Files
templates-default/DELL_PowerEdge_R750_by_SNMP.yaml

2609 lines
117 KiB
YAML

zabbix_export:
version: '7.0'
template_groups:
- uuid: e960332b3f6c46a1956486d4f3f99fce
name: 'Templates/Server hardware'
templates:
- uuid: 419145c8af7e4b8eb30af8460bbed566
template: 'DELL PowerEdge R750 by SNMP'
name: 'DELL PowerEdge R750 by SNMP'
description: |
Template for DELL PowerEdge R750 servers with iDRAC version 7 and later.
MIBs used:
HOST-RESOURCES-MIB
IDRAC-MIB-SMIv2
SNMPv2-MIB
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-3
groups:
- name: 'Templates/Server hardware'
items:
- uuid: afe5a32aaab74acc94199a87c8eb893f
name: 'SNMP walk RAID controllers table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]'
key: dell.server.array.controller.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.'
tags:
- tag: component
value: raw
- uuid: 2058910ac68046bcbbe3c541d8493cc6
name: 'SNMP walk Battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]'
key: dell.server.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.'
tags:
- tag: component
value: raw
- uuid: 8369cb7f9e9040eda117ed54acae56ef
name: 'BIOS version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]'
key: dell.server.bios.version
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the version name of the system BIOS.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 1ed40c90dc2a4c329467fcd8796e4826
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: 'dell.server.contact[sysContact]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
Name and contact information of the contact person for the node. If not provided, the value is a zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 5eb47d9d420446cba50d5bdf8ce94ea2
name: 'SNMP walk Processor device tables'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]'
key: dell.server.cpu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.'
tags:
- tag: component
value: raw
- uuid: 6bfce5ab91884d75a8771a6648ab90b5
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: 'dell.server.descr[sysDescr]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: 35400811500f4b7fb3444aebfc8a9bb3
name: 'SNMP walk Physical disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]'
key: dell.server.disk.physical.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.'
tags:
- tag: component
value: raw
- uuid: f2762c4ec5a0488492d312c07d82890f
name: 'SNMP walk Virtual disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]'
key: dell.server.disk.virtual.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.'
tags:
- tag: component
value: raw
- uuid: bbedf912ec7a4b01b6c4c1f6646fe691
name: 'SNMP walk Cooling device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]'
key: dell.server.fan.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 0433d7f60efb429399493383314f7256
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the firmware version of a remote access card.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 3cb240c2c5884c448a7ac399412dc00c
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R750 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R750 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0'
name: 'Dell R750: Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 79dc78b6decf4b8b9769ae834da84513
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]'
key: 'dell.server.hw.model[systemModelName]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the model name of the system.
inventory_link: MODEL
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: bb3b2abb63c84a97ba62a04b943236a9
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the service tag of the system.
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 7e6fb4f6552d4643babba3d650f00c18
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R750 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R750 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0'
name: 'Dell R750: Device has been replaced'
event_name: 'Dell R750: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 578b9267e58d462abb36c0e68fd32dbc
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
trends: '0'
units: uptime
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the power-up time of the system in seconds.
tags:
- tag: component
value: system
- uuid: f09996db69fe484283e45a3117b4d5f0
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: 'dell.server.location[sysLocation]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 37f3d96deb39494e95513361d0ea8183
name: 'Memory, total size'
type: CALCULATED
key: dell.server.memory.size.total
units: B
params: 'sum(last_foreach(//dell.server.memory.size[*]))'
description: 'Total memory amount on the device.'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: memory
triggers:
- uuid: 2f2f224a7ce3481eb04fd5c62530a57d
expression: 'change(/DELL PowerEdge R750 by SNMP/dell.server.memory.size.total)>0'
name: 'Dell R750: Memory amount has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags:
- tag: scope
value: availability
- uuid: 3f9159df646b4036a754969f454b0ce8
name: 'SNMP walk Memory device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]'
key: dell.server.memory.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 09195963d6e74bab98f9cea1adbfbd25
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: 'dell.server.name[sysName]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 45b605bae5bd4bfa8c7ab042a3bde257
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R750 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R750 by SNMP/dell.server.name[sysName]))>0'
name: 'Dell R750: System name has changed'
event_name: 'Dell R750: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 8a9d37b55a7149ce8ac0428e5021ee12
name: 'SNMP walk Network device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]'
key: dell.server.net.if.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 8515f86587ab43a0af94b90a06998ba5
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]'
key: 'dell.server.net.uptime[snmpEngineTime]'
trends: '0'
units: uptime
description: |
MIB: SNMP-FRAMEWORK-MIB
The number of seconds since the value of the snmpEngineBoots object last changed.
tags:
- tag: component
value: system
- uuid: d8abb2af15ad42f2ae3d76df569e1ae0
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: 'dell.server.objectid[sysObjectID]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1).
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 82ab16270c5d4748bc212b69774b8ddc
name: 'SNMP walk Power supply table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]'
key: dell.server.psu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.'
tags:
- tag: component
value: raw
- uuid: ad64ca5196504b48afb43a0954396579
name: 'SNMP walk Temperature sensor table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]'
key: dell.server.sensor.temp.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 24bf18434f2145fe91b6bf6ccf3a5c5d
name: 'Overall system health status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]'
key: 'dell.server.status[globalSystemStatus]'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 58beec6c28a5424a862d427588b74207
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}'
name: 'Dell R750: System is in unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 652439f2023d46bf8ba84d8ac0154ee2
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
name: 'Dell R750: System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for errors.'
tags:
- tag: scope
value: availability
- uuid: 9702a49ff2034f3b98892d93c1060ff1
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}'
name: 'Dell R750: System status is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for warnings.'
dependencies:
- name: 'Dell R750: System status is in critical state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
tags:
- tag: scope
value: availability
- uuid: abed403c12404de3b6df8335324eddf3
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]'
key: 'dell.server.sw.os[systemOSName]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the name of the operating system that the host is running.
inventory_link: OS
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 2c37e6ae35404da199844a685b2ed28f
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R750 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R750 by SNMP/dell.server.sw.os[systemOSName]))>0'
name: 'Dell R750: Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 391180d5461c4f448724b22cacc12036
name: 'SNMP walk System battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]'
key: dell.server.system.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.'
tags:
- tag: component
value: raw
- uuid: 0dc203875c6541e48f8418c4806461dd
name: 'SNMP walk Voltage probe table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]'
key: dell.server.voltage.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 575229ede65e4639a4113ef078ed33d2
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: network
- uuid: c164ae420f1a49d2a205ecbe2eb1d892
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
description: |
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
Possible values:
0 - not available
1 - available
2 - unknown
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 22caee353f3f4b74a150f8144f73eab2
expression: 'max(/DELL PowerEdge R750 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0'
name: 'Dell R750: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: f53489a8b45a4cf7bdb9bb7cdc70476c
name: 'Array controller discovery'
type: DEPENDENT
key: array.discovery
delay: '0'
description: 'Array controller discovery.'
item_prototypes:
- uuid: b1791e524e8e4c3fa0d436a30aa48e26
name: 'Controller [{#CNTLR_NAME}]: Model'
type: DEPENDENT
key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The controller's name as represented in Storage Management.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
- uuid: c0a6d4b50f7a4d98884526adc0282d65
name: 'Controller [{#CNTLR_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the controller itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
trigger_prototypes:
- uuid: 45ee39d107794f8584960b2a29ae24b6
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
name: 'Dell R750: Controller [{#CNTLR_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R750: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
- uuid: c4bee8d38f5c466ba2dbf5c283e50b22
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
name: 'Dell R750: Controller [{#CNTLR_NAME}]: Unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 45546a22e8bf4c4c956efcc9bccd8f1e
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
name: 'Dell R750: Controller [{#CNTLR_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R750: Controller [{#CNTLR_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
- name: 'Dell R750: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.array.controller.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38
- '0'
- '{#CNTLR_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: e6ed622097f143a2abc8ab7c96f2fa85
name: 'Battery discovery'
type: DEPENDENT
key: battery.discovery
delay: '0'
description: 'Battery discovery.'
item_prototypes:
- uuid: 32a7aeec4f714456bcda1c85b20ff8b2
name: 'Battery [{#BATTERY_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Current state of battery.
Possible values:
1: The current state could not be determined.
2: The battery is operating normally.
3: The battery has failed and needs to be replaced.
4: The battery temperature is high or charge level is depleting.
5: The battery is missing or not detected.
6: The battery is undergoing the re-charge phase.
7: The battery voltage or charge level is below the threshold.
valuemap:
name: 'IDRAC-MIB-SMIv2::batteryState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.battery.walk
tags:
- tag: component
value: battery
- tag: component
value: diskarray
trigger_prototypes:
- uuid: 067d23b901264566a7c9286167e0bdc8
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
name: 'Dell R750: Battery [{#BATTERY_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: f304da869b0f4c7d9c0bc0c648399770
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
name: 'Dell R750: Battery [{#BATTERY_NAME}]: Not in optimal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R750: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
- name: 'Dell R750: Battery [{#BATTERY_NAME}]: Warning state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
tags:
- tag: scope
value: availability
- uuid: 441c7e48188f4dd584cb5cfefb8b7d12
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
name: 'Dell R750: Battery [{#BATTERY_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R750: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#BATTERY_NUM}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1
- '0'
- '{#BATTERY_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 8ab8bef701d048e69a73f040ad1af21a
name: 'CPU status discovery'
type: DEPENDENT
key: cpu.discovery
delay: '0'
description: 'CPU status discovery.'
item_prototypes:
- uuid: 21638c22932b4902935cded381ecd8da
name: 'CPU [{#CPU_FQDD}]: State'
type: DEPENDENT
key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the reading of the processor device status probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: b6ab5fa13e0b4addb6bdb7054484905d
expression: 'bitand(last(/DELL PowerEdge R750 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0'
name: 'Dell R750: CPU [{#CPU_FQDD}]: Reading error'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU probe reading flag is not `processorPresent`.
tags:
- tag: scope
value: availability
- uuid: 82ee2aef57234c2a895abb12a88fa080
name: 'CPU [{#CPU_FQDD}]: Status'
type: DEPENDENT
key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: cc4ce4de33484554b08466e06dee03ad
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3'
name: 'Dell R750: CPU [{#CPU_FQDD}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.cpu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#CPU_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: d94dca2ced174c64be2c2320ea02ab5e
name: 'Fan discovery'
type: DEPENDENT
key: fan.discovery
delay: '0'
filter:
conditions:
- macro: '{#TYPE}'
value: '3'
formulaid: A
description: 'Fan discovery.'
item_prototypes:
- uuid: 64f790383afd4bc095111260afca2a3c
name: 'Fan [{#FAN_DESCR}]: Speed'
type: DEPENDENT
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
delay: '0'
units: rpm
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`.
When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device.
When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
- uuid: 803def961ff6436098d04b1d3b071cfe
name: 'Fan [{#FAN_DESCR}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the cooling device.
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
trigger_prototypes:
- uuid: 63aa1fdbf4b34dca9ce5e4de80b2b669
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
name: 'Dell R750: Fan [{#FAN_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit.'
tags:
- tag: scope
value: availability
- uuid: 2c72a8abf92e41ae9775651d2804dd15
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R750: Fan [{#FAN_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit.'
dependencies:
- name: 'Dell R750: Fan [{#FAN_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: e666babd7a6b4e4794cbf60fb6efd1df
name: 'Dell R750: Fan [{#FAN_DESCR}]: Speed'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
master_item:
key: dell.server.fan.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.5
- '0'
- '{#FAN_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.8
- '0'
- '{#TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.7
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 3dce052999be497ca8aaf114f95919e8
name: 'Memory discovery'
type: DEPENDENT
key: memory.discovery
delay: '0'
description: 'Memory discovery.'
item_prototypes:
- uuid: 552d15f0d4e34855aaa003596d2af728
name: 'Memory [{#SNMPVALUE}]: Size'
type: DEPENDENT
key: 'dell.server.memory.size[{#SNMPVALUE}]'
delay: '0'
units: B
description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- type: MULTIPLIER
parameters:
- '1024'
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
- uuid: da00461cfcfd414385b8ef028a4443ab
name: 'Memory [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.memory.status[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the memory device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
trigger_prototypes:
- uuid: 240b28c42d24459ca26ad2b3b1918d99
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3'
name: 'Dell R750: Memory [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Memory status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.memory.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 12fcb06f08494037beffa958fcc1d29d
name: 'Network interface discovery'
type: DEPENDENT
key: net.if.discovery
delay: '0'
description: 'Discovery of network interfaces.'
item_prototypes:
- uuid: 3138082ae9914ab4ac5581bb5dcb045a
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status'
type: DEPENDENT
key: 'dell.server.net.if.link[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the connection status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: 153bad63b97d4d439b0ef110c37633d4
expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R750 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R750 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R750 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0'
name: 'Dell R750: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is Down.
2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down.
3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.)
manual_close: 'YES'
tags:
- tag: scope
value: availability
- uuid: 185b1e4d16a64c0ca999631364364462
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status'
type: DEPENDENT
key: 'dell.server.net.if.status[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: cc9b9a8e8f1541a98a4be1b1f119dc7b
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3'
name: 'Dell R750: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Network interface status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.net.if.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#NIC_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1
- '0'
- '{#NIC_MAC}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1
- '2'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: c68af0c8ed7f4cabbf9da31f0c35d728
name: 'Physical disk discovery'
type: DEPENDENT
key: physicaldisk.discovery
delay: '0'
description: 'Physical disk discovery.'
item_prototypes:
- uuid: e388e6b6999b448bb8c01442e707c510
name: 'Physical disk [{#DISK_NAME}]: Media type'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The media type of the physical disk. Possible Values:
1: The media type could not be determined.
2: Hard Disk Drive (HDD).
3: Solid State Drive (SSD).
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 6e1632c7c9524c0bb1c6d47d0dff04f8
name: 'Physical disk [{#DISK_NAME}]: Model name'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The model number of the physical disk.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: b30d7f393f394eb7838c0152721e7666
name: 'Physical disk [{#DISK_NAME}]: Serial number'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The physical disk's unique identification number from the manufacturer.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: e120cd2329ea4a659c66ccc4ac46747a
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0'
name: 'Dell R750: Physical disk [{#DISK_NAME}] has been replaced'
event_name: 'Dell R750: [{#DISK_NAME}] has been replaced (new serial number received)'
priority: INFO
description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 20559cb3035c4dac865549a94b1d8d9d
name: 'Physical disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the physical disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: bdf2526c88df45b98eaf0e99b599a84f
name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Indicates whether the physical disk has received a predictive failure alert.
valuemap:
name: 'IDRAC-MIB-SMIv2::BooleanType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 8bbead4d14754d9b88bf8304176c7bff
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}'
name: 'Dell R750: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Disk probably requires replacement.'
dependencies:
- name: 'Dell R750: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
- uuid: 7bb9177022064d278ed2255a46238c72
name: 'Physical disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the physical disk itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 5ba3472c708444d0b8ed1bfec7557baf
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
name: 'Dell R750: Physical disk [{#DISK_NAME}]: Failed state'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check physical disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: bb250a8fe19d4d319b9b1c6d10c04774
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
name: 'Dell R750: Physical disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check physical disk for warnings or errors.'
dependencies:
- name: 'Dell R750: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R750 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 69ca1bbae9134f0da26c6cf926c35722
name: 'Dell R750: Physical disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.physical.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: f3ff069a229d43c39ab3a315f00b8f3a
name: 'PSU discovery'
type: DEPENDENT
key: psu.discovery
delay: '0'
description: 'PSU discovery.'
item_prototypes:
- uuid: f7421fa124af4654bb1c4d5a29541d1d
name: 'Power supply [{#PSU_DESCR}]: State'
type: DEPENDENT
key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the status of the power supply.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.psu.walk
tags:
- tag: component
value: psu
trigger_prototypes:
- uuid: 9653ab9642d649aca556a0daee76209c
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
name: 'Dell R750: Power supply [{#PSU_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors.'
tags:
- tag: scope
value: availability
- uuid: e29d34bc586a456691c835149b17d270
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
name: 'Dell R750: Power supply [{#PSU_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors.'
dependencies:
- name: 'Dell R750: Power supply [{#PSU_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.psu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
- '0'
- '{#PSU_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 01b77de5966b40b684479fe65c2fc3f1
name: 'System battery discovery'
type: DEPENDENT
key: system.battery.discovery
delay: '0'
description: 'System battery discovery.'
item_prototypes:
- uuid: 31de734882e54920b74f214ce3d96f54
name: 'System battery [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.system.battery[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the battery.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.system.battery.walk
tags:
- tag: component
value: battery
trigger_prototypes:
- uuid: 513785a5de094c57a5b20a7a4e1db042
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3'
name: 'Dell R750: System battery [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
System battery status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.system.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 1580a53d7d804d99a3e1cd1bd66af855
name: 'Temperature discovery'
type: DEPENDENT
key: temp.discovery
delay: '0'
description: 'Temperature sensor discovery.'
item_prototypes:
- uuid: b4b80de974e7488c977ede41c75e0c21
name: 'Probe [{#SENSOR_LOCALE}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the temperature probe.
Possible values:
other(1), -- probe status is not one of the following:
unknown(2), -- probe status is unknown (not known or monitored)
ok(3), -- probe is reporting a value within the thresholds
nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold
criticalUpper(5), -- probe has crossed the upper critical threshold
nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold
nonCriticalLower(7), -- probe has crossed the lower noncritical threshold
criticalLower(8), -- probe has crossed the lower critical threshold
nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold
failed(10) -- probe is not functional
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: 5fbbf20cc4114bcea47591e925a1b92c
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
name: 'Dell R750: Probe [{#SENSOR_LOCALE}]: Critical status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: f16c3c5630c7493cba96d973e71b56f3
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
name: 'Dell R750: Probe [{#SENSOR_LOCALE}]: Not in optimal status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
manual_close: 'YES'
dependencies:
- name: 'Dell R750: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
- name: 'Dell R750: Probe [{#SENSOR_LOCALE}]: Warning status'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
tags:
- tag: scope
value: notice
- uuid: e6635984c5764d78bc494d067382b452
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R750: Probe [{#SENSOR_LOCALE}]: Warning status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R750: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R750 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
tags:
- tag: scope
value: availability
- uuid: ae6ba617d2dd47a288d716e2220a4b45
name: 'Probe [{#SENSOR_LOCALE}]: Value'
type: DEPENDENT
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
units: °C
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`.
When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade.
When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.1'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
graph_prototypes:
- uuid: 5e901b5fc45c4000948a857441691f7d
name: 'Dell R750: Probe [{#SENSOR_LOCALE}]: Value'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
master_item:
key: dell.server.sensor.temp.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
- '0'
- '{#SENSOR_LOCALE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: a5b9d53f6c4f4202b4a525e023a1ce3b
name: 'Virtual disk discovery'
type: DEPENDENT
key: virtualdisk.discovery
delay: '0'
description: 'Virtual disk discovery.'
item_prototypes:
- uuid: 3d44e650016747f18d485089da592d1a
name: 'Virtual disk [{#DISK_NAME}]: Layout type'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The virtual disk's RAID type.
Possible values:
1: Not one of the following
2: RAID-0
3: RAID-1
4: RAID-5
5: RAID-6
6: RAID-10
7: RAID-50
8: RAID-60
9: Concatenated RAID 1
10: Concatenated RAID 5
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 8e5d1124cfe042c69a400ce18b78f0a9
name: 'Virtual disk [{#DISK_NAME}]: Read policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The read policy used by the controller for read operations on this virtual disk.
Possible values:
1: No Read Ahead.
2: Read Ahead.
3: Adaptive Read Ahead.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: feaee5bce10b4343b1979f981a41fa08
name: 'Virtual disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the virtual disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 1ab64a043c7c49babbc38baf9c15ba6b
name: 'Virtual disk [{#DISK_NAME}]: Operational state'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The state of the virtual disk when there are progressive operations ongoing.
Possible values:
1: There is no active operation running.
2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.
3: A Consistency Check (CC) is being performed on the virtual disk.
4: The virtual disk is being initialized.
5: BackGround Initialization (BGI) is being performed on the virtual disk.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 3m
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: f0858440aca347fb9e4bd3f8a425e44f
name: 'Virtual disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The current state of this virtual disk (which includes any member physical disks.)
Possible states:
1: The current state could not be determined.
2: The virtual disk is operating normally or optimally.
3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost.
4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.
The data on the virtual disk might no longer be fault tolerant.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
trigger_prototypes:
- uuid: 137578978eae4687902fb0d156b24599
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
name: 'Dell R750: Virtual disk [{#DISK_NAME}]: Failed state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the virtual disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: 64b3ede11df34c48b0d5576a3f4afed2
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
name: 'Dell R750: Virtual disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the virtual disk for warnings or errors.'
dependencies:
- name: 'Dell R750: Virtual disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
- uuid: b92c8b659e424cf6befe2ab8ba1ebfd8
name: 'Virtual disk [{#DISK_NAME}]: Write policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The write policy used by the controller for write operations on this virtual disk.
Possible values:
1: Write Through.
2: Write Back.
3: Force Write Back.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
graph_prototypes:
- uuid: c8acd3090578488f9772d4d8e50d2082
name: 'Dell R750: Virtual disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.virtual.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 609fe55d31344073b69f2d5972d36c96
name: 'Voltage probe discovery'
type: DEPENDENT
key: voltage.discovery
delay: '0'
filter:
evaltype: AND
conditions:
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
formulaid: A
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
formulaid: C
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
description: 'Voltage probe discovery.'
item_prototypes:
- uuid: 4de5e5a4fab24acf9804d41cb14ae0bd
name: 'Voltage probe [{#VPROBE_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.voltage.status[{#VPROBE_NAME}]'
delay: '0'
description: 'This attribute defines the status of the voltage probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
trigger_prototypes:
- uuid: d363ebd012514cf691c18e38d6e7a9c9
expression: 'last(/DELL PowerEdge R750 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3'
name: 'Dell R750: Voltage probe [{#VPROBE_NAME}]: Status is not OK'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device''s voltage.'
tags:
- tag: scope
value: availability
- uuid: 5210d34f8ce944b2bf63be2fd9ce176b
name: 'Voltage probe [{#VPROBE_NAME}]: Voltage'
type: DEPENDENT
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
delay: '0'
value_type: FLOAT
units: V
description: 'This attribute defines the reading for a voltage probe.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.001'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
graph_prototypes:
- uuid: 82d83fc0210443678ed4221d1cd50caa
name: 'Dell R750: Voltage probe [{#VPROBE_NAME}]: Voltage'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
master_item:
key: dell.server.voltage.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#VPROBE_NAME}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1
- '0'
- '{#VPROBE_TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: class
value: hardware
- tag: target
value: dell
- tag: target
value: 'dell poweredge'
macros:
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
value: '^.*Voltage.*$'
description: 'Sets the regex string of voltage probe names to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe names to ignore in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
value: 18|16
description: 'Sets the regex string of voltage probe types to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe types to ignore in discovery.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
value: '3'
description: 'The critical status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
value: '2'
description: 'The OK status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
value: '5'
description: 'The critical status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
value: '6'
description: 'The disaster status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}'
value: '1'
description: 'The critical S.M.A.R.T status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}'
value: '5'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
value: '6'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
value: '10'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}'
value: '5'
description: 'The critical status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}'
value: '6'
description: 'The disaster status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}'
value: '4'
description: 'The warning status of health for the trigger expression.'
- macro: '{$DELL.SNMP.IFCONTROL}'
value: '1'
description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}'
value: '5'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
value: '6'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
value: '3'
description: 'The OK status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for the SNMP agent availability trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
value: '3'
description: 'The critical status of the virtual disk for the trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
value: '4'
description: 'The warning status of the virtual disk for the trigger expression.'
dashboards:
- uuid: 85cfa4c83cb44563890b75ecbc6091a4
name: Overview
pages:
- name: Overview
display_period: '30'
widgets:
- type: item
name: 'System health'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'System Health'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.status[globalSystemStatus]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'Serial number'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'Serial number'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'HW model'
x: '36'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'HW model'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.hw.model[systemModelName]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: Firmware
x: '36'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: Firmware
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- name: Discoveries
display_period: '30'
widgets:
- type: honeycomb
name: 'Interface link'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'NIC*Link status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAA
- type: STRING
name: thresholds.0.color
value: 069C56
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: FF681E
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: 'Temperature sensors'
'y': '4'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Probe*Value'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAB
- type: INTEGER
name: secondary_label_decimal_places
value: '0'
- type: honeycomb
name: 'Physical disks'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Physical disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAC
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
- type: honeycomb
name: 'Power supplies'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Voltage probe*Voltage'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAE
- type: honeycomb
name: 'Virtual disks'
x: '36'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Virtual disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAD
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: Fans
x: '36'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Fan*Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAF
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
valuemaps:
- uuid: 44ae746465504433b126a6ad47867539
name: 'IDRAC-MIB-SMIv2::batteryState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Ready
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- value: '5'
newvalue: Missing
- value: '6'
newvalue: Charging
- value: '7'
newvalue: 'Below threshold'
- uuid: 540df39092da4d0ba419d9225b6855e5
name: 'IDRAC-MIB-SMIv2::BooleanType'
mappings:
- value: '0'
newvalue: ok
- value: '1'
newvalue: failed
- uuid: bcd3842a7f14414786e7e893bf18033f
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
mappings:
- value: '0'
newvalue: unknown
- value: '1'
newvalue: connected
- value: '2'
newvalue: disconnected
- value: '3'
newvalue: driverBad
- value: '4'
newvalue: driverDisabled
- value: '10'
newvalue: hardwareInitalizing
- value: '11'
newvalue: hardwareResetting
- value: '12'
newvalue: hardwareClosing
- value: '13'
newvalue: hardwareNotReady
- uuid: 0e8b14fc00af4ec1b098b1dad64bbf12
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: 7c02091fa34847cb8571066c5f1ccfd3
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: a0c2ee107bc24efba036b01f8aa16c03
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: HDD
- value: '3'
newvalue: SSD
- uuid: b7f4bdede53e44ada2841fb5d39793db
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
mappings:
- value: '1'
newvalue: internalError
- value: '2'
newvalue: thermalTrip
- value: '32'
newvalue: configurationError
- value: '128'
newvalue: processorPresent
- value: '256'
newvalue: processorDisabled
- value: '512'
newvalue: terminatorPresent
- value: '1024'
newvalue: processorThrottled
- uuid: 1b7e62b02f6d4b9aad5e81de0792037e
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCriticalUpper
- value: '5'
newvalue: criticalUpper
- value: '6'
newvalue: nonRecoverableUpper
- value: '7'
newvalue: nonCriticalLower
- value: '8'
newvalue: criticalLower
- value: '9'
newvalue: nonRecoverableLower
- value: '10'
newvalue: failed
- uuid: f3ed0698bf4448ad9927f193aa804365
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
mappings:
- value: '1'
newvalue: Other
- value: '2'
newvalue: RAID-0
- value: '3'
newvalue: RAID-1
- value: '4'
newvalue: RAID-5
- value: '5'
newvalue: RAID-6
- value: '6'
newvalue: RAID-10
- value: '7'
newvalue: RAID-50
- value: '8'
newvalue: RAID-60
- value: '9'
newvalue: 'Concatenated RAID 1'
- value: '10'
newvalue: 'Concatenated RAID 5'
- uuid: 5e0085d3c952446a8fb9603b074d720f
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
mappings:
- value: '1'
newvalue: 'Not applicable'
- value: '2'
newvalue: Reconstructing
- value: '3'
newvalue: Resynching
- value: '4'
newvalue: Initializing
- value: '5'
newvalue: 'Background init'
- uuid: 65fbf402163e494aa59a7dc814a038f9
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
mappings:
- value: '1'
newvalue: 'No Read Ahead'
- value: '2'
newvalue: 'Read Ahead'
- value: '3'
newvalue: 'Adaptive Read Ahead'
- uuid: ce091236ac5c461da03712a39e97676b
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Online
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- uuid: d30e0073fbab42ecbb1c4ab74ad1f991
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
mappings:
- value: '1'
newvalue: 'Write Through'
- value: '2'
newvalue: 'Write Back'
- value: '3'
newvalue: 'Force Write Back'
- uuid: f5c3e47da21c4fd8ac4fd2c079ebd28b
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 0eb0e7489c6a4e6b8a44fc2eae500006
expression: '(last(/DELL PowerEdge R750 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R750 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R750 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R750 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)'
name: 'Dell R750: Host has been restarted'
event_name: 'Dell R750: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
graphs:
- uuid: ea6ee813804a4eb1863bb631535f6c8c
name: 'Dell R750: Uptime'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
- sortorder: '1'
color: F63100
item:
host: 'DELL PowerEdge R750 by SNMP'
key: 'dell.server.net.uptime[snmpEngineTime]'