7.2
792ac9730c4a468ebc50c88c7c6be996
Templates Datacom
b01bb96a1ed547e1a8770677a646aa3c
Templates IPv0
04b4e7eadd9c46abbfebe55b19f04858
IPv0 - Template Datacom DmOS
IPv0 - Template Datacom DmOS
Templates Datacom
Templates IPv0
-
2765daa8ac364b5cb3faf0e529c6f16a
ICMP Ping
SIMPLE
icmpping
90d
Service state
component
health
66697e8b3b474caabe583ce274bbda6e
max(/IPv0 - Template Datacom DmOS/icmpping,#3)=0
Unavailable by ICMP ping
HIGH
scope
availability
-
eff2fcb35e6b4335b575eb493f411ae9
ICMP Loss
SIMPLE
icmppingloss
90d
FLOAT
%
component
health
ab451c42608340e5a1fa12b04e2c1cd4
min(/IPv0 - Template Datacom DmOS/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/IPv0 - Template Datacom DmOS/icmppingloss,5m)<100
High ICMP ping loss
Loss: {ITEM.LASTVALUE1}
WARNING
Unavailable by ICMP ping
max(/IPv0 - Template Datacom DmOS/icmpping,#3)=0
scope
availability
scope
performance
-
72d625f790504e87a366c88f03a85895
ICMP Response Time
SIMPLE
icmppingsec
90d
FLOAT
s
component
health
054e448d8408489c9f1bcfaf609d6555
avg(/IPv0 - Template Datacom DmOS/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}
High ICMP ping response time
Value: {ITEM.LASTVALUE1}
WARNING
High ICMP ping loss
min(/IPv0 - Template Datacom DmOS/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/IPv0 - Template Datacom DmOS/icmppingloss,5m)<100
Unavailable by ICMP ping
max(/IPv0 - Template Datacom DmOS/icmpping,#3)=0
scope
availability
scope
performance
-
d56a379f28ed445ca90dbb851df7fa84
SNMP traps (fallback)
SNMP_TRAP
snmptrap.fallback
LOG
The item is used to collect all SNMP traps unmatched by other snmptrap items
hh:mm:sszyyyy/MM/dd
component
network
-
ce24d89fb5294c66883138ea54109f07
System Contact
SNMP_AGENT
get[SNMPv2-MIB::sysContact.0]
system.contact[sysContact.0]
60m
90d
CHAR
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
CONTACT
DISCARD_UNCHANGED_HEARTBEAT
12h
component
system
-
a8c78377193640008f90628a589cb5e8
System Description
SNMP_AGENT
get[SNMPv2-MIB::sysDescr.0]
system.descr[sysDescr.0]
60m
2w
CHAR
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software.
HARDWARE
DISCARD_UNCHANGED_HEARTBEAT
12h
component
system
-
cb4566e7156d4a8a979968b4f67db803
System Location
SNMP_AGENT
get[SNMPv2-MIB::sysLocation.0]
system.location[sysLocation.0]
60m
7d
CHAR
The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
LOCATION
DISCARD_UNCHANGED_HEARTBEAT
12h
component
system
-
2b346e21e238465882a7e87b5143b732
System Name
SNMP_AGENT
get[SNMPv2-MIB::sysName.0]
system.name[sysName.0]
60m
2w
CHAR
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
NAME
component
system
d1aba0aba2d74a969f7011a0af5f8037
last(/IPv0 - Template Datacom DmOS/system.name[sysName.0],#1)<>last(/IPv0 - Template Datacom DmOS/system.name[sysName.0],#2) and length(last(/IPv0 - Template Datacom DmOS/system.name[sysName.0]))>0
System name has changed
INFO
The name of the system has changed. Acknowledge to close the problem manually.
scope
notice
scope
security
-
4cec986521c844a992e7d4e296ac135a
System Object ID
SNMP_AGENT
1.3.6.1.2.1.1.2.0
system.objectid[sysObjectID.0]
15m
CHAR
DISCARD_UNCHANGED_HEARTBEAT
12h
component
system
-
fa09ba2e7e6348738999bae4ab364289
System Uptime
SNMP_AGENT
1.3.6.1.2.1.1.3.0
system.uptime[sysUpTime.0]
60m
7d
uptime
The time since the network management portion of the system was last re-initialized.
MULTIPLIER
0.01
component
system
e4be043358924668973829b91be80aba
(last(/IPv0 - Template Datacom DmOS/system.uptime[sysUpTime.0])>0 and last(/IPv0 - Template Datacom DmOS/system.uptime[sysUpTime.0])<10m) or (last(/IPv0 - Template Datacom DmOS/system.uptime[sysUpTime.0])=0 and last(/IPv0 - Template Datacom DmOS/system.uptime[sysUpTime.0])<10m)
Host has been restarted
{HOST.NAME} has been restarted (uptime < 10m)
WARNING
No SNMP data collection
max(/IPv0 - Template Datacom DmOS/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0
scope
notice
-
fd1aca7b64964d69850df529edb26946
SNMP Agent Availability
INTERNAL
zabbix[host,snmp,available]
7d
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
Possible values:
0 - not available
1 - available
2 - unknown
zabbix.host.available
component
system
7839aac59b8b457e950c8020a6822b93
max(/IPv0 - Template Datacom DmOS/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0
No SNMP data collection
WARNING
SNMP is not available for polling. Please check device connectivity and SNMP settings.
Unavailable by ICMP ping
max(/IPv0 - Template Datacom DmOS/icmpping,#3)=0
scope
availability
8781ccb1e01b437f94f0664a06941f49
SNMP Discovery - PSU
EXTERNAL
dmos_hardware_monitor_mib_psu.py["{HOST.CONN}", "{$SNMP_COMMUNITY}"]
60m
DISABLE_NEVER
0afc579e58ae47639f8b3110d06a477f
{#PSU_SLOT_NAME} Status
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::psuStatus.{#PSU_SLOT_NAME_LEN}.{#PSU_SLOT_NAME_DEC}]
psuStatus.[{#PSU_SLOT_NAME}]
5m
DmOS-HW-MONITOR-MIB PSU Status
Application
Hardware Monitor - PSU
2b62c859e48d4976ad947c45e870edc0
last(/IPv0 - Template Datacom DmOS/psuStatus.[{#PSU_SLOT_NAME}])<>0 and change(/IPv0 - Template Datacom DmOS/psuStatus.[{#PSU_SLOT_NAME}])>0
{HOST.NAME} PSU Status Failed: {#PSU_SLOT_NAME}
Current state: {ITEM.LASTVALUE1}
HIGH
{HOST.NAME} PSU Status Failed: {#PSU_SLOT_NAME}
Trigger activate if PSU Status is different from OK (0) and difference between previous Status and actual Status is upper then 0.
f4362dd3f8414e05a7eae2d1a13249ab
SNMP Discovery - Network Interfaces Discovery
SNMP_AGENT
discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]
net.if.discovery
1h
{#IFADMINSTATUS}
{$NET.IF.IFADMINSTATUS.MATCHES}
{#IFADMINSTATUS}
{$NET.IF.IFADMINSTATUS.NOT_MATCHES}
NOT_MATCHES_REGEX
{#IFALIAS}
{$NET.IF.IFALIAS.MATCHES}
{#IFALIAS}
{$NET.IF.IFALIAS.NOT_MATCHES}
NOT_MATCHES_REGEX
{#IFDESCR}
{$NET.IF.IFDESCR.MATCHES}
{#IFDESCR}
{$NET.IF.IFDESCR.NOT_MATCHES}
NOT_MATCHES_REGEX
{#IFNAME}
{$NET.IF.IFNAME.MATCHES}
{#IFNAME}
{$NET.IF.IFNAME.NOT_MATCHES}
NOT_MATCHES_REGEX
{#IFOPERSTATUS}
{$NET.IF.IFOPERSTATUS.MATCHES}
{#IFOPERSTATUS}
{$NET.IF.IFOPERSTATUS.NOT_MATCHES}
NOT_MATCHES_REGEX
{#IFTYPE}
{$NET.IF.IFTYPE.MATCHES}
{#IFTYPE}
{$NET.IF.IFTYPE.NOT_MATCHES}
NOT_MATCHES_REGEX
Discovering interfaces from IF-MIB.
f3340e49312f491da5e14ab37f22e532
Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded
SNMP_AGENT
1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}
net.if.in.discards[ifInDiscards.{#SNMPINDEX}]
3m
MIB: IF-MIB
The number of inbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
CHANGE_PER_SECOND
component
network
interface
{#IFNAME}
00ab5b76a7fd48a4ad5553b5eefa026f
Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors
SNMP_AGENT
1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}
net.if.in.errors[ifInErrors.{#SNMPINDEX}]
3m
MIB: IF-MIB
For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
CHANGE_PER_SECOND
component
network
interface
{#IFNAME}
a9581c3662404ba481d06ddcd5d0c554
Interface {#IFNAME}({#IFALIAS}): Bits received
SNMP_AGENT
1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}
net.if.in[ifHCInOctets.{#SNMPINDEX}]
3m
bps
MIB: IF-MIB
The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
CHANGE_PER_SECOND
MULTIPLIER
8
component
network
interface
{#IFNAME}
1b2eafab575d42cda071035ffc5321a8
Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded
SNMP_AGENT
1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}
net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]
3m
MIB: IF-MIB
The number of outbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
CHANGE_PER_SECOND
component
network
interface
{#IFNAME}
5e1ed90e871b4edf9d64ce5c940c140e
Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors
SNMP_AGENT
1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}
net.if.out.errors[ifOutErrors.{#SNMPINDEX}]
3m
MIB: IF-MIB
For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
CHANGE_PER_SECOND
component
network
interface
{#IFNAME}
c37f525026474c23b5beeade04369f55
Interface {#IFNAME}({#IFALIAS}): Bits sent
SNMP_AGENT
1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}
net.if.out[ifHCOutOctets.{#SNMPINDEX}]
3m
bps
MIB: IF-MIB
The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
CHANGE_PER_SECOND
MULTIPLIER
8
component
network
interface
{#IFNAME}
df681c05a7004430ad5699bf43744cda
Interface {#IFNAME}({#IFALIAS}): Speed
SNMP_AGENT
1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}
net.if.speed[ifHighSpeed.{#SNMPINDEX}]
5m
0
bps
MIB: IF-MIB
An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.
MULTIPLIER
1000000
DISCARD_UNCHANGED_HEARTBEAT
1h
component
network
interface
{#IFNAME}
7456c0f902b047398aa07de75aa26de1
Interface {#IFNAME}({#IFALIAS}): Operational status
SNMP_AGENT
1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}
net.if.status[ifOperStatus.{#SNMPINDEX}]
0
MIB: IF-MIB
The current operational state of the interface.
- The testing(3) state indicates that no operational packet scan be passed
- If ifAdminStatus is down(2) then ifOperStatus should be down(2)
- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic
- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)
- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state
- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.
IF-MIB::ifOperStatus
component
network
interface
{#IFNAME}
9c042fb9de884b50a80259616016722d
{$IFCONTROL:"{#IFNAME}"}=1 and last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))
RECOVERY_EXPRESSION
last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0
Interface {#IFNAME}({#IFALIAS}): Link down
Current state: {ITEM.LASTVALUE1}
AVERAGE
This trigger expression works as follows:
1. It can be triggered if the operations status is down.
2. `{$IFCONTROL:"{#IFNAME}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is down.
3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for "eternal off" interfaces.)
WARNING: if closed manually - it will not fire again on the next poll, because of .diff.
YES
scope
availability
f4d4a3b2dfde4c97a7b7ad97298e95ab
Interface {#IFNAME}({#IFALIAS}): Interface type
SNMP_AGENT
1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}
net.if.type[ifType.{#SNMPINDEX}]
1h
0
MIB: IF-MIB
The type of interface.
Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA),
through updating the syntax of the IANAifType textual convention.
IF-MIB::ifType
DISCARD_UNCHANGED_HEARTBEAT
1d
component
network
interface
{#IFNAME}
763cbe562ea14bd9bb3f88be5ca2d7c9
change(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
and (
last(/IPv0 - Template Datacom DmOS/net.if.type[ifType.{#SNMPINDEX}])=6 or
last(/IPv0 - Template Datacom DmOS/net.if.type[ifType.{#SNMPINDEX}])=7 or
last(/IPv0 - Template Datacom DmOS/net.if.type[ifType.{#SNMPINDEX}])=11 or
last(/IPv0 - Template Datacom DmOS/net.if.type[ifType.{#SNMPINDEX}])=62 or
last(/IPv0 - Template Datacom DmOS/net.if.type[ifType.{#SNMPINDEX}])=69 or
last(/IPv0 - Template Datacom DmOS/net.if.type[ifType.{#SNMPINDEX}])=117
)
and
(last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
RECOVERY_EXPRESSION
(change(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
(last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before
Current reported speed: {ITEM.LASTVALUE1}
INFO
This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually.
YES
Interface {#IFNAME}({#IFALIAS}): Link down
{$IFCONTROL:"{#IFNAME}"}=1 and last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))
last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0
scope
performance
b6b21d02d74d454b8936fbfc7c4db86d
(avg(/IPv0 - Template Datacom DmOS/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
avg(/IPv0 - Template Datacom DmOS/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
last(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
RECOVERY_EXPRESSION
avg(/IPv0 - Template Datacom DmOS/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
avg(/IPv0 - Template Datacom DmOS/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/IPv0 - Template Datacom DmOS/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
Interface {#IFNAME}({#IFALIAS}): High bandwidth usage
Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)
In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}
WARNING
The utilization of the network interface is close to its estimated maximum bandwidth.
YES
Interface {#IFNAME}({#IFALIAS}): Link down
{$IFCONTROL:"{#IFNAME}"}=1 and last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))
last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0
scope
performance
f59d7ea314364649a5022cc095ac9871
min(/IPv0 - Template Datacom DmOS/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
or min(/IPv0 - Template Datacom DmOS/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
RECOVERY_EXPRESSION
max(/IPv0 - Template Datacom DmOS/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
and max(/IPv0 - Template Datacom DmOS/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
Interface {#IFNAME}({#IFALIAS}): High error rate
Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)
errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}
WARNING
It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.
YES
Interface {#IFNAME}({#IFALIAS}): Link down
{$IFCONTROL:"{#IFNAME}"}=1 and last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))
last(/IPv0 - Template Datacom DmOS/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0
scope
availability
scope
performance
6b159eb7d128485bbcf460eb52627800
Interface {#IFNAME}({#IFALIAS}): Network traffic
1A7C11
-
IPv0 - Template Datacom DmOS
net.if.in[ifHCInOctets.{#SNMPINDEX}]
1
FF0000
-
IPv0 - Template Datacom DmOS
net.if.out[ifHCOutOctets.{#SNMPINDEX}]
2
00611C
-
IPv0 - Template Datacom DmOS
net.if.in.discards[ifInDiscards.{#SNMPINDEX}]
3
F7941D
-
IPv0 - Template Datacom DmOS
net.if.in.errors[ifInErrors.{#SNMPINDEX}]
4
FC6EA3
-
IPv0 - Template Datacom DmOS
net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]
5
6C59DC
-
IPv0 - Template Datacom DmOS
net.if.out.errors[ifOutErrors.{#SNMPINDEX}]
Discovery only UP
1
{#IFADMINSTATUS}
^2$
LIKE
Bits
DISCOVER
LIKE
Inbound packets
DISCOVER
LIKE
Interface type
DISCOVER
LIKE
Interface type
DISCOVER
LIKE
Outbound packets
DISCOVER
LIKE
Speed
DISCOVER
497ca11cdfe045478f4ce7c507706db7
SNMP Discovery - CPU Cores
SNMP_AGENT
discovery[{#SNMPVALUE},DMOS-SYSMON-MIB::cpuCoreFiveSecondsActive]
snmp.discovery.cpu.cores
60m
30d
DISABLE_NEVER
d425164ca5fd4c7c95c9b61a1fbca3ac
Active CPU core last 5 minutes
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreFiveMinutesActive.{#SNMPINDEX}]
cpuCoreFiveMinutesActive[{#SNMPINDEX}]
5m
7d
7d
%
Application
System Monitor
75c16218ff6041b393a27e98baabc581
last(/IPv0 - Template Datacom DmOS/cpuCoreFiveMinutesActive[{#SNMPINDEX}])>{$CPU.UTIL.CRIT}
{HOST.NAME} CPU Core High Usage > {$CPU.UTIL.CRIT}% for 5 minutes
WARNING
{HOST.NAME} CPU Core usage greater than{$CPU.UTIL.CRIT}%
4c82ea7891164188b8a893409b3e6624
Interrupt CPU core last 5 minutes
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreFiveMinutesInterrupt.{#SNMPINDEX}]
cpuCoreFiveMinutesInterrupt[{#SNMPINDEX}]
5m
7d
7d
%
Application
System Monitor
8eb94622bea6455ba90d9256a42ffbf5
Nice CPU core last 5 minutes
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreFiveMinutesNice.{#SNMPINDEX}]
cpuCoreFiveMinutesNIce[{#SNMPINDEX}]
5m
7d
7d
%
Application
System Monitor
70c855761b6d40ea945d8ab544bb381b
Softirq CPU core last 5 minutes
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreFiveMinutesSoftirq.{#SNMPINDEX}]
cpuCoreFiveMinutesSoftirq[{#SNMPINDEX}]
5m
7d
7d
%
Application
System Monitor
87a2922cd98146e7b4792b3bfed137e6
System CPU core last 5 minutes
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreFiveMinutesSystem.{#SNMPINDEX}]
cpuCoreFiveMinutesSystem[{#SNMPINDEX}]
5m
7d
7d
%
Application
System Monitor
8880f07efc224b9098fda8fcd7f42e9b
User CPU core last 5 minutes
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreFiveMinutesUser.{#SNMPINDEX}]
cpuCoreFiveMinutesUser[{#SNMPINDEX}]
5m
7d
7d
%
Application
System Monitor
4677d7a6578b4210af034aabdb4f722a
Wait CPU core last 5 minutes
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreFiveMinutesWait.{#SNMPINDEX}]
cpuCoreFiveMinutesWait[{#SNMPINDEX}]
5m
7d
7d
%
Application
System Monitor
6ee169d676634ceb931b3653a34b00e0
Active CPU core last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreOneMinuteActive.{#SNMPINDEX}]
cpuCoreOneMinuteActive[{#SNMPINDEX}]
7d
7d
%
Application
System Monitor
d19fa4d84b324af0b56cbec085da18d2
Interrupt CPU core last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreOneMinuteInterrupt.{#SNMPINDEX}]
cpuCoreOneMinuteInterrupt[{#SNMPINDEX}]
7d
7d
%
Application
System Monitor
b712106b3d874697aa9ba017328ed3f9
Nice CPU core last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreOneMinuteNice.{#SNMPINDEX}]
cpuCoreOneMinuteNice[{#SNMPINDEX}]
7d
7d
%
Application
System Monitor
387678e873784a2685ff39fb7d6e0671
Softirq CPU core last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreOneMinuteSoftirq.{#SNMPINDEX}]
cpuCoreOneMinuteSoftirq[{#SNMPINDEX}]
7d
7d
%
Application
System Monitor
0d23da3115e04edfadb93dbc8dbd4074
System CPU core last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreOneMinuteSystem.{#SNMPINDEX}]
cpuCoreOneMinuteSystem[{#SNMPINDEX}]
7d
7d
%
Application
System Monitor
7255a1e0e1b14d77a4b5ea0b1b1bd57d
User CPU core last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreOneMinuteUser.{#SNMPINDEX}]
cpuCoreOneMinuteUser[{#SNMPINDEX}]
7d
7d
%
Application
System Monitor
2220b967556f44c5833c9dccd0d73ba5
Wait CPU core last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuCoreOneMinuteWait.{#SNMPINDEX}]
cpuCoreOneMinuteWait[{#SNMPINDEX}]
7d
7d
%
Application
System Monitor
8619ccdb079b4d00badf8927010195e6
CPU Core {#SNMPINDEX} Last 1 Minute
1A7C11
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreOneMinuteActive[{#SNMPINDEX}]
2
2774A4
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreOneMinuteInterrupt[{#SNMPINDEX}]
3
A54F10
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreOneMinuteNice[{#SNMPINDEX}]
4
FC6EA3
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreOneMinuteSoftirq[{#SNMPINDEX}]
5
6C59DC
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreOneMinuteSystem[{#SNMPINDEX}]
6
AC8C14
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreOneMinuteUser[{#SNMPINDEX}]
7
611F27
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreOneMinuteWait[{#SNMPINDEX}]
7e686e4ff06a49e7ae6bdeb500dada90
CPU Core {#SNMPINDEX} Last 5 Minutes
1A7C11
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreFiveMinutesActive[{#SNMPINDEX}]
2
2774A4
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreFiveMinutesInterrupt[{#SNMPINDEX}]
3
A54F10
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreFiveMinutesNIce[{#SNMPINDEX}]
4
FC6EA3
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreFiveMinutesSoftirq[{#SNMPINDEX}]
5
6C59DC
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreFiveMinutesSystem[{#SNMPINDEX}]
6
AC8C14
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreFiveMinutesUser[{#SNMPINDEX}]
7
611F27
MAX
-
IPv0 - Template Datacom DmOS
cpuCoreFiveMinutesWait[{#SNMPINDEX}]
3417e77804a649458175d4ab1afaff8a
SNMP Discovery - CPU Load
SNMP_AGENT
discovery[{#SNMPVALUE},DMOS-SYSMON-MIB::cpuLoadFiveSecondsActive]
snmp.discovery.cpu.load
60m
30d
DISABLE_NEVER
8c38a92260394f00bb4c3728ab064df8
Active CPU load last 5 minutes
SNMP_AGENT
DMOS-SYSMON-MIB::cpuLoadFiveMinutesActive.{#SNMPINDEX}
cpuLoadFiveMinutesActive[{#SNMPINDEX}]
5m
7d
7d
%
Application
System Monitor
0cd0fa017d13494cb581834d2137ff2d
last(/IPv0 - Template Datacom DmOS/cpuLoadFiveMinutesActive[{#SNMPINDEX}])>{$CPU.UTIL.CRIT}
{HOST.NAME} CPU Load High Usage > {$CPU.UTIL.CRIT}% for 5 minutes
WARNING
{HOST.NAME} CPU Load usage greater than {$CPU.UTIL.CRIT}%
edd4ee08ada14c63bba64b8cf6e0e3f8
Active CPU load last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::cpuLoadOneMinuteActive.{#SNMPINDEX}]
cpuLoadOneMinuteActive[{#SNMPINDEX}]
7d
7d
%
Application
System Monitor
97f1cd08d3644f8d9089fd2b16b03f20
CPU Load {#SNMPINDEX} Last 1 Minute
1A7C11
MAX
-
IPv0 - Template Datacom DmOS
cpuLoadOneMinuteActive[{#SNMPINDEX}]
993d8663614241d689b3451a67b81a3b
CPU Load {#SNMPINDEX} Last 5 Minutes
1A7C11
MAX
-
IPv0 - Template Datacom DmOS
cpuLoadFiveMinutesActive[{#SNMPINDEX}]
8c2704b47f004e0eaa9341b096548132
SNMP Discovery - Fan
SNMP_AGENT
discovery[{#SNMPVALUE},DMOS-HW-MONITOR-MIB::fanDescription]
snmp.discovery.fan
60m
30d
DISABLE_NEVER
b640b93280334bc79cd175a5e731123a
FAN {#SNMPVALUE} Description
SNMP_AGENT
DMOS-HW-MONITOR-MIB::fanDescription.{#SNMPINDEX}
fanDescription[{#SNMPINDEX}]
5m
7d
TEXT
Application
Hardware Monitor - FAN
4483b53c449349129076f5b186b2f974
FAN {#SNMPVALUE} Read Error
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::fanSpeedReadError.{#SNMPINDEX}]
fanSpeedReadError[{#SNMPINDEX}]
5m
7d
DmOS-HW-MONITOR Read Error
Application
Hardware Monitor - FAN
f7ec72af1b3143ca95b6eeb463e76009
last(/IPv0 - Template Datacom DmOS/fanSpeedReadError[{#SNMPINDEX}])<>2
{HOST.NAME} FAN {#SNMPVALUE} Read Error
Current state: {ITEM.LASTVALUE1}
HIGH
acaa219e10f94f0da737df2a8b6c557d
FAN {#SNMPVALUE} Status
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::fanSpeedStatus.{#SNMPINDEX}]
fanSpeedStatus[{#SNMPINDEX}]
5m
7d
DmOS-HW-MONITOR Environment Sensor Status
Application
Hardware Monitor - FAN
075046aa5b1d4f76beb1d32439a444d1
last(/IPv0 - Template Datacom DmOS/fanSpeedStatus[{#SNMPINDEX}])<>0
{HOST.NAME} FAN {#SNMPVALUE} Status Error
Current state: {ITEM.LASTVALUE1}
HIGH
f70ea9b4aca44ccbadbbdd954f58e472
FAN {#SNMPVALUE} Speed
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::fanSpeed.{#SNMPINDEX}]
fanSpeed[{#SNMPINDEX}]
5m
7d
RPM
Application
Hardware Monitor - FAN
41e7d85fab954537adcbd26245ff6d55
FAN {#SNMPVALUE} Speed
1A7C11
-
IPv0 - Template Datacom DmOS
fanSpeed[{#SNMPINDEX}]
3f129d0c84a945a1a9060150421449fc
SNMP Discovery - Memory
SNMP_AGENT
discovery[{#SNMPVALUE},DMOS-SYSMON-MIB::memoryFiveSecondsTotal]
snmp.discovery.memory
60m
30d
DISABLE_NEVER
18c38f1eed0b4ea8bbe14f0a4aee34c1
Available memory last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::memoryOneMinuteAvailable.{#SNMPINDEX}]
memoryOneMinuteAvailable[{#SNMPINDEX}]
7d
Application
System Monitor
9c05ea5f2d44445b805edd3ac16a9012
last(/IPv0 - Template Datacom DmOS/memoryOneMinuteAvailable[{#SNMPINDEX}])<100000000
{HOST.NAME} - Memory Available Low < 100MB
HIGH
4f67c77be44a4ff49df011cd836e08a7
Buffered memory last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::memoryOneMinuteBuffered.{#SNMPINDEX}]
memoryOneMinuteBuffered[{#SNMPINDEX}]
7d
Application
System Monitor
d8f35e1e26054220b2b1aae3a5bb83cd
Cached memory last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::memoryOneMinuteCached.{#SNMPINDEX}]
memoryOneMinuteCached[{#SNMPINDEX}]
7d
Application
System Monitor
a6396242883d41eab6b92005458d4cb0
Free memory last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::memoryOneMinuteFree.{#SNMPINDEX}]
memoryOneMinuteFree[{#SNMPINDEX}]
7d
Application
System Monitor
2fa91c36e62f4cf28fc03e40dfd95c41
Slab Reclaimed last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::memoryOneMinuteSlabRecl.{#SNMPINDEX}]
memoryOneMinuteSlabRecl[{#SNMPINDEX}]
7d
Application
System Monitor
f44038ad93124f3aa19039d9c6932e8d
Slab Unreclaimed last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::memoryOneMinuteSlabUnrecl.{#SNMPINDEX}]
memoryOneMinuteSlabUnrecl[{#SNMPINDEX}]
7d
Application
System Monitor
34a375b6375c4a77bca2892ef1849c4c
Total memory last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::memoryOneMinuteTotal.{#SNMPINDEX}]
memoryOneMinuteTotal[{#SNMPINDEX}]
7d
Application
System Monitor
dd30430f63584000b8de13f5d729ed33
Used memory last 1 minute
SNMP_AGENT
get[DMOS-SYSMON-MIB::memoryOneMinuteUsed.{#SNMPINDEX}]
memoryOneMinuteUsed[{#SNMPINDEX}]
7d
Application
System Monitor
03bf8c98531d413d881d75738a9c9014
Memory Status {#SNMPINDEX} Last 1 minute
FILLED_REGION
1A7C11
-
IPv0 - Template Datacom DmOS
memoryOneMinuteAvailable[{#SNMPINDEX}]
1
F63100
-
IPv0 - Template Datacom DmOS
memoryOneMinuteBuffered[{#SNMPINDEX}]
2
2774A4
-
IPv0 - Template Datacom DmOS
memoryOneMinuteCached[{#SNMPINDEX}]
3
A54F10
-
IPv0 - Template Datacom DmOS
memoryOneMinuteFree[{#SNMPINDEX}]
4
FC6EA3
-
IPv0 - Template Datacom DmOS
memoryOneMinuteSlabRecl[{#SNMPINDEX}]
5
6C59DC
-
IPv0 - Template Datacom DmOS
memoryOneMinuteSlabUnrecl[{#SNMPINDEX}]
6
AC8C14
-
IPv0 - Template Datacom DmOS
memoryOneMinuteTotal[{#SNMPINDEX}]
7
611F27
-
IPv0 - Template Datacom DmOS
memoryOneMinuteUsed[{#SNMPINDEX}]
a748d181500d49cd8b26957ae9e002cf
SNMP Discovery - Temperature Sensor
SNMP_AGENT
discovery[{#SNMPVALUE},DMOS-HW-MONITOR-MIB::temperatureSensorDescription]
snmp.discovery.temp.sensor
60m
30d
DISABLE_NEVER
ca773e6f8f014dd799bec37d90524c56
Sensor {#SNMPVALUE} - Current Temperature
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::temperatureSensorCurrentTemperature.{#SNMPINDEX}]
temperatureSensorCurrentTemperature[{#SNMPINDEX}]
5m
7d
FLOAT
ºC
MULTIPLIER
0.1
Application
Hardware Monitor - Sensors
1afc6eaf1a8d49e4be22ffa64fca0316
Sensor {#SNMPVALUE} - Description
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::temperatureSensorDescription.{#SNMPINDEX}]
temperatureSensorDescription[{#SNMPINDEX}]
5m
7d
TEXT
Application
Hardware Monitor - Sensors
b7e6200e649c4f73aa9e17573f377db3
Sensor {#SNMPVALUE} - Hysteresis Temperature
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::temperatureSensorHysteresis.{#SNMPINDEX}]
temperatureSensorHysteresis[{#SNMPINDEX}]
5m
7d
FLOAT
ºC
MULTIPLIER
0.1
Application
Hardware Monitor - Sensors
cbdec5f67f12445eb767e7bb5a5231c0
Sensor {#SNMPVALUE} - Max Temperature
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::temperatureSensorMaxTemperature.{#SNMPINDEX}]
temperatureSensorMaxTemperature[{#SNMPINDEX}]
5m
7d
FLOAT
ºC
MULTIPLIER
0.1
Application
Hardware Monitor - Sensors
18748bf413134696827fbe0d3489dc71
Sensor {#SNMPVALUE} - Min Temperature
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::temperatureSensorMinTemperature.{#SNMPINDEX}]
temperatureSensorMinTemperature[{#SNMPINDEX}]
5m
7d
FLOAT
ºC
MULTIPLIER
0.1
Application
Hardware Monitor - Sensors
a606aa4151a44280b3c64b5d7a795126
Sensor {#SNMPVALUE} - Read Error
SNMP_AGENT
get[DMOS-HW-MONITOR-MIB::temperatureSensorTemperatureReadError.{#SNMPINDEX}]
temperatureSensorTemperatureReadError[{#SNMPINDEX}]
5m
7d
DmOS-HW-MONITOR Read Error
Application
Hardware Monitor - Sensors
a9647288798a4246b5d63c2cb496d5a8
Sensor {#SNMPVALUE} Temperature
1A7C11
-
IPv0 - Template Datacom DmOS
temperatureSensorCurrentTemperature[{#SNMPINDEX}]
1
F63100
-
IPv0 - Template Datacom DmOS
temperatureSensorMaxTemperature[{#SNMPINDEX}]
2
2774A4
-
IPv0 - Template Datacom DmOS
temperatureSensorMinTemperature[{#SNMPINDEX}]
vendor
datacom
{$CPU.UTIL.CRIT}
80
{$FAN_CRIT_STATUS}
2
{$ICMP_LOSS_WARN}
20
Warning threshold of ICMP packet loss in %.
{$ICMP_RESPONSE_TIME_WARN}
0.15
Warning threshold of the average ICMP response time in seconds.
{$IF.ERRORS.WARN}
2
Warning threshold of error packet rate. Can be used with interface name as context.
{$IF.UTIL.MAX}
90
{$IFCONTROL}
1
{$MEMORY.UTIL.MAX}
90
{$NET.IF.IFADMINSTATUS.MATCHES}
^.*
{$NET.IF.IFADMINSTATUS.NOT_MATCHES}
^2$
Ignore down(2) administrative status
{$NET.IF.IFALIAS.MATCHES}
.*
{$NET.IF.IFALIAS.NOT_MATCHES}
CHANGE_IF_NEEDED
{$NET.IF.IFDESCR.MATCHES}
.*
{$NET.IF.IFDESCR.NOT_MATCHES}
CHANGE_IF_NEEDED
{$NET.IF.IFNAME.MATCHES}
^.*$
{$NET.IF.IFNAME.NOT_MATCHES}
(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})
Filter out loopbacks, nulls, docker veth links and docker0 bridge by default
{$NET.IF.IFOPERSTATUS.MATCHES}
^u|^1
^.*$
{$NET.IF.IFOPERSTATUS.NOT_MATCHES}
^6$
Ignore notPresent(6)
{$NET.IF.IFTYPE.MATCHES}
.*
{$NET.IF.IFTYPE.NOT_MATCHES}
CHANGE_IF_NEEDED
{$SNMP.TIMEOUT}
5m
Time interval for the SNMP availability trigger.
{$TEMP_CRIT}
60
{$TEMP_CRIT_LOW}
5
{$TEMP_WARN}
50
d75105010fe14ca6949bedf4bfd89c35
Network interfaces
graphprototype
1
48
5
INTEGER
columns
1
GRAPH_PROTOTYPE
graphid.0
IPv0 - Template Datacom DmOS
Interface {#IFNAME}({#IFALIAS}): Network traffic
STRING
reference
KQCBS
61a9def2b1854feab2ae283cc7daca66
DmOS-HW-MONITOR-MIB PSU Status
0
Ok
1
Power Input Failure
2
Fuse Failure
3
Error
927905922b554d999fba1fc187ce8fd0
DmOS-HW-MONITOR Environment Sensor Status
-1
Error
-2
Fail
0
Normal
1
High
2
Low
3
Critical
1c0a3fbf84584efb9d68fd78ca7bfa47
DmOS-HW-MONITOR Read Error
1
Abnormal
2
Normal
32bbd300ad2f4329a080d67b8980a68d
IF-MIB::ifOperStatus
1
up
2
down
4
unknown
5
dormant
6
notPresent
7
lowerLayerDown
b2bf5f0e9c8243ce94dc640bc94bdc28
IF-MIB::ifType
1
other
2
regular1822
3
hdh1822
4
ddnX25
5
rfc877x25
6
ethernetCsmacd
7
iso88023Csmacd
8
iso88024TokenBus
9
iso88025TokenRing
10
iso88026Man
11
starLan
12
proteon10Mbit
13
proteon80Mbit
14
hyperchannel
15
fddi
16
lapb
17
sdlc
18
ds1
19
e1
20
basicISDN
21
primaryISDN
22
propPointToPointSerial
23
ppp
24
softwareLoopback
25
eon
26
ethernet3Mbit
27
nsip
28
slip
29
ultra
30
ds3
31
sip
32
frameRelay
33
rs232
34
para
35
arcnet
36
arcnetPlus
37
atm
38
miox25
39
sonet
40
x25ple
41
iso88022llc
42
localTalk
43
smdsDxi
44
frameRelayService
45
v35
46
hssi
47
hippi
48
modem
49
aal5
50
sonetPath
51
sonetVT
52
smdsIcip
53
propVirtual
54
propMultiplexor
55
ieee80212
56
fibreChannel
57
hippiInterface
58
frameRelayInterconnect
59
aflane8023
60
aflane8025
61
cctEmul
62
fastEther
63
isdn
64
v11
65
v36
66
g703at64k
67
g703at2mb
68
qllc
69
fastEtherFX
70
channel
71
ieee80211
72
ibm370parChan
73
escon
74
dlsw
75
isdns
76
isdnu
77
lapd
78
ipSwitch
79
rsrb
80
atmLogical
81
ds0
82
ds0Bundle
83
bsc
84
async
85
cnr
86
iso88025Dtr
87
eplrs
88
arap
89
propCnls
90
hostPad
91
termPad
92
frameRelayMPI
93
x213
94
adsl
95
radsl
96
sdsl
97
vdsl
98
iso88025CRFPInt
99
myrinet
100
voiceEM
101
voiceFXO
102
voiceFXS
103
voiceEncap
104
voiceOverIp
105
atmDxi
106
atmFuni
107
atmIma
108
pppMultilinkBundle
109
ipOverCdlc
110
ipOverClaw
111
stackToStack
112
virtualIpAddress
113
mpc
114
ipOverAtm
115
iso88025Fiber
116
tdlc
117
gigabitEthernet
118
hdlc
119
lapf
120
v37
121
x25mlp
122
x25huntGroup
123
trasnpHdlc
124
interleave
125
fast
126
ip
127
docsCableMaclayer
128
docsCableDownstream
129
docsCableUpstream
130
a12MppSwitch
131
tunnel
132
coffee
133
ces
134
atmSubInterface
135
l2vlan
136
l3ipvlan
137
l3ipxvlan
138
digitalPowerline
139
mediaMailOverIp
140
dtm
141
dcn
142
ipForward
143
msdsl
144
ieee1394
145
if-gsn
146
dvbRccMacLayer
147
dvbRccDownstream
148
dvbRccUpstream
149
atmVirtual
150
mplsTunnel
151
srp
152
voiceOverAtm
153
voiceOverFrameRelay
154
idsl
155
compositeLink
156
ss7SigLink
157
propWirelessP2P
158
frForward
159
rfc1483
160
usb
161
ieee8023adLag
162
bgppolicyaccounting
163
frf16MfrBundle
164
h323Gatekeeper
165
h323Proxy
166
mpls
167
mfSigLink
168
hdsl2
169
shdsl
170
ds1FDL
171
pos
172
dvbAsiIn
173
dvbAsiOut
174
plc
175
nfas
176
tr008
177
gr303RDT
178
gr303IDT
179
isup
180
propDocsWirelessMaclayer
181
propDocsWirelessDownstream
182
propDocsWirelessUpstream
183
hiperlan2
184
propBWAp2Mp
185
sonetOverheadChannel
186
digitalWrapperOverheadChannel
187
aal2
188
radioMAC
189
atmRadio
190
imt
191
mvl
192
reachDSL
193
frDlciEndPt
194
atmVciEndPt
195
opticalChannel
196
opticalTransport
197
propAtm
198
voiceOverCable
199
infiniband
200
teLink
201
q2931
202
virtualTg
203
sipTg
204
sipSig
205
docsCableUpstreamChannel
206
econet
207
pon155
208
pon622
209
bridge
210
linegroup
211
voiceEMFGD
212
voiceFGDEANA
213
voiceDID
214
mpegTransport
215
sixToFour
216
gtp
217
pdnEtherLoop1
218
pdnEtherLoop2
219
opticalChannelGroup
220
homepna
221
gfp
222
ciscoISLvlan
223
actelisMetaLOOP
224
fcipLink
225
rpr
226
qam
227
lmp
228
cblVectaStar
229
docsCableMCmtsDownstream
230
adsl2
231
macSecControlledIF
232
macSecUncontrolledIF
233
aviciOpticalEther
234
atmbond
235
voiceFGDOS
236
mocaVersion1
237
ieee80216WMAN
238
adsl2plus
239
dvbRcsMacLayer
240
dvbTdm
241
dvbRcsTdma
242
x86Laps
243
wwanPP
244
wwanPP2
245
voiceEBS
246
ifPwType
247
ilan
248
pip
249
aluELP
250
gpon
251
vdsl2
252
capwapDot11Profile
253
capwapDot11Bss
254
capwapWtpVirtualRadio
255
bits
256
docsCableUpstreamRfPort
257
cableDownstreamRfPort
258
vmwareVirtualNic
259
ieee802154
260
otnOdu
261
otnOtu
262
ifVfiType
263
g9981
264
g9982
265
g9983
266
aluEpon
267
aluEponOnu
268
aluEponPhysicalUni
269
aluEponLogicalLink
270
aluGponOnu
271
aluGponPhysicalUni
272
vmwareNicTeam
277
docsOfdmDownstream
278
docsOfdmaUpstream
279
gfast
280
sdci
281
xboxWireless
282
fastdsl
283
docsCableScte55d1FwdOob
284
docsCableScte55d1RetOob
285
docsCableScte55d2DsOob
286
docsCableScte55d2UsOob
287
docsCableNdf
288
docsCableNdr
289
ptm
290
ghn
77c84b431ba249519bb22ee9127f7e1e
Service state
0
Down
1
Up
1823ffcbb52b41c6805672ae68bb27ad
zabbix.host.available
0
not available
1
available
2
unknown
af057492d8b14ce1bc5d972a38b30100
Uptime
NO
NO
00BB00
-
IPv0 - Template Datacom DmOS
system.uptime[sysUpTime.0]