Files
templates-default/HPE_ProLiant_BL460_by_SNMP.yaml

2203 lines
106 KiB
YAML

zabbix_export:
version: '7.0'
template_groups:
- uuid: e960332b3f6c46a1956486d4f3f99fce
name: 'Templates/Server hardware'
templates:
- uuid: 172ec7e51f1c4a6ba49baffbab3dda97
template: 'HPE ProLiant BL460 by SNMP'
name: 'HPE ProLiant BL460 by SNMP'
description: |
Template for HPE ProLiant BL460 servers with HP iLO version 4 and later.
MIBs used:
HOST-RESOURCES-MIB
CPQHLTH-MIB
SNMPv2-MIB
CPQNIC-MIB
CPQSINFO-MIB
CPQIDA-MIB
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-3
groups:
- name: 'Templates/Server hardware'
items:
- uuid: 0747f8f3cc624f469324c127577aa9f9
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: 'hp.server.contact[sysContact]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: cc714f5445be431192dbeb553f0aa5c5
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: 'hp.server.descr[sysDescr]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should
include the full name and version identification of the system's hardware type, software operating-system, and
networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: bf4baaaa76dc4f39bd39c62742f03e26
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.2.2.4.2.0]'
key: 'hp.server.hw.model[cpqSiProductName]'
value_type: CHAR
trends: '0'
description: |
MIB: CPQSINFO-MIB
The machine product name. The name of the machine used in this system.
inventory_link: MODEL
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 6d5e2b9ae30b4c43a91cada24c4cc240
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.2.2.2.1.0]'
key: 'hp.server.hw.serialnumber[cpqSiSysSerialNum]'
value_type: CHAR
trends: '0'
description: |
MIB: CPQSINFO-MIB
The serial number of the physical system unit. The string will be empty if the system does not report the serial number function.
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 1bc442ba67dc42d298d98feb845d8730
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum],#1)<>last(/HPE ProLiant BL460 by SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum],#2) and length(last(/HPE ProLiant BL460 by SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum]))>0'
name: 'HPE ProLiant BL460: Device has been replaced'
event_name: 'HPE ProLiant BL460: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 22f0b65d03d44ae0be7133eb19ecc920
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]'
key: 'hp.server.hw.uptime[hrSystemUptime]'
trends: '0'
units: uptime
description: |
MIB: HOST-RESOURCES-MIB
The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
preprocessing:
- type: CHECK_NOT_SUPPORTED
parameters:
- '-1'
error_handler: CUSTOM_VALUE
error_handler_params: '0'
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: b85a86fa36bd484cbd36cd25d2a605f9
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: 'hp.server.location[sysLocation]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 3df8b71c3f14432e8cd43fbc24f12447
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: 'hp.server.name[sysName]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 87570f607b174ebe887920034a1be1ef
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.name[sysName],#1)<>last(/HPE ProLiant BL460 by SNMP/hp.server.name[sysName],#2) and length(last(/HPE ProLiant BL460 by SNMP/hp.server.name[sysName]))>0'
name: 'HPE ProLiant BL460: System name has changed'
event_name: 'HPE ProLiant BL460: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 65ec5672f1de4852b1ee52ce57e4f58f
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.3.0]'
key: 'hp.server.net.uptime[sysUpTime]'
trends: '0'
units: uptime
description: |
MIB: SNMPv2-MIB
The time (in hundredths of a second) since the network management portion of the system was last re-initialized.
preprocessing:
- type: MULTIPLIER
parameters:
- '0.01'
tags:
- tag: component
value: system
- uuid: 8573488eb0114109bc3c94f2edf00792
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: 'hp.server.objectid[sysObjectID]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 3891df22d63d4be5a62c8a27ac9d8965
name: 'System temperature status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.1.0]'
key: 'hp.server.sensor.temp.status[cpqHeThermalCondition]'
trends: '0'
description: |
MIB: CPQHLTH-MIB
This value specifies the overall condition of the system's thermal environment.
This value will be one of the following:
other(1) Temperature could not be determined.
ok(2) The temperature sensor is within normal operating range.
degraded(3) The temperature sensor is outside of normal operating range.
failed(4) The temperature sensor detects a condition that could permanently damage the system.
valuemap:
name: 'CPQSINFO-MIB::status'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
- uuid: a8ea3fc6a5914a868be12f21342a9678
name: 'Overall system health status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.1.3.0]'
key: 'hp.server.status[cpqHeMibCondition]'
trends: '0'
description: |
MIB: CPQHLTH-MIB
The overall condition. This object represents the overall status of the server information represented by this MIB.
valuemap:
name: 'CPQSINFO-MIB::status'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 4d7ac12aec954df2b369ddd0536d3bd5
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.CRIT}'
name: 'HPE ProLiant BL460: System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for errors.'
tags:
- tag: scope
value: available
- uuid: 9ffbca9c012541b9a36956b4ae06d339
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.WARN}'
name: 'HPE ProLiant BL460: System status is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for warnings.'
dependencies:
- name: 'HPE ProLiant BL460: System status is in critical state'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.CRIT}'
tags:
- tag: scope
value: available
- uuid: 37dc9b6453184fe58435d12d422582d9
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items.'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: network
- uuid: d2e80ecf16bb49af99eb52a45b8c11cf
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 236a5d37e58a415aa81db6e59eb826dc
expression: 'max(/HPE ProLiant BL460 by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
name: 'HPE ProLiant BL460: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: available
discovery_rules:
- uuid: 79cb6edf94f441eea4b429e8474fa0c9
name: 'Array controller cache discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#CACHE_STATUS},1.3.6.1.4.1.232.3.2.2.2.1.2,{#CACHE_CNTRL_INDEX},1.3.6.1.4.1.232.3.2.2.2.1.1]'
key: array.cache.discovery
delay: 1h
description: 'Scanning table of Array controllers: CPQIDA-MIB::cpqDaAccelTable'
item_prototypes:
- uuid: 0cf60fc04cc243df95145b5e3128b598
name: '#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.2.2.1.6.{#SNMPINDEX}]'
key: 'hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQIDA-MIB
Cache Module Board Backup Power Status. This monitors the status of each backup power source on the board.
The backup power source can only recharge when the system has power applied. The type of backup power source used is indicated by cpqDaAccelBackupPowerSource.
The following values are valid:
Other (1) Indicates that the instrument agent does not recognize backup power status. You may need to update your software.
Ok (2) The backup power source is fully charged.
Recharging (3) The array controller has one or more cache module backup power sources that are recharging.
Cache module operations such as Battery/Flash Backed Write Cache, Expansion, Extension and Migration are temporarily suspended until the backup power source is fully charged.
Cache module operations will automatically resume when charging is complete.
Failed (4) The battery pack is below the sufficient voltage level and has not recharged in 36 hours.
Your Cache Module board needs to be serviced.
Degraded (5) The battery is still operating, however, one of the batteries in the pack has failed to recharge properly.
Your Cache Module board should be serviced as soon as possible.
NotPresent (6) A backup power source is not present on the cache module board. Some controllers do not have backup power sources.
Capacitor Failed (7) The flash backed cache module capacitor is below the sufficient voltage level and has not recharged in 10 minutes. Your Cache Module board needs to be serviced.
valuemap:
name: 'CPQIDA-MIB::cpqDaAccelBattery'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: diskarray
- tag: component
value: storage
trigger_prototypes:
- uuid: 42c0ff05c06f47089322dface6c54778
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"} or last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}'
name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: available
- uuid: 28f83720bdd84ab3acb43cc8caac7507
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"degraded"}'
name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical state'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"} or last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}'
tags:
- tag: scope
value: available
- uuid: 10e011c0c8cf4571bfdd2ab414c1853b
name: '#{#CACHE_CNTRL_INDEX}: Disk array cache controller status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.2.2.1.2.{#SNMPINDEX}]'
key: 'hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQIDA-MIB
Cache Module/Operations Status. This describes the status of the cache module and/or cache operations.
Note that for some controller models, a cache module board that physically attaches to the controller or chipset may not be an available option.
The status can be:
Other (1)
Indicates that the instrument agent does not recognize the status of the cache module. You may need to upgrade the instrument agent.
Invalid (2)
Indicates that a cache module board has not been installed in this system or is present but not configured.
Enabled (3)
Indicates that cache operations are currently configured and enabled for at least one logical drive.
Temporarily Disabled (4)
Indicates that cache operations have been temporarily disabled. View the cache module board error code object to determine why the write cache operations have been temporarily disabled.
Permanently Disabled (5)
Indicates that cache operations have been permanently disabled. View the cache module board error code object to determine why the write cache operations have been disabled.
Cache Module Flash Memory Not Attached (6)
Indicates that the flash memory component of the flash backed cache module is not attached. This status will be set when the flash memory is not attached and the Supercap is attached. This value is only used on flash backed cache modules that support removable flash memory.
Cache Module Degraded Failsafe Speed (7)
Indicates that the cache module board is currently degraded and operating at a failsafe speed. View variables cpqDaCacheMemoryDataWidth and cpqDaCacheMemoryTransferRate to obtain the cache module board`s current memory data width and memory transfer rate.
Cache Module Critical Failure (8)
Indicates that the cache module board has encountered a critical failure. The controller is currently operating in Zero Memory Raid mode.
Read Cache Could Not Be Mapped (9)
Indicates that the read cache memory in a split cache configuration could not be mapped by the operating system and as a result is not available. This status may be caused by virtual space limitations in certain operating systems and is only applicable to B-Series controllers.
valuemap:
name: 'CPQIDA-MIB::cpqDaAccelStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: diskarray
- tag: component
value: storage
trigger_prototypes:
- uuid: d9fc0ecef7844e7190d89f4747f82661
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}'
name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: available
- uuid: 9b60ae9eec734644bcff9cbac9407b08
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"} or last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"} or last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}'
name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}'
tags:
- tag: scope
value: available
- uuid: 61e28304c16f4855abfbcef8249a2fa6
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.STATUS.OK:"enabled"} and last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.STATUS.WARN:"invalid"}'
name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller is not in optimal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}'
- name: 'HPE ProLiant BL460: #{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning state'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"} or last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"} or last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}'
tags:
- tag: scope
value: available
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 3e72130010414c7dbc3b7b050df9e577
name: 'Array controller discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.3.2.2.1.1.1,{#CNTLR_SLOT},1.3.6.1.4.1.232.3.2.2.1.1.5,{#CNTLR_LOCATION},1.3.6.1.4.1.232.3.2.2.1.1.20]'
key: array.discovery
delay: 1h
description: 'Scanning table of Array controllers: CPQIDA-MIB::cpqDaCntlrTable'
item_prototypes:
- uuid: be46bc977cdd4a85a364628a21df099d
name: '{#CNTLR_LOCATION}: Disk array controller model'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.2.1.1.2.{#SNMPINDEX}]'
key: 'hp.server.hw.diskarray.model[cpqDaCntlrModel.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQIDA-MIB
Array Controller Model. The type of controller card.
valuemap:
name: 'CPQIDA-MIB::cpqDaCntlrModel'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: diskarray
- tag: component
value: storage
- uuid: d89a3b9bab6c4439a9797ee9208fec26
name: '{#CNTLR_LOCATION}: Disk array controller status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.2.1.1.6.{#SNMPINDEX}]'
key: 'hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQIDA-MIB
This value represents the overall condition of this controller,
and any associated logical drives, physical drives, and array accelerators.
valuemap:
name: 'CPQSINFO-MIB::status'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: diskarray
- tag: component
value: storage
trigger_prototypes:
- uuid: d0e8bcc0510c4e86bfcd3e9d601f83e0
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}'
name: 'HPE ProLiant BL460: {#CNTLR_LOCATION}: Disk array controller is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: available
- uuid: a38ea92527b44599b690c068a62481ed
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN}'
name: 'HPE ProLiant BL460: {#CNTLR_LOCATION}: Disk array controller is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
dependencies:
- name: 'HPE ProLiant BL460: {#CNTLR_LOCATION}: Disk array controller is in critical state'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}'
tags:
- tag: scope
value: available
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: cbcd697782e34a5e87cef72d65229a87
name: 'FAN discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.7.1.9]'
key: fan.discovery
delay: 1h
description: 'CPQHLTH-MIB::cpqHeFltTolFanCondition'
item_prototypes:
- uuid: 02b11840d01245cfbac4e3a5264c713e
name: 'Fan {#SNMPINDEX}: Fan status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.7.1.9.{#SNMPINDEX}]'
key: 'hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQHLTH-MIB
The condition of the fan.
This value will be one of the following:
other(1) Fan status detection is not supported by this system or driver.
ok(2) The fan is operating properly.
degraded(2) A redundant fan is not operating properly.
failed(4) A non-redundant fan is not operating properly.
valuemap:
name: 'CPQSINFO-MIB::status'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: fan
trigger_prototypes:
- uuid: ab33e6666fd14aac8f703c72fd9b760e
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.CRIT}'
name: 'HPE ProLiant BL460: Fan {#SNMPINDEX}: Fan is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit.'
tags:
- tag: scope
value: available
- uuid: a9098b4dcbe04b3a82f0353f115345d7
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.WARN}'
name: 'HPE ProLiant BL460: Fan {#SNMPINDEX}: Fan is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit.'
dependencies:
- name: 'HPE ProLiant BL460: Fan {#SNMPINDEX}: Fan is in critical state'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.CRIT}'
tags:
- tag: scope
value: available
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: dbe83d07252743f2bc889ce320730d78
name: 'Network interface discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#ADAPTER_INDEX},1.3.6.1.4.1.232.18.2.3.1.1.1,{#ADAPTER_NAME},1.3.6.1.4.1.232.18.2.3.1.1.39]'
key: net.if.discovery
delay: 1h
description: 'CPQIDA-MIB::cpqNicIfPhysAdapterTable'
item_prototypes:
- uuid: 1b446f4de8be4eeab2410756739eae6c
name: '{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.18.2.3.1.1.14.{#SNMPINDEX}]'
key: 'hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}]'
description: |
MIB: CPQNIC-MIB
The physical adapter status. The following values are valid:
unknown(1)
The instrument agent was not able to determine the status of the adapter. The instrument agent may need to be upgraded.
ok(2)
The physical adapter is operating properly.
generalFailure(3)
The physical adapter has failed.
linkFailure(4)
The physical adapter has lost link. Check the cable connections to this adapter.
valuemap:
name: 'CPQNIC-MIB::cpqNicIfPhysAdapterStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: 477f8237ed7c4d99af92e94f7563e01c
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=3'
name: 'HPE ProLiant BL460: {#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failed'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the physical adapter.'
tags:
- tag: scope
value: available
- uuid: 5962382262854335bc42ae47203e44a7
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=4'
name: 'HPE ProLiant BL460: {#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has lost link'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the cable connections to this adapter.'
dependencies:
- name: 'HPE ProLiant BL460: {#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failed'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=3'
tags:
- tag: scope
value: available
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 4ec2950e764249dc9c091e92dbba4137
name: 'Physical disk discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.3.2.5.1.1.5,{#DISK_LOCATION},1.3.6.1.4.1.232.3.2.5.1.1.64]'
key: physicaldisk.discovery
delay: 1h
description: 'Scanning table of physical drive entries CPQIDA-MIB::cpqDaPhyDrvTable.'
item_prototypes:
- uuid: 6ebfcb4a2bd44407920c47f060ec6307
name: '{#DISK_LOCATION}: Physical disk media type'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.5.1.1.69.{#SNMPINDEX}]'
key: 'hp.server.hw.physicaldisk.media_type[cpqDaPhyDrvMediaType.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQIDA-MIB
Drive Array Physical Drive Media Type. The following values are defined:
other(1) The instrument agent is unable to determine the physical drive's media type.
rotatingPlatters(2) The physical drive media is composed of rotating platters.
solidState(3) The physical drive media is composed of solid state electronics.
valuemap:
name: 'CPQIDA-MIB::cpqDaPhyDrvMediaType'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 6c59eaa90b964ad4b9f5a0511d620e9d
name: '{#DISK_LOCATION}: Physical disk model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.5.1.1.3.{#SNMPINDEX}]'
key: 'hp.server.hw.physicaldisk.model[cpqDaPhyDrvModel.{#SNMPINDEX}]'
value_type: CHAR
trends: '0'
description: |
MIB: CPQIDA-MIB
Physical Drive Model. This is a text description of the physical drive.
The text that appears depends upon who manufactured the drive and the drive type.
If a drive fails, note the model to identify the type of drive necessary for replacement.
If a model number is not present, you may not have properly initialized the drive array to which the physical drive is attached for monitoring.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: f4f6e63dd1714c2ca721baebb478f5ab
name: '{#DISK_LOCATION}: Physical disk serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.5.1.1.51.{#SNMPINDEX}]'
key: 'hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}]'
value_type: CHAR
trends: '0'
description: |
MIB: CPQIDA-MIB
Physical Drive Serial Number.
This is the serial number assigned to the physical drive.
This value is based upon the serial number as returned by the SCSI inquiry command
but may have been modified due to space limitations. This can be used for identification purposes.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: d3dbef930bca4808ae3bf32ba84a987a
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}],#1)<>last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}],#2) and length(last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}]))>0'
name: 'HPE ProLiant BL460: {#DISK_LOCATION}: Disk has been replaced'
event_name: 'HPE ProLiant BL460: {#DISK_LOCATION}: Disk has been replaced (new serial number received)'
priority: INFO
description: 'Disk serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: dee3a8bb94184bad80d058cb9ac3d324
name: '{#DISK_LOCATION}: Disk size'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.5.1.1.45.{#SNMPINDEX}]'
key: 'hp.server.hw.physicaldisk.size[cpqDaPhyDrvMediaType.{#SNMPINDEX}]'
trends: '0'
units: B
description: |
MIB: CPQIDA-MIB
Physical Drive Size in MB.
This is the size of the physical drive in megabytes.
This value is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may differ
from the advertised size of a drive. This field is only applicable for controllers which support SCSI drives,
and therefore is not supported by the IDA or IDA-2 controllers. The field will contain 0xFFFFFFFF if the drive capacity cannot be calculated
or if the controller does not support SCSI drives.
preprocessing:
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: e08b144330824b9f8a9df61f4e4016b4
name: '{#DISK_LOCATION}: Physical disk S.M.A.R.T. status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.5.1.1.57.{#SNMPINDEX}]'
key: 'hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQIDA-MIB
Physical Drive S.M.A.R.T Status. The following values are defined:
other(1) The agent is unable to determine if the status of S.M.A.R.T predictive failure monitoring for this drive.
ok(2) Indicates the drive is functioning properly.
replaceDrive(3) Indicates that the drive has a S.M.A.R.T predictive failure error and should be replaced.
valuemap:
name: 'CPQIDA-MIB::cpqDaPhyDrvSmartStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 6fb9a3a867f74290974b106755763369
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}'
name: 'HPE ProLiant BL460: {#DISK_LOCATION}: Physical disk S.M.A.R.T. failed'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Disk probably requires replacement.'
dependencies:
- name: 'HPE ProLiant BL460: {#DISK_LOCATION}: Physical disk failed'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL}'
tags:
- tag: scope
value: available
- uuid: d0449cc58efb4258ba71e8d6837cab20
name: '{#DISK_LOCATION}: Physical disk status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.5.1.1.6.{#SNMPINDEX}]'
key: 'hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQIDA-MIB
Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status:
other (1) Indicates that the instrument agent does not recognize the drive.
You may need to upgrade your instrument agent and/or driver software.
ok (2) Indicates the drive is functioning properly.
failed (3) Indicates that the drive is no longer operating and should be replaced.
predictiveFailure(4) Indicates that the drive has a predictive failure error and should be replaced.
valuemap:
name: 'CPQIDA-MIB::cpqDaPhyDrvStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 21224423e69148a797e5ae4fcdda8ed5
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL}'
name: 'HPE ProLiant BL460: {#DISK_LOCATION}: Physical disk failed'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check physical disk for warnings or errors.'
tags:
- tag: scope
value: available
- uuid: ff246b7598f24ab88aa6e7119750e57b
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN}'
name: 'HPE ProLiant BL460: {#DISK_LOCATION}: Physical disk is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check physical disk for warnings or errors.'
dependencies:
- name: 'HPE ProLiant BL460: {#DISK_LOCATION}: Physical disk failed'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL}'
tags:
- tag: scope
value: available
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 5b9a240a6b864513b2b0ac8a4f0a0c07
name: 'PSU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.9.3.1.5,{#CHASSIS_NUM},1.3.6.1.4.1.232.6.2.9.3.1.1,{#BAY_NUM},1.3.6.1.4.1.232.6.2.9.3.1.2]'
key: psu.discovery
delay: 1h
description: 'CPQHLTH-MIB::cpqHeFltTolPowerSupplyStatus'
item_prototypes:
- uuid: c49420a345664c719d9eb02f0ee866c1
name: 'Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.9.3.1.4.{#SNMPINDEX}]'
key: 'hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}]'
trends: '0'
description: |
MIB: CPQHLTH-MIB
The condition of the power supply. This value will be one of the following:
other(1) The status could not be determined or not present.
ok(2) The power supply is operating normally.
degraded(3) A temperature sensor, fan or other power supply component is outside of normal operating range.
failed(4) A power supply component detects a condition that could permanently damage the system.
valuemap:
name: 'CPQSINFO-MIB::status'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: psu
trigger_prototypes:
- uuid: c0976740671a4ee1b524b2be84eac05f
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.CRIT}'
name: 'HPE ProLiant BL460: Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors.'
tags:
- tag: scope
value: available
- uuid: 4245fe8df0ec42fb8698cd54810357d0
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.WARN}'
name: 'HPE ProLiant BL460: Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors.'
dependencies:
- name: 'HPE ProLiant BL460: Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical state'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.CRIT}'
tags:
- tag: scope
value: available
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 641f9eebbb134b34960f92037c694802
name: 'Temperature ambient discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]'
key: temp.ambient.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_LOCALE}'
value: '11'
formulaid: A
- macro: '{#SNMPINDEX}'
value: 0\.1
formulaid: B
description: |
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with ambient(11) and 0.1 index filter
item_prototypes:
- uuid: 6d81b9d2bfff4312810a50d340f8ba17
name: 'Ambient: Temperature sensor condition'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]'
description: |
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
valuemap:
name: 'CPQHLTH-MIB::cpqHeTemperatureCondition'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 12ca340ef2cc4d639940375e84fc1384
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 1'
name: 'HPE ProLiant BL460: Ambient: Temperature could not be determined'
priority: INFO
description: 'Temperature could not be determined.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 83775e86b0b6450399f0739bcd7aeb42
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 4'
name: 'HPE ProLiant BL460: Ambient: The temperature sensor detects a condition that could permanently damage the system.'
priority: HIGH
description: 'The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.'
tags:
- tag: scope
value: available
- uuid: 1e61e8b2ba4346f2962a3498a147f65e
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 3'
name: 'HPE ProLiant BL460: Ambient: The temperature sensor is outside of normal operating range'
priority: WARNING
description: 'If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.'
tags:
- tag: scope
value: available
- uuid: 1cfee00e1b4d49528589520036b4bf8d
name: 'Ambient: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.value[cpqHeTemperatureCelsius.Ambient.{#SNMPINDEX}]'
value_type: FLOAT
units: °C
description: |
MIB: CPQHLTH-MIB
Temperature readings of testpoint: Ambient
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: aa4918f21cf14e2c94ac155ac3a0b0b4
name: 'Temperature CPU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]'
key: temp.cpu.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_LOCALE}'
value: '6'
formulaid: A
description: |
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with cpu(6) filter
item_prototypes:
- uuid: 0fa15e127d03487cb4fbfaaaacf4fe96
name: 'CPU-{#SNMPINDEX}: Temperature sensor condition'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]'
description: |
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
valuemap:
name: 'CPQHLTH-MIB::cpqHeTemperatureCondition'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: cpu
- tag: component
value: temperature
trigger_prototypes:
- uuid: b3b17ce8480f4ff5bbc4cba02e53190d
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 1'
name: 'HPE ProLiant BL460: CPU-{#SNMPINDEX}: Temperature could not be determined'
priority: INFO
description: 'Temperature could not be determined.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 1d2cc0b823134b9b901a0292e731f882
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 4'
name: 'HPE ProLiant BL460: CPU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.'
priority: HIGH
description: 'The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.'
tags:
- tag: scope
value: available
- uuid: c9edcad3712d4915a5a3700916621525
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 3'
name: 'HPE ProLiant BL460: CPU-{#SNMPINDEX}: The temperature sensor is outside of normal operating range'
priority: WARNING
description: 'If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.'
tags:
- tag: scope
value: available
- uuid: 4f67a2ca1b9d4b179770558df5b8edb7
name: 'CPU-{#SNMPINDEX}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.value[cpqHeTemperatureCelsius.CPU.{#SNMPINDEX}]'
value_type: FLOAT
units: °C
description: |
MIB: CPQHLTH-MIB
Temperature readings of testpoint: CPU-{#SNMPINDEX}
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: cpu
- tag: component
value: temperature
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: c3b3cfe6aa4c47d0ab66b9a969df85bd
name: 'Temperature discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]'
key: temp.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_LOCALE}'
value: (4|8|9|12|13)
formulaid: A
description: |
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable
item_prototypes:
- uuid: 4f13e0a5d45e4847931829f9abd30795
name: '{#SNMPINDEX}: Temperature sensor condition'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]'
description: |
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
valuemap:
name: 'CPQHLTH-MIB::cpqHeTemperatureCondition'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 1978105618f44f439f40b7e6b7dbb5dc
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 1'
name: 'HPE ProLiant BL460: {#SNMPINDEX}: Temperature could not be determined'
priority: INFO
description: 'Temperature could not be determined.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: feee1c3e792044ecbb07ffed47b2fddd
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 4'
name: 'HPE ProLiant BL460: {#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.'
priority: HIGH
description: 'The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.'
tags:
- tag: scope
value: available
- uuid: 250291ba7b404dd287b14034145d7ee0
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 3'
name: 'HPE ProLiant BL460: {#SNMPINDEX}: The temperature sensor is outside of normal operating range'
priority: WARNING
description: 'If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.'
tags:
- tag: scope
value: available
- uuid: c21a7b49d03f4b2e9c532777d4931236
name: '{#SNMPINDEX}: Temperature sensor location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.3.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.locale[cpqHeTemperatureLocale.{#SNMPINDEX}]'
description: |
MIB: CPQHLTH-MIB
This specifies the location of the temperature sensor present in the system.
valuemap:
name: 'CPQHLTH-MIB::cpqHeTemperatureLocale'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
- uuid: 8ac8567f26884cab9d175d9f9934d575
name: '{#SNMPINDEX}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.value[cpqHeTemperatureCelsius.{#SNMPINDEX}]'
value_type: FLOAT
units: °C
description: |
MIB: CPQHLTH-MIB
Temperature readings of testpoint: {#SNMPINDEX}
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: be33f30661ba4c3e88ace96906b0a74c
name: 'Temperature I/O discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]'
key: temp.io.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_LOCALE}'
value: '5'
formulaid: A
description: |
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with ioBoard(5) filter
item_prototypes:
- uuid: 0addee41af6e489fbf2a9747d9cab50e
name: 'I/O-{#SNMPINDEX}: Temperature sensor condition'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]'
description: |
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
valuemap:
name: 'CPQHLTH-MIB::cpqHeTemperatureCondition'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 2d06da621e5946ea88bf158cabd4fcbd
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 1'
name: 'HPE ProLiant BL460: I/O-{#SNMPINDEX}: Temperature could not be determined'
priority: INFO
description: 'Temperature could not be determined.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 5ca16e1ea7d84aa7bed31ba05f7df50e
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 4'
name: 'HPE ProLiant BL460: I/O-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.'
priority: HIGH
description: 'The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.'
tags:
- tag: scope
value: available
- uuid: 8a2468bf1cd14065af733b0d045c6031
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 3'
name: 'HPE ProLiant BL460: I/O-{#SNMPINDEX}: The temperature sensor is outside of normal operating range'
priority: WARNING
description: 'If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.'
tags:
- tag: scope
value: available
- uuid: 2fa250ea6f1e472d9e90984d0918c50d
name: 'I/O-{#SNMPINDEX}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.value[cpqHeTemperatureCelsius."I/O.{#SNMPINDEX}"]'
value_type: FLOAT
units: °C
description: |
MIB: CPQHLTH-MIB
Temperature readings of testpoint: I/O-{#SNMPINDEX}
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: d4dc4e4e6fab415baae36e98877205c5
name: 'Temperature memory discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]'
key: temp.memory.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_LOCALE}'
value: '7'
formulaid: A
description: |
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with memory(7) filter
item_prototypes:
- uuid: 8468b9ca183e44569f6d467f7d103b11
name: 'Memory-{#SNMPINDEX}: Temperature sensor condition'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]'
description: |
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
valuemap:
name: 'CPQHLTH-MIB::cpqHeTemperatureCondition'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: memory
- tag: component
value: temperature
trigger_prototypes:
- uuid: 997f65c5ee1d473dbe22a8517091cf3e
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 1'
name: 'HPE ProLiant BL460: Memory-{#SNMPINDEX}: Temperature could not be determined'
priority: INFO
description: 'Temperature could not be determined.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 8c3b5591160e4797ae1b49f9f14439ff
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 4'
name: 'HPE ProLiant BL460: Memory-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.'
priority: HIGH
description: 'The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.'
tags:
- tag: scope
value: available
- uuid: 8665b434ba594073bc55f44b668dcee0
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 3'
name: 'HPE ProLiant BL460: Memory-{#SNMPINDEX}: The temperature sensor is outside of normal operating range'
priority: WARNING
description: 'If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.'
tags:
- tag: scope
value: available
- uuid: 7441c5de35fd4ff2b6a20c1896525bd4
name: 'Memory-{#SNMPINDEX}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.value[cpqHeTemperatureCelsius.Memory.{#SNMPINDEX}]'
value_type: FLOAT
units: °C
description: |
MIB: CPQHLTH-MIB
Temperature readings of testpoint: Memory-{#SNMPINDEX}
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: memory
- tag: component
value: temperature
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 6df0ad42b4c74a19b9bdfc240db626bb
name: 'Temperature PSU discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]'
key: temp.psu.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_LOCALE}'
value: '10'
formulaid: A
description: |
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with powerSupply(10) filter
item_prototypes:
- uuid: 222d768e05d442ecb12a4cc83100438d
name: 'PSU-{#SNMPINDEX}: Temperature sensor condition'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]'
description: |
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
valuemap:
name: 'CPQHLTH-MIB::cpqHeTemperatureCondition'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: psu
- tag: component
value: temperature
trigger_prototypes:
- uuid: a292c5aaa1b3428aa4b011854d9c5e1d
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 1'
name: 'HPE ProLiant BL460: PSU-{#SNMPINDEX}: Temperature could not be determined'
priority: INFO
description: 'Temperature could not be determined.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: f557d93b186b42b4931e23640e54648f
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 4'
name: 'HPE ProLiant BL460: PSU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.'
priority: HIGH
description: 'The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.'
tags:
- tag: scope
value: available
- uuid: e3cac6176199401181fbbeacf4838bad
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 3'
name: 'HPE ProLiant BL460: PSU-{#SNMPINDEX}: The temperature sensor is outside of normal operating range'
priority: WARNING
description: 'If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.'
tags:
- tag: scope
value: available
- uuid: ca1e5c260caa48368fa299a9dc007512
name: 'PSU-{#SNMPINDEX}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.value[cpqHeTemperatureCelsius.PSU.{#SNMPINDEX}]'
value_type: FLOAT
units: °C
description: |
MIB: CPQHLTH-MIB
Temperature readings of testpoint: PSU-{#SNMPINDEX}
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: psu
- tag: component
value: temperature
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: dfa25ab78aab4cf081e3857f2a40dee4
name: 'Temperature system discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.6.2.6.8.1.1,{#SENSOR_LOCALE},1.3.6.1.4.1.232.6.2.6.8.1.3]'
key: temp.system.discovery
delay: 1h
filter:
conditions:
- macro: '{#SENSOR_LOCALE}'
value: '3'
formulaid: A
description: |
Scanning table of Temperature Sensor Entries:
CPQHLTH-MIB::cpqHeTemperatureTable with system(3) filter
item_prototypes:
- uuid: 10f22e6ea868460c98cc97f24a6c83e4
name: 'System-{#SNMPINDEX}: Temperature sensor condition'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.6.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]'
description: |
MIB: CPQHLTH-MIB
The Temperature sensor condition.
This value will be one of the following:
other(1)
Temperature could not be determined.
ok(2)
The temperature sensor is within normal operating range.
degraded(3)
The temperature sensor is outside of normal operating range.
failed(4)
The temperature sensor detects a condition that could
permanently damage the system.
The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.
valuemap:
name: 'CPQHLTH-MIB::cpqHeTemperatureCondition'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 1bad1b13dcdf4689b9a784e44726196b
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 1'
name: 'HPE ProLiant BL460: System-{#SNMPINDEX}: Temperature could not be determined'
priority: INFO
description: 'Temperature could not be determined.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 42fff974036d4fb6b9181adf1b3efa09
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 4'
name: 'HPE ProLiant BL460: System-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.'
priority: HIGH
description: 'The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.'
tags:
- tag: scope
value: available
- uuid: d184f774ab614a0b9f1f7ebc82cd1356
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 3'
name: 'HPE ProLiant BL460: System-{#SNMPINDEX}: The temperature sensor is outside of normal operating range'
priority: WARNING
description: 'If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.'
tags:
- tag: scope
value: available
- uuid: e25f6cbbb1d444ff851895b37dfcde5d
name: 'System-{#SNMPINDEX}: Temperature'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.6.2.6.8.1.4.{#SNMPINDEX}]'
key: 'hp.server.sensor.temp.value[cpqHeTemperatureCelsius.System.{#SNMPINDEX}]'
value_type: FLOAT
units: °C
description: |
MIB: CPQHLTH-MIB
Temperature readings of testpoint: System-{#SNMPINDEX}
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: temperature
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 92ab660734234833adfe7108df529c24
name: 'Virtual disk discovery'
type: SNMP_AGENT
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.232.3.2.3.1.1.2,{#DISK_NAME},1.3.6.1.4.1.232.3.2.3.1.1.14]'
key: virtualdisk.discovery
delay: 1h
description: 'CPQIDA-MIB::cpqDaLogDrvTable'
item_prototypes:
- uuid: a468686d8de44b958b26a69b4c8d11ed
name: 'Disk {#SNMPINDEX}({#DISK_NAME}): Layout type'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.3.1.1.3.{#SNMPINDEX}]'
key: 'hp.server.hw.virtualdisk.layout[cpqDaLogDrvFaultTol.{#SNMPINDEX}]'
description: |
Logical Drive Fault Tolerance.
This shows the fault tolerance mode of the logical drive.
valuemap:
name: 'CPQIDA-MIB::cpqDaLogDrvFaultTol'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 1e890df502e04b5ba34b3ddc8d9aea57
name: 'Disk {#SNMPINDEX}({#DISK_NAME}): Disk size'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.3.1.1.9.{#SNMPINDEX}]'
key: 'hp.server.hw.virtualdisk.size[cpqDaLogDrvSize.{#SNMPINDEX}]'
trends: '0'
units: B
description: |
Logical Drive Size.
This is the size of the logical drive in megabytes. This value
is calculated using the value 1,048,576 (2^20) as a megabyte.
Drive manufacturers sometimes use the number 1,000,000 as a
megabyte when giving drive capacities so this value may
differ from the advertised size of a drive.
preprocessing:
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 3702a04cf01a4390805535af4f0b8172
name: 'Disk {#SNMPINDEX}({#DISK_NAME}): Status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.232.3.2.3.1.1.4.{#SNMPINDEX}]'
key: 'hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}]'
description: 'Logical Drive Status.'
valuemap:
name: 'CPQIDA-MIB::cpqDaLogDrvStatus'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
trigger_prototypes:
- uuid: e11c5781a34642c49ad15cdcd71dacc3
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])={$VDISK.STATUS.CRIT}'
name: 'HPE ProLiant BL460: Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failed'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check virtual disk for warnings or errors.'
tags:
- tag: scope
value: available
- uuid: 10f0bdba64184a9389a46b9bab18719a
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])<>{$VDISK.STATUS.OK}'
name: 'HPE ProLiant BL460: Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk is not in OK state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check virtual disk for warnings or errors.'
dependencies:
- name: 'HPE ProLiant BL460: Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failed'
expression: 'last(/HPE ProLiant BL460 by SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])={$VDISK.STATUS.CRIT}'
tags:
- tag: scope
value: available
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: class
value: hardware
- tag: target
value: hp
- tag: target
value: hp-bl460
macros:
- macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}'
value: '7'
description: 'The critical status of the disk array cache battery for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"}'
value: '4'
description: 'The critical status of the disk array cache battery for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"degraded"}'
value: '5'
description: 'The warning status of the disk array cache battery for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"notPresent"}'
value: '6'
description: 'The warning status of the disk array cache battery for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}'
value: '8'
description: 'The critical status of the disk array cache for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.STATUS.OK:"enabled"}'
value: '3'
description: 'The normal status of the disk array cache for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"}'
value: '7'
description: 'The warning status of the disk array cache for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}'
value: '6'
description: 'The warning status of the disk array cache for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"}'
value: '9'
description: 'The warning status of the disk array cache for trigger expression.'
- macro: '{$DISK.ARRAY.CACHE.STATUS.WARN:"invalid"}'
value: '2'
description: 'The warning status of the disk array cache for trigger expression.'
- macro: '{$DISK.ARRAY.STATUS.CRIT}'
value: '4'
description: 'The critical status of the disk array for trigger expression.'
- macro: '{$DISK.ARRAY.STATUS.WARN}'
value: '3'
description: 'The warning status of the disk array for trigger expression.'
- macro: '{$DISK.SMART.STATUS.FAIL:"replaceDrive"}'
value: '3'
description: 'The critical S.M.A.R.T status of the disk for trigger expression.'
- macro: '{$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}'
value: '4'
description: 'The critical S.M.A.R.T status of the disk for trigger expression.'
- macro: '{$DISK.STATUS.FAIL}'
value: '3'
description: 'The critical status of the disk for trigger expression.'
- macro: '{$DISK.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk for trigger expression.'
- macro: '{$FAN.STATUS.CRIT}'
value: '4'
description: 'The critical value of the FAN sensor for trigger expression.'
- macro: '{$FAN.STATUS.WARN}'
value: '3'
description: 'The warning value of the FAN sensor for trigger expression.'
- macro: '{$HEALTH.STATUS.CRIT}'
value: '4'
description: 'The critical status of the health for trigger expression.'
- macro: '{$HEALTH.STATUS.WARN}'
value: '3'
description: 'The warning status of the health for trigger expression.'
- macro: '{$PSU.STATUS.CRIT}'
value: '4'
description: 'The critical value of the PSU sensor for trigger expression.'
- macro: '{$PSU.STATUS.WARN}'
value: '3'
description: 'The warning value of the PSU sensor for trigger expression.'
- macro: '{$SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for SNMP agent availability trigger expression.'
- macro: '{$VDISK.STATUS.CRIT}'
value: '3'
description: 'The critical status of the virtual disk for trigger expression.'
- macro: '{$VDISK.STATUS.OK}'
value: '2'
description: 'The normal status of the virtual disk for trigger expression.'
valuemaps:
- uuid: 1b67de295fef454cb89744b101cf5a19
name: 'CPQHLTH-MIB::cpqHeTemperatureCondition'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: ok
- value: '3'
newvalue: degraded
- value: '4'
newvalue: failed
- uuid: 07d063dcbb3d4f1a8642bfd93afcd327
name: 'CPQHLTH-MIB::cpqHeTemperatureLocale'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: system
- value: '4'
newvalue: systemBoard
- value: '5'
newvalue: ioBoard
- value: '6'
newvalue: cpu
- value: '7'
newvalue: memory
- value: '8'
newvalue: storage
- value: '9'
newvalue: removableMedia
- value: '10'
newvalue: powerSupply
- value: '11'
newvalue: ambient
- value: '12'
newvalue: chassis
- value: '13'
newvalue: bridgeCard
- uuid: 009fd99d3734459285fa037c4a0ca201
name: 'CPQIDA-MIB::cpqDaAccelBattery'
mappings:
- value: '1'
newvalue: Other
- value: '2'
newvalue: Ok
- value: '3'
newvalue: Recharging
- value: '4'
newvalue: Failed
- value: '5'
newvalue: Degraded
- value: '6'
newvalue: 'Not Present'
- value: '7'
newvalue: 'Capacitor failed'
- uuid: e138320082fc4aa69f3b23dad80272b2
name: 'CPQIDA-MIB::cpqDaAccelStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: invalid
- value: '3'
newvalue: enabled
- value: '4'
newvalue: tmpDisabled
- value: '5'
newvalue: permDisabled
- value: '6'
newvalue: cacheModFlashMemNotAttached
- value: '7'
newvalue: cacheModDegradedFailsafeSpeed
- value: '8'
newvalue: cacheModCriticalFailure
- value: '9'
newvalue: cacheReadCacheNotMapped
- uuid: 4891472973f84343ade2c5b61d96fcef
name: 'CPQIDA-MIB::cpqDaCntlrModel'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: ida
- value: '3'
newvalue: idaExpansion
- value: '4'
newvalue: ida-2
- value: '5'
newvalue: smart
- value: '6'
newvalue: smart-2e
- value: '7'
newvalue: smart-2p
- value: '8'
newvalue: smart-2sl
- value: '9'
newvalue: smart-3100es
- value: '10'
newvalue: smart-3200
- value: '11'
newvalue: smart-2dh
- value: '12'
newvalue: smart-221
- value: '13'
newvalue: sa-4250es
- value: '14'
newvalue: sa-4200
- value: '15'
newvalue: sa-integrated
- value: '16'
newvalue: sa-431
- value: '17'
newvalue: sa-5300
- value: '18'
newvalue: raidLc2
- value: '19'
newvalue: sa-5i
- value: '20'
newvalue: sa-532
- value: '21'
newvalue: sa-5312
- value: '22'
newvalue: sa-641
- value: '23'
newvalue: sa-642
- value: '24'
newvalue: sa-6400
- value: '25'
newvalue: sa-6400em
- value: '26'
newvalue: sa-6i
- value: '27'
newvalue: sa-generic
- value: '29'
newvalue: sa-p600
- value: '30'
newvalue: sa-p400
- value: '31'
newvalue: sa-e200
- value: '32'
newvalue: sa-e200i
- value: '33'
newvalue: sa-p400i
- value: '34'
newvalue: sa-p800
- value: '35'
newvalue: sa-e500
- value: '36'
newvalue: sa-p700m
- value: '37'
newvalue: sa-p212
- value: '38'
newvalue: sa-p410
- value: '39'
newvalue: sa-p410i
- value: '40'
newvalue: sa-p411
- value: '41'
newvalue: sa-b110i
- value: '42'
newvalue: sa-p712m
- value: '43'
newvalue: sa-p711m
- value: '44'
newvalue: sa-p812
- value: '45'
newvalue: sw-1210m
- value: '46'
newvalue: sa-p220i
- value: '47'
newvalue: sa-p222
- value: '48'
newvalue: sa-p420
- value: '49'
newvalue: sa-p420i
- value: '50'
newvalue: sa-p421
- value: '51'
newvalue: sa-b320i
- value: '52'
newvalue: sa-p822
- value: '53'
newvalue: sa-p721m
- value: '54'
newvalue: sa-b120i
- value: '55'
newvalue: hps-1224
- value: '56'
newvalue: hps-1228
- value: '57'
newvalue: hps-1228m
- value: '58'
newvalue: sa-p822se
- value: '59'
newvalue: hps-1224e
- value: '60'
newvalue: hps-1228e
- value: '61'
newvalue: hps-1228em
- value: '62'
newvalue: sa-p230i
- value: '63'
newvalue: sa-p430i
- value: '64'
newvalue: sa-p430
- value: '65'
newvalue: sa-p431
- value: '66'
newvalue: sa-p731m
- value: '67'
newvalue: sa-p830i
- value: '68'
newvalue: sa-p830
- value: '69'
newvalue: sa-p831
- value: '70'
newvalue: sa-p530
- value: '71'
newvalue: sa-p531
- value: '72'
newvalue: sa-p244br
- value: '73'
newvalue: sa-p246br
- value: '74'
newvalue: sa-p440
- value: '75'
newvalue: sa-p440ar
- value: '76'
newvalue: sa-p441
- value: '77'
newvalue: sa-p741m
- value: '78'
newvalue: sa-p840
- value: '79'
newvalue: sa-p841
- value: '80'
newvalue: sh-h240ar
- value: '81'
newvalue: sh-h244br
- value: '82'
newvalue: sh-h240
- value: '83'
newvalue: sh-h241
- value: '84'
newvalue: sa-b140i
- value: '85'
newvalue: sh-generic
- value: '86'
newvalue: sa-p240nr
- value: '87'
newvalue: sh-h240nr
- value: '88'
newvalue: sa-p840ar
- value: '89'
newvalue: sa-p542d
- value: '90'
newvalue: s100i
- value: '91'
newvalue: e208i-p
- value: '92'
newvalue: e208i-a
- value: '93'
newvalue: e208i-c
- value: '94'
newvalue: e208e-p
- value: '95'
newvalue: p204i-b
- value: '96'
newvalue: p204i-c
- value: '97'
newvalue: p408i-p
- value: '98'
newvalue: p408i-a
- value: '99'
newvalue: p408e-p
- value: '100'
newvalue: p408i-c
- value: '101'
newvalue: p408e-m
- value: '102'
newvalue: p416ie-m
- value: '103'
newvalue: p816i-a
- value: '104'
newvalue: p408i-sb
- uuid: a368b7472246477599d6278df8348bc9
name: 'CPQIDA-MIB::cpqDaLogDrvFaultTol'
mappings:
- value: '0'
newvalue: other
- value: '2'
newvalue: none
- value: '3'
newvalue: RAID-1/RAID-10
- value: '4'
newvalue: RAID-4
- value: '5'
newvalue: RAID-5
- value: '7'
newvalue: RAID-6
- value: '8'
newvalue: RAID-50
- value: '9'
newvalue: RAID-60
- value: '10'
newvalue: 'RAID-1 ADM'
- value: '11'
newvalue: 'RAID-10 ADM'
- uuid: aab16842347c4e58b9bbee274dad3c62
name: 'CPQIDA-MIB::cpqDaLogDrvStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: ok
- value: '3'
newvalue: failed
- value: '4'
newvalue: unconfigured
- value: '5'
newvalue: recovering
- value: '6'
newvalue: readyForRebuild
- value: '7'
newvalue: rebuilding
- value: '8'
newvalue: wrongDrive
- value: '9'
newvalue: badConnect
- value: '10'
newvalue: overheating
- value: '11'
newvalue: shutdown
- value: '12'
newvalue: expanding
- value: '13'
newvalue: notAvailable
- value: '14'
newvalue: queuedForExpansion
- value: '15'
newvalue: multipathAccessDegraded
- value: '16'
newvalue: erasing
- value: '17'
newvalue: predictiveSpareRebuildReady
- value: '18'
newvalue: rapidParityInitInProgress
- value: '19'
newvalue: rapidParityInitPending
- value: '20'
newvalue: noAccessEncryptedNoCntlrKey
- value: '21'
newvalue: unencryptedToEncryptedInProgress
- value: '22'
newvalue: newLogDrvKeyRekeyInProgress
- value: '23'
newvalue: noAccessEncryptedCntlrEncryptnNotEnbld
- value: '24'
newvalue: unencryptedToEncryptedNotStarted
- value: '25'
newvalue: newLogDrvKeyRekeyRequestReceived
- uuid: b3b110016c8c4272b9228161798a9bbd
name: 'CPQIDA-MIB::cpqDaPhyDrvMediaType'
mappings:
- value: '1'
newvalue: Other
- value: '2'
newvalue: rotatingPlatters
- value: '3'
newvalue: solidState
- uuid: 5b016d244c6845f7afcc80361aec2af1
name: 'CPQIDA-MIB::cpqDaPhyDrvSmartStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: ok
- value: '3'
newvalue: replaceDrive
- value: '4'
newvalue: replaceDriveSSDWearOut
- uuid: 2f4e1eb1f32847b3808372d02f752575
name: 'CPQIDA-MIB::cpqDaPhyDrvStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: ok
- value: '3'
newvalue: failed
- value: '4'
newvalue: predictiveFailure
- uuid: 3fe7ff0237a54f6cae3a1b8ffdabf157
name: 'CPQNIC-MIB::cpqNicIfPhysAdapterStatus'
mappings:
- value: '1'
newvalue: unknown
- value: '2'
newvalue: ok
- value: '3'
newvalue: generalFailure
- value: '4'
newvalue: linkFailure
- uuid: 342d09a1cfe543b9ac1555daee9f2235
name: 'CPQSINFO-MIB::status'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: ok
- value: '3'
newvalue: degraded
- value: '4'
newvalue: failed
- uuid: c57a256a525b46b0a1d0646200de57e2
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 9159ee66dbe4498cba29daca24ddcb5f
expression: '(last(/HPE ProLiant BL460 by SNMP/hp.server.hw.uptime[hrSystemUptime])>0 and last(/HPE ProLiant BL460 by SNMP/hp.server.hw.uptime[hrSystemUptime])<10m) or (last(/HPE ProLiant BL460 by SNMP/hp.server.hw.uptime[hrSystemUptime])=0 and last(/HPE ProLiant BL460 by SNMP/hp.server.net.uptime[sysUpTime])<10m)'
name: 'HPE ProLiant BL460: Host has been restarted'
event_name: 'HPE ProLiant BL460: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
tags:
- tag: scope
value: notice