
|
Template Server Cisco UCS
|
|
|
|
MIBs used:
|
|
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
|
|
HOST-RESOURCES-MIB
|
|
SNMPv2-MIB
|
|
CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
|
|
CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
|
|
CISCO-UNIFIED-COMPUTING-STORAGE-MIB
|
|
|
|
Generated by official Zabbix template tool "Templator"
|
|
vendor:
|
|
name: Zabbix
|
|
version: 7.0-2
|
|
groups:
|
|
- name: 'Templates/Server hardware'
|
|
items:
|
|
- uuid: 250be2514e9246e08058a403bf674cf6
|
|
name: 'ICMP ping'
|
|
type: SIMPLE
|
|
key: icmpping
|
|
description: |
|
|
The host accessibility by ICMP ping.
|
|
|
|
0 - ICMP ping fails;
|
|
1 - ICMP ping successful.
|
|
valuemap:
|
|
name: 'Service state'
|
|
tags:
|
|
- tag: component
|
|
value: health
|
|
- tag: component
|
|
value: network
|
|
triggers:
|
|
- uuid: 301541972752471e86046ce494a2febb
|
|
expression: 'max(/Cisco UCS by SNMP/icmpping,#3)=0'
|
|
name: 'Cisco UCS: Unavailable by ICMP ping'
|
|
priority: HIGH
|
|
description: 'Last three attempts returned timeout. Please check device connectivity.'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- uuid: c7eaba8c2b7d4b4aa14081957252e33e
|
|
name: 'ICMP loss'
|
|
type: SIMPLE
|
|
key: icmppingloss
|
|
value_type: FLOAT
|
|
units: '%'
|
|
description: 'The percentage of lost packets.'
|
|
tags:
|
|
- tag: component
|
|
value: health
|
|
- tag: component
|
|
value: network
|
|
triggers:
|
|
- uuid: e051db53cf32406bb0d5ff9cc8d5ce7b
|
|
expression: 'min(/Cisco UCS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco UCS by SNMP/icmppingloss,5m)<100'
|
|
name: 'Cisco UCS: High ICMP ping loss'
|
|
opdata: 'Loss: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'ICMP packets loss detected.'
|
|
dependencies:
|
|
- name: 'Cisco UCS: Unavailable by ICMP ping'
|
|
expression: 'max(/Cisco UCS by SNMP/icmpping,#3)=0'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 88b4a6cc507748e19f08d0ffc9a15368
|
|
name: 'ICMP response time'
|
|
type: SIMPLE
|
|
key: icmppingsec
|
|
value_type: FLOAT
|
|
units: s
|
|
description: 'The ICMP ping response time (in seconds).'
|
|
tags:
|
|
- tag: component
|
|
value: health
|
|
- tag: component
|
|
value: network
|
|
triggers:
|
|
- uuid: a11942dac3504b64977c2de3e575d2eb
|
|
expression: 'avg(/Cisco UCS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
|
|
name: 'Cisco UCS: High ICMP ping response time'
|
|
opdata: 'Value: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Average ICMP response time is too high.'
|
|
dependencies:
|
|
- name: 'Cisco UCS: High ICMP ping loss'
|
|
expression: 'min(/Cisco UCS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco UCS by SNMP/icmppingloss,5m)<100'
|
|
- name: 'Cisco UCS: Unavailable by ICMP ping'
|
|
expression: 'max(/Cisco UCS by SNMP/icmpping,#3)=0'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 00b0172971e34784836d03e76b3480bd
|
|
name: 'SNMP traps (fallback)'
|
|
type: SNMP_TRAP
|
|
key: snmptrap.fallback
|
|
delay: '0'
|
|
value_type: LOG
|
|
trends: '0'
|
|
description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
|
|
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
|
|
tags:
|
|
- tag: component
|
|
value: network
|
|
- uuid: 50df0ad347d94cffb871256c6340af11
|
|
name: 'System contact details'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
|
|
key: 'system.contact[sysContact.0]'
|
|
delay: 15m
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
|
|
inventory_link: CONTACT
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 12h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 235302070dc54f148b92027967a6ff2f
|
|
name: 'System description'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
|
|
key: 'system.descr[sysDescr.0]'
|
|
delay: 15m
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
A textual description of the entity. This value should
|
|
include the full name and version identification of the system's hardware type, software operating-system, and
|
|
networking software.
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 12h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: a6d61b21f9f044a6912759e02787cb3f
|
|
name: 'Uptime (hardware)'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]'
|
|
key: 'system.hw.uptime[hrSystemUptime.0]'
|
|
delay: 30s
|
|
trends: '0'
|
|
units: uptime
|
|
description: |
|
|
MIB: HOST-RESOURCES-MIB
|
|
The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
|
|
preprocessing:
|
|
- type: CHECK_NOT_SUPPORTED
|
|
parameters:
|
|
- '-1'
|
|
error_handler: CUSTOM_VALUE
|
|
error_handler_params: '0'
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '0.01'
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 7ba9b86064ad432a9e6d1922ca29edda
|
|
name: 'System location'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
|
|
key: 'system.location[sysLocation.0]'
|
|
delay: 15m
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
Physical location of the node (e.g., `equipment room`, `3rd floor`). If not provided, the value is a zero-length string.
|
|
inventory_link: LOCATION
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 12h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 4674d8adc39343f7b46d21cae2ec1310
|
|
name: 'System name'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
|
|
key: system.name
|
|
delay: 15m
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
|
|
inventory_link: NAME
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 12h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
triggers:
|
|
- uuid: 3544e4ac11b44d14a6161523081c470e
|
|
expression: 'last(/Cisco UCS by SNMP/system.name,#1)<>last(/Cisco UCS by SNMP/system.name,#2) and length(last(/Cisco UCS by SNMP/system.name))>0'
|
|
name: 'Cisco UCS: System name has changed'
|
|
event_name: 'Cisco UCS: System name has changed (new name: {ITEM.VALUE})'
|
|
priority: INFO
|
|
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
- tag: scope
|
|
value: security
|
|
- uuid: 1b0551aa2d184c8d923788b5d159ed7c
|
|
name: 'Uptime (network)'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.3.0]'
|
|
key: 'system.net.uptime[sysUpTime.0]'
|
|
delay: 30s
|
|
trends: '0'
|
|
units: uptime
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
Time (in hundredths of a second) since the network management portion of the system was last re-initialized.
|
|
preprocessing:
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '0.01'
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: 05fe3cb6d2004e7ea2d37742fc2549d3
|
|
name: 'System object ID'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
|
|
key: 'system.objectid[sysObjectID.0]'
|
|
delay: 15m
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: SNMPv2-MIB
|
|
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 12h
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: b80f6a30ad124a1ea863f2fdb868ba6f
|
|
name: 'SNMP agent availability'
|
|
type: INTERNAL
|
|
key: 'zabbix[host,snmp,available]'
|
|
description: |
|
|
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
|
|
Possible values:
|
|
0 - not available
|
|
1 - available
|
|
2 - unknown
|
|
valuemap:
|
|
name: zabbix.host.available
|
|
tags:
|
|
- tag: component
|
|
value: health
|
|
- tag: component
|
|
value: network
|
|
triggers:
|
|
- uuid: 3c487a6b20c746eca9a7efc6058a60d9
|
|
expression: 'max(/Cisco UCS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
|
|
name: 'Cisco UCS: No SNMP data collection'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
|
|
dependencies:
|
|
- name: 'Cisco UCS: Unavailable by ICMP ping'
|
|
expression: 'max(/Cisco UCS by SNMP/icmpping,#3)=0'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
discovery_rules:
|
|
- uuid: 5c6518a1df0b45c09f3a2f186c3d4e3b
|
|
name: 'Array Controller Cache Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#DISKARRAY_CACHE_LOCATION},1.3.6.1.4.1.9.9.719.1.45.11.1.2]'
|
|
key: array.cache.discovery
|
|
delay: 1h
|
|
description: 'Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.'
|
|
item_prototypes:
|
|
- uuid: 52055929503041018d8261f15231f346
|
|
name: '{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery status'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.11.1.9.{#SNMPINDEX}]'
|
|
key: 'system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}]'
|
|
trends: '0'
|
|
description: 'MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB'
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
|
|
tags:
|
|
- tag: component
|
|
value: array
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
trigger_prototypes:
|
|
- uuid: 0b09b93602c94821ae1126e4f9550436
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS}")=1'
|
|
name: 'Cisco UCS: {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the device for faults'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: d2af6de00e57412d8a2efcb20b1524a4
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}],#1,"ne","{$DISK_ARRAY_CACHE_BATTERY_OK_STATUS}")=1'
|
|
name: 'Cisco UCS: {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is not in optimal state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the device for faults'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!'
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS}")=1'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: b77a56dcaa1947dd8c74b5764c36c22a
|
|
name: 'Array Controller Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#DISKARRAY_LOCATION},1.3.6.1.4.1.9.9.719.1.45.1.1.2]'
|
|
key: array.discovery
|
|
delay: 1h
|
|
description: 'Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.'
|
|
item_prototypes:
|
|
- uuid: b0e1dd6aab454628bf46c0dba5293424
|
|
name: '{#DISKARRAY_LOCATION}: Disk array controller model'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.1.1.5.{#SNMPINDEX}]'
|
|
key: 'system.hw.diskarray.model[cucsStorageControllerModel.{#SNMPINDEX}]'
|
|
delay: 1d
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: 'MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB'
|
|
tags:
|
|
- tag: component
|
|
value: array
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: 262d45ac58734c0096de2b96d8294f4c
|
|
name: '{#DISKARRAY_LOCATION}: Disk array controller status'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.1.1.6.{#SNMPINDEX}]'
|
|
key: 'system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}]'
|
|
trends: '0'
|
|
description: 'MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB'
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
|
|
tags:
|
|
- tag: component
|
|
value: array
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
trigger_prototypes:
|
|
- uuid: 44ec209460fb4010a087e971427b2fde
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CRIT_STATUS:\"inoperable\"}")=1'
|
|
name: 'Cisco UCS: {#DISKARRAY_LOCATION}: Disk array controller is in critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'Please check the device for faults'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: b419e0d296614f4285645954f8a7a970
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_WARN_STATUS:\"degraded\"}")=1'
|
|
name: 'Cisco UCS: {#DISKARRAY_LOCATION}: Disk array controller is in warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the device for faults'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#DISKARRAY_LOCATION}: Disk array controller is in critical state'
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CRIT_STATUS:\"inoperable\"}")=1'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: a83202bb105d481c93464650272c14eb
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"ne","{$DISK_ARRAY_OK_STATUS:\"operable\"}")=1'
|
|
name: 'Cisco UCS: {#DISKARRAY_LOCATION}: Disk array controller is not in optimal state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the device for faults'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#DISKARRAY_LOCATION}: Disk array controller is in critical state'
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CRIT_STATUS:\"inoperable\"}")=1'
|
|
- name: 'Cisco UCS: {#DISKARRAY_LOCATION}: Disk array controller is in warning state'
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_WARN_STATUS:\"degraded\"}")=1'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 3c067096a2fc40c390a335e40bacc089
|
|
name: 'FAN Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#FAN_LOCATION},1.3.6.1.4.1.9.9.719.1.15.12.1.2]'
|
|
key: fan.discovery
|
|
delay: 1h
|
|
item_prototypes:
|
|
- uuid: f65860004eb74ab187d080782177370c
|
|
name: '{#FAN_LOCATION}: Fan status'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.15.12.1.9.{#SNMPINDEX}]'
|
|
key: 'sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
trends: '0'
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
|
|
Cisco UCS equipment:Fan:operState managed object property
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
|
|
tags:
|
|
- tag: component
|
|
value: fan
|
|
trigger_prototypes:
|
|
- uuid: 5135b24c775f448c8998cadea3042e5b
|
|
expression: 'count(/Cisco UCS by SNMP/sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"inoperable\"}")=1'
|
|
name: 'Cisco UCS: {#FAN_LOCATION}: Fan is in critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the fan unit'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 895df7f89587441fa61223d5b2e442a2
|
|
expression: 'count(/Cisco UCS by SNMP/sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"degraded\"}")=1'
|
|
name: 'Cisco UCS: {#FAN_LOCATION}: Fan is in warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the fan unit'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#FAN_LOCATION}: Fan is in critical state'
|
|
expression: 'count(/Cisco UCS by SNMP/sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"inoperable\"}")=1'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 93247d3808394f7195356ced554d0d55
|
|
name: 'Physical Disk Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#DISK_LOCATION},1.3.6.1.4.1.9.9.719.1.45.4.1.2]'
|
|
key: physicalDisk.discovery
|
|
delay: 1h
|
|
description: 'Scanning table of physical drive entries CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskTable.'
|
|
item_prototypes:
|
|
- uuid: 4dc3f8718af645998441c436263a1053
|
|
name: '{#DISK_LOCATION}: Physical disk media type'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.7.{#SNMPINDEX}]'
|
|
key: 'system.hw.physicaldisk.media_type[cucsStorageLocalDiskModel.{#SNMPINDEX}]'
|
|
delay: 1h
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
|
|
Cisco UCS storage:LocalDisk:model managed object property. Actually returns 'HDD' or 'SSD'
|
|
tags:
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: 6d45ac307cce40d481c556660dea3157
|
|
name: '{#DISK_LOCATION}: Physical disk model name'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.12.{#SNMPINDEX}]'
|
|
key: 'system.hw.physicaldisk.model[cucsStorageLocalDiskSerial.{#SNMPINDEX}]'
|
|
delay: 1h
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
|
|
Cisco UCS storage:LocalDisk:serial managed object property. Actually returns part number code
|
|
tags:
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: da12b7742c0343709ab4c1d97c0b0f4c
|
|
name: '{#DISK_LOCATION}: Disk size'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.13.{#SNMPINDEX}]'
|
|
key: 'system.hw.physicaldisk.size[cucsStorageLocalDiskSize.{#SNMPINDEX}]'
|
|
delay: 1h
|
|
trends: '0'
|
|
units: B
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
|
|
Cisco UCS storage:LocalDisk:size managed object property. In MB.
|
|
preprocessing:
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '1048576'
|
|
tags:
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: cb73c8de596549888d5f94b13619da3d
|
|
name: '{#DISK_LOCATION}: Physical disk status'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.18.{#SNMPINDEX}]'
|
|
key: 'system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
trends: '0'
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
|
|
Cisco UCS storage:LocalDisk:diskState managed object property.
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStoragePDriveStatus'
|
|
tags:
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
trigger_prototypes:
|
|
- uuid: 445919e1ec414fd888f8911abc65650b
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}],#1,"eq","{$DISK_CRIT_STATUS:\"bad\"}")=1 or count(/Cisco UCS by SNMP/system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}],#1,"eq","{$DISK_CRIT_STATUS:\"predictiveFailure\"}")=1'
|
|
name: 'Cisco UCS: {#DISK_LOCATION}: Physical disk error'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check physical disk for warnings or errors'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#DISK_LOCATION}: Physical disk failed'
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}],#1,"eq","{$DISK_FAIL_STATUS:\"failed\"}")=1'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 77ce5c74eefd4a9b818c11c8c1581cd8
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}],#1,"eq","{$DISK_FAIL_STATUS:\"failed\"}")=1'
|
|
name: 'Cisco UCS: {#DISK_LOCATION}: Physical disk failed'
|
|
opdata: 'Current status: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'Please check physical disk for warnings or errors'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: f8be95a8eb5a487c8c8f05d62e90f041
|
|
name: 'PSU Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#PSU_LOCATION},1.3.6.1.4.1.9.9.719.1.15.56.1.2]'
|
|
key: psu.discovery
|
|
delay: 1h
|
|
item_prototypes:
|
|
- uuid: 0e869e57db494940b630fc2b8f10c60b
|
|
name: '{#PSU_LOCATION}: Power supply status'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.15.56.1.7.{#SNMPINDEX}]'
|
|
key: 'sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
trends: '0'
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
|
|
Cisco UCS equipment:Psu:operState managed object property
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
|
|
tags:
|
|
- tag: component
|
|
value: power
|
|
trigger_prototypes:
|
|
- uuid: 480d51d19be74b6e95f702b31baa5666
|
|
expression: 'count(/Cisco UCS by SNMP/sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"inoperable\"}")=1'
|
|
name: 'Cisco UCS: {#PSU_LOCATION}: Power supply is in critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
description: 'Please check the power supply unit for errors'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 07fa90b5296b48d9b45cc6a76e72ceeb
|
|
expression: 'count(/Cisco UCS by SNMP/sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"degraded\"}")=1'
|
|
name: 'Cisco UCS: {#PSU_LOCATION}: Power supply is in warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the power supply unit for errors'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#PSU_LOCATION}: Power supply is in critical state'
|
|
expression: 'count(/Cisco UCS by SNMP/sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"inoperable\"}")=1'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 098a87f2e7094da9853bf2cb94677092
|
|
name: 'Temperature CPU Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#SENSOR_LOCATION},1.3.6.1.4.1.9.9.719.1.41.2.1.2]'
|
|
key: temp.cpu.discovery
|
|
delay: 1h
|
|
item_prototypes:
|
|
- uuid: b0a744fc4e524406ab87ccc4fbaae3b2
|
|
name: '{#SENSOR_LOCATION}: Temperature'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.41.2.1.10.{#SNMPINDEX}]'
|
|
key: 'sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
value_type: FLOAT
|
|
units: °C
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
|
|
Cisco UCS processor:EnvStats:temperature managed object property
|
|
tags:
|
|
- tag: component
|
|
value: temperature
|
|
trigger_prototypes:
|
|
- uuid: 35549eb00faf48ff8fdb7769b8a13895
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"CPU"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"CPU"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}: Temperature is above critical threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP_CRIT:"CPU"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: eaadcea2dc0d468d886654c3ec380390
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"CPU"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP_WARN:"CPU"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}: Temperature is above warning threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}: Temperature is above warning threshold: >{$TEMP_WARN:"CPU"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#SENSOR_LOCATION}: Temperature is above critical threshold'
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"CPU"}'
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"CPU"}-3'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: ccb9b9edd7ba4a62b33e34ebf3647825
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"CPU"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'min(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"CPU"}+3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}: Temperature is too low'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}: Temperature is too low: <{$TEMP_CRIT_LOW:"CPU"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 06216bba529b4fb2b1c52fb57d365c6a
|
|
name: 'Temperature Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#SENSOR_LOCATION},1.3.6.1.4.1.9.9.719.1.9.44.1.2]'
|
|
key: temp.discovery
|
|
delay: 1h
|
|
item_prototypes:
|
|
- uuid: 1287280a5c9449bd96f11ad3b6a92455
|
|
name: '{#SENSOR_LOCATION}.IOH: Temperature'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.44.1.13.{#SNMPINDEX}]'
|
|
key: 'sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
value_type: FLOAT
|
|
units: °C
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
|
|
Cisco UCS compute:RackUnitMbTempStats:ioh1Temp managed object property
|
|
tags:
|
|
- tag: component
|
|
value: temperature
|
|
trigger_prototypes:
|
|
- uuid: a43eb91c4ae044729f4312466fcbd5da
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Ambient"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: da5d63d3411a4d2299d50cc21beae1c4
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"Ambient"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.IOH: Temperature is above warning threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.IOH: Temperature is above warning threshold: >{$TEMP_WARN:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold'
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"}'
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Ambient"}-3'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: ce811e4247d5484caf4b095e829f162e
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'min(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"Ambient"}+3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.IOH: Temperature is too low'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.IOH: Temperature is too low: <{$TEMP_CRIT_LOW:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 9ee4d857346541c6870586a0c7989fc5
|
|
name: '{#SENSOR_LOCATION}.Ambient: Temperature'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.44.1.4.{#SNMPINDEX}]'
|
|
key: 'sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
value_type: FLOAT
|
|
units: °C
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
|
|
Temperature readings of testpoint: {#SENSOR_LOCATION}.Ambient
|
|
tags:
|
|
- tag: component
|
|
value: temperature
|
|
trigger_prototypes:
|
|
- uuid: 4e293138ca374c96a18e4dbca8e45c72
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Ambient"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: cf21a0259b6e4402815651357cdcce76
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"Ambient"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold: >{$TEMP_WARN:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold'
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"}'
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Ambient"}-3'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 5139f8dd56094561a573a0b7b15a5ef0
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'min(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"Ambient"}+3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Ambient: Temperature is too low'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Ambient: Temperature is too low: <{$TEMP_CRIT_LOW:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 9dc8ac1ccf2a4671bef441db6297b2f9
|
|
name: '{#SENSOR_LOCATION}.Front: Temperature'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.44.1.8.{#SNMPINDEX}]'
|
|
key: 'sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
value_type: FLOAT
|
|
units: °C
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
|
|
Cisco UCS compute:RackUnitMbTempStats:frontTemp managed object property
|
|
tags:
|
|
- tag: component
|
|
value: temperature
|
|
trigger_prototypes:
|
|
- uuid: 98b9a6bd22e648e1bce3e5ee3ed5f6b4
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Ambient"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Front: Temperature is above critical threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 068f42b490ad41eb97a65dbc718ae566
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"Ambient"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Front: Temperature is above warning threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Front: Temperature is above warning threshold: >{$TEMP_WARN:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#SENSOR_LOCATION}.Front: Temperature is above critical threshold'
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"}'
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Ambient"}-3'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: f208cad426cf45338b6487cf87588220
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'min(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"Ambient"}+3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Front: Temperature is too low'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Front: Temperature is too low: <{$TEMP_CRIT_LOW:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 631d46aad1b2403b9512299e2446a24e
|
|
name: '{#SENSOR_LOCATION}.Rear: Temperature'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.44.1.21.{#SNMPINDEX}]'
|
|
key: 'sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
value_type: FLOAT
|
|
units: °C
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
|
|
Cisco UCS compute:RackUnitMbTempStats:rearTemp managed object property
|
|
tags:
|
|
- tag: component
|
|
value: temperature
|
|
trigger_prototypes:
|
|
- uuid: ef03cd1e2356409ea2651fab589c9d19
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Ambient"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP_CRIT:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: ed302fd9bdbe47cda2456aa7cdc6ce66
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP_WARN:"Ambient"}-3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Rear: Temperature is above warning threshold'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Rear: Temperature is above warning threshold: >{$TEMP_WARN:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold'
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"}'
|
|
recovery_expression: 'max(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"Ambient"}-3'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: bb81b628d804411480d3b4066d626f82
|
|
expression: 'avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"}'
|
|
recovery_mode: RECOVERY_EXPRESSION
|
|
recovery_expression: 'min(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"Ambient"}+3'
|
|
name: 'Cisco UCS: {#SENSOR_LOCATION}.Rear: Temperature is too low'
|
|
event_name: 'Cisco UCS: {#SENSOR_LOCATION}.Rear: Temperature is too low: <{$TEMP_CRIT_LOW:"Ambient"}'
|
|
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
|
priority: AVERAGE
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: 0a96ab839bde40cf9d1d4db602c57a5e
|
|
name: 'Unit Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#UNIT_LOCATION},1.3.6.1.4.1.9.9.719.1.9.35.1.2]'
|
|
key: unit.discovery
|
|
delay: 1h
|
|
item_prototypes:
|
|
- uuid: 9d0f6f5594a24c588da63fd29bf2152f
|
|
name: '{#UNIT_LOCATION}: Hardware model name'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.35.1.32.{#SNMPINDEX}]'
|
|
key: 'system.hw.model[cucsComputeRackUnitModel.{#SNMPINDEX}]'
|
|
delay: 1h
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
|
|
Cisco UCS compute:RackUnit:model managed object property
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 1d
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
- uuid: b0c955f0fc184c6686fa2fe3fce29f1a
|
|
name: '{#UNIT_LOCATION}: Hardware serial number'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.35.1.47.{#SNMPINDEX}]'
|
|
key: 'system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]'
|
|
delay: 1h
|
|
value_type: CHAR
|
|
trends: '0'
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
|
|
Cisco UCS compute:RackUnit:serial managed object property
|
|
preprocessing:
|
|
- type: DISCARD_UNCHANGED_HEARTBEAT
|
|
parameters:
|
|
- 1d
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
trigger_prototypes:
|
|
- uuid: b9667c535fe542eeb21dea7aaf2bbf80
|
|
expression: 'last(/Cisco UCS by SNMP/system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#1)<>last(/Cisco UCS by SNMP/system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#2) and length(last(/Cisco UCS by SNMP/system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]))>0'
|
|
name: 'Cisco UCS: {#UNIT_LOCATION}: Device has been replaced'
|
|
event_name: 'Cisco UCS: {#UNIT_LOCATION}: Device has been replaced (new serial number received)'
|
|
priority: INFO
|
|
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
|
|
manual_close: 'YES'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|
|
- uuid: 00a0fe6510064375a1736433a17904c0
|
|
name: '{#UNIT_LOCATION}: Overall system health status'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.35.1.42.{#SNMPINDEX}]'
|
|
key: 'system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}]'
|
|
delay: 30s
|
|
trends: '0'
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
|
|
Cisco UCS compute:RackUnit:operState managed object property
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsLsOperState'
|
|
tags:
|
|
- tag: component
|
|
value: system
|
|
trigger_prototypes:
|
|
- uuid: 70fbf187bc474aa88a26fb5a8d862694
|
|
expression: 'count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"computeFailed\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"configFailure\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"unconfigFailure\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"inoperable\"}")=1'
|
|
name: 'Cisco UCS: {#UNIT_LOCATION}: System status is in critical state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: HIGH
|
|
description: 'Please check the device for errors'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: b69f6876b7de4e1c89934281696249c8
|
|
expression: 'count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"testFailed\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"thermalProblem\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"powerProblem\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"voltageProblem\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"diagnosticsFailed\"}")=1'
|
|
name: 'Cisco UCS: {#UNIT_LOCATION}: System status is in warning state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check the device for warnings'
|
|
dependencies:
|
|
- name: 'Cisco UCS: {#UNIT_LOCATION}: System status is in critical state'
|
|
expression: 'count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"computeFailed\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"configFailure\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"unconfigFailure\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"inoperable\"}")=1'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
- uuid: b76c04b65a8348539434d8857d1450aa
|
|
name: 'Virtual Disk Discovery'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'discovery[{#VDISK_LOCATION},1.3.6.1.4.1.9.9.719.1.45.8.1.2]'
|
|
key: virtualdisk.discovery
|
|
delay: 1h
|
|
description: 'CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalLunTable'
|
|
item_prototypes:
|
|
- uuid: 0c6d53aae84e41fa9bdccf06a51bbf21
|
|
name: '{#VDISK_LOCATION}: Layout type'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.8.1.14.{#SNMPINDEX}]'
|
|
key: 'system.hw.virtualdisk.layout[cucsStorageLocalLunType.{#SNMPINDEX}]'
|
|
delay: 1h
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
|
|
Cisco UCS storage:LocalLun:type managed object property
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType'
|
|
tags:
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: db7e07e0325145d0a8f6bcef0cd0dff2
|
|
name: '{#VDISK_LOCATION}: Disk size'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.8.1.13.{#SNMPINDEX}]'
|
|
key: 'system.hw.virtualdisk.size[cucsStorageLocalLunSize.{#SNMPINDEX}]'
|
|
delay: 1h
|
|
trends: '0'
|
|
units: B
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
|
|
Cisco UCS storage:LocalLun:size managed object property in MB.
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType'
|
|
preprocessing:
|
|
- type: MULTIPLIER
|
|
parameters:
|
|
- '1048576'
|
|
tags:
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
- uuid: 5c0d7116c19940608ca40058e47fd595
|
|
name: '{#VDISK_LOCATION}: Status'
|
|
type: SNMP_AGENT
|
|
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.8.1.10.{#SNMPINDEX}]'
|
|
key: 'system.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}]'
|
|
delay: 3m
|
|
description: |
|
|
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
|
|
Cisco UCS storage:LocalLun:presence managed object property
|
|
valuemap:
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentPresence'
|
|
tags:
|
|
- tag: component
|
|
value: disk
|
|
- tag: component
|
|
value: storage
|
|
trigger_prototypes:
|
|
- uuid: 97b0c8177dca421f9535cb6f0abea7aa
|
|
expression: 'count(/Cisco UCS by SNMP/system.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}],#1,"ne","{$VDISK_OK_STATUS:\"equipped\"}")=1'
|
|
name: 'Cisco UCS: {#VDISK_LOCATION}: Virtual disk is not in OK state'
|
|
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
|
priority: WARNING
|
|
description: 'Please check virtual disk for warnings or errors'
|
|
tags:
|
|
- tag: scope
|
|
value: availability
|
|
- tag: scope
|
|
value: performance
|
|
tags:
|
|
- tag: class
|
|
value: hardware
|
|
- tag: target
|
|
value: cisco
|
|
- tag: target
|
|
value: cisco-ucs
|
|
macros:
|
|
- macro: '{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS}'
|
|
value: '2'
|
|
- macro: '{$DISK_ARRAY_CACHE_BATTERY_OK_STATUS}'
|
|
value: '1'
|
|
- macro: '{$DISK_ARRAY_CRIT_STATUS:"inoperable"}'
|
|
value: '2'
|
|
- macro: '{$DISK_ARRAY_OK_STATUS:"operable"}'
|
|
value: '1'
|
|
- macro: '{$DISK_ARRAY_WARN_STATUS:"degraded"}'
|
|
value: '3'
|
|
- macro: '{$DISK_CRIT_STATUS:"bad"}'
|
|
value: '16'
|
|
- macro: '{$DISK_CRIT_STATUS:"predictiveFailure"}'
|
|
value: '11'
|
|
- macro: '{$DISK_FAIL_STATUS:"failed"}'
|
|
value: '9'
|
|
- macro: '{$FAN_CRIT_STATUS:"inoperable"}'
|
|
value: '2'
|
|
- macro: '{$FAN_WARN_STATUS:"degraded"}'
|
|
value: '3'
|
|
- macro: '{$HEALTH_CRIT_STATUS:"computeFailed"}'
|
|
value: '30'
|
|
- macro: '{$HEALTH_CRIT_STATUS:"configFailure"}'
|
|
value: '33'
|
|
- macro: '{$HEALTH_CRIT_STATUS:"inoperable"}'
|
|
value: '60'
|
|
- macro: '{$HEALTH_CRIT_STATUS:"unconfigFailure"}'
|
|
value: '34'
|
|
- macro: '{$HEALTH_WARN_STATUS:"diagnosticsFailed"}'
|
|
value: '204'
|
|
- macro: '{$HEALTH_WARN_STATUS:"powerProblem"}'
|
|
value: '62'
|
|
- macro: '{$HEALTH_WARN_STATUS:"testFailed"}'
|
|
value: '35'
|
|
- macro: '{$HEALTH_WARN_STATUS:"thermalProblem"}'
|
|
value: '60'
|
|
- macro: '{$HEALTH_WARN_STATUS:"voltageProblem"}'
|
|
value: '62'
|
|
- macro: '{$ICMP_LOSS_WARN}'
|
|
value: '20'
|
|
description: 'Warning threshold of ICMP packet loss in %.'
|
|
- macro: '{$ICMP_RESPONSE_TIME_WARN}'
|
|
value: '0.15'
|
|
description: 'Warning threshold of the average ICMP response time in seconds.'
|
|
- macro: '{$PSU_CRIT_STATUS:"inoperable"}'
|
|
value: '2'
|
|
- macro: '{$PSU_WARN_STATUS:"degraded"}'
|
|
value: '3'
|
|
- macro: '{$SNMP.TIMEOUT}'
|
|
value: 5m
|
|
description: 'Time interval for the SNMP availability trigger.'
|
|
- macro: '{$TEMP_CRIT}'
|
|
value: '60'
|
|
- macro: '{$TEMP_CRIT:"Ambient"}'
|
|
value: '35'
|
|
- macro: '{$TEMP_CRIT_LOW}'
|
|
value: '5'
|
|
- macro: '{$TEMP_WARN}'
|
|
value: '50'
|
|
- macro: '{$TEMP_WARN:"Ambient"}'
|
|
value: '30'
|
|
- macro: '{$VDISK_OK_STATUS:"equipped"}'
|
|
value: '10'
|
|
valuemaps:
|
|
- uuid: e1686896f31e483f9add962dbbd90afb
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: unknown
|
|
- value: '1'
|
|
newvalue: operable
|
|
- value: '2'
|
|
newvalue: inoperable
|
|
- value: '3'
|
|
newvalue: degraded
|
|
- value: '4'
|
|
newvalue: poweredOff
|
|
- value: '5'
|
|
newvalue: powerProblem
|
|
- value: '6'
|
|
newvalue: removed
|
|
- value: '7'
|
|
newvalue: voltageProblem
|
|
- value: '8'
|
|
newvalue: thermalProblem
|
|
- value: '9'
|
|
newvalue: performanceProblem
|
|
- value: '10'
|
|
newvalue: accessibilityProblem
|
|
- value: '11'
|
|
newvalue: identityUnestablishable
|
|
- value: '12'
|
|
newvalue: biosPostTimeout
|
|
- value: '13'
|
|
newvalue: disabled
|
|
- value: '14'
|
|
newvalue: malformedFru
|
|
- value: '15'
|
|
newvalue: backplanePortProblem
|
|
- value: '16'
|
|
newvalue: chassisIntrusion
|
|
- value: '51'
|
|
newvalue: fabricConnProblem
|
|
- value: '52'
|
|
newvalue: fabricUnsupportedConn
|
|
- value: '81'
|
|
newvalue: config
|
|
- value: '82'
|
|
newvalue: equipmentProblem
|
|
- value: '83'
|
|
newvalue: decommissioning
|
|
- value: '84'
|
|
newvalue: chassisLimitExceeded
|
|
- value: '100'
|
|
newvalue: notSupported
|
|
- value: '101'
|
|
newvalue: discovery
|
|
- value: '102'
|
|
newvalue: discoveryFailed
|
|
- value: '103'
|
|
newvalue: identify
|
|
- value: '104'
|
|
newvalue: postFailure
|
|
- value: '105'
|
|
newvalue: upgradeProblem
|
|
- value: '106'
|
|
newvalue: peerCommProblem
|
|
- value: '107'
|
|
newvalue: autoUpgrade
|
|
- value: '108'
|
|
newvalue: linkActivateBlocked
|
|
- uuid: 5055674c42a241e3a2156de1dc1715bf
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentPresence'
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: unknown
|
|
- value: '1'
|
|
newvalue: empty
|
|
- value: '10'
|
|
newvalue: equipped
|
|
- value: '11'
|
|
newvalue: missing
|
|
- value: '12'
|
|
newvalue: mismatch
|
|
- value: '13'
|
|
newvalue: equippedNotPrimary
|
|
- value: '14'
|
|
newvalue: equippedSlave
|
|
- value: '15'
|
|
newvalue: mismatchSlave
|
|
- value: '16'
|
|
newvalue: missingSlave
|
|
- value: '20'
|
|
newvalue: equippedIdentityUnestablishable
|
|
- value: '21'
|
|
newvalue: mismatchIdentityUnestablishable
|
|
- value: '22'
|
|
newvalue: equippedWithMalformedFru
|
|
- value: '30'
|
|
newvalue: inaccessible
|
|
- value: '40'
|
|
newvalue: unauthorized
|
|
- value: '100'
|
|
newvalue: notSupported
|
|
- value: '101'
|
|
newvalue: equippedUnsupported
|
|
- value: '102'
|
|
newvalue: equippedDiscNotStarted
|
|
- value: '103'
|
|
newvalue: equippedDiscInProgress
|
|
- value: '104'
|
|
newvalue: equippedDiscError
|
|
- value: '105'
|
|
newvalue: equippedDiscUnknown
|
|
- uuid: 398aa5bf5eb44a8c8dd96babd98f1bd3
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsLsOperState'
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: indeterminate
|
|
- value: '1'
|
|
newvalue: unassociated
|
|
- value: '10'
|
|
newvalue: ok
|
|
- value: '11'
|
|
newvalue: discovery
|
|
- value: '12'
|
|
newvalue: config
|
|
- value: '13'
|
|
newvalue: unconfig
|
|
- value: '14'
|
|
newvalue: powerOff
|
|
- value: '15'
|
|
newvalue: restart
|
|
- value: '20'
|
|
newvalue: maintenance
|
|
- value: '21'
|
|
newvalue: test
|
|
- value: '29'
|
|
newvalue: computeMismatch
|
|
- value: '30'
|
|
newvalue: computeFailed
|
|
- value: '31'
|
|
newvalue: degraded
|
|
- value: '32'
|
|
newvalue: discoveryFailed
|
|
- value: '33'
|
|
newvalue: configFailure
|
|
- value: '34'
|
|
newvalue: unconfigFailed
|
|
- value: '35'
|
|
newvalue: testFailed
|
|
- value: '36'
|
|
newvalue: maintenanceFailed
|
|
- value: '40'
|
|
newvalue: removed
|
|
- value: '41'
|
|
newvalue: disabled
|
|
- value: '50'
|
|
newvalue: inaccessible
|
|
- value: '60'
|
|
newvalue: thermalProblem
|
|
- value: '61'
|
|
newvalue: powerProblem
|
|
- value: '62'
|
|
newvalue: voltageProblem
|
|
- value: '63'
|
|
newvalue: inoperable
|
|
- value: '101'
|
|
newvalue: decommissioning
|
|
- value: '201'
|
|
newvalue: biosRestore
|
|
- value: '202'
|
|
newvalue: cmosReset
|
|
- value: '203'
|
|
newvalue: diagnostics
|
|
- value: '204'
|
|
newvalue: diagnosticsFailed
|
|
- value: '210'
|
|
newvalue: pendingReboot
|
|
- value: '211'
|
|
newvalue: pendingReassociation
|
|
- value: '212'
|
|
newvalue: svnicNotPresent
|
|
- uuid: 7d3e38476c894ae59ecac6640b24f833
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType'
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: unspecified
|
|
- value: '1'
|
|
newvalue: simple
|
|
- value: '2'
|
|
newvalue: mirror
|
|
- value: '3'
|
|
newvalue: stripe
|
|
- value: '4'
|
|
newvalue: raid
|
|
- value: '5'
|
|
newvalue: stripeParity
|
|
- value: '6'
|
|
newvalue: stripeDualParity
|
|
- value: '7'
|
|
newvalue: mirrorStripe
|
|
- value: '8'
|
|
newvalue: stripeParityStripe
|
|
- value: '9'
|
|
newvalue: stripeDualParityStripe
|
|
- uuid: 9b7c7078039c4e348ab417da71b96f5c
|
|
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStoragePDriveStatus'
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: unknown
|
|
- value: '1'
|
|
newvalue: online
|
|
- value: '2'
|
|
newvalue: unconfiguredGood
|
|
- value: '3'
|
|
newvalue: globalHotSpare
|
|
- value: '4'
|
|
newvalue: dedicatedHotSpare
|
|
- value: '5'
|
|
newvalue: jbod
|
|
- value: '6'
|
|
newvalue: offline
|
|
- value: '7'
|
|
newvalue: rebuilding
|
|
- value: '8'
|
|
newvalue: copyback
|
|
- value: '9'
|
|
newvalue: failed
|
|
- value: '10'
|
|
newvalue: unconfiguredBad
|
|
- value: '11'
|
|
newvalue: predictiveFailure
|
|
- value: '12'
|
|
newvalue: disabledForRemoval
|
|
- value: '13'
|
|
newvalue: foreignConfiguration
|
|
- value: '14'
|
|
newvalue: zeroing
|
|
- value: '15'
|
|
newvalue: good
|
|
- value: '16'
|
|
newvalue: bad
|
|
- value: '17'
|
|
newvalue: lockedForeignConfiguration
|
|
- uuid: b98830da69f9463f949ed2df7ee5dcb3
|
|
name: 'Service state'
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: Down
|
|
- value: '1'
|
|
newvalue: Up
|
|
- uuid: a67fce1a203742eea56849fc38b8af39
|
|
name: zabbix.host.available
|
|
mappings:
|
|
- value: '0'
|
|
newvalue: 'not available'
|
|
- value: '1'
|
|
newvalue: available
|
|
- value: '2'
|
|
newvalue: unknown
|
|
triggers:
|
|
- uuid: a933ba0e5c7f4e908afaba4381f65482
|
|
expression: '(last(/Cisco UCS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco UCS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco UCS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco UCS by SNMP/system.net.uptime[sysUpTime.0])<10m)'
|
|
name: 'Cisco UCS: Host has been restarted'
|
|
event_name: 'Cisco UCS: {HOST.NAME} has been restarted (uptime < 10m)'
|
|
priority: WARNING
|
|
description: 'Uptime is less than 10 minutes.'
|
|
manual_close: 'YES'
|
|
dependencies:
|
|
- name: 'Cisco UCS: No SNMP data collection'
|
|
expression: 'max(/Cisco UCS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
|
|
tags:
|
|
- tag: scope
|
|
value: notice
|