Files
templates-default/Brocade_FC_by_SNMP.yaml
T

1831 lines
75 KiB
YAML

zabbix_export:
version: '7.0'
template_groups:
- uuid: 36bff6c29af64692839d077febfc7079
name: 'Templates/Network devices'
templates:
- uuid: de96d02bd5f242bfa31308ae2131d03f
template: 'Brocade FC by SNMP'
name: 'Brocade FC by SNMP'
description: |
Template Net Brocade FC
MIBs used:
HOST-RESOURCES-MIB
SNMPv2-MIB
SW-MIB
IF-MIB
Known Issues:
Description: no IF-MIB::ifAlias is available
Version: v6.3.1c, v7.0.0c, v7.4.1c
Device: all
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-2
groups:
- name: 'Templates/Network devices'
items:
- uuid: 79adbe7d5d8f4dd6a172bfc3e2d8b23d
name: 'ICMP ping'
type: SIMPLE
key: icmpping
description: |
The host accessibility by ICMP ping.
0 - ICMP ping fails;
1 - ICMP ping successful.
valuemap:
name: 'Service state'
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: 0c73f37e7ffc4acf83a7edeb84398aba
expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0'
name: 'Brocade FC: Unavailable by ICMP ping'
priority: HIGH
description: 'Last three attempts returned timeout. Please check device connectivity.'
tags:
- tag: scope
value: availability
- uuid: 4ae37446cb1e4a2d95f55a41dd295bdf
name: 'ICMP loss'
type: SIMPLE
key: icmppingloss
value_type: FLOAT
units: '%'
description: 'The percentage of lost packets.'
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: eea2256c85764c12b1da83dd8d1a9fe3
expression: 'min(/Brocade FC by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC by SNMP/icmppingloss,5m)<100'
name: 'Brocade FC: High ICMP ping loss'
opdata: 'Loss: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'ICMP packets loss detected.'
dependencies:
- name: 'Brocade FC: Unavailable by ICMP ping'
expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 4c8f61f10759487087d5942756f478b2
name: 'ICMP response time'
type: SIMPLE
key: icmppingsec
value_type: FLOAT
units: s
description: 'The ICMP ping response time (in seconds).'
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: 17df26093a5f42fdb19715371c85f733
expression: 'avg(/Brocade FC by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
name: 'Brocade FC: High ICMP ping response time'
opdata: 'Value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Average ICMP response time is too high.'
dependencies:
- name: 'Brocade FC: High ICMP ping loss'
expression: 'min(/Brocade FC by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC by SNMP/icmppingloss,5m)<100'
- name: 'Brocade FC: Unavailable by ICMP ping'
expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: c7e6790a311c4b4582093cd28341306a
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: network
- uuid: 62ae879ca6ab46aebc8655534acbba06
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: 'system.contact[sysContact.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
- uuid: b17a06635cb2400f9c6d0f848fd38868
name: 'CPU utilization'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.26.1.0]'
key: 'system.cpu.util[swCpuUsage.0]'
value_type: FLOAT
units: '%'
description: |
MIB: SW-MIB
System's CPU usage.
tags:
- tag: component
value: cpu
triggers:
- uuid: 68a50684095941cb90f22fbc8d632e7a
expression: 'min(/Brocade FC by SNMP/system.cpu.util[swCpuUsage.0],5m)>{$CPU.UTIL.CRIT}'
name: 'Brocade FC: High CPU utilization'
event_name: 'Brocade FC: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)'
opdata: 'Current utilization: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'The CPU utilization is too high. The system might be slow to respond.'
tags:
- tag: scope
value: performance
- uuid: 8340ccd92ba940b497375aba810394a4
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: 'system.descr[sysDescr.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should
include the full name and version identification of the system's hardware type, software operating-system, and
networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
- uuid: c6e2d4c076b14ed19fbcb08caa32e5be
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.6.0]'
key: system.hw.firmware
delay: 1h
value_type: CHAR
trends: '0'
description: 'MIB: SW-MIB'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 9c5ae10dbafb45658f25f0279a8a1934
expression: 'last(/Brocade FC by SNMP/system.hw.firmware,#1)<>last(/Brocade FC by SNMP/system.hw.firmware,#2) and length(last(/Brocade FC by SNMP/system.hw.firmware))>0'
name: 'Brocade FC: Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 3c68a1be050d4c1287e63eb7b3b81f8f
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.10.0]'
key: system.hw.serialnumber
delay: 1h
value_type: CHAR
trends: '0'
description: 'MIB: SW-MIB'
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 9939f98da99c435a9b5505e55e8abb5f
expression: 'last(/Brocade FC by SNMP/system.hw.serialnumber,#1)<>last(/Brocade FC by SNMP/system.hw.serialnumber,#2) and length(last(/Brocade FC by SNMP/system.hw.serialnumber))>0'
name: 'Brocade FC: Device has been replaced'
event_name: 'Brocade FC: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: a988240abba8442da83fdbcb789d0138
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]'
key: 'system.hw.uptime[hrSystemUptime.0]'
delay: 30s
trends: '0'
units: uptime
description: |
MIB: HOST-RESOURCES-MIB
The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
preprocessing:
- type: CHECK_NOT_SUPPORTED
parameters:
- '-1'
error_handler: CUSTOM_VALUE
error_handler_params: '0'
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: 88c5304ddeca47779b76d9806b1edc68
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: 'system.location[sysLocation.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
Physical location of the node (e.g., `equipment room`, `3rd floor`). If not provided, the value is a zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
- uuid: d8d912cb5c924f6587c83f08aa0c8ae1
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: system.name
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
triggers:
- uuid: 0e624c73fdca490e809ffe9235cda610
expression: 'last(/Brocade FC by SNMP/system.name,#1)<>last(/Brocade FC by SNMP/system.name,#2) and length(last(/Brocade FC by SNMP/system.name))>0'
name: 'Brocade FC: System name has changed'
event_name: 'Brocade FC: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- tag: scope
value: security
- uuid: 237a5614cb634773853f6d5f42096773
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.3.0]'
key: 'system.net.uptime[sysUpTime.0]'
delay: 30s
trends: '0'
units: uptime
description: |
MIB: SNMPv2-MIB
Time (in hundredths of a second) since the network management portion of the system was last re-initialized.
preprocessing:
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: 939c63320b8e4199b87cc4759011da3c
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: 'system.objectid[sysObjectID.0]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 12h
tags:
- tag: component
value: system
- uuid: 29f1dda8042d4fd18d7da9eb95fea76c
name: 'Overall system health status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.7.0]'
key: 'system.status[swOperStatus.0]'
delay: 30s
trends: '0'
description: |
MIB: SW-MIB
The current operational status of the switch.The states are as follow:
online(1) means the switch is accessible by an external Fibre Channel port
offline(2) means the switch is not accessible
testing(3) means the switch is in a built-in test mode and is not accessible by an external Fibre Channel port
faulty(4) means the switch is not operational.
valuemap:
name: 'SW-MIB::swOperStatus'
tags:
- tag: component
value: system
triggers:
- uuid: b91af8b94e2047538376be9911beadee
expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1'
name: 'Brocade FC: System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for errors'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: b17d4a2bae804c968984b763fa4562fc
expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"offline\"}")=1 or count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"testing\"}")=1'
name: 'Brocade FC: System status is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for warnings'
dependencies:
- name: 'Brocade FC: System status is in critical state'
expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 9a8441cae4fb4c698502a20d5ce23ddf
name: 'Memory utilization'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.26.6.0]'
key: 'vm.memory.util[swMemUsage.0]'
value_type: FLOAT
units: '%'
description: |
MIB: SW-MIB
Memory utilization in %.
tags:
- tag: component
value: memory
triggers:
- uuid: 1991ae08b008488380db02160b15160e
expression: 'min(/Brocade FC by SNMP/vm.memory.util[swMemUsage.0],5m)>{$MEMORY.UTIL.MAX}'
name: 'Brocade FC: High memory utilization'
event_name: 'Brocade FC: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)'
priority: AVERAGE
description: 'The system is running out of free memory.'
tags:
- tag: scope
value: capacity
- tag: scope
value: performance
- uuid: 00b66dbea9464b55bbab004e0eb57c7b
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
description: |
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
Possible values:
0 - not available
1 - available
2 - unknown
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: health
- tag: component
value: network
triggers:
- uuid: 1c67a764531b48f1a931a9a928a8708d
expression: 'max(/Brocade FC by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
name: 'Brocade FC: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
dependencies:
- name: 'Brocade FC: Unavailable by ICMP ping'
expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: 721801e236e34b02b5430d115b23817e
name: 'FAN Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1,{#SENSOR_TYPE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2,{#SENSOR_INFO},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5]'
key: fan.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_TYPE}'
value: '2'
formulaid: A
item_prototypes:
- uuid: 4f37f76d0b3241598e69b091f1835ef5
name: '{#SENSOR_INFO}: Fan speed'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.{#SNMPINDEX}]'
key: 'sensor.fan.speed[swSensorValue.{#SNMPINDEX}]'
units: rpm
description: |
MIB: SW-MIB
The current value (reading) of the sensor.
The value, -2147483648, represents an unknown quantity.
The fan value will be in RPM(revolution per minute)
tags:
- tag: component
value: fan
- uuid: ee2569161ad146b392bb8f331a7f7d19
name: '{#SENSOR_INFO}: Fan status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.{#SNMPINDEX}]'
key: 'sensor.fan.status[swSensorStatus.{#SNMPINDEX}]'
delay: 3m
trends: '0'
description: 'MIB: SW-MIB'
valuemap:
name: 'SW-MIB::swSensorStatus'
tags:
- tag: component
value: fan
trigger_prototypes:
- uuid: 75003433a8304644a20d11b82dcbae14
expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
name: 'Brocade FC: {#SENSOR_INFO}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: 83e8182fd7034edca8317fa91776b6d2
expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1'
name: 'Brocade FC: {#SENSOR_INFO}: Fan is not in normal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the fan unit'
dependencies:
- name: 'Brocade FC: {#SENSOR_INFO}: Fan is in critical state'
expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1'
tags:
- tag: scope
value: notice
- uuid: 58ece372fefb4881ace97a40c5fb09c2
name: 'Network interfaces discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]'
key: net.if.discovery
delay: 1h
filter:
evaltype: AND
conditions:
- macro: '{#IFADMINSTATUS}'
value: '{$NET.IF.IFADMINSTATUS.MATCHES}'
formulaid: A
- macro: '{#IFADMINSTATUS}'
value: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#IFALIAS}'
value: '{$NET.IF.IFALIAS.MATCHES}'
formulaid: C
- macro: '{#IFALIAS}'
value: '{$NET.IF.IFALIAS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
- macro: '{#IFDESCR}'
value: '{$NET.IF.IFDESCR.MATCHES}'
formulaid: E
- macro: '{#IFDESCR}'
value: '{$NET.IF.IFDESCR.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: F
- macro: '{#IFNAME}'
value: '{$NET.IF.IFNAME.MATCHES}'
formulaid: G
- macro: '{#IFNAME}'
value: '{$NET.IF.IFNAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: H
- macro: '{#IFOPERSTATUS}'
value: '{$NET.IF.IFOPERSTATUS.MATCHES}'
formulaid: I
- macro: '{#IFOPERSTATUS}'
value: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: J
- macro: '{#IFTYPE}'
value: '{$NET.IF.IFTYPE.MATCHES}'
formulaid: K
- macro: '{#IFTYPE}'
value: '{$NET.IF.IFTYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: L
description: 'Discovering interfaces from IF-MIB.'
item_prototypes:
- uuid: a780105f84584ba48acef58f573b5728
name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}]'
key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
The number of inbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 04b7026dd1704074b9a18e154d10ef7f
name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}]'
key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: efe5a3957efd4d989809db22ad9cff9d
name: 'Interface {#IFNAME}({#IFALIAS}): Bits received'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}]'
key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]'
delay: 3m
units: bps
description: |
MIB: IF-MIB
The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
- type: MULTIPLIER
parameters:
- '8'
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: a087793253314286a0bfab36a27898bd
name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}]'
key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
The number of outbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.
One possible reason for discarding such a packet could be to free up buffer space.
Discontinuities in the value of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 67d8b40449a24ad28e31ef0363d8b76d
name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}]'
key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
delay: 3m
description: |
MIB: IF-MIB
For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 3c557f4086bc455eb6185878e50b72d9
name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}]'
key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]'
delay: 3m
units: bps
description: |
MIB: IF-MIB
The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
preprocessing:
- type: CHANGE_PER_SECOND
parameters:
- ''
- type: MULTIPLIER
parameters:
- '8'
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: de0920aa56b740ab89118016cdacbc5e
name: 'Interface {#IFNAME}({#IFALIAS}): Speed'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}]'
key: 'net.if.speed[ifHighSpeed.{#SNMPINDEX}]'
delay: 5m
trends: '0'
units: bps
description: |
MIB: IF-MIB
An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.
preprocessing:
- type: MULTIPLIER
parameters:
- '1000000'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
- uuid: 1e9a9d3ea4d24922b8c4b7acc20a3c4f
name: 'Interface {#IFNAME}({#IFALIAS}): Operational status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}]'
key: 'net.if.status[ifOperStatus.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: IF-MIB
The current operational state of the interface.
- The testing(3) state indicates that no operational packet scan be passed
- If ifAdminStatus is down(2) then ifOperStatus should be down(2)
- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic
- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)
- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state
- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.
valuemap:
name: 'IF-MIB::ifOperStatus'
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: e5391912a6b84c1bb41832e88df4fb96
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Link down'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is down.
2. `{$IFCONTROL:"{#IFNAME}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is down.
3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for "eternal off" interfaces.)
WARNING: if closed manually - it will not fire again on the next poll, because of .diff.
manual_close: 'YES'
tags:
- tag: scope
value: availability
- uuid: 391fe664d0e44ed99b2b966c647e1e55
name: 'Interface {#IFNAME}({#IFALIAS}): Interface type'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}]'
key: 'net.if.type[ifType.{#SNMPINDEX}]'
delay: 1h
trends: '0'
description: |
MIB: IF-MIB
The type of interface.
Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA),
through updating the syntax of the IANAifType textual convention.
valuemap:
name: 'IF-MIB::ifType'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: network
- tag: description
value: '{#IFALIAS}'
- tag: interface
value: '{#IFNAME}'
trigger_prototypes:
- uuid: 5a98171af6b342ab97e0c6c9de0bd589
expression: |
change(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
and (
last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or
last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or
last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or
last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or
last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or
last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117
)
and
(last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
(change(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or
(last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2)
name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before'
opdata: 'Current reported speed: {ITEM.LASTVALUE1}'
priority: INFO
description: 'This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually.'
manual_close: 'YES'
dependencies:
- name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
- tag: scope
value: performance
- uuid: a16b52f43a224a11861813be5a11697c
expression: |
(avg(/Brocade FC by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or
avg(/Brocade FC by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and
last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
avg(/Brocade FC by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and
avg(/Brocade FC by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])
name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage'
event_name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)'
opdata: 'In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'The utilization of the network interface is close to its estimated maximum bandwidth.'
manual_close: 'YES'
dependencies:
- name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
- tag: scope
value: performance
- uuid: 9f42c5a5ed1341c1a26263642e4dabe4
expression: |
min(/Brocade FC by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
or min(/Brocade FC by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: |
max(/Brocade FC by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
and max(/Brocade FC by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8
name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): High error rate'
event_name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)'
opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}'
priority: WARNING
description: 'It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.'
manual_close: 'YES'
dependencies:
- name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Link down'
expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))'
recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
graph_prototypes:
- uuid: 0ca148aeaadd45b6bd32e9ecde4127df
name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic'
graph_items:
- drawtype: GRADIENT_LINE
color: 199C0D
item:
host: 'Brocade FC by SNMP'
key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]'
- sortorder: '1'
drawtype: BOLD_LINE
color: F63100
item:
host: 'Brocade FC by SNMP'
key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]'
- sortorder: '2'
color: 00611C
yaxisside: RIGHT
item:
host: 'Brocade FC by SNMP'
key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]'
- sortorder: '3'
color: F7941D
yaxisside: RIGHT
item:
host: 'Brocade FC by SNMP'
key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]'
- sortorder: '4'
color: FC6EA3
yaxisside: RIGHT
item:
host: 'Brocade FC by SNMP'
key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]'
- sortorder: '5'
color: 6C59DC
yaxisside: RIGHT
item:
host: 'Brocade FC by SNMP'
key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]'
- uuid: 32c9720e348e4d4ebb9e70c2b247de29
name: 'PSU Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1,{#SENSOR_TYPE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2,{#SENSOR_INFO},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5]'
key: psu.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_TYPE}'
value: '3'
formulaid: A
item_prototypes:
- uuid: 7a8f32cbb43f4ce789097e8cb26b0456
name: '{#SENSOR_INFO}: Power supply status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.{#SNMPINDEX}]'
key: 'sensor.psu.status[swSensorStatus.{#SNMPINDEX}]'
delay: 3m
trends: '0'
description: 'MIB: SW-MIB'
valuemap:
name: 'SW-MIB::swSensorStatus'
tags:
- tag: component
value: power
trigger_prototypes:
- uuid: 649e7344411242738d9824f861b3c49a
expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
name: 'Brocade FC: {#SENSOR_INFO}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: bfe2f4085f6840da9e8d30f37bb29fdb
expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1'
name: 'Brocade FC: {#SENSOR_INFO}: Power supply is not in normal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the power supply unit for errors'
dependencies:
- name: 'Brocade FC: {#SENSOR_INFO}: Power supply is in critical state'
expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1'
tags:
- tag: scope
value: notice
- uuid: efaa3e2dfb5b405d99998bd6f8a08697
name: 'Temperature Discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1,{#SENSOR_TYPE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2,{#SENSOR_INFO},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5]'
key: temperature.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_TYPE}'
value: '1'
formulaid: A
item_prototypes:
- uuid: f95f92a4151d4039ab3ce73ca231f079
name: '{#SENSOR_INFO}: Temperature status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.{#SNMPINDEX}]'
key: 'sensor.temp.status[swSensorStatus.{#SNMPINDEX}]'
delay: 3m
trends: '0'
description: |
MIB: SW-MIB
Temperature status of testpoint: {#SENSOR_INFO}
valuemap:
name: 'SW-MIB::swSensorStatus'
tags:
- tag: component
value: temperature
- uuid: ee48ef951f124c569327670a2a0f2152
name: '{#SENSOR_INFO}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.{#SNMPINDEX}]'
key: 'sensor.temp.value[swSensorValue.{#SNMPINDEX}]'
delay: 3m
value_type: FLOAT
units: °C
description: |
MIB: SW-MIB
Temperature readings of testpoint: {#SENSOR_INFO}
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 5ee4c1931e244d638b58f945f8a7565c
expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3'
name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above critical threshold'
event_name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SENSOR_INFO}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
- uuid: fc68b3a0ea6643f988c26e3e735d7491
expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'min(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}+3'
name: 'Brocade FC: {#SENSOR_INFO}: Temperature is too low'
event_name: 'Brocade FC: {#SENSOR_INFO}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags:
- tag: scope
value: availability
- tag: scope
value: performance
trigger_prototypes:
- uuid: 726afdedb08848bd86ab4161cef29f42
expression: |
avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_INFO}"}
or
last(/Brocade FC by SNMP/sensor.temp.status[swSensorStatus.{#SNMPINDEX}])={$TEMP_WARN_STATUS}
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_INFO}"}-3'
name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above warning threshold'
event_name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SENSOR_INFO}"}'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
dependencies:
- name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above critical threshold'
expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}'
recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3'
tags:
- tag: scope
value: availability
- tag: scope
value: performance
tags:
- tag: class
value: network
- tag: target
value: brocade
- tag: target
value: brocade-fc
macros:
- macro: '{$CPU.UTIL.CRIT}'
value: '90'
- macro: '{$FAN_CRIT_STATUS}'
value: '2'
- macro: '{$FAN_OK_STATUS}'
value: '4'
- macro: '{$HEALTH_CRIT_STATUS}'
value: '4'
- macro: '{$HEALTH_WARN_STATUS:"offline"}'
value: '2'
- macro: '{$HEALTH_WARN_STATUS:"testing"}'
value: '3'
- macro: '{$ICMP_LOSS_WARN}'
value: '20'
description: 'Warning threshold of ICMP packet loss in %.'
- macro: '{$ICMP_RESPONSE_TIME_WARN}'
value: '0.15'
description: 'Warning threshold of the average ICMP response time in seconds.'
- macro: '{$IF.ERRORS.WARN}'
value: '2'
description: 'Warning threshold of error packet rate. Can be used with interface name as context.'
- macro: '{$IF.UTIL.MAX}'
value: '90'
- macro: '{$IFCONTROL}'
value: '1'
- macro: '{$MEMORY.UTIL.MAX}'
value: '90'
- macro: '{$NET.IF.IFADMINSTATUS.MATCHES}'
value: '^.*'
- macro: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}'
value: ^2$
description: 'Ignore down(2) administrative status'
- macro: '{$NET.IF.IFALIAS.MATCHES}'
value: '.*'
- macro: '{$NET.IF.IFALIAS.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
- macro: '{$NET.IF.IFDESCR.MATCHES}'
value: '.*'
- macro: '{$NET.IF.IFDESCR.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
- macro: '{$NET.IF.IFNAME.MATCHES}'
value: '^.*$'
- macro: '{$NET.IF.IFNAME.NOT_MATCHES}'
value: '(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})'
description: 'Filter out loopbacks, nulls, docker veth links and docker0 bridge by default'
- macro: '{$NET.IF.IFOPERSTATUS.MATCHES}'
value: '^.*$'
- macro: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}'
value: ^6$
description: 'Ignore notPresent(6)'
- macro: '{$NET.IF.IFTYPE.MATCHES}'
value: '.*'
- macro: '{$NET.IF.IFTYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
- macro: '{$PSU_CRIT_STATUS}'
value: '2'
- macro: '{$PSU_OK_STATUS}'
value: '4'
- macro: '{$SNMP.TIMEOUT}'
value: 5m
description: 'Time interval for the SNMP availability trigger.'
- macro: '{$TEMP_CRIT}'
value: '75'
- macro: '{$TEMP_CRIT_LOW}'
value: '5'
- macro: '{$TEMP_WARN}'
value: '65'
- macro: '{$TEMP_WARN_STATUS}'
value: '5'
dashboards:
- uuid: 3cf4d180b2a64e938124274ec468491f
name: 'Brocade FC: General'
pages:
- name: 'Brocade FC: General'
widgets:
- type: graph
name: 'Memory utilization'
width: '36'
height: '5'
fields:
- type: GRAPH
name: graphid.0
value:
host: 'Brocade FC by SNMP'
name: 'Brocade FC: Memory utilization'
- type: STRING
name: reference
value: AAAAA
- type: graph
name: 'CPU utilization'
x: '36'
width: '36'
height: '5'
fields:
- type: GRAPH
name: graphid.0
value:
host: 'Brocade FC by SNMP'
name: 'Brocade FC: CPU utilization'
- type: STRING
name: reference
value: AAAAB
valuemaps:
- uuid: c8b95f7ce9e44b5ea09273fb6c3c9a28
name: 'IF-MIB::ifOperStatus'
mappings:
- value: '1'
newvalue: up
- value: '2'
newvalue: down
- value: '4'
newvalue: unknown
- value: '5'
newvalue: dormant
- value: '6'
newvalue: notPresent
- value: '7'
newvalue: lowerLayerDown
- uuid: db55d484980244b4bf5c60e0908f4e9b
name: 'IF-MIB::ifType'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: regular1822
- value: '3'
newvalue: hdh1822
- value: '4'
newvalue: ddnX25
- value: '5'
newvalue: rfc877x25
- value: '6'
newvalue: ethernetCsmacd
- value: '7'
newvalue: iso88023Csmacd
- value: '8'
newvalue: iso88024TokenBus
- value: '9'
newvalue: iso88025TokenRing
- value: '10'
newvalue: iso88026Man
- value: '11'
newvalue: starLan
- value: '12'
newvalue: proteon10Mbit
- value: '13'
newvalue: proteon80Mbit
- value: '14'
newvalue: hyperchannel
- value: '15'
newvalue: fddi
- value: '16'
newvalue: lapb
- value: '17'
newvalue: sdlc
- value: '18'
newvalue: ds1
- value: '19'
newvalue: e1
- value: '20'
newvalue: basicISDN
- value: '21'
newvalue: primaryISDN
- value: '22'
newvalue: propPointToPointSerial
- value: '23'
newvalue: ppp
- value: '24'
newvalue: softwareLoopback
- value: '25'
newvalue: eon
- value: '26'
newvalue: ethernet3Mbit
- value: '27'
newvalue: nsip
- value: '28'
newvalue: slip
- value: '29'
newvalue: ultra
- value: '30'
newvalue: ds3
- value: '31'
newvalue: sip
- value: '32'
newvalue: frameRelay
- value: '33'
newvalue: rs232
- value: '34'
newvalue: para
- value: '35'
newvalue: arcnet
- value: '36'
newvalue: arcnetPlus
- value: '37'
newvalue: atm
- value: '38'
newvalue: miox25
- value: '39'
newvalue: sonet
- value: '40'
newvalue: x25ple
- value: '41'
newvalue: iso88022llc
- value: '42'
newvalue: localTalk
- value: '43'
newvalue: smdsDxi
- value: '44'
newvalue: frameRelayService
- value: '45'
newvalue: v35
- value: '46'
newvalue: hssi
- value: '47'
newvalue: hippi
- value: '48'
newvalue: modem
- value: '49'
newvalue: aal5
- value: '50'
newvalue: sonetPath
- value: '51'
newvalue: sonetVT
- value: '52'
newvalue: smdsIcip
- value: '53'
newvalue: propVirtual
- value: '54'
newvalue: propMultiplexor
- value: '55'
newvalue: ieee80212
- value: '56'
newvalue: fibreChannel
- value: '57'
newvalue: hippiInterface
- value: '58'
newvalue: frameRelayInterconnect
- value: '59'
newvalue: aflane8023
- value: '60'
newvalue: aflane8025
- value: '61'
newvalue: cctEmul
- value: '62'
newvalue: fastEther
- value: '63'
newvalue: isdn
- value: '64'
newvalue: v11
- value: '65'
newvalue: v36
- value: '66'
newvalue: g703at64k
- value: '67'
newvalue: g703at2mb
- value: '68'
newvalue: qllc
- value: '69'
newvalue: fastEtherFX
- value: '70'
newvalue: channel
- value: '71'
newvalue: ieee80211
- value: '72'
newvalue: ibm370parChan
- value: '73'
newvalue: escon
- value: '74'
newvalue: dlsw
- value: '75'
newvalue: isdns
- value: '76'
newvalue: isdnu
- value: '77'
newvalue: lapd
- value: '78'
newvalue: ipSwitch
- value: '79'
newvalue: rsrb
- value: '80'
newvalue: atmLogical
- value: '81'
newvalue: ds0
- value: '82'
newvalue: ds0Bundle
- value: '83'
newvalue: bsc
- value: '84'
newvalue: async
- value: '85'
newvalue: cnr
- value: '86'
newvalue: iso88025Dtr
- value: '87'
newvalue: eplrs
- value: '88'
newvalue: arap
- value: '89'
newvalue: propCnls
- value: '90'
newvalue: hostPad
- value: '91'
newvalue: termPad
- value: '92'
newvalue: frameRelayMPI
- value: '93'
newvalue: x213
- value: '94'
newvalue: adsl
- value: '95'
newvalue: radsl
- value: '96'
newvalue: sdsl
- value: '97'
newvalue: vdsl
- value: '98'
newvalue: iso88025CRFPInt
- value: '99'
newvalue: myrinet
- value: '100'
newvalue: voiceEM
- value: '101'
newvalue: voiceFXO
- value: '102'
newvalue: voiceFXS
- value: '103'
newvalue: voiceEncap
- value: '104'
newvalue: voiceOverIp
- value: '105'
newvalue: atmDxi
- value: '106'
newvalue: atmFuni
- value: '107'
newvalue: atmIma
- value: '108'
newvalue: pppMultilinkBundle
- value: '109'
newvalue: ipOverCdlc
- value: '110'
newvalue: ipOverClaw
- value: '111'
newvalue: stackToStack
- value: '112'
newvalue: virtualIpAddress
- value: '113'
newvalue: mpc
- value: '114'
newvalue: ipOverAtm
- value: '115'
newvalue: iso88025Fiber
- value: '116'
newvalue: tdlc
- value: '117'
newvalue: gigabitEthernet
- value: '118'
newvalue: hdlc
- value: '119'
newvalue: lapf
- value: '120'
newvalue: v37
- value: '121'
newvalue: x25mlp
- value: '122'
newvalue: x25huntGroup
- value: '123'
newvalue: trasnpHdlc
- value: '124'
newvalue: interleave
- value: '125'
newvalue: fast
- value: '126'
newvalue: ip
- value: '127'
newvalue: docsCableMaclayer
- value: '128'
newvalue: docsCableDownstream
- value: '129'
newvalue: docsCableUpstream
- value: '130'
newvalue: a12MppSwitch
- value: '131'
newvalue: tunnel
- value: '132'
newvalue: coffee
- value: '133'
newvalue: ces
- value: '134'
newvalue: atmSubInterface
- value: '135'
newvalue: l2vlan
- value: '136'
newvalue: l3ipvlan
- value: '137'
newvalue: l3ipxvlan
- value: '138'
newvalue: digitalPowerline
- value: '139'
newvalue: mediaMailOverIp
- value: '140'
newvalue: dtm
- value: '141'
newvalue: dcn
- value: '142'
newvalue: ipForward
- value: '143'
newvalue: msdsl
- value: '144'
newvalue: ieee1394
- value: '145'
newvalue: if-gsn
- value: '146'
newvalue: dvbRccMacLayer
- value: '147'
newvalue: dvbRccDownstream
- value: '148'
newvalue: dvbRccUpstream
- value: '149'
newvalue: atmVirtual
- value: '150'
newvalue: mplsTunnel
- value: '151'
newvalue: srp
- value: '152'
newvalue: voiceOverAtm
- value: '153'
newvalue: voiceOverFrameRelay
- value: '154'
newvalue: idsl
- value: '155'
newvalue: compositeLink
- value: '156'
newvalue: ss7SigLink
- value: '157'
newvalue: propWirelessP2P
- value: '158'
newvalue: frForward
- value: '159'
newvalue: rfc1483
- value: '160'
newvalue: usb
- value: '161'
newvalue: ieee8023adLag
- value: '162'
newvalue: bgppolicyaccounting
- value: '163'
newvalue: frf16MfrBundle
- value: '164'
newvalue: h323Gatekeeper
- value: '165'
newvalue: h323Proxy
- value: '166'
newvalue: mpls
- value: '167'
newvalue: mfSigLink
- value: '168'
newvalue: hdsl2
- value: '169'
newvalue: shdsl
- value: '170'
newvalue: ds1FDL
- value: '171'
newvalue: pos
- value: '172'
newvalue: dvbAsiIn
- value: '173'
newvalue: dvbAsiOut
- value: '174'
newvalue: plc
- value: '175'
newvalue: nfas
- value: '176'
newvalue: tr008
- value: '177'
newvalue: gr303RDT
- value: '178'
newvalue: gr303IDT
- value: '179'
newvalue: isup
- value: '180'
newvalue: propDocsWirelessMaclayer
- value: '181'
newvalue: propDocsWirelessDownstream
- value: '182'
newvalue: propDocsWirelessUpstream
- value: '183'
newvalue: hiperlan2
- value: '184'
newvalue: propBWAp2Mp
- value: '185'
newvalue: sonetOverheadChannel
- value: '186'
newvalue: digitalWrapperOverheadChannel
- value: '187'
newvalue: aal2
- value: '188'
newvalue: radioMAC
- value: '189'
newvalue: atmRadio
- value: '190'
newvalue: imt
- value: '191'
newvalue: mvl
- value: '192'
newvalue: reachDSL
- value: '193'
newvalue: frDlciEndPt
- value: '194'
newvalue: atmVciEndPt
- value: '195'
newvalue: opticalChannel
- value: '196'
newvalue: opticalTransport
- value: '197'
newvalue: propAtm
- value: '198'
newvalue: voiceOverCable
- value: '199'
newvalue: infiniband
- value: '200'
newvalue: teLink
- value: '201'
newvalue: q2931
- value: '202'
newvalue: virtualTg
- value: '203'
newvalue: sipTg
- value: '204'
newvalue: sipSig
- value: '205'
newvalue: docsCableUpstreamChannel
- value: '206'
newvalue: econet
- value: '207'
newvalue: pon155
- value: '208'
newvalue: pon622
- value: '209'
newvalue: bridge
- value: '210'
newvalue: linegroup
- value: '211'
newvalue: voiceEMFGD
- value: '212'
newvalue: voiceFGDEANA
- value: '213'
newvalue: voiceDID
- value: '214'
newvalue: mpegTransport
- value: '215'
newvalue: sixToFour
- value: '216'
newvalue: gtp
- value: '217'
newvalue: pdnEtherLoop1
- value: '218'
newvalue: pdnEtherLoop2
- value: '219'
newvalue: opticalChannelGroup
- value: '220'
newvalue: homepna
- value: '221'
newvalue: gfp
- value: '222'
newvalue: ciscoISLvlan
- value: '223'
newvalue: actelisMetaLOOP
- value: '224'
newvalue: fcipLink
- value: '225'
newvalue: rpr
- value: '226'
newvalue: qam
- value: '227'
newvalue: lmp
- value: '228'
newvalue: cblVectaStar
- value: '229'
newvalue: docsCableMCmtsDownstream
- value: '230'
newvalue: adsl2
- value: '231'
newvalue: macSecControlledIF
- value: '232'
newvalue: macSecUncontrolledIF
- value: '233'
newvalue: aviciOpticalEther
- value: '234'
newvalue: atmbond
- value: '235'
newvalue: voiceFGDOS
- value: '236'
newvalue: mocaVersion1
- value: '237'
newvalue: ieee80216WMAN
- value: '238'
newvalue: adsl2plus
- value: '239'
newvalue: dvbRcsMacLayer
- value: '240'
newvalue: dvbTdm
- value: '241'
newvalue: dvbRcsTdma
- value: '242'
newvalue: x86Laps
- value: '243'
newvalue: wwanPP
- value: '244'
newvalue: wwanPP2
- value: '245'
newvalue: voiceEBS
- value: '246'
newvalue: ifPwType
- value: '247'
newvalue: ilan
- value: '248'
newvalue: pip
- value: '249'
newvalue: aluELP
- value: '250'
newvalue: gpon
- value: '251'
newvalue: vdsl2
- value: '252'
newvalue: capwapDot11Profile
- value: '253'
newvalue: capwapDot11Bss
- value: '254'
newvalue: capwapWtpVirtualRadio
- value: '255'
newvalue: bits
- value: '256'
newvalue: docsCableUpstreamRfPort
- value: '257'
newvalue: cableDownstreamRfPort
- value: '258'
newvalue: vmwareVirtualNic
- value: '259'
newvalue: ieee802154
- value: '260'
newvalue: otnOdu
- value: '261'
newvalue: otnOtu
- value: '262'
newvalue: ifVfiType
- value: '263'
newvalue: g9981
- value: '264'
newvalue: g9982
- value: '265'
newvalue: g9983
- value: '266'
newvalue: aluEpon
- value: '267'
newvalue: aluEponOnu
- value: '268'
newvalue: aluEponPhysicalUni
- value: '269'
newvalue: aluEponLogicalLink
- value: '270'
newvalue: aluGponOnu
- value: '271'
newvalue: aluGponPhysicalUni
- value: '272'
newvalue: vmwareNicTeam
- value: '277'
newvalue: docsOfdmDownstream
- value: '278'
newvalue: docsOfdmaUpstream
- value: '279'
newvalue: gfast
- value: '280'
newvalue: sdci
- value: '281'
newvalue: xboxWireless
- value: '282'
newvalue: fastdsl
- value: '283'
newvalue: docsCableScte55d1FwdOob
- value: '284'
newvalue: docsCableScte55d1RetOob
- value: '285'
newvalue: docsCableScte55d2DsOob
- value: '286'
newvalue: docsCableScte55d2UsOob
- value: '287'
newvalue: docsCableNdf
- value: '288'
newvalue: docsCableNdr
- value: '289'
newvalue: ptm
- value: '290'
newvalue: ghn
- uuid: 17cb6bdbe4244a8fab16c0cbca5a4a00
name: 'Service state'
mappings:
- value: '0'
newvalue: Down
- value: '1'
newvalue: Up
- uuid: 54427fdf694547c598e3662df09a980a
name: 'SW-MIB::swOperStatus'
mappings:
- value: '1'
newvalue: online
- value: '2'
newvalue: offline
- value: '3'
newvalue: testing
- value: '4'
newvalue: faulty
- uuid: 73618556ee4b4e8f9ec9acf0893e13ea
name: 'SW-MIB::swSensorStatus'
mappings:
- value: '1'
newvalue: unknown
- value: '2'
newvalue: faulty
- value: '3'
newvalue: below-min
- value: '4'
newvalue: nominal
- value: '5'
newvalue: above-max
- value: '6'
newvalue: absent
- uuid: 2fdee7620a3a449f9dd61eb3405e620c
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 42bb10d788484b92ac7290e171ee28a2
expression: '(last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Brocade FC by SNMP/system.net.uptime[sysUpTime.0])<10m)'
name: 'Brocade FC: Host has been restarted'
event_name: 'Brocade FC: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
dependencies:
- name: 'Brocade FC: No SNMP data collection'
expression: 'max(/Brocade FC by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
tags:
- tag: scope
value: notice
graphs:
- uuid: 8d1edf299fde462bbca5ceaf1b439223
name: 'Brocade FC: CPU utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
- drawtype: GRADIENT_LINE
color: 199C0D
item:
host: 'Brocade FC by SNMP'
key: 'system.cpu.util[swCpuUsage.0]'
- uuid: d1e06bb17c2f458699664bfa61c12496
name: 'Brocade FC: Memory utilization'
ymin_type_1: FIXED
ymax_type_1: FIXED
graph_items:
- drawtype: GRADIENT_LINE
color: 199C0D
item:
host: 'Brocade FC by SNMP'
key: 'vm.memory.util[swMemUsage.0]'