Files
templates-default/Cisco_Catalyst_3750V2-24PS_by_SNMP.yaml

1991 lines
87 KiB
YAML

zabbix_export:
version: '7.0'
template_groups:
- uuid: 36bff6c29af64692839d077febfc7079
name: 'Templates/Network devices'
templates:
- uuid: 4583f0c3bc894251a6c5e7129cb5b9aa
template: 'Cisco Catalyst 3750V2-24PS by SNMP'
name: 'Cisco Catalyst 3750V2-24PS by SNMP'
description: |
Template Cisco Catalyst 3750V2-24PS
MIBs used:
CISCO-MEMORY-POOL-MIB
IF-MIB
EtherLike-MIB
SNMPv2-MIB
CISCO-PROCESS-MIB
CISCO-ENVMON-MIB
ENTITY-MIB
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/418396-discussion-thread-for-official-zabbix-templates-for-cisco
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-4
groups:
- name: 'Templates/Network devices'
items:
- uuid: 84ef605d7c914f62b4497ed6fdaccd8a
name: 'ICMP ping'
type: SIMPLE
key: icmpping
valuemap:
name: 'Service state'
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: e66bcbef8f1d45fc8bc5d64e5dc848dc
expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/icmpping,#3)=0'
name: 'Cisco Catalyst 3750V2-24PS: Unavailable by ICMP ping'
priority: HIGH
description: 'Last three attempts returned timeout. Please check device connectivity.'
tags:
- tag: scope
value: availability
- uuid: c40980a878c94c3db61f80e206b890ec
name: 'ICMP loss'
type: SIMPLE
key: icmppingloss
value_type: FLOAT
units: '%'
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: 20ee878da19f4d758e4372c6c918c773
expression: 'min(/Cisco Catalyst 3750V2-24PS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-24PS by SNMP/icmppingloss,5m)<100'
name: 'Cisco Catalyst 3750V2-24PS: High ICMP ping loss'
opdata: 'Loss: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: Unavailable by ICMP ping'
expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/icmpping,#3)=0'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: d1c2bc9cee7046c2a17f876dce1f063f
name: 'ICMP response time'
type: SIMPLE
key: icmppingsec
value_type: FLOAT
units: s
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: 0facff81f25c43869e86a0541f0e3ecd
expression: 'avg(/Cisco Catalyst 3750V2-24PS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
name: 'Cisco Catalyst 3750V2-24PS: High ICMP ping response time'
opdata: 'Value: {ITEM.LASTVALUE1}'
priority: WARNING
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: High ICMP ping loss'
expression: 'min(/Cisco Catalyst 3750V2-24PS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-24PS by SNMP/icmppingloss,5m)<100'
- name: 'Cisco Catalyst 3750V2-24PS: Unavailable by ICMP ping'
expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/icmpping,#3)=0'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 612f59e4d582463bb386046a1d4342da
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'Item is used to collect all SNMP traps unmatched by other snmptrap items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: system
- uuid: 582260ed2f2d4f419651bc526e41b733
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: system.contact
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 956ce9527d604b4493d52815799590ca
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: system.descr
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should
include the full name and version identification of the system's hardware type, software operating-system, and
networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: fb4df28cb44941e5b39348afe421a2ad
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.13.1]'
key: system.hw.model
delay: 1h
value_type: CHAR
trends: '0'
description: 'MIB: ENTITY-MIB'
inventory_link: MODEL
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 664548f83e924a8aaa125579f230d0e9
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.11.1]'
key: system.hw.serialnumber
delay: 1h
value_type: CHAR
trends: '0'
description: 'MIB: ENTITY-MIB'
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 052fb88fae1349d5b9a5fa5bcf24d0fa
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.serialnumber,#1)<>last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.serialnumber,#2) and length(last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.serialnumber))>0'
name: 'Cisco Catalyst 3750V2-24PS: Device has been replaced'
event_name: 'Cisco Catalyst 3750V2-24PS: Device has been replaced (new serial number received)'
priority: INFO
description: 'The device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 24df0110b0d541118d6609c3f3922fe5
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]'
key: system.hw.uptime
trends: '0'
units: uptime
description: |
MIB: HOST-RESOURCES-MIB
The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
preprocessing:
- type: CHECK_NOT_SUPPORTED
parameters:
- '-1'
error_handler: CUSTOM_VALUE
error_handler_params: '0'
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: b6d1ee7b8b3e42e380f6aa44bf39c008
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: system.location
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: system
- uuid: 2f5f5b376c034f439ae19ed24e4d8bc5
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: system.name
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: system
triggers:
- uuid: a678341d899846158fea2deb57f923cf
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-24PS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-24PS by SNMP/system.name))>0'
name: 'Cisco Catalyst 3750V2-24PS: System name has changed'
event_name: 'Cisco Catalyst 3750V2-24PS: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: a9070d15765c4acaa856dde8ece57340
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.3.0]'
key: system.net.uptime
trends: '0'
units: uptime
description: |
MIB: SNMPv2-MIB
The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
preprocessing:
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: d791eebac4884924b7f40c08174aef00
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: system.objectid
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: system
- uuid: 2c7c4907dfdd46d18321f80b00152771
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: system.sw.os
delay: 1h
value_type: CHAR
trends: '0'
description: 'MIB: SNMPv2-MIB'
inventory_link: OS
preprocessing:
- type: REGEX
parameters:
- 'Version (.+), RELEASE'
- \1
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 3e5d53072021491bb2af276aff3e1a0b
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/system.sw.os,#1)<>last(/Cisco Catalyst 3750V2-24PS by SNMP/system.sw.os,#2) and length(last(/Cisco Catalyst 3750V2-24PS by SNMP/system.sw.os))>0'
recovery_mode: NONE
name: 'Cisco Catalyst 3750V2-24PS: Operating system description has changed'
priority: INFO
description: 'The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually.'
manual_close: 'YES'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: System name has changed'
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-24PS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-24PS by SNMP/system.name))>0'
tags:
- tag: scope
value: notice
- uuid: 92d5d0c598674f20a0228cc66a433e84
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: system
triggers:
- uuid: 0f2d48a1529c4ae49d58d466ed3a76e7
expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
name: 'Cisco Catalyst 3750V2-24PS: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: 8635e89e60fd4c65a47a6da2bf3c072d
name: 'CPU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.109.1.1.1.1.5]'
key: cpu.discovery
delay: 1h
description: |
If your IOS device has several CPUs, you must use CISCO-PROCESS-MIB and its object cpmCPUTotal5minRev from the table called cpmCPUTotalTable ,
indexed with cpmCPUTotalIndex .
This table allows CISCO-PROCESS-MIB to keep CPU statistics for different physical entities in the router,
like different CPU chips, group of CPUs, or CPUs in different modules/cards.
In case of a single CPU, cpmCPUTotalTable has only one entry.
item_prototypes:
- uuid: 32bac9ece98d497680e84e43d1ac8f8e
name: '#{#SNMPINDEX}: CPU utilization'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.109.1.1.1.1.8.{#SNMPINDEX}]'
key: 'system.cpu.util[{#SNMPINDEX}]'
delay: 5m
value_type: FLOAT
units: '%'
description: |
MIB: CISCO-PROCESS-MIB
Object name: cpmCPUTotal5minRev
The cpmCPUTotal5minRev MIB object provides a more accurate view of the performance of the router over time than the MIB objects cpmCPUTotal1minRev and cpmCPUTotal5secRev . These MIB objects are not accurate because they look at CPU at one minute and five second intervals, respectively. These MIBs enable you to monitor the trends and plan the capacity of your network. The recommended baseline rising threshold for cpmCPUTotal5minRev is 90 percent. Depending on the platform, some routers that run at 90 percent, for example, 2500s, can exhibit performance degradation versus a high-end router, for example, the 7500 series, which can operate fine.
Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15215-collect-cpu-util-snmp.html
tags:
- tag: component
value: cpu
- tag: cpu-index
value: '{#SNMPINDEX}'
trigger_prototypes:
- uuid: 471acd7fa3ad4040aba27535905bfe63
expression: 'min(/Cisco Catalyst 3750V2-24PS by SNMP/system.cpu.util[{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}'
name: 'Cisco Catalyst 3750V2-24PS: #{#SNMPINDEX}: High CPU utilization'
event_name: 'Cisco Catalyst 3750V2-24PS: #{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'The CPU utilization is too high. The system might be slow to respond.'
tags:
- tag: scope
value: capacity
- tag: scope
value: performance
graph_prototypes:
- uuid: ab67e338f5784971b7b5a1cac20097fb
name: '#{#SNMPINDEX}: CPU utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
- drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
key: 'system.cpu.util[{#SNMPINDEX}]'
- uuid: 7a62ebc0c38942fa9f72eebc839be5d7
name: 'Entity Serial Numbers discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#ENT_CLASS},1.3.6.1.2.1.47.1.1.1.1.5,{#ENT_NAME},1.3.6.1.2.1.47.1.1.1.1.7,{#ENT_SN},1.3.6.1.2.1.47.1.1.1.1.11]'
key: entity_sn.discovery
delay: 1h
filter:
evaltype: AND
conditions:
- macro: '{#ENT_CLASS}'
value: '[^3]'
formulaid: A
- macro: '{#ENT_SN}'
value: .+
formulaid: B
item_prototypes:
- uuid: ba6a0cf3f63b475d80a59e537302bbaa
name: '{#ENT_NAME}: Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.11.{#SNMPINDEX}]'
key: 'system.hw.serialnumber[{#SNMPINDEX}]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: ENTITY-MIB
Object name: entPhysicalSerialNum
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: serial-number
- tag: entity
value: '{#ENT_NAME}'
trigger_prototypes:
- uuid: 70aca80b5a8d414686967b104d301023
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#1)<>last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#2) and length(last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.serialnumber[{#SNMPINDEX}]))>0'
name: 'Cisco Catalyst 3750V2-24PS: {#ENT_NAME}: Device has been replaced'
event_name: 'Cisco Catalyst 3750V2-24PS: {#ENT_NAME}: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
tags:
- tag: scope
value: notice
- uuid: 235f74f154bc422482f524b9a4c08125
name: 'FAN discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.4.1.2]'
key: fan.discovery
delay: 1h
description: 'The table of fan status maintained by the environmental monitor.'
item_prototypes:
- uuid: d7ae10cf2595493aa6b31c52bbc6220d
name: '{#SNMPVALUE}: Fan status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.4.1.3.{#SNMPINDEX}]'
key: 'sensor.fan.status[{#SNMPINDEX}]'
description: |
MIB: CISCO-ENVMON-MIB
Object name: ciscoEnvMonFanState
valuemap:
name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
tags:
- tag: component
value: fan
- tag: fan
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: e2b72d874d4f48e79aab3a6d514663b4
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: d4bf389614f54be08ffd8d010e480da6
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.fan.status[{#SNMPINDEX}])=2'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Fan is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Fan is in critical state'
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 86589a8d54cb4cfc81c38a6eeac05b80
name: 'Memory discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.48.1.1.1.2]'
key: memory.discovery
delay: 1h
description: |
Discovery of ciscoMemoryPoolTable, a table of memory pool monitoring entries.
http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
item_prototypes:
- uuid: 8aa33136af58484ca1e0ee894dd9b22c
name: '{#SNMPVALUE}: Free memory'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.48.1.1.1.6.{#SNMPINDEX}]'
key: 'vm.memory.free[{#SNMPINDEX}]'
units: B
description: |
MIB: CISCO-MEMORY-POOL-MIB
Object name: ciscoMemoryPoolFree
Indicates the number of bytes from the memory pool that are currently unused on the managed device. Note that the sum of ciscoMemoryPoolUsed and ciscoMemoryPoolFree is the total amount of memory in the pool
Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
tags:
- tag: component
value: memory
- tag: memory
value: '{#SNMPVALUE}'
- uuid: 73a46e97c57e4fca912e74a7253e21f6
name: '{#SNMPVALUE}: Used memory'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.48.1.1.1.5.{#SNMPINDEX}]'
key: 'vm.memory.used[{#SNMPINDEX}]'
units: B
description: |
MIB: CISCO-MEMORY-POOL-MIB
Object name: ciscoMemoryPoolUsed
Indicates the number of bytes from the memory pool that are currently in use by applications on the managed device.
Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html
tags:
- tag: component
value: memory
- tag: memory
value: '{#SNMPVALUE}'
- uuid: 50638b5c78584c99978c6b57bec520d4
name: '{#SNMPVALUE}: Memory utilization'
type: CALCULATED
key: 'vm.memory.util[{#SNMPINDEX}]'
value_type: FLOAT
units: '%'
params: 'last(//vm.memory.used[{#SNMPINDEX}])/(last(//vm.memory.free[{#SNMPINDEX}])+last(//vm.memory.used[{#SNMPINDEX}]))*100'
description: 'Memory utilization in %'
tags:
- tag: component
value: memory
- tag: memory
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: 918cf48b69d545dbb9f177fa1440f4cb
expression: 'min(/Cisco Catalyst 3750V2-24PS by SNMP/vm.memory.util[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: High memory utilization'
event_name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: High memory utilization ( >{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
description: 'The system is running out of free memory.'
tags:
- tag: scope
value: capacity
- tag: scope
value: performance
graph_prototypes:
- uuid: e86ef2331d1644ca80b28f0855a7a7e9
name: '{#SNMPVALUE}: Memory utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
- drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
key: 'vm.memory.util[{#SNMPINDEX}]'
- uuid: 2b0dacd3b651413fb674eac430613286
name: 'Network interfaces discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]'
key: net.if.discovery
delay: 1h
filter:
evaltype: AND
conditions:
- macro: '{#IFADMINSTATUS}'
value: '{$NET.IF.IFADMINSTATUS.MATCHES}'
formulaid: A
- macro: '{#IFADMINSTATUS}'
value: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#IFALIAS}'
value: '{$NET.IF.IFALIAS.MATCHES}'
formulaid: C
- macro: '{#IFALIAS}'
value: '{$NET.IF.IFALIAS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
- macro: '{#IFDESCR}'
value: '{$NET.IF.IFDESCR.MATCHES}'
formulaid: E
- macro: '{#IFDESCR}'
value: '{$NET.IF.IFDESCR.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: F
- macro: '{#IFNAME}'
value: '{$NET.IF.IFNAME.MATCHES}'
formulaid: G
- macro: '{#IFNAME}'
value: '{$NET.IF.IFNAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: H
- macro: '{#IFOPERSTATUS}'
value: '{$NET.IF.IFOPERSTATUS.MATCHES}'
formulaid: I
- macro: '{#IFOPERSTATUS}'
value: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: J
- macro: '{#IFTYPE}'
value: '{$NET.IF.IFTYPE.MATCHES}'
formulaid: K
- macro: '{#IFTYPE}'
value: '{$NET.IF.IFTYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: L
description: 'Discovering interfaces from IF-MIB.'
item_prototypes:
- uuid: 670a337b61b8485da83bff8fb357aa6c
name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}]'
key: 'net.if.in.discards[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
The number of inbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 677b9af6e45e42c1bc59772453778de2
name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}]'
key: 'net.if.in.errors[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: df6bfacc52e1487d9f359c23545ceb84
expression: 'min(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8'
name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): High input error rate'
event_name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): High input error rate ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors in: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: performance
- uuid: d745a153bdd443afb3b6c690a6cb1834
name: 'Interface {#IFNAME}({#IFALIAS}): Bits received'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}]'
key: 'net.if.in[{#SNMPINDEX}]'
units: bps
description: |
MIB: IF-MIB
The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
- type: MULTIPLIER
parameters:
- '8'
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: e000bdb0549747b98ef9ef824ead399d
name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}]'
key: 'net.if.out.discards[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
The number of outbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: bf863b01e546466e9f7516435fd34631
name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}]'
key: 'net.if.out.errors[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: aa49d99c77d64e31ad2369d09e547cab
expression: 'min(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8'
name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): High output error rate'
event_name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): High output error rate ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors out: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: performance
- uuid: 8b9edde24248456f902880625e33e289
name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}]'
key: 'net.if.out[{#SNMPINDEX}]'
units: bps
description: |
MIB: IF-MIB
The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
- type: MULTIPLIER
parameters:
- '8'
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: fa0715f32e7441958e1d555efe7ccc9f
name: 'Interface {#IFNAME}({#IFALIAS}): Speed'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}]'
key: 'net.if.speed[{#SNMPINDEX}]'
units: bps
description: |
MIB: IF-MIB
An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.
preprocessing:
- type: MULTIPLIER
parameters:
- '1000000'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 94183e5ed20f4f5495162b696097fd70
name: 'Interface {#IFNAME}({#IFALIAS}): Operational status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}]'
key: 'net.if.status[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
The current operational state of the interface.
- The testing(3) state indicates that no operational packet scan be passed
- If ifAdminStatus is down(2) then ifOperStatus should be down(2)
- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic
- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)
- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state
- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.
valuemap:
name: 'IF-MIB::ifOperStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: 41d6b4a9fde546ae88005efdef1f4525
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): Link down'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is down.
2. `{ $IFCONTROL:"{#IFNAME}" }=1` - a user can redefine context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.
tags:
- tag: scope
value: availability
- uuid: 27b0676374f847ad8330028e62b7b6af
name: 'Interface {#IFNAME}({#IFALIAS}): Interface type'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}]'
key: 'net.if.type[{#SNMPINDEX}]'
description: |
MIB: IF-MIB
The type of interface.
Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA),
through updating the syntax of the IANAifType textual convention.
valuemap:
name: 'IF-MIB::ifType'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: d6aaa83ed4744ef982a177b77fb1f2c4
expression: |
change(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])<0 and last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])>0
and (
last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.type[{#SNMPINDEX}])=6 or
last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.type[{#SNMPINDEX}])=7 or
last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.type[{#SNMPINDEX}])=11 or
last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.type[{#SNMPINDEX}])=62 or
last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.type[{#SNMPINDEX}])=69 or
last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.type[{#SNMPINDEX}])=117
)
and
(last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.status[{#SNMPINDEX}])<>2)
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
(change(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])>0 and last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}],#2)>0) or
(last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.status[{#SNMPINDEX}])=2)
name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before'
opdata: 'Current reported speed: {ITEM.LASTVALUE1}'
priority: INFO
description: 'This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: notice
- uuid: 9e3e50611ef242b0b200c0a6343f4c5c
expression: |
(avg(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.in[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])) and
last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])>0
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'avg(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.in[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])'
name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage'
event_name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage ( > {$IF.UTIL.MAX:"{#IFNAME}"}% )'
opdata: 'In: {ITEM.LASTVALUE1}, speed: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'The utilization of the network interface is close to its estimated maximum bandwidth.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: performance
- uuid: 7c624697cd7b41d682b5856a3040737e
expression: |
(avg(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.out[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])) and
last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])>0
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'avg(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.out[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.speed[{#SNMPINDEX}])'
name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage'
event_name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage ( > {$IF.UTIL.MAX:"{#IFNAME}"}% )'
opdata: 'Out: {ITEM.LASTVALUE1}, speed: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'The utilization of the network interface is close to its estimated maximum bandwidth.'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.status[{#SNMPINDEX}])=2)'
tags:
- tag: scope
value: performance
graph_prototypes:
- uuid: f277c62e4c614924a79715beae06a63b
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
graph_items:
- drawtype: GRADIENT_LINE
color: 1A7C11
item:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
key: 'net.if.in[{#SNMPINDEX}]'
- sortorder: '1'
drawtype: BOLD_LINE
color: 2774A4
item:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
key: 'net.if.out[{#SNMPINDEX}]'
- sortorder: '2'
color: F63100
yaxisside: RIGHT
item:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
key: 'net.if.out.errors[{#SNMPINDEX}]'
- sortorder: '3'
color: A54F10
yaxisside: RIGHT
item:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
key: 'net.if.in.errors[{#SNMPINDEX}]'
- sortorder: '4'
color: FC6EA3
yaxisside: RIGHT
item:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
key: 'net.if.out.discards[{#SNMPINDEX}]'
- sortorder: '5'
color: 6C59DC
yaxisside: RIGHT
item:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
key: 'net.if.in.discards[{#SNMPINDEX}]'
- uuid: dbfa0bb2cc7a4a08a50311e37c6bc94b
name: 'EtherLike discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.2.1.10.7.2.1.19,{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2]'
key: net.if.duplex.discovery
delay: 1h
filter:
evaltype: AND
conditions:
- macro: '{#IFOPERSTATUS}'
value: '1'
formulaid: A
- macro: '{#SNMPVALUE}'
value: (2|3)
formulaid: B
description: 'Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered.'
item_prototypes:
- uuid: a5008d1d42d9472392b456b1d8af2568
name: 'Interface {#IFNAME}({#IFALIAS}): Duplex status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.10.7.2.1.19.{#SNMPINDEX}]'
key: 'net.if.duplex[{#SNMPINDEX}]'
description: |
MIB: EtherLike-MIB
Object name: dot3StatsDuplexStatus
The current mode of operation of the MAC
entity. 'unknown' indicates that the current
duplex mode could not be determined.
Management control of the duplex mode is
accomplished through the MAU MIB. When
an interface does not support autonegotiation,
or when autonegotiation is not enabled, the
duplex mode is controlled using
ifMauDefaultType. When autonegotiation is
supported and enabled, duplex mode is controlled
using ifMauAutoNegAdvertisedBits. In either
case, the currently operating duplex mode is
reflected both in this object and in ifMauType.
Note that this object provides redundant
information with ifMauType. Normally, redundant
objects are discouraged. However, in this
instance, it allows a management application to
determine the duplex status of an interface
without having to know every possible value of
ifMauType. This was felt to be sufficiently
valuable to justify the redundancy.
Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus.
valuemap:
name: 'EtherLike-MIB::dot3StatsDuplexStatus'
tags:
- tag: component
value: interface
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: df8eb5498b8a41709db02b742fa24d6a
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/net.if.duplex[{#SNMPINDEX}])=2'
name: 'Cisco Catalyst 3750V2-24PS: Interface {#IFNAME}({#IFALIAS}): In half-duplex mode'
priority: WARNING
description: 'Please check autonegotiation settings and cabling'
tags:
- tag: scope
value: performance
- uuid: 400dddbb882445af9e7b986bc4529908
name: 'PSU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.5.1.2]'
key: psu.discovery
delay: 1h
description: 'The table of power supply status maintained by the environmental monitor card.'
item_prototypes:
- uuid: 317bb1028c0b46fbac62df30e0ac6653
name: '{#SNMPVALUE}: Power supply status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.5.1.3.{#SNMPINDEX}]'
key: 'sensor.psu.status[{#SNMPINDEX}]'
description: |
MIB: CISCO-ENVMON-MIB
Object name: ciscoEnvMonSupplyState
valuemap:
name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
tags:
- tag: component
value: power
- tag: power-supply
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: 1d509ec30e8349538d9d2b2447b70253
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors'
tags:
- tag: scope
value: availability
- uuid: 4ef4e09de93e4cfbb2aab4f22e78c223
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.psu.status[{#SNMPINDEX}])=2'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Power supply is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Power supply is in critical state'
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4'
tags:
- tag: scope
value: availability
- uuid: b4eb58fb8820452d89447b786cee3361
name: 'Temperature discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.3.1.2]'
key: temperature.discovery
delay: 1h
description: |
Discovery of ciscoEnvMonTemperatureTable (ciscoEnvMonTemperatureDescr), a table of ambient temperature status
maintained by the environmental monitor.
item_prototypes:
- uuid: 774a9aa6ec954121ae96f7f76f7e3022
name: '{#SNMPVALUE}: Temperature status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.3.1.6.{#SNMPINDEX}]'
key: 'sensor.temp.status[{#SNMPINDEX}]'
description: |
MIB: CISCO-ENVMON-MIB
Object name: ciscoEnvMonTemperatureState
The current state of the test point being instrumented.
valuemap:
name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
tags:
- tag: component
value: temperature
- tag: sensor
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: 506c98e9c29247cba7c58ca343c6fdf4
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is in critical state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor state'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: d6b91f3e280c4d0fa3df0bf3fedd9183
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.status[{#SNMPINDEX}])=2'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is in warning state'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor state'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is in critical state'
expression: 'last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 44a96489bbfc4245b8fe0ffee74e0c96
name: '{#SNMPVALUE}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.3.1.3.{#SNMPINDEX}]'
key: 'sensor.temp.value[{#SNMPINDEX}]'
value_type: FLOAT
units: °C
description: |
MIB: CISCO-ENVMON-MIB
Object name: ciscoEnvMonTemperatureValue
The current measurement of the test point being instrumented.
tags:
- tag: component
value: temperature
- tag: sensor
value: '{#SNMPVALUE}'
trigger_prototypes:
- uuid: 63e41d0fe43c4daa8fd2e4eee6e4ed8a
expression: 'avg(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is above critical threshold'
event_name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: cc09047db63a435e816e560c2007b43a
expression: 'avg(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is above warning threshold'
event_name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
- name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is above critical threshold'
expression: 'avg(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}'
recovery_expression: 'max(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 156a35b375ff4978a2b98f38785897a5
expression: 'avg(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'min(/Cisco Catalyst 3750V2-24PS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3'
name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is too low'
event_name: 'Cisco Catalyst 3750V2-24PS: {#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags:
- tag: scope
value: availability
- tag: scope
value: performance
tags:
- tag: class
value: network
- tag: target
value: cisco
- tag: target
value: cisco-catalyst
- tag: target
value: cisco-catalyst-3750v2-24ps
macros:
- macro: '{$CPU.UTIL.CRIT}'
value: '90'
description: 'Critical threshold of CPU utilization in %.'
- macro: '{$ICMP_LOSS_WARN}'
value: '20'
description: 'Warning threshold of ICMP packet loss in %.'
- macro: '{$ICMP_RESPONSE_TIME_WARN}'
value: '0.15'
description: 'Threshold of the average ICMP response time in seconds.'
- macro: '{$IF.ERRORS.WARN}'
value: '2'
description: 'Threshold for the warning level of the interface error packet rate.'
- macro: '{$IF.UTIL.MAX}'
value: '90'
description: 'Maximum threshold of interface bandwidth utilization in %. Can be used with the interface name as context.'
- macro: '{$IFCONTROL}'
value: '1'
description: 'Macro for the operational state of the interface for the link down trigger. Can be used with the interface name as context.'
- macro: '{$MEMORY.UTIL.MAX}'
value: '90'
description: 'Threshold for maximum memory utilization in %.'
- macro: '{$NET.IF.IFADMINSTATUS.MATCHES}'
value: '^.*'
description: 'This macro is used to include network interfaces by their administrative status.'
- macro: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}'
value: ^2$
description: 'Ignore down(2) administrative status'
- macro: '{$NET.IF.IFALIAS.MATCHES}'
value: '.*'
description: 'This macro is used to include network interfaces by their alias.'
- macro: '{$NET.IF.IFALIAS.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used to exclude network interfaces by their alias.'
- macro: '{$NET.IF.IFDESCR.MATCHES}'
value: '.*'
description: 'This macro is used to include network interfaces by their description.'
- macro: '{$NET.IF.IFDESCR.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used to exclude network interfaces by their description.'
- macro: '{$NET.IF.IFNAME.MATCHES}'
value: '^.*$'
description: 'This macro is used to include network interfaces by their name.'
- macro: '{$NET.IF.IFNAME.NOT_MATCHES}'
value: '(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})'
description: 'Filter out loopbacks, nulls, docker veth links and docker0 bridge by default'
- macro: '{$NET.IF.IFOPERSTATUS.MATCHES}'
value: '^.*$'
description: 'This macro is used to include network interfaces by their operational status.'
- macro: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}'
value: ^6$
description: 'Ignore notPresent(6)'
- macro: '{$NET.IF.IFTYPE.MATCHES}'
value: '.*'
description: 'This macro is used to include network interfaces by their type.'
- macro: '{$NET.IF.IFTYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'This macro is used to exclude network interfaces by their type.'
- macro: '{$SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for the SNMP availability trigger.'
- macro: '{$TEMP_CRIT}'
value: '60'
description: 'Critical threshold of the temperature in °C.'
- macro: '{$TEMP_CRIT_LOW}'
value: '5'
description: 'Critical threshold of the low temperature in °C.'
- macro: '{$TEMP_WARN}'
value: '50'
description: 'Warning threshold of the temperature in °C.'
dashboards:
- uuid: ffceccccc6564b429a4f440f08d08bc4
name: Resources
pages:
- name: Overview
widgets:
- type: graphprototype
width: '72'
height: '5'
fields:
- type: INTEGER
name: columns
value: '1'
- type: GRAPH_PROTOTYPE
name: graphid.0
value:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
name: '#{#SNMPINDEX}: CPU utilization'
- type: STRING
name: reference
value: AAAAA
- type: graphprototype
'y': '5'
width: '72'
height: '5'
fields:
- type: INTEGER
name: columns
value: '1'
- type: GRAPH_PROTOTYPE
name: graphid.0
value:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
name: '{#SNMPVALUE}: Memory utilization'
- type: STRING
name: reference
value: AAAAB
- type: graphprototype
'y': '10'
width: '72'
height: '10'
fields:
- type: INTEGER
name: columns
value: '1'
- type: GRAPH_PROTOTYPE
name: graphid.0
value:
host: 'Cisco Catalyst 3750V2-24PS by SNMP'
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
- type: STRING
name: reference
value: AAAAC
valuemaps:
- uuid: cbeb53fa3c2a4b16b7f7ee92265efd8c
name: 'CISCO-ENVMON-MIB::CiscoEnvMonState'
mappings:
- value: '1'
newvalue: normal
- value: '2'
newvalue: warning
- value: '3'
newvalue: critical
- value: '4'
newvalue: shutdown
- value: '5'
newvalue: notPresent
- value: '6'
newvalue: notFunctioning
- uuid: 5ef472cb5f424ef9a7393156204613ba
name: 'EtherLike-MIB::dot3StatsDuplexStatus'
mappings:
- value: '1'
newvalue: unknown
- value: '2'
newvalue: halfDuplex
- value: '3'
newvalue: fullDuplex
- uuid: 73b7c034142043b689792e1e71dd5872
name: 'IF-MIB::ifOperStatus'
mappings:
- value: '1'
newvalue: up
- value: '2'
newvalue: down
- value: '3'
newvalue: testing
- value: '4'
newvalue: unknown
- value: '5'
newvalue: dormant
- value: '6'
newvalue: notPresent
- value: '7'
newvalue: lowerLayerDown
- uuid: 635461b9ca404cc1b92c1fab0c6327f6
name: 'IF-MIB::ifType'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: regular1822
- value: '3'
newvalue: hdh1822
- value: '4'
newvalue: ddnX25
- value: '5'
newvalue: rfc877x25
- value: '6'
newvalue: ethernetCsmacd
- value: '7'
newvalue: iso88023Csmacd
- value: '8'
newvalue: iso88024TokenBus
- value: '9'
newvalue: iso88025TokenRing
- value: '10'
newvalue: iso88026Man
- value: '11'
newvalue: starLan
- value: '12'
newvalue: proteon10Mbit
- value: '13'
newvalue: proteon80Mbit
- value: '14'
newvalue: hyperchannel
- value: '15'
newvalue: fddi
- value: '16'
newvalue: lapb
- value: '17'
newvalue: sdlc
- value: '18'
newvalue: ds1
- value: '19'
newvalue: e1
- value: '20'
newvalue: basicISDN
- value: '21'
newvalue: primaryISDN
- value: '22'
newvalue: propPointToPointSerial
- value: '23'
newvalue: ppp
- value: '24'
newvalue: softwareLoopback
- value: '25'
newvalue: eon
- value: '26'
newvalue: ethernet3Mbit
- value: '27'
newvalue: nsip
- value: '28'
newvalue: slip
- value: '29'
newvalue: ultra
- value: '30'
newvalue: ds3
- value: '31'
newvalue: sip
- value: '32'
newvalue: frameRelay
- value: '33'
newvalue: rs232
- value: '34'
newvalue: para
- value: '35'
newvalue: arcnet
- value: '36'
newvalue: arcnetPlus
- value: '37'
newvalue: atm
- value: '38'
newvalue: miox25
- value: '39'
newvalue: sonet
- value: '40'
newvalue: x25ple
- value: '41'
newvalue: iso88022llc
- value: '42'
newvalue: localTalk
- value: '43'
newvalue: smdsDxi
- value: '44'
newvalue: frameRelayService
- value: '45'
newvalue: v35
- value: '46'
newvalue: hssi
- value: '47'
newvalue: hippi
- value: '48'
newvalue: modem
- value: '49'
newvalue: aal5
- value: '50'
newvalue: sonetPath
- value: '51'
newvalue: sonetVT
- value: '52'
newvalue: smdsIcip
- value: '53'
newvalue: propVirtual
- value: '54'
newvalue: propMultiplexor
- value: '55'
newvalue: ieee80212
- value: '56'
newvalue: fibreChannel
- value: '57'
newvalue: hippiInterface
- value: '58'
newvalue: frameRelayInterconnect
- value: '59'
newvalue: aflane8023
- value: '60'
newvalue: aflane8025
- value: '61'
newvalue: cctEmul
- value: '62'
newvalue: fastEther
- value: '63'
newvalue: isdn
- value: '64'
newvalue: v11
- value: '65'
newvalue: v36
- value: '66'
newvalue: g703at64k
- value: '67'
newvalue: g703at2mb
- value: '68'
newvalue: qllc
- value: '69'
newvalue: fastEtherFX
- value: '70'
newvalue: channel
- value: '71'
newvalue: ieee80211
- value: '72'
newvalue: ibm370parChan
- value: '73'
newvalue: escon
- value: '74'
newvalue: dlsw
- value: '75'
newvalue: isdns
- value: '76'
newvalue: isdnu
- value: '77'
newvalue: lapd
- value: '78'
newvalue: ipSwitch
- value: '79'
newvalue: rsrb
- value: '80'
newvalue: atmLogical
- value: '81'
newvalue: ds0
- value: '82'
newvalue: ds0Bundle
- value: '83'
newvalue: bsc
- value: '84'
newvalue: async
- value: '85'
newvalue: cnr
- value: '86'
newvalue: iso88025Dtr
- value: '87'
newvalue: eplrs
- value: '88'
newvalue: arap
- value: '89'
newvalue: propCnls
- value: '90'
newvalue: hostPad
- value: '91'
newvalue: termPad
- value: '92'
newvalue: frameRelayMPI
- value: '93'
newvalue: x213
- value: '94'
newvalue: adsl
- value: '95'
newvalue: radsl
- value: '96'
newvalue: sdsl
- value: '97'
newvalue: vdsl
- value: '98'
newvalue: iso88025CRFPInt
- value: '99'
newvalue: myrinet
- value: '100'
newvalue: voiceEM
- value: '101'
newvalue: voiceFXO
- value: '102'
newvalue: voiceFXS
- value: '103'
newvalue: voiceEncap
- value: '104'
newvalue: voiceOverIp
- value: '105'
newvalue: atmDxi
- value: '106'
newvalue: atmFuni
- value: '107'
newvalue: atmIma
- value: '108'
newvalue: pppMultilinkBundle
- value: '109'
newvalue: ipOverCdlc
- value: '110'
newvalue: ipOverClaw
- value: '111'
newvalue: stackToStack
- value: '112'
newvalue: virtualIpAddress
- value: '113'
newvalue: mpc
- value: '114'
newvalue: ipOverAtm
- value: '115'
newvalue: iso88025Fiber
- value: '116'
newvalue: tdlc
- value: '117'
newvalue: gigabitEthernet
- value: '118'
newvalue: hdlc
- value: '119'
newvalue: lapf
- value: '120'
newvalue: v37
- value: '121'
newvalue: x25mlp
- value: '122'
newvalue: x25huntGroup
- value: '123'
newvalue: trasnpHdlc
- value: '124'
newvalue: interleave
- value: '125'
newvalue: fast
- value: '126'
newvalue: ip
- value: '127'
newvalue: docsCableMaclayer
- value: '128'
newvalue: docsCableDownstream
- value: '129'
newvalue: docsCableUpstream
- value: '130'
newvalue: a12MppSwitch
- value: '131'
newvalue: tunnel
- value: '132'
newvalue: coffee
- value: '133'
newvalue: ces
- value: '134'
newvalue: atmSubInterface
- value: '135'
newvalue: l2vlan
- value: '136'
newvalue: l3ipvlan
- value: '137'
newvalue: l3ipxvlan
- value: '138'
newvalue: digitalPowerline
- value: '139'
newvalue: mediaMailOverIp
- value: '140'
newvalue: dtm
- value: '141'
newvalue: dcn
- value: '142'
newvalue: ipForward
- value: '143'
newvalue: msdsl
- value: '144'
newvalue: ieee1394
- value: '145'
newvalue: if-gsn
- value: '146'
newvalue: dvbRccMacLayer
- value: '147'
newvalue: dvbRccDownstream
- value: '148'
newvalue: dvbRccUpstream
- value: '149'
newvalue: atmVirtual
- value: '150'
newvalue: mplsTunnel
- value: '151'
newvalue: srp
- value: '152'
newvalue: voiceOverAtm
- value: '153'
newvalue: voiceOverFrameRelay
- value: '154'
newvalue: idsl
- value: '155'
newvalue: compositeLink
- value: '156'
newvalue: ss7SigLink
- value: '157'
newvalue: propWirelessP2P
- value: '158'
newvalue: frForward
- value: '159'
newvalue: rfc1483
- value: '160'
newvalue: usb
- value: '161'
newvalue: ieee8023adLag
- value: '162'
newvalue: bgppolicyaccounting
- value: '163'
newvalue: frf16MfrBundle
- value: '164'
newvalue: h323Gatekeeper
- value: '165'
newvalue: h323Proxy
- value: '166'
newvalue: mpls
- value: '167'
newvalue: mfSigLink
- value: '168'
newvalue: hdsl2
- value: '169'
newvalue: shdsl
- value: '170'
newvalue: ds1FDL
- value: '171'
newvalue: pos
- value: '172'
newvalue: dvbAsiIn
- value: '173'
newvalue: dvbAsiOut
- value: '174'
newvalue: plc
- value: '175'
newvalue: nfas
- value: '176'
newvalue: tr008
- value: '177'
newvalue: gr303RDT
- value: '178'
newvalue: gr303IDT
- value: '179'
newvalue: isup
- value: '180'
newvalue: propDocsWirelessMaclayer
- value: '181'
newvalue: propDocsWirelessDownstream
- value: '182'
newvalue: propDocsWirelessUpstream
- value: '183'
newvalue: hiperlan2
- value: '184'
newvalue: propBWAp2Mp
- value: '185'
newvalue: sonetOverheadChannel
- value: '186'
newvalue: digitalWrapperOverheadChannel
- value: '187'
newvalue: aal2
- value: '188'
newvalue: radioMAC
- value: '189'
newvalue: atmRadio
- value: '190'
newvalue: imt
- value: '191'
newvalue: mvl
- value: '192'
newvalue: reachDSL
- value: '193'
newvalue: frDlciEndPt
- value: '194'
newvalue: atmVciEndPt
- value: '195'
newvalue: opticalChannel
- value: '196'
newvalue: opticalTransport
- value: '197'
newvalue: propAtm
- value: '198'
newvalue: voiceOverCable
- value: '199'
newvalue: infiniband
- value: '200'
newvalue: teLink
- value: '201'
newvalue: q2931
- value: '202'
newvalue: virtualTg
- value: '203'
newvalue: sipTg
- value: '204'
newvalue: sipSig
- value: '205'
newvalue: docsCableUpstreamChannel
- value: '206'
newvalue: econet
- value: '207'
newvalue: pon155
- value: '208'
newvalue: pon622
- value: '209'
newvalue: bridge
- value: '210'
newvalue: linegroup
- value: '211'
newvalue: voiceEMFGD
- value: '212'
newvalue: voiceFGDEANA
- value: '213'
newvalue: voiceDID
- value: '214'
newvalue: mpegTransport
- value: '215'
newvalue: sixToFour
- value: '216'
newvalue: gtp
- value: '217'
newvalue: pdnEtherLoop1
- value: '218'
newvalue: pdnEtherLoop2
- value: '219'
newvalue: opticalChannelGroup
- value: '220'
newvalue: homepna
- value: '221'
newvalue: gfp
- value: '222'
newvalue: ciscoISLvlan
- value: '223'
newvalue: actelisMetaLOOP
- value: '224'
newvalue: fcipLink
- value: '225'
newvalue: rpr
- value: '226'
newvalue: qam
- value: '227'
newvalue: lmp
- value: '228'
newvalue: cblVectaStar
- value: '229'
newvalue: docsCableMCmtsDownstream
- value: '230'
newvalue: adsl2
- value: '231'
newvalue: macSecControlledIF
- value: '232'
newvalue: macSecUncontrolledIF
- value: '233'
newvalue: aviciOpticalEther
- value: '234'
newvalue: atmbond
- value: '235'
newvalue: voiceFGDOS
- value: '236'
newvalue: mocaVersion1
- value: '237'
newvalue: ieee80216WMAN
- value: '238'
newvalue: adsl2plus
- value: '239'
newvalue: dvbRcsMacLayer
- value: '240'
newvalue: dvbTdm
- value: '241'
newvalue: dvbRcsTdma
- value: '242'
newvalue: x86Laps
- value: '243'
newvalue: wwanPP
- value: '244'
newvalue: wwanPP2
- value: '245'
newvalue: voiceEBS
- value: '246'
newvalue: ifPwType
- value: '247'
newvalue: ilan
- value: '248'
newvalue: pip
- value: '249'
newvalue: aluELP
- value: '250'
newvalue: gpon
- value: '251'
newvalue: vdsl2
- value: '252'
newvalue: capwapDot11Profile
- value: '253'
newvalue: capwapDot11Bss
- value: '254'
newvalue: capwapWtpVirtualRadio
- value: '255'
newvalue: bits
- value: '256'
newvalue: docsCableUpstreamRfPort
- value: '257'
newvalue: cableDownstreamRfPort
- value: '258'
newvalue: vmwareVirtualNic
- value: '259'
newvalue: ieee802154
- value: '260'
newvalue: otnOdu
- value: '261'
newvalue: otnOtu
- value: '262'
newvalue: ifVfiType
- value: '263'
newvalue: g9981
- value: '264'
newvalue: g9982
- value: '265'
newvalue: g9983
- value: '266'
newvalue: aluEpon
- value: '267'
newvalue: aluEponOnu
- value: '268'
newvalue: aluEponPhysicalUni
- value: '269'
newvalue: aluEponLogicalLink
- value: '270'
newvalue: aluGponOnu
- value: '271'
newvalue: aluGponPhysicalUni
- value: '272'
newvalue: vmwareNicTeam
- value: '277'
newvalue: docsOfdmDownstream
- value: '278'
newvalue: docsOfdmaUpstream
- value: '279'
newvalue: gfast
- value: '280'
newvalue: sdci
- value: '281'
newvalue: xboxWireless
- value: '282'
newvalue: fastdsl
- value: '283'
newvalue: docsCableScte55d1FwdOob
- value: '284'
newvalue: docsCableScte55d1RetOob
- value: '285'
newvalue: docsCableScte55d2DsOob
- value: '286'
newvalue: docsCableScte55d2UsOob
- value: '287'
newvalue: docsCableNdf
- value: '288'
newvalue: docsCableNdr
- value: '289'
newvalue: ptm
- value: '290'
newvalue: ghn
- uuid: 142fe822cc424a76899551b6f29799d9
name: 'Service state'
mappings:
- value: '0'
newvalue: Down
- value: '1'
newvalue: Up
- uuid: 939c7551b81e40e9b053e624211d0901
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: a9633d3df8724c7cba6dfc6ec790c1fd
expression: '(last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.uptime)>0 and last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.uptime)<10m) or (last(/Cisco Catalyst 3750V2-24PS by SNMP/system.hw.uptime)=0 and last(/Cisco Catalyst 3750V2-24PS by SNMP/system.net.uptime)<10m)'
name: 'Cisco Catalyst 3750V2-24PS: Host has been restarted'
event_name: 'Cisco Catalyst 3750V2-24PS: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
tags:
- tag: scope
value: notice