Files
templates-default/Cisco_Catalyst_3750V2-24TS_by_SNMP.yaml

1991 lines
87 KiB
YAML

zabbix_export:
version: '7.0'
template_groups:
- uuid: 36bff6c29af64692839d077febfc7079
name: 'Templates/Network devices'
templates:
- uuid: 30d084c6b7844b7cab6cf820b00bb7b2
template: 'Cisco Catalyst 3750V2-24TS by SNMP'
name: 'Cisco Catalyst 3750V2-24TS by SNMP'
description: |
Template Cisco Catalyst 3750V2-24TS
MIBs used:
CISCO-MEMORY-POOL-MIB
IF-MIB
EtherLike-MIB
SNMPv2-MIB
CISCO-PROCESS-MIB
CISCO-ENVMON-MIB
ENTITY-MIB
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/418396-discussion-thread-for-official-zabbix-templates-for-cisco
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-4
groups:
- name: 'Templates/Network devices'
items:
- uuid: 872058629f19424995e696d1354fbe01
name: 'ICMP ping'
type: SIMPLE
key: icmpping
valuemap:
name: 'Service state'
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: e536d08729024bbcbe51f63ac1074796
expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/icmpping,#3)=0'
name: 'Cisco Catalyst 3750V2-24TS: Unavailable by ICMP ping'
priority: HIGH
description: 'Last three attempts returned timeout. Please check device connectivity.'
tags:
- tag: scope
value: availability
- uuid: 56b5f81de3c34f2aa9acd399dd212d62
name: 'ICMP loss'
type: SIMPLE
key: icmppingloss
value_type: FLOAT
units: '%'
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: 63bdfa05fcbe455db4dbb28ae333292a
expression: 'min(/Cisco Catalyst 3750V2-24TS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-24TS by SNMP/icmppingloss,5m)<100'
name: 'Cisco Catalyst 3750V2-24TS: High ICMP ping loss'
opdata: 'Loss: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: Unavailable by ICMP ping'
expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/icmpping,#3)=0'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: d34fc050448e4c48b303bf8c75c50060
name: 'ICMP response time'
type: SIMPLE
key: icmppingsec
value_type: FLOAT
units: s
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: 79b80f4faa30401c8aa260a7bc961f9c
expression: 'avg(/Cisco Catalyst 3750V2-24TS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
name: 'Cisco Catalyst 3750V2-24TS: High ICMP ping response time'
opdata: 'Value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: High ICMP ping loss'
expression: 'min(/Cisco Catalyst 3750V2-24TS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-24TS by SNMP/icmppingloss,5m)<100'
- name: 'Cisco Catalyst 3750V2-24TS: Unavailable by ICMP ping'
expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/icmpping,#3)=0'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: c7a43b6281384161b6e1f28840d55aa1
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'Item is used to collect all SNMP traps unmatched by other snmptrap items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: system
- uuid: 7f563d184760420080849d161bf373f6
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: system.contact
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 74af4fbc07284c9eb9d4a913fd5e7b2b
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: system.descr
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should
include the full name and version identification of the system's hardware type, software operating-system, and
networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: a7cf2f68a1c842e081deec4a16410071
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.13.1]'
key: system.hw.model
delay: 1h
value_type: CHAR
trends: '0'
description: 'MIB: ENTITY-MIB'
inventory_link: MODEL
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 6d9b2e70dd61424f8f0ffebf89d20853
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.11.1]'
key: system.hw.serialnumber
delay: 1h
value_type: CHAR
trends: '0'
description: 'MIB: ENTITY-MIB'
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: be325325a6bd4cf4ae1312b4488af80d
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.serialnumber,#1)<>last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.serialnumber,#2) and length(last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.serialnumber))>0'
name: 'Cisco Catalyst 3750V2-24TS: Device has been replaced'
event_name: 'Cisco Catalyst 3750V2-24TS: Device has been replaced (new serial number received)'
priority: INFO
description: 'The device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 6fd05b29760a4b10bf9b1125e8747cd1
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]'
key: system.hw.uptime
trends: '0'
units: uptime
description: |
MIB: HOST-RESOURCES-MIB
The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
preprocessing:
- type: CHECK_NOT_SUPPORTED
parameters:
- '-1'
error_handler: CUSTOM_VALUE
error_handler_params: '0'
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: cc4aa80bbd2d49f9bca23b305399f0fa
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: system.location
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: system
- uuid: 726fa93646ad429789dcec2fbfabc6ff
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: system.name
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: system
triggers:
- uuid: d19bce317a4b4ab19485a183d446dcc7
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-24TS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-24TS by SNMP/system.name))>0'
name: 'Cisco Catalyst 3750V2-24TS: System name has changed'
event_name: 'Cisco Catalyst 3750V2-24TS: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: ecc18617c57a44bb96a565f450d569ac
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.3.0]'
key: system.net.uptime
trends: '0'
units: uptime
description: |
MIB: SNMPv2-MIB
The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
preprocessing:
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: 5e7cd491cf664de0b5046cd011186a0e
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: system.objectid
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: system
- uuid: 89971d6753ce4d98b68a70bf26f4b99e
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: system.sw.os
delay: 1h
value_type: CHAR
trends: '0'
description: 'MIB: SNMPv2-MIB'
inventory_link: OS
preprocessing:
- type: REGEX
parameters:
- 'Version (.+), RELEASE'
- \1
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: c139de21caf94d4b9c2d60977d4756f7
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/system.sw.os,#1)<>last(/Cisco Catalyst 3750V2-24TS by SNMP/system.sw.os,#2) and length(last(/Cisco Catalyst 3750V2-24TS by SNMP/system.sw.os))>0'
recovery_mode: NONE
name: 'Cisco Catalyst 3750V2-24TS: Operating system description has changed'
priority: INFO
description: 'The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually.'
manual_close: 'YES'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: System name has changed'
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-24TS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-24TS by SNMP/system.name))>0'
tags:
- tag: scope
value: notice
- uuid: 0951ddc53a2847b8ba816a5e4de9da2f
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: system
triggers:
- uuid: d78318493148438abca20fed768d4ced
expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
name: 'Cisco Catalyst 3750V2-24TS: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: a525aec08c6945fda4cad224232825a9
name: 'CPU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.109.1.1.1.1.5]'
key: cpu.discovery
delay: 1h
description: |
If your IOS device has several CPUs, you must use CISCO-PROCESS-MIB and its object cpmCPUTotal5minRev from the table called cpmCPUTotalTable ,
indexed with cpmCPUTotalIndex .
This table allows CISCO-PROCESS-MIB to keep CPU statistics for different physical entities in the router,
like different CPU chips, group of CPUs, or CPUs in different modules/cards.
In case of a single CPU, cpmCPUTotalTable has only one entry.
item_prototypes:
- uuid: a912b6f023a64087a99827f9c3cd8ceb
name: '#{#SNMPINDEX}: CPU utilization'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.109.1.1.1.1.8.{#SNMPINDEX}]'
key: 'system.cpu.util[{#SNMPINDEX}]'
delay: 5m
value_type: FLOAT
units: '%'
description: |
MIB: CISCO-PROCESS-MIB
Object name: cpmCPUTotal5minRev
The cpmCPUTotal5minRev MIB object provides a more accurate view of the performance of the router over time than the MIB objects cpmCPUTotal1minRev and cpmCPUTotal5secRev . These MIB objects are not accurate because they look at CPU at one minute and five second intervals, respectively. These MIBs enable you to monitor the trends and plan the capacity of your network. The recommended baseline rising threshold for cpmCPUTotal5minRev is 90 percent. Depending on the platform, some routers that run at 90 percent, for example, 2500s, can exhibit performance degradation versus a high-end router, for example, the 7500 series, which can operate fine.
Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15215-collect-cpu-util-snmp.html
tags:
- tag: component
value: cpu
- tag: cpu-index
value: '{#SNMPINDEX}'
trigger_prototypes:
- uuid: 6f039b9bfb00495ebe5e5eba56d25099
expression: 'min(/Cisco Catalyst 3750V2-24TS by SNMP/system.cpu.util[{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
name: 'Cisco Catalyst 3750V2-24TS: #{#SNMPINDEX}: High CPU utilization'
event_name: 'Cisco Catalyst 3750V2-24TS: #{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'The CPU utilization is too high. The system might be slow to respond.'
tags:
- tag: scope
value: capacity
- tag: scope
value: performance
graph_prototypes:
- uuid: e032e542ed064edc8a5b5a297a0f4839
name: '#{#SNMPINDEX}: CPU utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
- drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
key: 'system.cpu.util[{#SNMPINDEX}]'
- uuid: 777db6085eed46dbaef83c05049a8d4b
name: 'Entity Serial Numbers discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#ENT_CLASS},1.3.6.1.2.1.47.1.1.1.1.5,{#ENT_NAME},1.3.6.1.2.1.47.1.1.1.1.7,{#ENT_SN},1.3.6.1.2.1.47.1.1.1.1.11]'
key: entity_sn.discovery
delay: 1h
filter:
evaltype: AND
conditions:
- macro: '{#ENT_CLASS}'
value: '[^3]'
formulaid: A
- macro: '{#ENT_SN}'
value: .+
formulaid: B
item_prototypes:
- uuid: a7b5453459d24368943dd3394fca3d8f
name: '{#ENT_NAME}: Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.11.{#SNMPINDEX}]'
key: 'system.hw.serialnumber[{#SNMPINDEX}]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: ENTITY-MIB
Object name: entPhysicalSerialNum
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: serial-number
- tag: entity
value: '{#ENT_NAME}'
trigger_prototypes:
- uuid: 3e621db566ef4b5da2a3b0f5ee65ae81
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#1)<>last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#2) and length(last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}]))>0'
name: 'Cisco Catalyst 3750V2-24TS: {#ENT_NAME}: Device has been replaced'
event_name: 'Cisco Catalyst 3750V2-24TS: {#ENT_NAME}: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
tags:
- tag: scope
value: notice
- uuid: c204b466541d475c959d2613a848f03a
name: 'FAN discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.4.1.2]'
key: fan.discovery
delay: 1h
description: 'The table of fan status maintained by the environmental monitor.'
item_prototypes:
- uuid: 889b225dd7a84e4a9bce92d7138a6615
name: '{#SNMPVALUE}: Fan status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.4.1.3.{#SNMPINDEX}]'
key: 'sensor.fan.status[{#SNMPINDEX}]'
description: |
MIB: CISCO-ENVMON-MIB
Object name: ciscoEnvMonFanState
valuemap:
name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
tags:
- tag: component
value: fan
- tag: fan
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: f299241a1a3c4fde965b3a2b6a3b31d6
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: a4021a6d44fb439fa04b160b7cea2bca
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=2'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Fan is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Fan is in critical state'
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: bcde2f961af64c0eb27ec663577c60e1
name: 'Memory discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.48.1.1.1.2]'
key: memory.discovery
delay: 1h
description: |
Discovery of ciscoMemoryPoolTable, a table of memory pool monitoring entries.
http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
item_prototypes:
- uuid: 3c9040a8de7048baaa169b35f596a145
name: '{#SNMPVALUE}: Free memory'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.48.1.1.1.6.{#SNMPINDEX}]'
key: 'vm.memory.free[{#SNMPINDEX}]'
units: B
description: |
MIB: CISCO-MEMORY-POOL-MIB
Object name: ciscoMemoryPoolFree
Indicates the number of bytes from the memory pool that are currently unused on the managed device. Note that the sum of ciscoMemoryPoolUsed and ciscoMemoryPoolFree is the total amount of memory in the pool
Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
tags:
- tag: component
value: memory
- tag: memory
value: '{#SNMPVALUE}'
- uuid: e48d2527e378472ab060592a6b303484
name: '{#SNMPVALUE}: Used memory'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.48.1.1.1.5.{#SNMPINDEX}]'
key: 'vm.memory.used[{#SNMPINDEX}]'
units: B
description: |
MIB: CISCO-MEMORY-POOL-MIB
Object name: ciscoMemoryPoolUsed
Indicates the number of bytes from the memory pool that are currently in use by applications on the managed device.
Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
tags:
- tag: component
value: memory
- tag: memory
value: '{#SNMPVALUE}'
- uuid: c4b89f27f4534408a7fbe72110ce86de
name: '{#SNMPVALUE}: Memory utilization'
type: CALCULATED
key: 'vm.memory.util[{#SNMPINDEX}]'
value_type: FLOAT
units: '%'
params: 'last(//vm.memory.used[{#SNMPINDEX}])/(last(//vm.memory.free[{#SNMPINDEX}])+last(//vm.memory.used[{#SNMPINDEX}]))*100'
description: 'Memory utilization in %'
tags:
- tag: component
value: memory
- tag: memory
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: a88d7a734efc40868d3fbeda307c4e1f
expression: 'min(/Cisco Catalyst 3750V2-24TS by SNMP/vm.memory.util[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: High memory utilization'
event_name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: High memory utilization ( >{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
description: 'The system is running out of free memory.'
tags:
- tag: scope
value: capacity
- tag: scope
value: performance
graph_prototypes:
- uuid: 25de5d0bebc34c5d9bdf8e181c53588c
name: '{#SNMPVALUE}: Memory utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
- drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
key: 'vm.memory.util[{#SNMPINDEX}]'
- uuid: ce14cdd4669c4e8bb7b2badbe071f2d9
name: 'Network interfaces discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]'
key: net.if.discovery
delay: 1h
filter:
evaltype: AND
conditions:
- macro: '{#IFADMINSTATUS}'
value: '{$NET.IF.IFADMINSTATUS.MATCHES}'
formulaid: A
- macro: '{#IFADMINSTATUS}'
value: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#IFALIAS}'
value: '{$NET.IF.IFALIAS.MATCHES}'
formulaid: C
- macro: '{#IFALIAS}'
value: '{$NET.IF.IFALIAS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
- macro: '{#IFDESCR}'
value: '{$NET.IF.IFDESCR.MATCHES}'
formulaid: E
- macro: '{#IFDESCR}'
value: '{$NET.IF.IFDESCR.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: F
- macro: '{#IFNAME}'
value: '{$NET.IF.IFNAME.MATCHES}'
formulaid: G
- macro: '{#IFNAME}'
value: '{$NET.IF.IFNAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: H
- macro: '{#IFOPERSTATUS}'
value: '{$NET.IF.IFOPERSTATUS.MATCHES}'
formulaid: I
- macro: '{#IFOPERSTATUS}'
value: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: J
- macro: '{#IFTYPE}'
value: '{$NET.IF.IFTYPE.MATCHES}'
formulaid: K
- macro: '{#IFTYPE}'
value: '{$NET.IF.IFTYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: L
description: 'Discovering interfaces from IF-MIB.'
item_prototypes:
- uuid: c8d390c0ef1544a08d6a6974d49f17ad
name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}]'
key: 'net.if.in.discards[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
The number of inbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 02a607faaaf0494097e25a81d850d646
name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}]'
key: 'net.if.in.errors[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: a5f11bbeceb9418f86b1130ccb6942ec
expression: 'min(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8'
name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): High input error rate'
event_name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): High input error rate ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors in: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: performance
- uuid: 8b26f84549f14a91935b85b133e8b85b
name: 'Interface {#IFNAME}({#IFALIAS}): Bits received'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}]'
key: 'net.if.in[{#SNMPINDEX}]'
units: bps
description: |
MIB: IF-MIB
The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
- type: MULTIPLIER
parameters:
- '8'
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 6afb99d2489a4e4fa6ed329d3b140e99
name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}]'
key: 'net.if.out.discards[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
The number of outbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: b58d6657f5e14788829ff03f04bd1ac9
name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}]'
key: 'net.if.out.errors[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: 5182e3b82c044374a6f14f9a06fa0f24
expression: 'min(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8'
name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): High output error rate'
event_name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): High output error rate ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors out: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: performance
- uuid: fc23b72b6e0c4b0a9d5c9828f25cc43b
name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}]'
key: 'net.if.out[{#SNMPINDEX}]'
units: bps
description: |
MIB: IF-MIB
The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
- type: MULTIPLIER
parameters:
- '8'
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: a69f1d2e284a4d468d7226a68560405f
name: 'Interface {#IFNAME}({#IFALIAS}): Speed'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}]'
key: 'net.if.speed[{#SNMPINDEX}]'
units: bps
description: |
MIB: IF-MIB
An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.
preprocessing:
- type: MULTIPLIER
parameters:
- '1000000'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 9a2539d5137645cc868d80c6543b2a32
name: 'Interface {#IFNAME}({#IFALIAS}): Operational status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}]'
key: 'net.if.status[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
The current operational state of the interface.
- The testing(3) state indicates that no operational packet scan be passed
- If ifAdminStatus is down(2) then ifOperStatus should be down(2)
- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic
- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)
- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state
- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.
valuemap:
name: 'IF-MIB::ifOperStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: cb577e04f0a94508a10656c5f276d4e0
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): Link down'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is down.
2. `{ $IFCONTROL:"{#IFNAME}" }=1` - a user can redefine context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.
tags:
- tag: scope
value: availability
- uuid: f286f2bafa3e4d17a74842fff0a86dcf
name: 'Interface {#IFNAME}({#IFALIAS}): Interface type'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}]'
key: 'net.if.type[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
The type of interface.
Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA),
through updating the syntax of the IANAifType textual convention.
valuemap:
name: 'IF-MIB::ifType'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: 46d96d2815a04b32b00ed4ef6104fedc
expression: |
change(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])<0 and last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])>0
and (
last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.type[{#SNMPINDEX}])=6 or
last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.type[{#SNMPINDEX}])=7 or
last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.type[{#SNMPINDEX}])=11 or
last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.type[{#SNMPINDEX}])=62 or
last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.type[{#SNMPINDEX}])=69 or
last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.type[{#SNMPINDEX}])=117
)
and
(last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.status[{#SNMPINDEX}])<>2)
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
(change(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 and last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}],#2)>0) or
(last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.status[{#SNMPINDEX}])=2)
name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before'
opdata: 'Current reported speed: {ITEM.LASTVALUE1}'
priority: INFO
description: 'This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: notice
- uuid: 5af679006aaa40acbe01987ab15088ae
expression: |
(avg(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.in[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])) and
last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])>0
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'avg(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.in[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])'
name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage'
event_name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage ( > {$IF.UTIL.MAX:"{#IFNAME}"}% )'
opdata: 'In: {ITEM.LASTVALUE1}, speed: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'The utilization of the network interface is close to its estimated maximum bandwidth.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: performance
- uuid: e0b4ab67e80a4dbdb3d60246b8830228
expression: |
(avg(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.out[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])) and
last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])>0
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'avg(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.out[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.speed[{#SNMPINDEX}])'
name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage'
event_name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage ( > {$IF.UTIL.MAX:"{#IFNAME}"}% )'
opdata: 'Out: {ITEM.LASTVALUE1}, speed: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'The utilization of the network interface is close to its estimated maximum bandwidth.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: performance
graph_prototypes:
- uuid: 6be27bc4e258470bb324ef8f90295e92
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
graph_items:
- drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
key: 'net.if.in[{#SNMPINDEX}]'
- sortorder: '1'
drawtype: BOLD_LINE
color: 2774A4
item:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
key: 'net.if.out[{#SNMPINDEX}]'
- sortorder: '2'
color: F63100
yaxisside: RIGHT
item:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
key: 'net.if.out.errors[{#SNMPINDEX}]'
- sortorder: '3'
color: A54F10
yaxisside: RIGHT
item:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
key: 'net.if.in.errors[{#SNMPINDEX}]'
- sortorder: '4'
color: FC6EA3
yaxisside: RIGHT
item:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
key: 'net.if.out.discards[{#SNMPINDEX}]'
- sortorder: '5'
color: 6C59DC
yaxisside: RIGHT
item:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
key: 'net.if.in.discards[{#SNMPINDEX}]'
- uuid: d1264fbbd4b547a6874152179ed756d5
name: 'EtherLike discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.2.1.10.7.2.1.19,{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2]'
key: net.if.duplex.discovery
delay: 1h
filter:
evaltype: AND
conditions:
- macro: '{#IFOPERSTATUS}'
value: '1'
formulaid: A
- macro: '{#SNMPVALUE}'
value: (2|3)
formulaid: B
description: 'Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered.'
item_prototypes:
- uuid: ab70998b12124fee93168b5e8222512e
name: 'Interface {#IFNAME}({#IFALIAS}): Duplex status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.10.7.2.1.19.{#SNMPINDEX}]'
key: 'net.if.duplex[{#SNMPINDEX}]'
description: |
MIB: EtherLike-MIB
Object name: dot3StatsDuplexStatus
The current mode of operation of the MAC
entity. 'unknown' indicates that the current
duplex mode could not be determined.
Management control of the duplex mode is
accomplished through the MAU MIB. When
an interface does not support autonegotiation,
or when autonegotiation is not enabled, the
duplex mode is controlled using
ifMauDefaultType. When autonegotiation is
supported and enabled, duplex mode is controlled
using ifMauAutoNegAdvertisedBits. In either
case, the currently operating duplex mode is
reflected both in this object and in ifMauType.
Note that this object provides redundant
information with ifMauType. Normally, redundant
objects are discouraged. However, in this
instance, it allows a management application to
determine the duplex status of an interface
without having to know every possible value of
ifMauType. This was felt to be sufficiently
valuable to justify the redundancy.
Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus.
valuemap:
name: 'EtherLike-MIB::dot3StatsDuplexStatus'
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: 45b5778869124558b3265d6d7275c186
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/net.if.duplex[{#SNMPINDEX}])=2'
name: 'Cisco Catalyst 3750V2-24TS: Interface {#IFNAME}({#IFALIAS}): In half-duplex mode'
priority: WARNING
description: 'Please check autonegotiation settings and cabling'
tags:
- tag: scope
value: performance
- uuid: 742411a65e7f4b5fafc47e861ab8bd23
name: 'PSU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.5.1.2]'
key: psu.discovery
delay: 1h
description: 'The table of power supply status maintained by the environmental monitor card.'
item_prototypes:
- uuid: a3617fa8711146a0bdddd2e721cedb52
name: '{#SNMPVALUE}: Power supply status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.5.1.3.{#SNMPINDEX}]'
key: 'sensor.psu.status[{#SNMPINDEX}]'
description: |
MIB: CISCO-ENVMON-MIB
Object name: ciscoEnvMonSupplyState
valuemap:
name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
tags:
- tag: component
value: power
- tag: power-supply
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: 23fc241ca9d6438bb1688c77688fd1ed
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors'
tags:
- tag: scope
value: availability
- uuid: c6ed26fb555642c9b25564ec13fcf920
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=2'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Power supply is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Power supply is in critical state'
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4'
tags:
- tag: scope
value: availability
- uuid: 595c88262f2f48c99d16f22ab7d70aac
name: 'Temperature discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.3.1.2]'
key: temperature.discovery
delay: 1h
description: |
Discovery of ciscoEnvMonTemperatureTable (ciscoEnvMonTemperatureDescr), a table of ambient temperature status
maintained by the environmental monitor.
item_prototypes:
- uuid: e1636ece86b1427cad01e7223052b526
name: '{#SNMPVALUE}: Temperature status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.3.1.6.{#SNMPINDEX}]'
key: 'sensor.temp.status[{#SNMPINDEX}]'
description: |
MIB: CISCO-ENVMON-MIB
Object name: ciscoEnvMonTemperatureState
The current state of the test point being instrumented.
valuemap:
name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
tags:
- tag: component
value: temperature
- tag: sensor
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: 1820c365ad55416e995d4d978063e4a1
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is in critical state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor state'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 0b7e6f3085a0404ebb64c33828c9c920
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=2'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is in warning state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor state'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is in critical state'
expression: 'last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 16a4c905660349aaaddf52573916e187
name: '{#SNMPVALUE}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.3.1.3.{#SNMPINDEX}]'
key: 'sensor.temp.value[{#SNMPINDEX}]'
value_type: FLOAT
units: °C
description: |
MIB: CISCO-ENVMON-MIB
Object name: ciscoEnvMonTemperatureValue
The current measurement of the test point being instrumented.
tags:
- tag: component
value: temperature
- tag: sensor
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: 4c3501ee0c5b4af48306f040988d427a
expression: 'avg(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is above critical threshold'
event_name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 34b7d1a255a4408fac4d299eedc215b9
expression: 'avg(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is above warning threshold'
event_name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
- name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is above critical threshold'
expression: 'avg(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
recovery_expression: 'max(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: b9b8577c9f114d4c8546169e5a63a915
expression: 'avg(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'min(/Cisco Catalyst 3750V2-24TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is too low'
event_name: 'Cisco Catalyst 3750V2-24TS: {#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags:
- tag: scope
value: availability
- tag: scope
value: performance
tags:
- tag: class
value: network
- tag: target
value: cisco
- tag: target
value: cisco-catalyst
- tag: target
value: cisco-catalyst-3750v2-24ts
macros:
- macro: '{$CPU.UTIL.CRIT}'
value: '90'
description: 'Critical threshold of CPU utilization in %.'
- macro: '{$ICMP_LOSS_WARN}'
value: '20'
description: 'Warning threshold of ICMP packet loss in %.'
- macro: '{$ICMP_RESPONSE_TIME_WARN}'
value: '0.15'
description: 'Threshold of the average ICMP response time in seconds.'
- macro: '{$IF.ERRORS.WARN}'
value: '2'
description: 'Threshold for the warning level of the interface error packet rate.'
- macro: '{$IF.UTIL.MAX}'
value: '90'
description: 'Maximum threshold of interface bandwidth utilization in %. Can be used with the interface name as context.'
- macro: '{$IFCONTROL}'
value: '1'
description: 'Macro for the operational state of the interface for the link down trigger. Can be used with the interface name as context.'
- macro: '{$MEMORY.UTIL.MAX}'
value: '90'
description: 'Threshold for maximum memory utilization in %.'
- macro: '{$NET.IF.IFADMINSTATUS.MATCHES}'
value: '^.*'
description: 'This macro is used to include network interfaces by their administrative status.'
- macro: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}'
value: ^2$
description: 'Ignore down(2) administrative status'
- macro: '{$NET.IF.IFALIAS.MATCHES}'
value: '.*'
description: 'This macro is used to include network interfaces by their alias.'
- macro: '{$NET.IF.IFALIAS.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used to exclude network interfaces by their alias.'
- macro: '{$NET.IF.IFDESCR.MATCHES}'
value: '.*'
description: 'This macro is used to include network interfaces by their description.'
- macro: '{$NET.IF.IFDESCR.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used to exclude network interfaces by their description.'
- macro: '{$NET.IF.IFNAME.MATCHES}'
value: '^.*$'
description: 'This macro is used to include network interfaces by their name.'
- macro: '{$NET.IF.IFNAME.NOT_MATCHES}'
value: '(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})'
description: 'Filter out loopbacks, nulls, docker veth links and docker0 bridge by default'
- macro: '{$NET.IF.IFOPERSTATUS.MATCHES}'
value: '^.*$'
description: 'This macro is used to include network interfaces by their operational status.'
- macro: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}'
value: ^6$
description: 'Ignore notPresent(6)'
- macro: '{$NET.IF.IFTYPE.MATCHES}'
value: '.*'
description: 'This macro is used to include network interfaces by their type.'
- macro: '{$NET.IF.IFTYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used to exclude network interfaces by their type.'
- macro: '{$SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for the SNMP availability trigger.'
- macro: '{$TEMP_CRIT}'
value: '60'
description: 'Critical threshold of the temperature in °C.'
- macro: '{$TEMP_CRIT_LOW}'
value: '5'
description: 'Critical threshold of the low temperature in °C.'
- macro: '{$TEMP_WARN}'
value: '50'
description: 'Warning threshold of the temperature in °C.'
dashboards:
- uuid: 3bab64e9da084c928d10685f96574543
name: Resources
pages:
- name: Overview
widgets:
- type: graphprototype
width: '72'
height: '5'
fields:
- type: INTEGER
name: columns
value: '1'
- type: GRAPH_PROTOTYPE
name: graphid.0
value:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
name: '#{#SNMPINDEX}: CPU utilization'
- type: STRING
name: reference
value: AAAAA
- type: graphprototype
'y': '5'
width: '72'
height: '5'
fields:
- type: INTEGER
name: columns
value: '1'
- type: GRAPH_PROTOTYPE
name: graphid.0
value:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
name: '{#SNMPVALUE}: Memory utilization'
- type: STRING
name: reference
value: AAAAB
- type: graphprototype
'y': '10'
width: '72'
height: '10'
fields:
- type: INTEGER
name: columns
value: '1'
- type: GRAPH_PROTOTYPE
name: graphid.0
value:
host: 'Cisco Catalyst 3750V2-24TS by SNMP'
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
- type: STRING
name: reference
value: AAAAC
valuemaps:
- uuid: fea34445b6cd4847b420d212f9b0201e
name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
mappings:
- value: '1'
newvalue: normal
- value: '2'
newvalue: warning
- value: '3'
newvalue: critical
- value: '4'
newvalue: shutdown
- value: '5'
newvalue: notPresent
- value: '6'
newvalue: notFunctioning
- uuid: 867b0e42f8a24a278ee15476aeadfa0b
name: 'EtherLike-MIB::dot3StatsDuplexStatus'
mappings:
- value: '1'
newvalue: unknown
- value: '2'
newvalue: halfDuplex
- value: '3'
newvalue: fullDuplex
- uuid: 3534f9f22afe4f98a712a86ce755f491
name: 'IF-MIB::ifOperStatus'
mappings:
- value: '1'
newvalue: up
- value: '2'
newvalue: down
- value: '3'
newvalue: testing
- value: '4'
newvalue: unknown
- value: '5'
newvalue: dormant
- value: '6'
newvalue: notPresent
- value: '7'
newvalue: lowerLayerDown
- uuid: 88b99531b08248e8be1fc0a3210acee1
name: 'IF-MIB::ifType'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: regular1822
- value: '3'
newvalue: hdh1822
- value: '4'
newvalue: ddnX25
- value: '5'
newvalue: rfc877x25
- value: '6'
newvalue: ethernetCsmacd
- value: '7'
newvalue: iso88023Csmacd
- value: '8'
newvalue: iso88024TokenBus
- value: '9'
newvalue: iso88025TokenRing
- value: '10'
newvalue: iso88026Man
- value: '11'
newvalue: starLan
- value: '12'
newvalue: proteon10Mbit
- value: '13'
newvalue: proteon80Mbit
- value: '14'
newvalue: hyperchannel
- value: '15'
newvalue: fddi
- value: '16'
newvalue: lapb
- value: '17'
newvalue: sdlc
- value: '18'
newvalue: ds1
- value: '19'
newvalue: e1
- value: '20'
newvalue: basicISDN
- value: '21'
newvalue: primaryISDN
- value: '22'
newvalue: propPointToPointSerial
- value: '23'
newvalue: ppp
- value: '24'
newvalue: softwareLoopback
- value: '25'
newvalue: eon
- value: '26'
newvalue: ethernet3Mbit
- value: '27'
newvalue: nsip
- value: '28'
newvalue: slip
- value: '29'
newvalue: ultra
- value: '30'
newvalue: ds3
- value: '31'
newvalue: sip
- value: '32'
newvalue: frameRelay
- value: '33'
newvalue: rs232
- value: '34'
newvalue: para
- value: '35'
newvalue: arcnet
- value: '36'
newvalue: arcnetPlus
- value: '37'
newvalue: atm
- value: '38'
newvalue: miox25
- value: '39'
newvalue: sonet
- value: '40'
newvalue: x25ple
- value: '41'
newvalue: iso88022llc
- value: '42'
newvalue: localTalk
- value: '43'
newvalue: smdsDxi
- value: '44'
newvalue: frameRelayService
- value: '45'
newvalue: v35
- value: '46'
newvalue: hssi
- value: '47'
newvalue: hippi
- value: '48'
newvalue: modem
- value: '49'
newvalue: aal5
- value: '50'
newvalue: sonetPath
- value: '51'
newvalue: sonetVT
- value: '52'
newvalue: smdsIcip
- value: '53'
newvalue: propVirtual
- value: '54'
newvalue: propMultiplexor
- value: '55'
newvalue: ieee80212
- value: '56'
newvalue: fibreChannel
- value: '57'
newvalue: hippiInterface
- value: '58'
newvalue: frameRelayInterconnect
- value: '59'
newvalue: aflane8023
- value: '60'
newvalue: aflane8025
- value: '61'
newvalue: cctEmul
- value: '62'
newvalue: fastEther
- value: '63'
newvalue: isdn
- value: '64'
newvalue: v11
- value: '65'
newvalue: v36
- value: '66'
newvalue: g703at64k
- value: '67'
newvalue: g703at2mb
- value: '68'
newvalue: qllc
- value: '69'
newvalue: fastEtherFX
- value: '70'
newvalue: channel
- value: '71'
newvalue: ieee80211
- value: '72'
newvalue: ibm370parChan
- value: '73'
newvalue: escon
- value: '74'
newvalue: dlsw
- value: '75'
newvalue: isdns
- value: '76'
newvalue: isdnu
- value: '77'
newvalue: lapd
- value: '78'
newvalue: ipSwitch
- value: '79'
newvalue: rsrb
- value: '80'
newvalue: atmLogical
- value: '81'
newvalue: ds0
- value: '82'
newvalue: ds0Bundle
- value: '83'
newvalue: bsc
- value: '84'
newvalue: async
- value: '85'
newvalue: cnr
- value: '86'
newvalue: iso88025Dtr
- value: '87'
newvalue: eplrs
- value: '88'
newvalue: arap
- value: '89'
newvalue: propCnls
- value: '90'
newvalue: hostPad
- value: '91'
newvalue: termPad
- value: '92'
newvalue: frameRelayMPI
- value: '93'
newvalue: x213
- value: '94'
newvalue: adsl
- value: '95'
newvalue: radsl
- value: '96'
newvalue: sdsl
- value: '97'
newvalue: vdsl
- value: '98'
newvalue: iso88025CRFPInt
- value: '99'
newvalue: myrinet
- value: '100'
newvalue: voiceEM
- value: '101'
newvalue: voiceFXO
- value: '102'
newvalue: voiceFXS
- value: '103'
newvalue: voiceEncap
- value: '104'
newvalue: voiceOverIp
- value: '105'
newvalue: atmDxi
- value: '106'
newvalue: atmFuni
- value: '107'
newvalue: atmIma
- value: '108'
newvalue: pppMultilinkBundle
- value: '109'
newvalue: ipOverCdlc
- value: '110'
newvalue: ipOverClaw
- value: '111'
newvalue: stackToStack
- value: '112'
newvalue: virtualIpAddress
- value: '113'
newvalue: mpc
- value: '114'
newvalue: ipOverAtm
- value: '115'
newvalue: iso88025Fiber
- value: '116'
newvalue: tdlc
- value: '117'
newvalue: gigabitEthernet
- value: '118'
newvalue: hdlc
- value: '119'
newvalue: lapf
- value: '120'
newvalue: v37
- value: '121'
newvalue: x25mlp
- value: '122'
newvalue: x25huntGroup
- value: '123'
newvalue: trasnpHdlc
- value: '124'
newvalue: interleave
- value: '125'
newvalue: fast
- value: '126'
newvalue: ip
- value: '127'
newvalue: docsCableMaclayer
- value: '128'
newvalue: docsCableDownstream
- value: '129'
newvalue: docsCableUpstream
- value: '130'
newvalue: a12MppSwitch
- value: '131'
newvalue: tunnel
- value: '132'
newvalue: coffee
- value: '133'
newvalue: ces
- value: '134'
newvalue: atmSubInterface
- value: '135'
newvalue: l2vlan
- value: '136'
newvalue: l3ipvlan
- value: '137'
newvalue: l3ipxvlan
- value: '138'
newvalue: digitalPowerline
- value: '139'
newvalue: mediaMailOverIp
- value: '140'
newvalue: dtm
- value: '141'
newvalue: dcn
- value: '142'
newvalue: ipForward
- value: '143'
newvalue: msdsl
- value: '144'
newvalue: ieee1394
- value: '145'
newvalue: if-gsn
- value: '146'
newvalue: dvbRccMacLayer
- value: '147'
newvalue: dvbRccDownstream
- value: '148'
newvalue: dvbRccUpstream
- value: '149'
newvalue: atmVirtual
- value: '150'
newvalue: mplsTunnel
- value: '151'
newvalue: srp
- value: '152'
newvalue: voiceOverAtm
- value: '153'
newvalue: voiceOverFrameRelay
- value: '154'
newvalue: idsl
- value: '155'
newvalue: compositeLink
- value: '156'
newvalue: ss7SigLink
- value: '157'
newvalue: propWirelessP2P
- value: '158'
newvalue: frForward
- value: '159'
newvalue: rfc1483
- value: '160'
newvalue: usb
- value: '161'
newvalue: ieee8023adLag
- value: '162'
newvalue: bgppolicyaccounting
- value: '163'
newvalue: frf16MfrBundle
- value: '164'
newvalue: h323Gatekeeper
- value: '165'
newvalue: h323Proxy
- value: '166'
newvalue: mpls
- value: '167'
newvalue: mfSigLink
- value: '168'
newvalue: hdsl2
- value: '169'
newvalue: shdsl
- value: '170'
newvalue: ds1FDL
- value: '171'
newvalue: pos
- value: '172'
newvalue: dvbAsiIn
- value: '173'
newvalue: dvbAsiOut
- value: '174'
newvalue: plc
- value: '175'
newvalue: nfas
- value: '176'
newvalue: tr008
- value: '177'
newvalue: gr303RDT
- value: '178'
newvalue: gr303IDT
- value: '179'
newvalue: isup
- value: '180'
newvalue: propDocsWirelessMaclayer
- value: '181'
newvalue: propDocsWirelessDownstream
- value: '182'
newvalue: propDocsWirelessUpstream
- value: '183'
newvalue: hiperlan2
- value: '184'
newvalue: propBWAp2Mp
- value: '185'
newvalue: sonetOverheadChannel
- value: '186'
newvalue: digitalWrapperOverheadChannel
- value: '187'
newvalue: aal2
- value: '188'
newvalue: radioMAC
- value: '189'
newvalue: atmRadio
- value: '190'
newvalue: imt
- value: '191'
newvalue: mvl
- value: '192'
newvalue: reachDSL
- value: '193'
newvalue: frDlciEndPt
- value: '194'
newvalue: atmVciEndPt
- value: '195'
newvalue: opticalChannel
- value: '196'
newvalue: opticalTransport
- value: '197'
newvalue: propAtm
- value: '198'
newvalue: voiceOverCable
- value: '199'
newvalue: infiniband
- value: '200'
newvalue: teLink
- value: '201'
newvalue: q2931
- value: '202'
newvalue: virtualTg
- value: '203'
newvalue: sipTg
- value: '204'
newvalue: sipSig
- value: '205'
newvalue: docsCableUpstreamChannel
- value: '206'
newvalue: econet
- value: '207'
newvalue: pon155
- value: '208'
newvalue: pon622
- value: '209'
newvalue: bridge
- value: '210'
newvalue: linegroup
- value: '211'
newvalue: voiceEMFGD
- value: '212'
newvalue: voiceFGDEANA
- value: '213'
newvalue: voiceDID
- value: '214'
newvalue: mpegTransport
- value: '215'
newvalue: sixToFour
- value: '216'
newvalue: gtp
- value: '217'
newvalue: pdnEtherLoop1
- value: '218'
newvalue: pdnEtherLoop2
- value: '219'
newvalue: opticalChannelGroup
- value: '220'
newvalue: homepna
- value: '221'
newvalue: gfp
- value: '222'
newvalue: ciscoISLvlan
- value: '223'
newvalue: actelisMetaLOOP
- value: '224'
newvalue: fcipLink
- value: '225'
newvalue: rpr
- value: '226'
newvalue: qam
- value: '227'
newvalue: lmp
- value: '228'
newvalue: cblVectaStar
- value: '229'
newvalue: docsCableMCmtsDownstream
- value: '230'
newvalue: adsl2
- value: '231'
newvalue: macSecControlledIF
- value: '232'
newvalue: macSecUncontrolledIF
- value: '233'
newvalue: aviciOpticalEther
- value: '234'
newvalue: atmbond
- value: '235'
newvalue: voiceFGDOS
- value: '236'
newvalue: mocaVersion1
- value: '237'
newvalue: ieee80216WMAN
- value: '238'
newvalue: adsl2plus
- value: '239'
newvalue: dvbRcsMacLayer
- value: '240'
newvalue: dvbTdm
- value: '241'
newvalue: dvbRcsTdma
- value: '242'
newvalue: x86Laps
- value: '243'
newvalue: wwanPP
- value: '244'
newvalue: wwanPP2
- value: '245'
newvalue: voiceEBS
- value: '246'
newvalue: ifPwType
- value: '247'
newvalue: ilan
- value: '248'
newvalue: pip
- value: '249'
newvalue: aluELP
- value: '250'
newvalue: gpon
- value: '251'
newvalue: vdsl2
- value: '252'
newvalue: capwapDot11Profile
- value: '253'
newvalue: capwapDot11Bss
- value: '254'
newvalue: capwapWtpVirtualRadio
- value: '255'
newvalue: bits
- value: '256'
newvalue: docsCableUpstreamRfPort
- value: '257'
newvalue: cableDownstreamRfPort
- value: '258'
newvalue: vmwareVirtualNic
- value: '259'
newvalue: ieee802154
- value: '260'
newvalue: otnOdu
- value: '261'
newvalue: otnOtu
- value: '262'
newvalue: ifVfiType
- value: '263'
newvalue: g9981
- value: '264'
newvalue: g9982
- value: '265'
newvalue: g9983
- value: '266'
newvalue: aluEpon
- value: '267'
newvalue: aluEponOnu
- value: '268'
newvalue: aluEponPhysicalUni
- value: '269'
newvalue: aluEponLogicalLink
- value: '270'
newvalue: aluGponOnu
- value: '271'
newvalue: aluGponPhysicalUni
- value: '272'
newvalue: vmwareNicTeam
- value: '277'
newvalue: docsOfdmDownstream
- value: '278'
newvalue: docsOfdmaUpstream
- value: '279'
newvalue: gfast
- value: '280'
newvalue: sdci
- value: '281'
newvalue: xboxWireless
- value: '282'
newvalue: fastdsl
- value: '283'
newvalue: docsCableScte55d1FwdOob
- value: '284'
newvalue: docsCableScte55d1RetOob
- value: '285'
newvalue: docsCableScte55d2DsOob
- value: '286'
newvalue: docsCableScte55d2UsOob
- value: '287'
newvalue: docsCableNdf
- value: '288'
newvalue: docsCableNdr
- value: '289'
newvalue: ptm
- value: '290'
newvalue: ghn
- uuid: 653ce2314e6f499b84250048df1314f8
name: 'Service state'
mappings:
- value: '0'
newvalue: Down
- value: '1'
newvalue: Up
- uuid: 690c4c1545894d049ac8e26e3de7ec9c
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 86484c0d62e94532af4202267369f8bf
expression: '(last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.uptime)>0 and last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.uptime)<10m) or (last(/Cisco Catalyst 3750V2-24TS by SNMP/system.hw.uptime)=0 and last(/Cisco Catalyst 3750V2-24TS by SNMP/system.net.uptime)<10m)'
name: 'Cisco Catalyst 3750V2-24TS: Host has been restarted'
event_name: 'Cisco Catalyst 3750V2-24TS: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
tags:
- tag: scope