Files
templates-default/DELL_PowerEdge_R820_by_SNMP.yaml
T

2609 lines
117 KiB
YAML

zabbix_export:
version: '7.0'
template_groups:
- uuid: e960332b3f6c46a1956486d4f3f99fce
name: 'Templates/Server hardware'
templates:
- uuid: d41c5d0fa91545d68cced1b5dabe4bf1
template: 'DELL PowerEdge R820 by SNMP'
name: 'DELL PowerEdge R820 by SNMP'
description: |
Template for DELL PowerEdge R820 servers with iDRAC version 7 and later.
MIBs used:
HOST-RESOURCES-MIB
IDRAC-MIB-SMIv2
SNMPv2-MIB
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-5
groups:
- name: 'Templates/Server hardware'
items:
- uuid: c3bd795316314dbf9cf1c21751358ba8
name: 'SNMP walk RAID controllers table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]'
key: dell.server.array.controller.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.'
tags:
- tag: component
value: raw
- uuid: 0d7f8134d9934125b0bde2e0392479e8
name: 'SNMP walk Battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]'
key: dell.server.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.'
tags:
- tag: component
value: raw
- uuid: cf0d3ec990d94f949157ea9c22ba37b0
name: 'BIOS version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]'
key: dell.server.bios.version
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the version name of the system BIOS.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: ca6fac1eee9f41d88df43b4e870e8e84
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: 'dell.server.contact[sysContact]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
Name and contact information of the contact person for the node. If not provided, the value is a zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: f146e9f2165d441a9a68091f750f20c0
name: 'SNMP walk Processor device tables'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]'
key: dell.server.cpu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.'
tags:
- tag: component
value: raw
- uuid: b738b9531e5049df8c31f1c37868f34f
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: 'dell.server.descr[sysDescr]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 63fa498031104fa8a418570334efe139
name: 'SNMP walk Physical disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]'
key: dell.server.disk.physical.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.'
tags:
- tag: component
value: raw
- uuid: 1c500e036b534567a62d1c9a2f912f43
name: 'SNMP walk Virtual disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]'
key: dell.server.disk.virtual.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.'
tags:
- tag: component
value: raw
- uuid: 00d4d1232f13434eb7ff10eb025da6c3
name: 'SNMP walk Cooling device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]'
key: dell.server.fan.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 7a4e5160d533407194d63d90f93352bd
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the firmware version of a remote access card.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: bf0330b9e03c40b3a8aa4f799ab4d677
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0'
name: 'Dell R820: Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 70068169a3b74328a803fcd2d69954ee
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]'
key: 'dell.server.hw.model[systemModelName]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the model name of the system.
inventory_link: MODEL
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: a3881855713847d286c3acd0de95a416
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the service tag of the system.
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 85fc427d143b4bd784fc851464e30c60
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0'
name: 'Dell R820: Device has been replaced'
event_name: 'Dell R820: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 2308ce0f18f249258d3b05a5d08e6a83
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
trends: '0'
units: uptime
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the power-up time of the system in seconds.
tags:
- tag: component
value: system
- uuid: 286a4143fb464b31bb5cd581e7458959
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: 'dell.server.location[sysLocation]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 190388551b5144c49a4afefe0347cdc0
name: 'Memory, total size'
type: CALCULATED
key: dell.server.memory.size.total
units: B
params: 'sum(last_foreach(//dell.server.memory.size[*]))'
description: 'Total memory amount on the device.'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: memory
triggers:
- uuid: d7121d536e9e472e84ed8521c66dc63b
expression: 'change(/DELL PowerEdge R820 by SNMP/dell.server.memory.size.total)>0'
name: 'Dell R820: Memory amount has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags:
- tag: scope
value: availability
- uuid: 6c3ef6e5744649d7ba41df2748c349d8
name: 'SNMP walk Memory device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]'
key: dell.server.memory.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: eccac199b19143c0b3e275d5dae16729
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: 'dell.server.name[sysName]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 34d5734804fd4e28960e76d85b26230b
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.name[sysName]))>0'
name: 'Dell R820: System name has changed'
event_name: 'Dell R820: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 868e51dcc9114c7991a1be641a0b634d
name: 'SNMP walk Network device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]'
key: dell.server.net.if.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 55193d35960a410abf32f903b3b04406
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]'
key: 'dell.server.net.uptime[snmpEngineTime]'
trends: '0'
units: uptime
description: |
MIB: SNMP-FRAMEWORK-MIB
The number of seconds since the value of the snmpEngineBoots object last changed.
tags:
- tag: component
value: system
- uuid: 3561ed916061452e8597b8265c7305f3
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: 'dell.server.objectid[sysObjectID]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1).
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 08921851e08f41859daf5cfe748eaff6
name: 'SNMP walk Power supply table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]'
key: dell.server.psu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.'
tags:
- tag: component
value: raw
- uuid: 148a893a9b1540619793d3608ff9fa29
name: 'SNMP walk Temperature sensor table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]'
key: dell.server.sensor.temp.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 3924d9aae3ac44b1b14d9c19204cbe2c
name: 'Overall system health status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]'
key: 'dell.server.status[globalSystemStatus]'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 4109ee28d6d54d568965c21fc147791c
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}'
name: 'Dell R820: System is in unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 126c5d57fecc4785b1f620c413c5dd12
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
name: 'Dell R820: System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for errors.'
tags:
- tag: scope
value: availability
- uuid: da0537de8fdb4cff88cd19ec031cf562
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}'
name: 'Dell R820: System status is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for warnings.'
dependencies:
- name: 'Dell R820: System status is in critical state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
tags:
- tag: scope
value: availability
- uuid: 168398f2c797467fb7830dce8a9510b9
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]'
key: 'dell.server.sw.os[systemOSName]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the name of the operating system that the host is running.
inventory_link: OS
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: b6a26d0134054b75b88dbcfcd3dc8d3c
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.sw.os[systemOSName]))>0'
name: 'Dell R820: Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 35bc6ebfbb5f48ac93941d91b197dec0
name: 'SNMP walk System battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]'
key: dell.server.system.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.'
tags:
- tag: component
value: raw
- uuid: 89a3a5f1edff45cba03191752f4c5935
name: 'SNMP walk Voltage probe table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]'
key: dell.server.voltage.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 2f33eafc892b487dba32aa46823eafd4
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: network
- uuid: 5dd178b40f28436db3c71a1dd50b8ea8
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
description: |
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
Possible values:
0 - not available
1 - available
2 - unknown
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 81826abcb02d45b089024c47892bc52f
expression: 'max(/DELL PowerEdge R820 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0'
name: 'Dell R820: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: dd11819fb5e34d60bd8d9c7b658a79ac
name: 'Array controller discovery'
type: DEPENDENT
key: array.discovery
delay: '0'
description: 'Array controller discovery.'
item_prototypes:
- uuid: 259703858717407585f403d886114af5
name: 'Controller [{#CNTLR_NAME}]: Model'
type: DEPENDENT
key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The controller's name as represented in Storage Management.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
- uuid: 1aed396b98904eb49c2a4089841dac10
name: 'Controller [{#CNTLR_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the controller itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
trigger_prototypes:
- uuid: dfe26fe9fe2d4cbfa48ac3e65fee1b95
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
name: 'Dell R820: Controller [{#CNTLR_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R820: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
- uuid: 2d8e50f7be4e49da9c3e014393c07333
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
name: 'Dell R820: Controller [{#CNTLR_NAME}]: Unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 9e70c7098eb24c62926abc8a88d66643
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
name: 'Dell R820: Controller [{#CNTLR_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R820: Controller [{#CNTLR_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
- name: 'Dell R820: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.array.controller.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38
- '0'
- '{#CNTLR_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 161ef832d536461f90f47e914cdcbe44
name: 'Battery discovery'
type: DEPENDENT
key: battery.discovery
delay: '0'
description: 'Battery discovery.'
item_prototypes:
- uuid: acea5c462a964f0fb371db6a5fbb7bbb
name: 'Battery [{#BATTERY_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Current state of battery.
Possible values:
1: The current state could not be determined.
2: The battery is operating normally.
3: The battery has failed and needs to be replaced.
4: The battery temperature is high or charge level is depleting.
5: The battery is missing or not detected.
6: The battery is undergoing the re-charge phase.
7: The battery voltage or charge level is below the threshold.
valuemap:
name: 'IDRAC-MIB-SMIv2::batteryState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.battery.walk
tags:
- tag: component
value: battery
- tag: component
value: diskarray
trigger_prototypes:
- uuid: cdc3002046db4124ab5396a832a31d33
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
name: 'Dell R820: Battery [{#BATTERY_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 0e80311a3cf04eb3b2119f4accbe8378
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
name: 'Dell R820: Battery [{#BATTERY_NAME}]: Not in optimal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R820: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
- name: 'Dell R820: Battery [{#BATTERY_NAME}]: Warning state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
tags:
- tag: scope
value: availability
- uuid: aa9dc7776f844a6fb414f3f1ec6df936
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
name: 'Dell R820: Battery [{#BATTERY_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R820: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#BATTERY_NUM}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1
- '0'
- '{#BATTERY_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: f7291777ed604b249f0ff1dcb5e824e9
name: 'CPU status discovery'
type: DEPENDENT
key: cpu.discovery
delay: '0'
description: 'CPU status discovery.'
item_prototypes:
- uuid: 550842e315774bd9b47b5d463f5a6f0e
name: 'CPU [{#CPU_FQDD}]: State'
type: DEPENDENT
key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the reading of the processor device status probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: 4a936613afb742aba3008630245d1a4b
expression: 'bitand(last(/DELL PowerEdge R820 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0'
name: 'Dell R820: CPU [{#CPU_FQDD}]: Reading error'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU probe reading flag is not `processorPresent`.
tags:
- tag: scope
value: availability
- uuid: 0082b3b5a4a14afca309c643a82d9ba0
name: 'CPU [{#CPU_FQDD}]: Status'
type: DEPENDENT
key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: 75a71a22dd4e4e18a6361475e951138d
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3'
name: 'Dell R820: CPU [{#CPU_FQDD}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.cpu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#CPU_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 9b755a619c074bd1a99737f1fbf97708
name: 'Fan discovery'
type: DEPENDENT
key: fan.discovery
delay: '0'
filter:
conditions:
- macro: '{#TYPE}'
value: '3'
formulaid: A
description: 'Fan discovery.'
item_prototypes:
- uuid: c505c8858ffc4cbca8f1719b93d6f0a6
name: 'Fan [{#FAN_DESCR}]: Speed'
type: DEPENDENT
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
delay: '0'
units: rpm
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`.
When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device.
When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
- uuid: bcf401ebc1294bcab14bc1c0003f3fb7
name: 'Fan [{#FAN_DESCR}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the cooling device.
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
trigger_prototypes:
- uuid: 48b46c8badaa486da4cbb4815bebd5d8
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
name: 'Dell R820: Fan [{#FAN_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit.'
tags:
- tag: scope
value: availability
- uuid: ad5ee26a70f0461d90ff13f2b4cc022b
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R820: Fan [{#FAN_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit.'
dependencies:
- name: 'Dell R820: Fan [{#FAN_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 0fb616bc58b8480893047514cf7425bf
name: 'Dell R820: Fan [{#FAN_DESCR}]: Speed'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
master_item:
key: dell.server.fan.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.5
- '0'
- '{#FAN_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.8
- '0'
- '{#TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.7
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 5909e149acca4eddad89d3a43cdec880
name: 'Memory discovery'
type: DEPENDENT
key: memory.discovery
delay: '0'
description: 'Memory discovery.'
item_prototypes:
- uuid: 6eefc7d8c0d14f96bed7d77ea2bb6022
name: 'Memory [{#SNMPVALUE}]: Size'
type: DEPENDENT
key: 'dell.server.memory.size[{#SNMPVALUE}]'
delay: '0'
units: B
description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- type: MULTIPLIER
parameters:
- '1024'
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
- uuid: 4cdb3a43a0d847318269db509abb5926
name: 'Memory [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.memory.status[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the memory device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
trigger_prototypes:
- uuid: 6fdceebb428e4961bc38c0f089eb8c16
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3'
name: 'Dell R820: Memory [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Memory status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.memory.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: ec7f3a6a75da48d69a5178a3acdeec2d
name: 'Network interface discovery'
type: DEPENDENT
key: net.if.discovery
delay: '0'
description: 'Discovery of network interfaces.'
item_prototypes:
- uuid: 71c070e0a1c7471989f2cebb89f1adcf
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status'
type: DEPENDENT
key: 'dell.server.net.if.link[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the connection status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: df1c4ad1e9a1481db69cee6ca8651674
expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R820 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R820 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0'
name: 'Dell R820: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is Down.
2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down.
3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.)
manual_close: 'YES'
tags:
- tag: scope
value: availability
- uuid: 15743aecf8f046559094380f25617c03
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status'
type: DEPENDENT
key: 'dell.server.net.if.status[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: 386e1c9194904163b6e42030e4ae357b
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3'
name: 'Dell R820: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Network interface status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.net.if.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#NIC_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1
- '0'
- '{#NIC_MAC}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1
- '2'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: df58f76c952a4dbf9556490168bd39de
name: 'Physical disk discovery'
type: DEPENDENT
key: physicaldisk.discovery
delay: '0'
description: 'Physical disk discovery.'
item_prototypes:
- uuid: 0d6e0fed749445afbe8a4e392e12abbe
name: 'Physical disk [{#DISK_NAME}]: Media type'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The media type of the physical disk. Possible Values:
1: The media type could not be determined.
2: Hard Disk Drive (HDD).
3: Solid State Drive (SSD).
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 6138dd1248e24a3d979947046e161a16
name: 'Physical disk [{#DISK_NAME}]: Model name'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The model number of the physical disk.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 838834fd85bb4abc888963e3d6633ac9
name: 'Physical disk [{#DISK_NAME}]: Serial number'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The physical disk's unique identification number from the manufacturer.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: ef809a7388a141009f0e955d2fd74913
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0'
name: 'Dell R820: Physical disk [{#DISK_NAME}] has been replaced'
event_name: 'Dell R820: [{#DISK_NAME}] has been replaced (new serial number received)'
priority: INFO
description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 43e78bf47b4d424b82ee69c5114fb002
name: 'Physical disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the physical disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: d5a1505bdab14808a818c3337010cdce
name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Indicates whether the physical disk has received a predictive failure alert.
valuemap:
name: 'IDRAC-MIB-SMIv2::BooleanType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: ef5b3157e92f4cd98b0b0ce19777a54e
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}'
name: 'Dell R820: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Disk probably requires replacement.'
dependencies:
- name: 'Dell R820: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
- uuid: 71d28a0808384915bf1f08bb8cdad3f6
name: 'Physical disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the physical disk itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 8f80413f2f694cd7a293b9345872c99a
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
name: 'Dell R820: Physical disk [{#DISK_NAME}]: Failed state'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check physical disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: 07beb08e93ba48aaa57d989d947a430e
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
name: 'Dell R820: Physical disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check physical disk for warnings or errors.'
dependencies:
- name: 'Dell R820: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 7d235725b2e24ef3843ec59f597e26c7
name: 'Dell R820: Physical disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.physical.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 1f4854fdfc9b4c1683a9c3b023373a83
name: 'PSU discovery'
type: DEPENDENT
key: psu.discovery
delay: '0'
description: 'PSU discovery.'
item_prototypes:
- uuid: fa618cb76eeb4f3495fe6dfa5f516104
name: 'Power supply [{#PSU_DESCR}]: State'
type: DEPENDENT
key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the status of the power supply.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.psu.walk
tags:
- tag: component
value: psu
trigger_prototypes:
- uuid: 260129e48fe24ba8af0b628c303d23a3
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
name: 'Dell R820: Power supply [{#PSU_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors.'
tags:
- tag: scope
value: availability
- uuid: 97957af2d68048879527882edf8bfe7e
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
name: 'Dell R820: Power supply [{#PSU_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors.'
dependencies:
- name: 'Dell R820: Power supply [{#PSU_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.psu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
- '0'
- '{#PSU_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 05262c1eb7af4bdfb9be4b87eb67c573
name: 'System battery discovery'
type: DEPENDENT
key: system.battery.discovery
delay: '0'
description: 'System battery discovery.'
item_prototypes:
- uuid: 7c35f1486da64a2880bdd9cafc0b4cf4
name: 'System battery [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.system.battery[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the battery.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.system.battery.walk
tags:
- tag: component
value: battery
trigger_prototypes:
- uuid: 77dfa584df524f6c9e5bfef9f44012f7
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3'
name: 'Dell R820: System battery [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
System battery status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.system.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 43c9a9c046b943e7aa257a86540aae22
name: 'Temperature discovery'
type: DEPENDENT
key: temp.discovery
delay: '0'
description: 'Temperature sensor discovery.'
item_prototypes:
- uuid: 24139838c42248f3b9d7f8244daacc0e
name: 'Probe [{#SENSOR_LOCALE}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the temperature probe.
Possible values:
other(1), -- probe status is not one of the following:
unknown(2), -- probe status is unknown (not known or monitored)
ok(3), -- probe is reporting a value within the thresholds
nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold
criticalUpper(5), -- probe has crossed the upper critical threshold
nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold
nonCriticalLower(7), -- probe has crossed the lower noncritical threshold
criticalLower(8), -- probe has crossed the lower critical threshold
nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold
failed(10) -- probe is not functional
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: bcc2ecc5b254457288547aacf59176eb
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
name: 'Dell R820: Probe [{#SENSOR_LOCALE}]: Critical status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: c53be3b3a911410896fcd2e94bed62e1
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
name: 'Dell R820: Probe [{#SENSOR_LOCALE}]: Not in optimal status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
manual_close: 'YES'
dependencies:
- name: 'Dell R820: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
- name: 'Dell R820: Probe [{#SENSOR_LOCALE}]: Warning status'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
tags:
- tag: scope
value: notice
- uuid: 365c6cbbee2440c2a62e4d5376058f0a
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R820: Probe [{#SENSOR_LOCALE}]: Warning status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R820: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R820 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
tags:
- tag: scope
value: availability
- uuid: ef279c5ff8694f28916f6bd0d9615089
name: 'Probe [{#SENSOR_LOCALE}]: Value'
type: DEPENDENT
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
units: °C
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`.
When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade.
When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.1'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
graph_prototypes:
- uuid: 17bc3aea55c443a2b04b1a23b8462e66
name: 'Dell R820: Probe [{#SENSOR_LOCALE}]: Value'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
master_item:
key: dell.server.sensor.temp.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
- '0'
- '{#SENSOR_LOCALE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 871e0b2895a141aab83c71eb0cb181a8
name: 'Virtual disk discovery'
type: DEPENDENT
key: virtualdisk.discovery
delay: '0'
description: 'Virtual disk discovery.'
item_prototypes:
- uuid: 57e6784821914279a1fe8d11f20ad66b
name: 'Virtual disk [{#DISK_NAME}]: Layout type'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The virtual disk's RAID type.
Possible values:
1: Not one of the following
2: RAID-0
3: RAID-1
4: RAID-5
5: RAID-6
6: RAID-10
7: RAID-50
8: RAID-60
9: Concatenated RAID 1
10: Concatenated RAID 5
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 882a140fafd340c8b888337c0ca051ad
name: 'Virtual disk [{#DISK_NAME}]: Read policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The read policy used by the controller for read operations on this virtual disk.
Possible values:
1: No Read Ahead.
2: Read Ahead.
3: Adaptive Read Ahead.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 56a908b58aff4639b0b6a53911619746
name: 'Virtual disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the virtual disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: cba60a18965843dba5bdadfdabfb1b83
name: 'Virtual disk [{#DISK_NAME}]: Operational state'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The state of the virtual disk when there are progressive operations ongoing.
Possible values:
1: There is no active operation running.
2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.
3: A Consistency Check (CC) is being performed on the virtual disk.
4: The virtual disk is being initialized.
5: BackGround Initialization (BGI) is being performed on the virtual disk.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 3m
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 7daf3f6a7af6490688d9800b6542590f
name: 'Virtual disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The current state of this virtual disk (which includes any member physical disks.)
Possible states:
1: The current state could not be determined.
2: The virtual disk is operating normally or optimally.
3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost.
4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.
The data on the virtual disk might no longer be fault tolerant.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
trigger_prototypes:
- uuid: 194a88954cb543d6aabf8c42839d22b7
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
name: 'Dell R820: Virtual disk [{#DISK_NAME}]: Failed state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the virtual disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: a7f94854f30b420d9aa00cbab12d8418
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
name: 'Dell R820: Virtual disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the virtual disk for warnings or errors.'
dependencies:
- name: 'Dell R820: Virtual disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
- uuid: e0b2638cf3dd4dd0809aa5b73101deea
name: 'Virtual disk [{#DISK_NAME}]: Write policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The write policy used by the controller for write operations on this virtual disk.
Possible values:
1: Write Through.
2: Write Back.
3: Force Write Back.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
graph_prototypes:
- uuid: b129721d9c064bec908414d69fd6173c
name: 'Dell R820: Virtual disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.virtual.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: b84ca44320644f46919c9535da909782
name: 'Voltage probe discovery'
type: DEPENDENT
key: voltage.discovery
delay: '0'
filter:
evaltype: AND
conditions:
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
formulaid: A
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
formulaid: C
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
description: 'Voltage probe discovery.'
item_prototypes:
- uuid: 2623885d4d204b3faae8037d1c1cc19b
name: 'Voltage probe [{#VPROBE_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.voltage.status[{#VPROBE_NAME}]'
delay: '0'
description: 'This attribute defines the status of the voltage probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
trigger_prototypes:
- uuid: b2c7a3c6ccc74b24a1261171038ef059
expression: 'last(/DELL PowerEdge R820 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3'
name: 'Dell R820: Voltage probe [{#VPROBE_NAME}]: Status is not OK'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device''s voltage.'
tags:
- tag: scope
value: availability
- uuid: 34887c269ced46e9bcf6108b83f0338f
name: 'Voltage probe [{#VPROBE_NAME}]: Voltage'
type: DEPENDENT
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
delay: '0'
value_type: FLOAT
units: V
description: 'This attribute defines the reading for a voltage probe.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.001'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
graph_prototypes:
- uuid: 37267e51adc1418c8f14ef391f719340
name: 'Dell R820: Voltage probe [{#VPROBE_NAME}]: Voltage'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
master_item:
key: dell.server.voltage.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#VPROBE_NAME}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1
- '0'
- '{#VPROBE_TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: class
value: hardware
- tag: target
value: dell
- tag: target
value: 'dell poweredge'
macros:
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
value: '^.*Voltage.*$'
description: 'Sets the regex string of voltage probe names to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe names to ignore in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
value: 18|16
description: 'Sets the regex string of voltage probe types to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe types to ignore in discovery.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
value: '3'
description: 'The critical status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
value: '2'
description: 'The OK status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
value: '5'
description: 'The critical status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
value: '6'
description: 'The disaster status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}'
value: '1'
description: 'The critical S.M.A.R.T status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}'
value: '5'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
value: '6'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
value: '10'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}'
value: '5'
description: 'The critical status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}'
value: '6'
description: 'The disaster status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}'
value: '4'
description: 'The warning status of health for the trigger expression.'
- macro: '{$DELL.SNMP.IFCONTROL}'
value: '1'
description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}'
value: '5'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
value: '6'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
value: '3'
description: 'The OK status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for the SNMP agent availability trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
value: '3'
description: 'The critical status of the virtual disk for the trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
value: '4'
description: 'The warning status of the virtual disk for the trigger expression.'
dashboards:
- uuid: 65209bf05b134cb2bc8e7e60e8bd747c
name: Overview
pages:
- name: Overview
display_period: '30'
widgets:
- type: item
name: 'System health'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'System Health'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.status[globalSystemStatus]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'Serial number'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'Serial number'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'HW model'
x: '36'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'HW model'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.hw.model[systemModelName]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: Firmware
x: '36'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: Firmware
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- name: Discoveries
display_period: '30'
widgets:
- type: honeycomb
name: 'Interface link'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'NIC*Link status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAA
- type: STRING
name: thresholds.0.color
value: 069C56
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: FF681E
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: 'Temperature sensors'
'y': '4'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Probe*Value'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAB
- type: INTEGER
name: secondary_label_decimal_places
value: '0'
- type: honeycomb
name: 'Physical disks'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Physical disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAC
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
- type: honeycomb
name: 'Power supplies'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Voltage probe*Voltage'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAE
- type: honeycomb
name: 'Virtual disks'
x: '36'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Virtual disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAD
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: Fans
x: '36'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Fan*Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAF
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
valuemaps:
- uuid: 1a2c68f0f2384c0da7027981bd4bb5be
name: 'IDRAC-MIB-SMIv2::batteryState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Ready
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- value: '5'
newvalue: Missing
- value: '6'
newvalue: Charging
- value: '7'
newvalue: 'Below threshold'
- uuid: 045512ecd6b94fbab71dd17abf5b8f4b
name: 'IDRAC-MIB-SMIv2::BooleanType'
mappings:
- value: '0'
newvalue: ok
- value: '1'
newvalue: failed
- uuid: 8a60520959be4ec5aa525f637beb8472
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
mappings:
- value: '0'
newvalue: unknown
- value: '1'
newvalue: connected
- value: '2'
newvalue: disconnected
- value: '3'
newvalue: driverBad
- value: '4'
newvalue: driverDisabled
- value: '10'
newvalue: hardwareInitalizing
- value: '11'
newvalue: hardwareResetting
- value: '12'
newvalue: hardwareClosing
- value: '13'
newvalue: hardwareNotReady
- uuid: 82b2ff6e115d4d098ae1025547853b4b
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: 168707d69c984df4837638c72f103749
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: 1f138e6846544243a2729b41be9a97aa
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: HDD
- value: '3'
newvalue: SSD
- uuid: 7ad96a534bc84f32afd6ae59011db2a0
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
mappings:
- value: '1'
newvalue: internalError
- value: '2'
newvalue: thermalTrip
- value: '32'
newvalue: configurationError
- value: '128'
newvalue: processorPresent
- value: '256'
newvalue: processorDisabled
- value: '512'
newvalue: terminatorPresent
- value: '1024'
newvalue: processorThrottled
- uuid: 9d25c114ba8046f5b126be9111d95184
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCriticalUpper
- value: '5'
newvalue: criticalUpper
- value: '6'
newvalue: nonRecoverableUpper
- value: '7'
newvalue: nonCriticalLower
- value: '8'
newvalue: criticalLower
- value: '9'
newvalue: nonRecoverableLower
- value: '10'
newvalue: failed
- uuid: e81dcef10a30448db51b9805ec60b863
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
mappings:
- value: '1'
newvalue: Other
- value: '2'
newvalue: RAID-0
- value: '3'
newvalue: RAID-1
- value: '4'
newvalue: RAID-5
- value: '5'
newvalue: RAID-6
- value: '6'
newvalue: RAID-10
- value: '7'
newvalue: RAID-50
- value: '8'
newvalue: RAID-60
- value: '9'
newvalue: 'Concatenated RAID 1'
- value: '10'
newvalue: 'Concatenated RAID 5'
- uuid: e9e9b851915747c4b608934cd1235bc5
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
mappings:
- value: '1'
newvalue: 'Not applicable'
- value: '2'
newvalue: Reconstructing
- value: '3'
newvalue: Resynching
- value: '4'
newvalue: Initializing
- value: '5'
newvalue: 'Background init'
- uuid: 92115895f7b9477983c67012b111afb3
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
mappings:
- value: '1'
newvalue: 'No Read Ahead'
- value: '2'
newvalue: 'Read Ahead'
- value: '3'
newvalue: 'Adaptive Read Ahead'
- uuid: 7573aa4192534f44863508890606f917
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Online
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- uuid: c6d4cfe5cf8b43808dce81cc1bcc4be3
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
mappings:
- value: '1'
newvalue: 'Write Through'
- value: '2'
newvalue: 'Write Back'
- value: '3'
newvalue: 'Force Write Back'
- uuid: c5660f822c4a4567888e7f98d3bfab13
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 75be35da1fa9433081562ce9c02af907
expression: '(last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R820 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R820 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)'
name: 'Dell R820: Host has been restarted'
event_name: 'Dell R820: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
graphs:
- uuid: 28d29c2050784efa961c8c8a38195917
name: 'Dell R820: Uptime'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
- sortorder: '1'
color: F63100
item:
host: 'DELL PowerEdge R820 by SNMP'
key: 'dell.server.net.uptime[snmpEngineTime]'