Files
templates-default/Cisco_UCS_Manager_by_SNMP.yaml

2595 lines
117 KiB
YAML

zabbix_export:
version: '7.0'
template_groups:
- uuid: e960332b3f6c46a1956486d4f3f99fce
name: 'Templates/Server hardware'
templates:
- uuid: d5eb4ce08a334098a85e6e02c534be90
template: 'Cisco UCS Manager by SNMP'
name: 'Cisco UCS Manager by SNMP'
description: |
This is a template for Cisco UCS Manager monitoring via Zabbix SNMP Agent that works without any external scripts.
MIBs used:
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
IF-MIB
HOST-RESOURCES-MIB
SNMPv2-MIB
CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
CISCO-UNIFIED-COMPUTING-STORAGE-MIB
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/418396-discussion-thread-for-official-zabbix-templates-for-cisco
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-4
groups:
- name: 'Templates/Server hardware'
items:
- uuid: ad342e11ce9f4f79bf9b0182c3f83488
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: 'cisco.ucs.contact[sysContact.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The textual identification of the contact person for this managed
node, together with information on how to contact this person. If no contact
information is known, the value is the zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
- uuid: 286fdb0fa49a4b378a6219a5ed76aac4
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: 'cisco.ucs.descr[sysDescr.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should
include the full name and version identification of the system's hardware type, software operating-system, and
networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
- uuid: 5af56ed99d09489aafc2d08d4bd4903a
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]'
key: 'cisco.ucs.hw.uptime[hrSystemUptime.0]'
delay: 30s
trends: '0'
units: uptime
description: |
MIB: HOST-RESOURCES-MIB
The amount of time since this host was last initialized.
Note that this is different from sysUpTime in the SNMPv2-MIB
[RFC1907] because sysUpTime is the uptime of the
network management portion of the system.
preprocessing:
- type: CHECK_NOT_SUPPORTED
parameters:
- '-1'
error_handler: CUSTOM_VALUE
error_handler_params: '0'
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: 88bd32f8520144858a8ddb03dd200638
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: 'cisco.ucs.location[sysLocation.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., `telephone closet,
3rd floor'). If the location is unknown, the value is the zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
- uuid: 8bd3a60e4c70450492432c6abfa7b5f9
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: 'cisco.ucs.name[sysName.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node.By
convention, this is the node's fully-qualified domain name. If the name is unknown,
the value is the zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
triggers:
- uuid: 622ac72c0e534bba94bb93636e4dc103
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.name[sysName.0],#1)<>last(/Cisco UCS Manager by SNMP/cisco.ucs.name[sysName.0],#2) and length(last(/Cisco UCS Manager by SNMP/cisco.ucs.name[sysName.0]))>0'
name: 'Cisco UCS Manager: System name has changed'
event_name: 'Cisco UCS Manager: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: b87e425f1bdf404a8e53ff277c0ff0c0
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.3.0]'
key: 'cisco.ucs.net.uptime[sysUpTime.0]'
delay: 30s
trends: '0'
units: uptime
description: |
MIB: SNMPv2-MIB
The time in seconds since the network management
portion of the system was last re-initialized.
preprocessing:
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: 10d22e53318347658b2418ff33c26e0d
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: 'cisco.ucs.objectid[sysObjectID.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the network management
subsystem contained in the entity. This value is allocated within the SMI enterprises
subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining 'what
kind of box' is being managed. For example, if vendor 'Flintstones, Inc.' was
assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1
to its 'Fred Router'.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
- uuid: 5d839f68b6534dc8bd1fb5db7a757f02
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: network
- uuid: 0926417e279a4e52a7f12587e9422e92
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
description: |
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
Possible values:
0 - not available
1 - available
2 - unknown
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: 010a749e3a3242cd8e3ea30459fae5a4
expression: 'max(/Cisco UCS Manager by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
name: 'Cisco UCS Manager: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: f44bb3e5a8ad4d0c98df56267700b171
name: 'Array controller cache discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#DISKARRAY_CACHE_LOCATION},1.3.6.1.4.1.9.9.719.1.45.11.1.2]'
key: cisco.ucs.array.cache.discovery
delay: 1h
description: 'Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.'
item_prototypes:
- uuid: 4e5214066fbb4c719c7e6abfba47e5f6
name: '{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.11.1.9.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}]'
trends: '0'
description: 'MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB'
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: array
- tag: component
value: disk
- tag: component
value: storage
trigger_prototypes:
- uuid: 0300b4bf4e0b42adb1b9e4985e80e356
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
name: 'Cisco UCS Manager: {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 158561ecab8b4bbd9c0a616f419bda10
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
name: 'Cisco UCS Manager: {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is not in optimal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults'
dependencies:
- name: 'Cisco UCS Manager: {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!'
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: bd1cf5ecd41f4dc49c6e31f32119787b
name: 'Array controller discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#DISKARRAY_LOCATION},1.3.6.1.4.1.9.9.719.1.45.1.1.2]'
key: cisco.ucs.array.discovery
delay: 1h
description: 'Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.'
item_prototypes:
- uuid: 5285422113b84c2e8cb00899e0b29493
name: '{#DISKARRAY_LOCATION}: Disk array controller model'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.1.1.5.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.diskarray.model[cucsStorageControllerModel.{#SNMPINDEX}]'
delay: 1d
value_type: CHAR
trends: '0'
description: 'MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: array
- tag: component
value: disk
- tag: component
value: storage
- uuid: a732688d6fa347b597854078dd084935
name: '{#DISKARRAY_LOCATION}: Disk array controller status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.1.1.6.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:RaidBattery:operability managed object property.
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: array
- tag: component
value: disk
- tag: component
value: storage
trigger_prototypes:
- uuid: 28c32222815f47e193d09afe5aafae79
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT:"inoperable"}'
name: 'Cisco UCS Manager: {#DISKARRAY_LOCATION}: Disk array controller is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 4e758fac4df54388b5f4555bb170bdd3
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN:"degraded"}'
name: 'Cisco UCS Manager: {#DISKARRAY_LOCATION}: Disk array controller is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults'
dependencies:
- name: 'Cisco UCS Manager: {#DISKARRAY_LOCATION}: Disk array controller is in critical state'
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT:"inoperable"}'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 264e15d04626432987c2193bf190c56c
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])>{$DISK.ARRAY.STATUS.OK:"operable"}'
name: 'Cisco UCS Manager: {#DISKARRAY_LOCATION}: Disk array controller is not in optimal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults'
dependencies:
- name: 'Cisco UCS Manager: {#DISKARRAY_LOCATION}: Disk array controller is in critical state'
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT:"inoperable"}'
- name: 'Cisco UCS Manager: {#DISKARRAY_LOCATION}: Disk array controller is in warning state'
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN:"degraded"}'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: c799941bb99a4ce0af2ab50253c40259
name: 'FAN discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#FAN_LOCATION},1.3.6.1.4.1.9.9.719.1.15.12.1.2]'
key: cisco.ucs.fan.discovery
delay: 1h
item_prototypes:
- uuid: 5e4aa59c4ec44fc7b97b9659c0d7a5c5
name: '{#FAN_LOCATION}: Fan status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.15.12.1.9.{#SNMPINDEX}]'
key: 'cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}]'
delay: 3m
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
Cisco UCS equipment:Fan:operState managed object property
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: fan
trigger_prototypes:
- uuid: 7417bd7646c248eb9664875d7d19e9ea
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"inoperable"}'
name: 'Cisco UCS Manager: {#FAN_LOCATION}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: b3d6cb64470e4e4c9bf1d619c0015823
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}])={$FAN.STATUS.WARN:"degraded"}'
name: 'Cisco UCS Manager: {#FAN_LOCATION}: Fan is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit'
dependencies:
- name: 'Cisco UCS Manager: {#FAN_LOCATION}: Fan is in critical state'
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}])={$FAN.STATUS.CRIT:"inoperable"}'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 20b43c2620114a9da4ff4d97b409f53e
name: 'Network interface discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]'
key: cisco.ucs.net.if.discovery
delay: 1h
filter:
evaltype: AND
conditions:
- macro: '{#IFADMINSTATUS}'
value: '{$NET.IFADMINSTATUS.MATCHES}'
formulaid: A
- macro: '{#IFADMINSTATUS}'
value: '{$NET.IFADMINSTATUS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#IFALIAS}'
value: '{$NET.IFALIAS.MATCHES}'
formulaid: C
- macro: '{#IFALIAS}'
value: '{$NET.IFALIAS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
- macro: '{#IFDESCR}'
value: '{$NET.IFDESCR.MATCHES}'
formulaid: E
- macro: '{#IFDESCR}'
value: '{$NET.IFDESCR.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: F
- macro: '{#IFNAME}'
value: '{$NET.IFNAME.MATCHES}'
formulaid: G
- macro: '{#IFNAME}'
value: '{$NET.IFNAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: H
- macro: '{#IFOPERSTATUS}'
value: '{$NET.IFOPERSTATUS.MATCHES}'
formulaid: I
- macro: '{#IFOPERSTATUS}'
value: '{$NET.IFOPERSTATUS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: J
- macro: '{#IFTYPE}'
value: '{$NET.IFTYPE.MATCHES}'
formulaid: K
- macro: '{#IFTYPE}'
value: '{$NET.IFTYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: L
description: 'Discovering interfaces from IF-MIB.'
item_prototypes:
- uuid: 361a4c5a4b04432b84f4e6bfcd7775c6
name: 'Interface {#IFNAME}({#IFALIAS}): Interface description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.2.{#SNMPINDEX}]'
key: 'cisco.ucs.if.descr[ifDescr.{#SNMPINDEX}]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IF-MIB
A textual string containing information about the
interface. This string should include the name of the
manufacturer, the product name and the version of the
interface hardware/software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 009aeec02b3b46dc93bd52c2f1a4de0a
name: 'Interface {#IFNAME}({#IFALIAS}): Broadcast packets received'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.9.{#SNMPINDEX}]'
key: 'cisco.ucs.if.in.broadcast[ifHCInBroadcastPkts.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
The number of packets, delivered by this sub-layer to a
higher (sub-)layer, which were addressed to a broadcast
address at this sub-layer. This object is a 64-bit version
of ifInBroadcastPkts.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 533b7352983e4adfbd9ca1c0e2e5e4b1
name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}]'
key: 'cisco.ucs.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
The number of inbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 84e21f59350248c185a79dd916587140
name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}]'
key: 'cisco.ucs.if.in.errors[ifInErrors.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: d72b570e01f5479db47628e399932988
name: 'Interface {#IFNAME}({#IFALIAS}): Multicast packets received'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.8.{#SNMPINDEX}]'
key: 'cisco.ucs.if.in.multicast[ifHCInMulticastPkts.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
The number of packets, delivered by this sub-layer to a
higher (sub-)layer, which were addressed to a multicast
address at this sub-layer. For a MAC layer protocol, this
includes both Group and Functional addresses. This object
is a 64-bit version of ifInMulticastPkts.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: eef7c3f6945a48e886de08a842c08f72
name: 'Interface {#IFNAME}({#IFALIAS}): Bits received'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}]'
key: 'cisco.ucs.if.in[ifHCInOctets.{#SNMPINDEX}]'
delay: 3m
units: bps
description: |
MIB: IF-MIB
The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
- type: MULTIPLIER
parameters:
- '8'
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: f682fdf3144145f3998066a77353c4e2
name: 'Interface {#IFNAME}({#IFALIAS}): Broadcast packets sent'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.13.{#SNMPINDEX}]'
key: 'cisco.ucs.if.out.broadcast[ifHCOutBroadcastPkts.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
The total number of packets that higher-level protocols
requested be transmitted, and which were addressed to a
broadcast address at this sub-layer, including those that
were discarded or not sent. This object is a 64-bit version
of ifOutBroadcastPkts.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: b61c1b8a08aa40d696d03ae584230e8e
name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}]'
key: 'cisco.ucs.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
The number of outbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 0b9d7feb75674225ac8e6ad0952380ac
name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}]'
key: 'cisco.ucs.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 3ddc4cca78f14dfc8e6d51efae831ba2
name: 'Interface {#IFNAME}({#IFALIAS}): Multicast packets sent'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.12.{#SNMPINDEX}]'
key: 'cisco.ucs.if.out.multicast[ifHCOutMulticastPkts.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
The total number of packets that higher-level protocols
requested be transmitted, and which were addressed to a
multicast address at this sub-layer, including those that
were discarded or not sent. For a MAC layer protocol, this
includes both Group and Functional addresses. This object
is a 64-bit version of ifOutMulticastPkts.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other
times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: e48a1926828645c49afec898d01fa81a
name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}]'
key: 'cisco.ucs.if.out[ifHCOutOctets.{#SNMPINDEX}]'
delay: 3m
units: bps
description: |
MIB: IF-MIB
The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
- type: MULTIPLIER
parameters:
- '8'
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 56aa529b14b14f6f8f9a9b5f1a2ba0d8
name: 'Interface {#IFNAME}({#IFALIAS}): Speed'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}]'
key: 'cisco.ucs.if.speed[ifHighSpeed.{#SNMPINDEX}]'
delay: 5m
trends: '0'
units: bps
description: |
MIB: IF-MIB
An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.
preprocessing:
- type: MULTIPLIER
parameters:
- '1000000'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 16a4394c6b824bacbc7f074d487fcdfb
name: 'Interface {#IFNAME}({#IFALIAS}): Operational status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}]'
key: 'cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: IF-MIB
The current operational state of the interface.
- The testing(3) state indicates that no operational packet scan be passed
- If ifAdminStatus is down(2) then ifOperStatus should be down(2)
- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic
- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)
- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state
- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.
valuemap:
name: 'IF-MIB::ifOperStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: edfbf339b2664fae88e2a9003383e37f
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco UCS Manager by SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco UCS Manager by SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager by SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
name: 'Cisco UCS Manager: Interface {#IFNAME}({#IFALIAS}): Link down'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is down.
2. `{ $IFCONTROL:"{#IFNAME}" }=1` - a user can redefine context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.
3. The trigger fires only if the operational status was up to (1) sometime before (so, do not fire for the 'eternal off' interfaces.)
WARNING: if closed manually - it will not fire again on the next poll, because of .diff.
manual_close: 'YES'
tags:
- tag: scope
value: availability
- uuid: 00b0f0fb6c0b4026b438627edab908fb
name: 'Interface {#IFNAME}({#IFALIAS}): Interface type'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}]'
key: 'cisco.ucs.if.type[ifType.{#SNMPINDEX}]'
delay: 1h
trends: '0'
description: |
MIB: IF-MIB
The type of interface.
Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA),
through updating the syntax of the IANAifType textual convention.
valuemap:
name: 'IF-MIB::ifType'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: caaa61b8d89540c496678d739610ae38
expression: |
min(/Cisco UCS Manager by SNMP/cisco.ucs.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
or min(/Cisco UCS Manager by SNMP/cisco.ucs.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
name: 'Cisco UCS Manager: Interface {#IFNAME}({#IFALIAS}): High error rate on {#IFNAME}'
event_name: 'Cisco UCS Manager: Interface {#IFNAME}({#IFALIAS}): High error rate on {#IFNAME} ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'Recovers when value below {$IF.ERRORS.WARN:"{#IFNAME}"} threshold.'
manual_close: 'YES'
dependencies:
- name: 'Cisco UCS Manager: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Cisco UCS Manager by SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Cisco UCS Manager by SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager by SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
- tag: scope
value: performance
graph_prototypes:
- uuid: d5e5f60602cc41ba8e0b79a63644bf08
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
graph_items:
- drawtype: GRADIENT_LINE
color: 199C0D
item:
host: 'Cisco UCS Manager by SNMP'
key: 'cisco.ucs.if.in[ifHCInOctets.{#SNMPINDEX}]'
- sortorder: '1'
drawtype: BOLD_LINE
color: F63100
item:
host: 'Cisco UCS Manager by SNMP'
key: 'cisco.ucs.if.out[ifHCOutOctets.{#SNMPINDEX}]'
- sortorder: '2'
color: 00611C
yaxisside: RIGHT
item:
host: 'Cisco UCS Manager by SNMP'
key: 'cisco.ucs.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
- sortorder: '3'
color: F7941D
yaxisside: RIGHT
item:
host: 'Cisco UCS Manager by SNMP'
key: 'cisco.ucs.if.in.errors[ifInErrors.{#SNMPINDEX}]'
- sortorder: '4'
color: FC6EA3
yaxisside: RIGHT
item:
host: 'Cisco UCS Manager by SNMP'
key: 'cisco.ucs.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
- sortorder: '5'
color: 6C59DC
yaxisside: RIGHT
item:
host: 'Cisco UCS Manager by SNMP'
key: 'cisco.ucs.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
preprocessing:
- type: JAVASCRIPT
parameters:
- |
var result = [];
JSON.parse(value).forEach(function (netif) {
if (typeof netif["{#IFNAME}"] === 'undefined') {
netif["{#IFNAME}"] = netif["{#IFDESCR}"];
}
if (typeof netif["{#IFALIAS}"] === 'undefined') {
netif["{#IFALIAS}"] = "";
}
result.push(netif);
});
return JSON.stringify(result);
- uuid: a8794333ae2c4104ac52c6ce421161fd
name: 'Physical disk discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#DISK_LOCATION},1.3.6.1.4.1.9.9.719.1.45.4.1.2]'
key: cisco.ucs.physicalDisk.discovery
delay: 1h
description: 'Scanning table of physical drive entries CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskTable.'
item_prototypes:
- uuid: 3a1f21ccf92f43df869f66911ab5c0ea
name: '{#DISK_LOCATION}: Physical disk media type'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.17.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.physicaldisk.media_type[cucsStorageLocalDiskDeviceType.{#SNMPINDEX}]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:deviceType managed object property. Actually returns 'HDD' or 'SSD'.
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageTechnology'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: disk
- tag: component
value: storage
- uuid: 317d489e9bf94467a228f5bbccb03436
name: '{#DISK_LOCATION}: Physical disk model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.7.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.physicaldisk.model[cucsStorageLocalDiskModel.{#SNMPINDEX}]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:model managed object property.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: disk
- tag: component
value: storage
- uuid: d768239496f2457fbec3a1103e84914d
name: '{#DISK_LOCATION}: Physical disk serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.12.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:serial managed object property. Actually returns part number code.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: disk
- tag: component
value: storage
trigger_prototypes:
- uuid: 693cdcf58cb34def90ade23e2f2485cb
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}],#2) and length(last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.physicaldisk.serialnumber[cucsStorageLocalDiskSerial.{#SNMPINDEX}]))>0'
name: 'Cisco UCS Manager: {#DISK_LOCATION}: Disk has been replaced'
event_name: 'Cisco UCS Manager: {#DISK_LOCATION}: Disk has been replaced (new serial number received)'
priority: INFO
description: 'Disk serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: c3c38ffc10fb4d139099c551b3c21728
name: '{#DISK_LOCATION}: Disk size'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.13.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.physicaldisk.size[cucsStorageLocalDiskSize.{#SNMPINDEX}]'
delay: 1h
trends: '0'
units: B
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:size managed object property. In MB.
preprocessing:
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: disk
- tag: component
value: storage
- uuid: ad4616916d6644f480a2687dbc56a4a3
name: '{#DISK_LOCATION}: Physical disk status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.4.1.18.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}]'
delay: 3m
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalDisk:diskState managed object property.
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStoragePDriveStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: disk
- tag: component
value: storage
trigger_prototypes:
- uuid: ba92b99606fa4bf0bc4f1b6a362c2cdb
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.CRIT:"bad"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.CRIT:"predictiveFailure"}'
name: 'Cisco UCS Manager: {#DISK_LOCATION}: Physical disk error'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check physical disk for warnings or errors'
dependencies:
- name: 'Cisco UCS Manager: {#DISK_LOCATION}: Physical disk failed'
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"failed"}'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: eabf5aa62f004a2c996cc11bb5a6716a
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}])={$DISK.STATUS.FAIL:"failed"}'
name: 'Cisco UCS Manager: {#DISK_LOCATION}: Physical disk failed'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check physical disk for warnings or errors'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 8ac363db6f2346bba13b63f75cdabd22
name: 'PSU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#PSU_LOCATION},1.3.6.1.4.1.9.9.719.1.15.56.1.2]'
key: cisco.ucs.psu.discovery
delay: 1h
item_prototypes:
- uuid: 88a07d360c42431ba4ef31cbe825dc72
name: '{#PSU_LOCATION}: Power supply status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.15.56.1.7.{#SNMPINDEX}]'
key: 'cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}]'
delay: 3m
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
Cisco UCS equipment:Psu:operState managed object property
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: power
trigger_prototypes:
- uuid: 0d2713cf2b72472c8d8896880476c20e
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"inoperable"}'
name: 'Cisco UCS Manager: {#PSU_LOCATION}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 468f08407a7448a384e5dcde589cb9d0
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}])={$PSU.STATUS.WARN:"degraded"}'
name: 'Cisco UCS Manager: {#PSU_LOCATION}: Power supply is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors'
dependencies:
- name: 'Cisco UCS Manager: {#PSU_LOCATION}: Power supply is in critical state'
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}])={$PSU.STATUS.CRIT:"inoperable"}'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 90b24337c3304ff6a30428c7d46c26fd
name: 'Temperature CPU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SENSOR_LOCATION},1.3.6.1.4.1.9.9.719.1.41.2.1.2]'
key: cisco.ucs.temp.cpu.discovery
delay: 1h
item_prototypes:
- uuid: 7b822aeed3e24358aace9693e7f03385
name: '{#SENSOR_LOCATION}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.41.2.1.10.{#SNMPINDEX}]'
key: 'cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB
Cisco UCS processor:EnvStats:temperature managed object property
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: c3b3933ceb504207a87054a1f9773a76
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"CPU"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"CPU"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}: Temperature is above critical threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"CPU"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 13b393265f59431687b776297cb0b104
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"CPU"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"CPU"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}: Temperature is above warning threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"CPU"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
- name: 'Cisco UCS Manager: {#SENSOR_LOCATION}: Temperature is above critical threshold'
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"CPU"}'
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"CPU"}-3'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: b99a5c977c32418ea9efded6d507e3b5
name: 'Temperature discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SENSOR_LOCATION},1.3.6.1.4.1.9.9.719.1.9.44.1.2]'
key: cisco.ucs.temp.discovery
delay: 1h
item_prototypes:
- uuid: d57481cb764a429f928aa6de6837c4ae
name: '{#SENSOR_LOCATION}.IOH: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.44.1.13.{#SNMPINDEX}]'
key: 'cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnitMbTempStats:ioh1Temp managed object property
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: aa4bf1c8b942462dbd21ccf8bd8c4a6b
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 7751dd6bf1394daa9d918005d2d99d10
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.IOH: Temperature is above warning threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.IOH: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
- name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold'
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}'
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: d5e4b5b7e18c4545853c48db018dc127
name: '{#SENSOR_LOCATION}.Ambient: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.44.1.4.{#SNMPINDEX}]'
key: 'cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Temperature readings of testpoint: {#SENSOR_LOCATION}.Ambient
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 230958b560374a118857b77418c6ba11
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 4cdcddd04b0e4625893a1e20ce22a10f
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
- name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold'
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}'
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 9980042de8d74353bf4a386bb0f28d30
name: '{#SENSOR_LOCATION}.Front: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.44.1.8.{#SNMPINDEX}]'
key: 'cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnitMbTempStats:frontTemp managed object property
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 8ee1dfc360aa4aca84a03b452ead92ce
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Front: Temperature is above critical threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Front: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 196c9fe3facf4e3db348337714c77e17
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Front: Temperature is above warning threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Front: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
- name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Front: Temperature is above critical threshold'
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}'
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: e20bfa52f31f4a1a9f08ba02fe27f90c
name: '{#SENSOR_LOCATION}.Rear: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.44.1.21.{#SNMPINDEX}]'
key: 'cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnitMbTempStats:rearTemp managed object property
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: a8714fcba51c46f9aa84fa02fba37743
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold: >{$TEMP.MAX.CRIT:"Ambient"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 87068c693e574cd3952ca90e95a7a681
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.WARN:"Ambient"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.WARN:"Ambient"}-3'
name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Rear: Temperature is above warning threshold'
event_name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Rear: Temperature is above warning threshold: >{$TEMP.MAX.WARN:"Ambient"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
- name: 'Cisco UCS Manager: {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold'
expression: 'avg(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP.MAX.CRIT:"Ambient"}'
recovery_expression: 'max(/Cisco UCS Manager by SNMP/cisco.ucs.sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP.MAX.CRIT:"Ambient"}-3'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 9c5d5ce2f672487db83cf91f22c1a413
name: 'Unit discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#UNIT_LOCATION},1.3.6.1.4.1.9.9.719.1.9.35.1.2]'
key: cisco.ucs.unit.discovery
delay: 1h
item_prototypes:
- uuid: 41ecc1caac444d2587d51e33057e6d39
name: '{#UNIT_LOCATION}: Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.35.1.32.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.model[cucsComputeRackUnitModel.{#SNMPINDEX}]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnit:model managed object property
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: ac3217187db3453eb8b9932fce7c79c4
name: '{#UNIT_LOCATION}: Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.35.1.47.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnit:serial managed object property
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
trigger_prototypes:
- uuid: 27253665837647bb9c3be58f7d0881ae
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#1)<>last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#2) and length(last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]))>0'
name: 'Cisco UCS Manager: {#UNIT_LOCATION}: Device has been replaced'
event_name: 'Cisco UCS Manager: {#UNIT_LOCATION}: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: c6ebb7db809f4c62aae795a8b1c4b740
name: '{#UNIT_LOCATION}: Overall system health status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.9.35.1.42.{#SNMPINDEX}]'
key: 'cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}]'
delay: 30s
trends: '0'
description: |
MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
Cisco UCS compute:RackUnit:operState managed object property
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsLsOperState'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
trigger_prototypes:
- uuid: 7f7c337f4f9f44a3a176acce5bf27f29
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"computeFailed"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"configFailure"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"unconfigFailure"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"inoperable"}'
name: 'Cisco UCS Manager: {#UNIT_LOCATION}: System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for errors'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 15ee6a98f2af4da4bcaa95821ffff524
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"testFailed"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"thermalProblem"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"powerProblem"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"voltageProblem"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.WARN:"diagnosticsFailed"}'
name: 'Cisco UCS Manager: {#UNIT_LOCATION}: System status is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for warnings'
dependencies:
- name: 'Cisco UCS Manager: {#UNIT_LOCATION}: System status is in critical state'
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"computeFailed"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"configFailure"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"unconfigFailure"} or last(/Cisco UCS Manager by SNMP/cisco.ucs.status[cucsComputeRackUnitOperState.{#SNMPINDEX}])={$HEALTH.STATUS.CRIT:"inoperable"}'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 6d0760c4d29d4113b179b0e5c18f7e3b
name: 'Virtual disk discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#VDISK_LOCATION},1.3.6.1.4.1.9.9.719.1.45.8.1.2]'
key: cisco.ucs.virtualDisk.discovery
delay: 1h
description: 'CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalLunTable'
item_prototypes:
- uuid: c80f07f350bc472fb73282f5c80e16e3
name: '{#VDISK_LOCATION}: Layout type'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.8.1.14.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.virtualdisk.layout[cucsStorageLocalLunType.{#SNMPINDEX}]'
delay: 1h
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalLun:type managed object property
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: disk
- tag: component
value: storage
- uuid: 59a403629e8b40d981c2926ead601966
name: '{#VDISK_LOCATION}: Disk size'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.8.1.13.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.virtualdisk.size[cucsStorageLocalLunSize.{#SNMPINDEX}]'
delay: 1h
trends: '0'
units: B
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalLun:size managed object property in MB.
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType'
preprocessing:
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: disk
- tag: component
value: storage
- uuid: 39504e417781414081e1198adef562d4
name: '{#VDISK_LOCATION}: Status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.719.1.45.8.1.10.{#SNMPINDEX}]'
key: 'cisco.ucs.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB
Cisco UCS storage:LocalLun:presence managed object property
valuemap:
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentPresence'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: disk
- tag: component
value: storage
trigger_prototypes:
- uuid: 63232b4e1f6b411a93ff8abad1ff3200
expression: 'last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}])<>{$VDISK.STATUS.OK:"equipped"}'
name: 'Cisco UCS Manager: {#VDISK_LOCATION}: Virtual disk is not in OK state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check virtual disk for warnings or errors'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
tags:
- tag: class
value: hardware
- tag: target
value: cisco
- tag: target
value: cisco-ucs-manager
macros:
- macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
value: '2'
description: 'The cache battery critical state for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
value: '1'
description: 'The cache battery normal state for trigger expression.'
- macro: '{$DISK.ARRAY.STATUS.CRIT:"inoperable"}'
value: '2'
description: 'The array controller critical state for trigger expression.'
- macro: '{$DISK.ARRAY.STATUS.OK:"operable"}'
value: '1'
description: 'The array controller normal state for trigger expression.'
- macro: '{$DISK.ARRAY.STATUS.WARN:"degraded"}'
value: '3'
description: 'The array controller warning state for trigger expression.'
- macro: '{$DISK.STATUS.CRIT:"bad"}'
value: '16'
description: 'The disk critical state for trigger expression.'
- macro: '{$DISK.STATUS.CRIT:"predictiveFailure"}'
value: '11'
description: 'The disk critical state for trigger expression.'
- macro: '{$DISK.STATUS.FAIL:"failed"}'
value: '9'
description: 'The disk fail state for trigger expression.'
- macro: '{$FAN.STATUS.CRIT:"inoperable"}'
value: '2'
description: 'The critical value of the FAN sensor for trigger expression.'
- macro: '{$FAN.STATUS.WARN:"degraded"}'
value: '3'
description: 'The warning value of the FAN sensor for trigger expression.'
- macro: '{$HEALTH.STATUS.CRIT:"computeFailed"}'
value: '30'
description: 'The unit health critical state for trigger expression.'
- macro: '{$HEALTH.STATUS.CRIT:"configFailure"}'
value: '33'
description: 'The unit health critical state for trigger expression.'
- macro: '{$HEALTH.STATUS.CRIT:"inoperable"}'
value: '60'
description: 'The unit health critical state for trigger expression.'
- macro: '{$HEALTH.STATUS.CRIT:"unconfigFailure"}'
value: '34'
description: 'The unit health critical state for trigger expression.'
- macro: '{$HEALTH.STATUS.WARN:"diagnosticsFailed"}'
value: '204'
description: 'The unit health warning state for trigger expression.'
- macro: '{$HEALTH.STATUS.WARN:"powerProblem"}'
value: '62'
description: 'The unit health warning state for trigger expression.'
- macro: '{$HEALTH.STATUS.WARN:"testFailed"}'
value: '35'
description: 'The unit health warning state for trigger expression.'
- macro: '{$HEALTH.STATUS.WARN:"thermalProblem"}'
value: '60'
description: 'The unit health warning state for trigger expression.'
- macro: '{$HEALTH.STATUS.WARN:"voltageProblem"}'
value: '62'
description: 'The unit health warning state for trigger expression.'
- macro: '{$IF.ERRORS.WARN}'
value: '2'
- macro: '{$IFCONTROL}'
value: '1'
- macro: '{$NET.IFADMINSTATUS.MATCHES}'
value: '^.*'
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$NET.IFADMINSTATUS.NOT_MATCHES}'
value: ^2$
description: 'This macro is used in network interface discovery. Can be overridden on the host level. Ignore down(2) administrative status by default.'
- macro: '{$NET.IFALIAS.MATCHES}'
value: '.*'
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$NET.IFALIAS.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$NET.IFDESCR.MATCHES}'
value: '.*'
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$NET.IFDESCR.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$NET.IFNAME.MATCHES}'
value: '^.*$'
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$NET.IFNAME.NOT_MATCHES}'
value: '(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12}|sup-fc0)'
description: 'This macro is used in network interface discovery. Can be overridden on the host level. Filter out loopbacks, sup-fc0, nulls, docker veth links and docker0 bridge by default.'
- macro: '{$NET.IFOPERSTATUS.MATCHES}'
value: '^.*$'
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$NET.IFOPERSTATUS.NOT_MATCHES}'
value: ^6$
description: 'This macro is used in network interface discovery. Can be overridden on the host level. Ignore notPresent(6) by default.'
- macro: '{$NET.IFTYPE.MATCHES}'
value: '.*'
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$NET.IFTYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used in network interface discovery. Can be overridden on the host level.'
- macro: '{$PSU.STATUS.CRIT:"inoperable"}'
value: '2'
description: 'The critical value of the PSU sensor for trigger expression.'
- macro: '{$PSU.STATUS.WARN:"degraded"}'
value: '3'
description: 'The warning value of the PSU sensor for trigger expression.'
- macro: '{$SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for SNMP agent availability trigger expression.'
- macro: '{$TEMP.MAX.CRIT:"Ambient"}'
value: '35'
description: 'The temperature maximum critical value for trigger expression.'
- macro: '{$TEMP.MAX.WARN:"Ambient"}'
value: '30'
description: 'The temperature maximum warning value for trigger expression.'
- macro: '{$VDISK.STATUS.OK:"equipped"}'
value: '10'
description: 'The vdisk normal state for trigger expression.'
dashboards:
- uuid: b28e8cdadce64ba299c56054a18ea31d
name: 'Network interfaces'
pages:
- widgets:
- type: graphprototype
width: '72'
height: '5'
fields:
- type: INTEGER
name: columns
value: '1'
- type: GRAPH_PROTOTYPE
name: graphid.0
value:
host: 'Cisco UCS Manager by SNMP'
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
- type: STRING
name: reference
value: AAAAA
valuemaps:
- uuid: 8648df22d8be42359900e11ea395a98c
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentOperability'
mappings:
- value: '0'
newvalue: unknown
- value: '1'
newvalue: operable
- value: '2'
newvalue: inoperable
- value: '3'
newvalue: degraded
- value: '4'
newvalue: poweredOff
- value: '5'
newvalue: powerProblem
- value: '6'
newvalue: removed
- value: '7'
newvalue: voltageProblem
- value: '8'
newvalue: thermalProblem
- value: '9'
newvalue: performanceProblem
- value: '10'
newvalue: accessibilityProblem
- value: '11'
newvalue: identityUnestablishable
- value: '12'
newvalue: biosPostTimeout
- value: '13'
newvalue: disabled
- value: '14'
newvalue: malformedFru
- value: '15'
newvalue: backplanePortProblem
- value: '16'
newvalue: chassisIntrusion
- value: '51'
newvalue: fabricConnProblem
- value: '52'
newvalue: fabricUnsupportedConn
- value: '81'
newvalue: config
- value: '82'
newvalue: equipmentProblem
- value: '83'
newvalue: decommissioning
- value: '84'
newvalue: chassisLimitExceeded
- value: '100'
newvalue: notSupported
- value: '101'
newvalue: discovery
- value: '102'
newvalue: discoveryFailed
- value: '103'
newvalue: identify
- value: '104'
newvalue: postFailure
- value: '105'
newvalue: upgradeProblem
- value: '106'
newvalue: peerCommProblem
- value: '107'
newvalue: autoUpgrade
- value: '108'
newvalue: linkActivateBlocked
- uuid: 17dde900e96a47929b0abed0d5006c84
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsEquipmentPresence'
mappings:
- value: '0'
newvalue: unknown
- value: '1'
newvalue: empty
- value: '10'
newvalue: equipped
- value: '11'
newvalue: missing
- value: '12'
newvalue: mismatch
- value: '13'
newvalue: equippedNotPrimary
- value: '14'
newvalue: equippedSlave
- value: '15'
newvalue: mismatchSlave
- value: '16'
newvalue: missingSlave
- value: '20'
newvalue: equippedIdentityUnestablishable
- value: '21'
newvalue: mismatchIdentityUnestablishable
- value: '22'
newvalue: equippedWithMalformedFru
- value: '30'
newvalue: inaccessible
- value: '40'
newvalue: unauthorized
- value: '100'
newvalue: notSupported
- value: '101'
newvalue: equippedUnsupported
- value: '102'
newvalue: equippedDiscNotStarted
- value: '103'
newvalue: equippedDiscInProgress
- value: '104'
newvalue: equippedDiscError
- value: '105'
newvalue: equippedDiscUnknown
- uuid: c4a3603d4d8944ad8a8d2529bc3f1278
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsLsOperState'
mappings:
- value: '0'
newvalue: indeterminate
- value: '1'
newvalue: unassociated
- value: '10'
newvalue: ok
- value: '11'
newvalue: discovery
- value: '12'
newvalue: config
- value: '13'
newvalue: unconfig
- value: '14'
newvalue: powerOff
- value: '15'
newvalue: restart
- value: '20'
newvalue: maintenance
- value: '21'
newvalue: test
- value: '29'
newvalue: computeMismatch
- value: '30'
newvalue: computeFailed
- value: '31'
newvalue: degraded
- value: '32'
newvalue: discoveryFailed
- value: '33'
newvalue: configFailure
- value: '34'
newvalue: unconfigFailed
- value: '35'
newvalue: testFailed
- value: '36'
newvalue: maintenanceFailed
- value: '40'
newvalue: removed
- value: '41'
newvalue: disabled
- value: '50'
newvalue: inaccessible
- value: '60'
newvalue: thermalProblem
- value: '61'
newvalue: powerProblem
- value: '62'
newvalue: voltageProblem
- value: '63'
newvalue: inoperable
- value: '101'
newvalue: decommissioning
- value: '201'
newvalue: biosRestore
- value: '202'
newvalue: cmosReset
- value: '203'
newvalue: diagnostics
- value: '204'
newvalue: diagnosticsFailed
- value: '210'
newvalue: pendingReboot
- value: '211'
newvalue: pendingReassociation
- value: '212'
newvalue: svnicNotPresent
- uuid: 7d09a2b8df18410ca871ed9e7dbe6aa1
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageLunType'
mappings:
- value: '0'
newvalue: unspecified
- value: '1'
newvalue: simple
- value: '2'
newvalue: mirror
- value: '3'
newvalue: stripe
- value: '4'
newvalue: raid
- value: '5'
newvalue: stripeParity
- value: '6'
newvalue: stripeDualParity
- value: '7'
newvalue: mirrorStripe
- value: '8'
newvalue: stripeParityStripe
- value: '9'
newvalue: stripeDualParityStripe
- uuid: 70a906bfe3b447a39e5a0f0ba5210ae2
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStoragePDriveStatus'
mappings:
- value: '0'
newvalue: unknown
- value: '1'
newvalue: online
- value: '2'
newvalue: unconfiguredGood
- value: '3'
newvalue: globalHotSpare
- value: '4'
newvalue: dedicatedHotSpare
- value: '5'
newvalue: jbod
- value: '6'
newvalue: offline
- value: '7'
newvalue: rebuilding
- value: '8'
newvalue: copyback
- value: '9'
newvalue: failed
- value: '10'
newvalue: unconfiguredBad
- value: '11'
newvalue: predictiveFailure
- value: '12'
newvalue: disabledForRemoval
- value: '13'
newvalue: foreignConfiguration
- value: '14'
newvalue: zeroing
- value: '15'
newvalue: good
- value: '16'
newvalue: bad
- value: '17'
newvalue: lockedForeignConfiguration
- uuid: e1407fbe331343d3bda7d7eb122c085a
name: 'CISCO-UNIFIED-COMPUTING-TC-MIB::CucsStorageTechnology'
mappings:
- value: '0'
newvalue: unspecified
- value: '1'
newvalue: hdd
- value: '2'
newvalue: ssd
- value: '3'
newvalue: nvme
- uuid: 2b0fde08268f4ce7b47aae3827ebdf23
name: 'IF-MIB::ifOperStatus'
mappings:
- value: '1'
newvalue: up
- value: '2'
newvalue: down
- value: '3'
newvalue: testing
- value: '4'
newvalue: unknown
- value: '5'
newvalue: dormant
- value: '6'
newvalue: notPresent
- value: '7'
newvalue: lowerLayerDown
- uuid: be402fda36e64dd2ad807925755735c4
name: 'IF-MIB::ifType'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: regular1822
- value: '3'
newvalue: hdh1822
- value: '4'
newvalue: ddnX25
- value: '5'
newvalue: rfc877x25
- value: '6'
newvalue: ethernetCsmacd
- value: '7'
newvalue: iso88023Csmacd
- value: '8'
newvalue: iso88024TokenBus
- value: '9'
newvalue: iso88025TokenRing
- value: '10'
newvalue: iso88026Man
- value: '11'
newvalue: starLan
- value: '12'
newvalue: proteon10Mbit
- value: '13'
newvalue: proteon80Mbit
- value: '14'
newvalue: hyperchannel
- value: '15'
newvalue: fddi
- value: '16'
newvalue: lapb
- value: '17'
newvalue: sdlc
- value: '18'
newvalue: ds1
- value: '19'
newvalue: e1
- value: '20'
newvalue: basicISDN
- value: '21'
newvalue: primaryISDN
- value: '22'
newvalue: propPointToPointSerial
- value: '23'
newvalue: ppp
- value: '24'
newvalue: softwareLoopback
- value: '25'
newvalue: eon
- value: '26'
newvalue: ethernet3Mbit
- value: '27'
newvalue: nsip
- value: '28'
newvalue: slip
- value: '29'
newvalue: ultra
- value: '30'
newvalue: ds3
- value: '31'
newvalue: sip
- value: '32'
newvalue: frameRelay
- value: '33'
newvalue: rs232
- value: '34'
newvalue: para
- value: '35'
newvalue: arcnet
- value: '36'
newvalue: arcnetPlus
- value: '37'
newvalue: atm
- value: '38'
newvalue: miox25
- value: '39'
newvalue: sonet
- value: '40'
newvalue: x25ple
- value: '41'
newvalue: iso88022llc
- value: '42'
newvalue: localTalk
- value: '43'
newvalue: smdsDxi
- value: '44'
newvalue: frameRelayService
- value: '45'
newvalue: v35
- value: '46'
newvalue: hssi
- value: '47'
newvalue: hippi
- value: '48'
newvalue: modem
- value: '49'
newvalue: aal5
- value: '50'
newvalue: sonetPath
- value: '51'
newvalue: sonetVT
- value: '52'
newvalue: smdsIcip
- value: '53'
newvalue: propVirtual
- value: '54'
newvalue: propMultiplexor
- value: '55'
newvalue: ieee80212
- value: '56'
newvalue: fibreChannel
- value: '57'
newvalue: hippiInterface
- value: '58'
newvalue: frameRelayInterconnect
- value: '59'
newvalue: aflane8023
- value: '60'
newvalue: aflane8025
- value: '61'
newvalue: cctEmul
- value: '62'
newvalue: fastEther
- value: '63'
newvalue: isdn
- value: '64'
newvalue: v11
- value: '65'
newvalue: v36
- value: '66'
newvalue: g703at64k
- value: '67'
newvalue: g703at2mb
- value: '68'
newvalue: qllc
- value: '69'
newvalue: fastEtherFX
- value: '70'
newvalue: channel
- value: '71'
newvalue: ieee80211
- value: '72'
newvalue: ibm370parChan
- value: '73'
newvalue: escon
- value: '74'
newvalue: dlsw
- value: '75'
newvalue: isdns
- value: '76'
newvalue: isdnu
- value: '77'
newvalue: lapd
- value: '78'
newvalue: ipSwitch
- value: '79'
newvalue: rsrb
- value: '80'
newvalue: atmLogical
- value: '81'
newvalue: ds0
- value: '82'
newvalue: ds0Bundle
- value: '83'
newvalue: bsc
- value: '84'
newvalue: async
- value: '85'
newvalue: cnr
- value: '86'
newvalue: iso88025Dtr
- value: '87'
newvalue: eplrs
- value: '88'
newvalue: arap
- value: '89'
newvalue: propCnls
- value: '90'
newvalue: hostPad
- value: '91'
newvalue: termPad
- value: '92'
newvalue: frameRelayMPI
- value: '93'
newvalue: x213
- value: '94'
newvalue: adsl
- value: '95'
newvalue: radsl
- value: '96'
newvalue: sdsl
- value: '97'
newvalue: vdsl
- value: '98'
newvalue: iso88025CRFPInt
- value: '99'
newvalue: myrinet
- value: '100'
newvalue: voiceEM
- value: '101'
newvalue: voiceFXO
- value: '102'
newvalue: voiceFXS
- value: '103'
newvalue: voiceEncap
- value: '104'
newvalue: voiceOverIp
- value: '105'
newvalue: atmDxi
- value: '106'
newvalue: atmFuni
- value: '107'
newvalue: atmIma
- value: '108'
newvalue: pppMultilinkBundle
- value: '109'
newvalue: ipOverCdlc
- value: '110'
newvalue: ipOverClaw
- value: '111'
newvalue: stackToStack
- value: '112'
newvalue: virtualIpAddress
- value: '113'
newvalue: mpc
- value: '114'
newvalue: ipOverAtm
- value: '115'
newvalue: iso88025Fiber
- value: '116'
newvalue: tdlc
- value: '117'
newvalue: gigabitEthernet
- value: '118'
newvalue: hdlc
- value: '119'
newvalue: lapf
- value: '120'
newvalue: v37
- value: '121'
newvalue: x25mlp
- value: '122'
newvalue: x25huntGroup
- value: '123'
newvalue: trasnpHdlc
- value: '124'
newvalue: interleave
- value: '125'
newvalue: fast
- value: '126'
newvalue: ip
- value: '127'
newvalue: docsCableMaclayer
- value: '128'
newvalue: docsCableDownstream
- value: '129'
newvalue: docsCableUpstream
- value: '130'
newvalue: a12MppSwitch
- value: '131'
newvalue: tunnel
- value: '132'
newvalue: coffee
- value: '133'
newvalue: ces
- value: '134'
newvalue: atmSubInterface
- value: '135'
newvalue: l2vlan
- value: '136'
newvalue: l3ipvlan
- value: '137'
newvalue: l3ipxvlan
- value: '138'
newvalue: digitalPowerline
- value: '139'
newvalue: mediaMailOverIp
- value: '140'
newvalue: dtm
- value: '141'
newvalue: dcn
- value: '142'
newvalue: ipForward
- value: '143'
newvalue: msdsl
- value: '144'
newvalue: ieee1394
- value: '145'
newvalue: if-gsn
- value: '146'
newvalue: dvbRccMacLayer
- value: '147'
newvalue: dvbRccDownstream
- value: '148'
newvalue: dvbRccUpstream
- value: '149'
newvalue: atmVirtual
- value: '150'
newvalue: mplsTunnel
- value: '151'
newvalue: srp
- value: '152'
newvalue: voiceOverAtm
- value: '153'
newvalue: voiceOverFrameRelay
- value: '154'
newvalue: idsl
- value: '155'
newvalue: compositeLink
- value: '156'
newvalue: ss7SigLink
- value: '157'
newvalue: propWirelessP2P
- value: '158'
newvalue: frForward
- value: '159'
newvalue: rfc1483
- value: '160'
newvalue: usb
- value: '161'
newvalue: ieee8023adLag
- value: '162'
newvalue: bgppolicyaccounting
- value: '163'
newvalue: frf16MfrBundle
- value: '164'
newvalue: h323Gatekeeper
- value: '165'
newvalue: h323Proxy
- value: '166'
newvalue: mpls
- value: '167'
newvalue: mfSigLink
- value: '168'
newvalue: hdsl2
- value: '169'
newvalue: shdsl
- value: '170'
newvalue: ds1FDL
- value: '171'
newvalue: pos
- value: '172'
newvalue: dvbAsiIn
- value: '173'
newvalue: dvbAsiOut
- value: '174'
newvalue: plc
- value: '175'
newvalue: nfas
- value: '176'
newvalue: tr008
- value: '177'
newvalue: gr303RDT
- value: '178'
newvalue: gr303IDT
- value: '179'
newvalue: isup
- value: '180'
newvalue: propDocsWirelessMaclayer
- value: '181'
newvalue: propDocsWirelessDownstream
- value: '182'
newvalue: propDocsWirelessUpstream
- value: '183'
newvalue: hiperlan2
- value: '184'
newvalue: propBWAp2Mp
- value: '185'
newvalue: sonetOverheadChannel
- value: '186'
newvalue: digitalWrapperOverheadChannel
- value: '187'
newvalue: aal2
- value: '188'
newvalue: radioMAC
- value: '189'
newvalue: atmRadio
- value: '190'
newvalue: imt
- value: '191'
newvalue: mvl
- value: '192'
newvalue: reachDSL
- value: '193'
newvalue: frDlciEndPt
- value: '194'
newvalue: atmVciEndPt
- value: '195'
newvalue: opticalChannel
- value: '196'
newvalue: opticalTransport
- value: '197'
newvalue: propAtm
- value: '198'
newvalue: voiceOverCable
- value: '199'
newvalue: infiniband
- value: '200'
newvalue: teLink
- value: '201'
newvalue: q2931
- value: '202'
newvalue: virtualTg
- value: '203'
newvalue: sipTg
- value: '204'
newvalue: sipSig
- value: '205'
newvalue: docsCableUpstreamChannel
- value: '206'
newvalue: econet
- value: '207'
newvalue: pon155
- value: '208'
newvalue: pon622
- value: '209'
newvalue: bridge
- value: '210'
newvalue: linegroup
- value: '211'
newvalue: voiceEMFGD
- value: '212'
newvalue: voiceFGDEANA
- value: '213'
newvalue: voiceDID
- value: '214'
newvalue: mpegTransport
- value: '215'
newvalue: sixToFour
- value: '216'
newvalue: gtp
- value: '217'
newvalue: pdnEtherLoop1
- value: '218'
newvalue: pdnEtherLoop2
- value: '219'
newvalue: opticalChannelGroup
- value: '220'
newvalue: homepna
- value: '221'
newvalue: gfp
- value: '222'
newvalue: ciscoISLvlan
- value: '223'
newvalue: actelisMetaLOOP
- value: '224'
newvalue: fcipLink
- value: '225'
newvalue: rpr
- value: '226'
newvalue: qam
- value: '227'
newvalue: lmp
- value: '228'
newvalue: cblVectaStar
- value: '229'
newvalue: docsCableMCmtsDownstream
- value: '230'
newvalue: adsl2
- value: '231'
newvalue: macSecControlledIF
- value: '232'
newvalue: macSecUncontrolledIF
- value: '233'
newvalue: aviciOpticalEther
- value: '234'
newvalue: atmbond
- value: '235'
newvalue: voiceFGDOS
- value: '236'
newvalue: mocaVersion1
- value: '237'
newvalue: ieee80216WMAN
- value: '238'
newvalue: adsl2plus
- value: '239'
newvalue: dvbRcsMacLayer
- value: '240'
newvalue: dvbTdm
- value: '241'
newvalue: dvbRcsTdma
- value: '242'
newvalue: x86Laps
- value: '243'
newvalue: wwanPP
- value: '244'
newvalue: wwanPP2
- value: '245'
newvalue: voiceEBS
- value: '246'
newvalue: ifPwType
- value: '247'
newvalue: ilan
- value: '248'
newvalue: pip
- value: '249'
newvalue: aluELP
- value: '250'
newvalue: gpon
- value: '251'
newvalue: vdsl2
- value: '252'
newvalue: capwapDot11Profile
- value: '253'
newvalue: capwapDot11Bss
- value: '254'
newvalue: capwapWtpVirtualRadio
- value: '255'
newvalue: bits
- value: '256'
newvalue: docsCableUpstreamRfPort
- value: '257'
newvalue: cableDownstreamRfPort
- value: '258'
newvalue: vmwareVirtualNic
- value: '259'
newvalue: ieee802154
- value: '260'
newvalue: otnOdu
- value: '261'
newvalue: otnOtu
- value: '262'
newvalue: ifVfiType
- value: '263'
newvalue: g9981
- value: '264'
newvalue: g9982
- value: '265'
newvalue: g9983
- value: '266'
newvalue: aluEpon
- value: '267'
newvalue: aluEponOnu
- value: '268'
newvalue: aluEponPhysicalUni
- value: '269'
newvalue: aluEponLogicalLink
- value: '270'
newvalue: aluGponOnu
- value: '271'
newvalue: aluGponPhysicalUni
- value: '272'
newvalue: vmwareNicTeam
- value: '277'
newvalue: docsOfdmDownstream
- value: '278'
newvalue: docsOfdmaUpstream
- value: '279'
newvalue: gfast
- value: '280'
newvalue: sdci
- value: '281'
newvalue: xboxWireless
- value: '282'
newvalue: fastdsl
- value: '283'
newvalue: docsCableScte55d1FwdOob
- value: '284'
newvalue: docsCableScte55d1RetOob
- value: '285'
newvalue: docsCableScte55d2DsOob
- value: '286'
newvalue: docsCableScte55d2UsOob
- value: '287'
newvalue: docsCableNdf
- value: '288'
newvalue: docsCableNdr
- value: '289'
newvalue: ptm
- value: '290'
newvalue: ghn
- uuid: 9ea529bf28a84fae95f1506ca6ca37b8
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 9026e680b409424e8fa29934878cb771
expression: '(last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco UCS Manager by SNMP/cisco.ucs.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco UCS Manager by SNMP/cisco.ucs.net.uptime[sysUpTime.0])<10m)'
name: 'Cisco UCS Manager: Host has been restarted'
event_name: 'Cisco UCS Manager: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
- name: 'Cisco UCS Manager: No SNMP data collection'
expression: 'max(/Cisco UCS Manager by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
tags:
- tag: scope
value: notice