Files
templates-default/DELL_PowerEdge_R660_by_SNMP.yaml

2609 lines
117 KiB
YAML

zabbix_export:
version: '7.0'
template_groups:
- uuid: e960332b3f6c46a1956486d4f3f99fce
name: 'Templates/Server hardware'
templates:
- uuid: 3ba7dec7c0034d86ad1c73b4f8ee8994
template: 'DELL PowerEdge R660 by SNMP'
name: 'DELL PowerEdge R660 by SNMP'
description: |
Template for DELL PowerEdge R660 servers with iDRAC version 7 and later.
MIBs used:
HOST-RESOURCES-MIB
IDRAC-MIB-SMIv2
SNMPv2-MIB
You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates
Generated by official Zabbix template tool "Templator"
vendor:
name: Zabbix
version: 7.0-3
groups:
- name: 'Templates/Server hardware'
items:
- uuid: 28e0c3b6ff414e8ea580a5efedd6d966
name: 'SNMP walk RAID controllers table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]'
key: dell.server.array.controller.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.'
tags:
- tag: component
value: raw
- uuid: 4c75b80b0f224d02a835794592bb1df9
name: 'SNMP walk Battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]'
key: dell.server.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.'
tags:
- tag: component
value: raw
- uuid: 10c7c6dfa9d645d19595f143cbeafb18
name: 'BIOS version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]'
key: dell.server.bios.version
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the version name of the system BIOS.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 543172398a8a46238b3b2d6e2e176db9
name: 'System contact details'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
key: 'dell.server.contact[sysContact]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
Name and contact information of the contact person for the node. If not provided, the value is a zero-length string.
inventory_link: CONTACT
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: a92165c0788f4073b773a3ccc00d8e33
name: 'SNMP walk Processor device tables'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]'
key: dell.server.cpu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.'
tags:
- tag: component
value: raw
- uuid: ed8c53e78cf1430895f819a1c79f1881
name: 'System description'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
key: 'dell.server.descr[sysDescr]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
- uuid: bfe85965ad6847b5913fc71ecd6b837d
name: 'SNMP walk Physical disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]'
key: dell.server.disk.physical.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.'
tags:
- tag: component
value: raw
- uuid: b5c22682042045c9972cd6779d31dabd
name: 'SNMP walk Virtual disk table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]'
key: dell.server.disk.virtual.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.'
tags:
- tag: component
value: raw
- uuid: bd6d36c7568f43e884654e8f7cbb4606
name: 'SNMP walk Cooling device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]'
key: dell.server.fan.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 0523d1c71ec648d3b7f72152bcdd3980
name: 'Firmware version'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the firmware version of a remote access card.
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: 06ad53c66cf241d285dd0e4a19b30105
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R660 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R660 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0'
name: 'Dell R660: Firmware has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Firmware version has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 3f474f2cc921445392d4153b4070c581
name: 'Hardware model name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]'
key: 'dell.server.hw.model[systemModelName]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the model name of the system.
inventory_link: MODEL
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: cd1220099942408eab14e854a9f556fe
name: 'Hardware serial number'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the service tag of the system.
inventory_link: SERIALNO_A
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: ab50b7de4a004c1bb8bae012e87a9fae
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R660 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R660 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0'
name: 'Dell R660: Device has been replaced'
event_name: 'Dell R660: Device has been replaced (new serial number received)'
priority: INFO
description: 'Device serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 86f3503ad4ce4210a9d367536075c78d
name: 'Uptime (hardware)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
trends: '0'
units: uptime
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the power-up time of the system in seconds.
tags:
- tag: component
value: system
- uuid: 94dacb3e9ce94c8abe29f5a1f3ed7414
name: 'System location'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
key: 'dell.server.location[sysLocation]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string.
inventory_link: LOCATION
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: aa5060ea16f54e348d0093600bc1369b
name: 'Memory, total size'
type: CALCULATED
key: dell.server.memory.size.total
units: B
params: 'sum(last_foreach(//dell.server.memory.size[*]))'
description: 'Total memory amount on the device.'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: memory
triggers:
- uuid: 9f583d671b3842798f0bd4d50d395c6e
expression: 'change(/DELL PowerEdge R660 by SNMP/dell.server.memory.size.total)>0'
name: 'Dell R660: Memory amount has changed'
opdata: 'Current value: {ITEM.LASTVALUE1}'
priority: AVERAGE
tags:
- tag: scope
value: availability
- uuid: 65592c126dd242e7b7fd9b574ed63281
name: 'SNMP walk Memory device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]'
key: dell.server.memory.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: feddc0222dab4e89a6caa661b67020a7
name: 'System name'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
key: 'dell.server.name[sysName]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string.
inventory_link: NAME
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
triggers:
- uuid: 59cb6156e1f84f0fb28beb51a8046da3
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R660 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R660 by SNMP/dell.server.name[sysName]))>0'
name: 'Dell R660: System name has changed'
event_name: 'Dell R660: System name has changed (new name: {ITEM.VALUE})'
priority: INFO
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 8d872ee881154af284dc295c0bb2a933
name: 'SNMP walk Network device table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]'
key: dell.server.net.if.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.'
tags:
- tag: component
value: raw
- uuid: 62a708d5e13b4d8fbf3d12b77164e2a0
name: 'Uptime (network)'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]'
key: 'dell.server.net.uptime[snmpEngineTime]'
trends: '0'
units: uptime
description: |
MIB: SNMP-FRAMEWORK-MIB
The number of seconds since the value of the snmpEngineBoots object last changed.
tags:
- tag: component
value: system
- uuid: 443fb640977a492f83cba1b7fb9454fe
name: 'System object ID'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
key: 'dell.server.objectid[sysObjectID]'
delay: 15m
value_type: CHAR
trends: '0'
description: |
MIB: SNMPv2-MIB
The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1).
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: system
- uuid: 5b1a6a7a7adb4c32b66ae22e698b174f
name: 'SNMP walk Power supply table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]'
key: dell.server.psu.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.'
tags:
- tag: component
value: raw
- uuid: 7e66e28304e24ddcaf79426b32070cb3
name: 'SNMP walk Temperature sensor table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]'
key: dell.server.sensor.temp.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 4acbcd1baf9e456a9d3e30d33282858a
name: 'Overall system health status'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]'
key: 'dell.server.status[globalSystemStatus]'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: 81762ad908ba492c897572f690606da3
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}'
name: 'Dell R660: System is in unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 04c60944973d402b9d3a0e96049c42ad
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
name: 'Dell R660: System status is in critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for errors.'
tags:
- tag: scope
value: availability
- uuid: 31fbf1a98d0646bd9082efc946e2a424
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}'
name: 'Dell R660: System status is in warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for warnings.'
dependencies:
- name: 'Dell R660: System status is in critical state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}'
tags:
- tag: scope
value: availability
- uuid: 069326e2f88d4ef9bbed30e94d08af5d
name: 'Operating system'
type: SNMP_AGENT
snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]'
key: 'dell.server.sw.os[systemOSName]'
delay: 1h
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the name of the operating system that the host is running.
inventory_link: OS
preprocessing:
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1d
tags:
- tag: component
value: system
triggers:
- uuid: d76ca22d7fd742efb84e04940fa9a846
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R660 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R660 by SNMP/dell.server.sw.os[systemOSName]))>0'
name: 'Dell R660: Operating system description has changed'
priority: INFO
description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 0918a2a56c6542629acc5cfa7f4c5255
name: 'SNMP walk System battery table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]'
key: dell.server.system.battery.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.'
tags:
- tag: component
value: raw
- uuid: 31ca246b873248439deb225f56d9c16b
name: 'SNMP walk Voltage probe table'
type: SNMP_AGENT
snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]'
key: dell.server.voltage.walk
history: '0'
value_type: TEXT
trends: '0'
description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.'
tags:
- tag: component
value: raw
- uuid: 9beb49cb322d48cfa061fc206b679a3e
name: 'SNMP traps (fallback)'
type: SNMP_TRAP
key: snmptrap.fallback
delay: '0'
value_type: LOG
trends: '0'
description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items'
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
tags:
- tag: component
value: network
- uuid: 3847459063014aafae40a59263c6cd21
name: 'SNMP agent availability'
type: INTERNAL
key: 'zabbix[host,snmp,available]'
description: |
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
Possible values:
0 - not available
1 - available
2 - unknown
valuemap:
name: zabbix.host.available
tags:
- tag: component
value: health
- tag: component
value: system
triggers:
- uuid: b7121bb9605148c299aa571ae0baaeac
expression: 'max(/DELL PowerEdge R660 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0'
name: 'Dell R660: No SNMP data collection'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
tags:
- tag: scope
value: availability
discovery_rules:
- uuid: ce45d29db5664f2a8057b59dbacb406c
name: 'Array controller discovery'
type: DEPENDENT
key: array.discovery
delay: '0'
description: 'Array controller discovery.'
item_prototypes:
- uuid: 0d3726a29096447ab2e6bc777266e24c
name: 'Controller [{#CNTLR_NAME}]: Model'
type: DEPENDENT
key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The controller's name as represented in Storage Management.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
- uuid: dccc777dbf40477d99824475e0899546
name: 'Controller [{#CNTLR_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the controller itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.array.controller.walk
tags:
- tag: component
value: diskarray
- tag: component
value: storage
trigger_prototypes:
- uuid: 922d9b5a81a24331bc127c537cce7844
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
name: 'Dell R660: Controller [{#CNTLR_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R660: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
- uuid: 651b100a1d6f4319af973417dcc846c8
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
name: 'Dell R660: Controller [{#CNTLR_NAME}]: Unrecoverable state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: aec00889d9d2419d8fd1e5b4cfc1095b
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
name: 'Dell R660: Controller [{#CNTLR_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R660: Controller [{#CNTLR_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
- name: 'Dell R660: Controller [{#CNTLR_NAME}]: Unrecoverable state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.array.controller.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38
- '0'
- '{#CNTLR_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: f24ac636401c47ddbbafb571ddbc9653
name: 'Battery discovery'
type: DEPENDENT
key: battery.discovery
delay: '0'
description: 'Battery discovery.'
item_prototypes:
- uuid: 641a35177d934e58afd3abf701dafcde
name: 'Battery [{#BATTERY_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Current state of battery.
Possible values:
1: The current state could not be determined.
2: The battery is operating normally.
3: The battery has failed and needs to be replaced.
4: The battery temperature is high or charge level is depleting.
5: The battery is missing or not detected.
6: The battery is undergoing the re-charge phase.
7: The battery voltage or charge level is below the threshold.
valuemap:
name: 'IDRAC-MIB-SMIv2::batteryState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.battery.walk
tags:
- tag: component
value: battery
- tag: component
value: diskarray
trigger_prototypes:
- uuid: 30752fbc757f47b4a44ce2e348b4be1c
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
name: 'Dell R660: Battery [{#BATTERY_NAME}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: c7c2724e188f4a568601d77f3f698212
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
name: 'Dell R660: Battery [{#BATTERY_NAME}]: Not in optimal state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R660: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
- name: 'Dell R660: Battery [{#BATTERY_NAME}]: Warning state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
tags:
- tag: scope
value: availability
- uuid: 4c5fca69653e4b02a0646b1f06947893
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
name: 'Dell R660: Battery [{#BATTERY_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R660: Battery [{#BATTERY_NAME}]: Critical state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#BATTERY_NUM}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1
- '0'
- '{#BATTERY_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 4eccdae6174d47b0808bba46de0bad6e
name: 'CPU status discovery'
type: DEPENDENT
key: cpu.discovery
delay: '0'
description: 'CPU status discovery.'
item_prototypes:
- uuid: 3e5f3afa1bd9466f80bc384df5e6adde
name: 'CPU [{#CPU_FQDD}]: State'
type: DEPENDENT
key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the reading of the processor device status probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: 67364b2e5a8a4a98a51846d23449510e
expression: 'bitand(last(/DELL PowerEdge R660 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0'
name: 'Dell R660: CPU [{#CPU_FQDD}]: Reading error'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU probe reading flag is not `processorPresent`.
tags:
- tag: scope
value: availability
- uuid: badfdf4bb0d54474b841335e6f31225b
name: 'CPU [{#CPU_FQDD}]: Status'
type: DEPENDENT
key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]'
delay: '0'
description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.cpu.walk
tags:
- tag: component
value: cpu
trigger_prototypes:
- uuid: 906617c75c7a4b9ebb8d5a8e0cfbb569
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3'
name: 'Dell R660: CPU [{#CPU_FQDD}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
CPU status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.cpu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#CPU_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 7c25c6c19ca44a47adc20f6abcafc765
name: 'Fan discovery'
type: DEPENDENT
key: fan.discovery
delay: '0'
filter:
conditions:
- macro: '{#TYPE}'
value: '3'
formulaid: A
description: 'Fan discovery.'
item_prototypes:
- uuid: aed80b32cd744e74a3dd6be26fb7264d
name: 'Fan [{#FAN_DESCR}]: Speed'
type: DEPENDENT
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
delay: '0'
units: rpm
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`.
When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device.
When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
- uuid: 77640960a1c14237af2a9241453b01bc
name: 'Fan [{#FAN_DESCR}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the cooling device.
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.fan.walk
tags:
- tag: component
value: fan
trigger_prototypes:
- uuid: 5b8056a1bef340baa9c265719b644d6d
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
name: 'Dell R660: Fan [{#FAN_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the fan unit.'
tags:
- tag: scope
value: availability
- uuid: 01d33d235a964bb59c409ee6f802077a
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R660: Fan [{#FAN_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the fan unit.'
dependencies:
- name: 'Dell R660: Fan [{#FAN_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 8572ad519aba4125bca793fa58c3ee7a
name: 'Dell R660: Fan [{#FAN_DESCR}]: Speed'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]'
master_item:
key: dell.server.fan.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.5
- '0'
- '{#FAN_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.8
- '0'
- '{#TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.700.12.1.7
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: a5af413068f44de78fbd8439b77c0e4a
name: 'Memory discovery'
type: DEPENDENT
key: memory.discovery
delay: '0'
description: 'Memory discovery.'
item_prototypes:
- uuid: bc5e6f0f7f854bddab8540eaff42469c
name: 'Memory [{#SNMPVALUE}]: Size'
type: DEPENDENT
key: 'dell.server.memory.size[{#SNMPVALUE}]'
delay: '0'
units: B
description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- type: MULTIPLIER
parameters:
- '1024'
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
- uuid: 51e7926cb91747ceb27e7e592b2567c8
name: 'Memory [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.memory.status[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the memory device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.memory.walk
tags:
- tag: component
value: memory
trigger_prototypes:
- uuid: 2d2d197d92d14a3b85e2a188bc76be2d
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3'
name: 'Dell R660: Memory [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Memory status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.memory.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: e9a4dcd3d9974b1ca2ee36ecfaba92d3
name: 'Network interface discovery'
type: DEPENDENT
key: net.if.discovery
delay: '0'
description: 'Discovery of network interfaces.'
item_prototypes:
- uuid: eb081fef5f304d199607a1ed5e4f0128
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status'
type: DEPENDENT
key: 'dell.server.net.if.link[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the connection status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: 9740ccc648034cbebc73167b6b6692f0
expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R660 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R660 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R660 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)'
recovery_mode: RECOVERY_EXPRESSION
recovery_expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0'
name: 'Dell R660: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
This trigger expression works as follows:
1. It can be triggered if the operations status is Down.
2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down.
3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.)
manual_close: 'YES'
tags:
- tag: scope
value: availability
- uuid: dae8d6b509ef4de7ac65f12f87b23b66
name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status'
type: DEPENDENT
key: 'dell.server.net.if.status[{#NIC_FQDD}]'
delay: '0'
description: 'This attribute defines the status of the network device.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.net.if.walk
tags:
- tag: component
value: network
trigger_prototypes:
- uuid: e54d6f6ae07a4e608e4e3a2a0e2cb248
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3'
name: 'Dell R660: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
Network interface status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.net.if.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#NIC_FQDD}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1
- '0'
- '{#NIC_MAC}'
- 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1
- '2'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 9b9014d6da704b1b825f879e162efdc8
name: 'Physical disk discovery'
type: DEPENDENT
key: physicaldisk.discovery
delay: '0'
description: 'Physical disk discovery.'
item_prototypes:
- uuid: 72c8a17c7d2a4613a83a729cd4ca64e6
name: 'Physical disk [{#DISK_NAME}]: Media type'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The media type of the physical disk. Possible Values:
1: The media type could not be determined.
2: Hard Disk Drive (HDD).
3: Solid State Drive (SSD).
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: d3d350bc81854a3da72ae694d57062c5
name: 'Physical disk [{#DISK_NAME}]: Model name'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The model number of the physical disk.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 83f108ffd84444e2b7bbc9e0b103c02b
name: 'Physical disk [{#DISK_NAME}]: Serial number'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]'
delay: '0'
value_type: CHAR
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The physical disk's unique identification number from the manufacturer.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 387ab14c93784076b776a8dd6eac7cd5
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0'
name: 'Dell R660: Physical disk [{#DISK_NAME}] has been replaced'
event_name: 'Dell R660: [{#DISK_NAME}] has been replaced (new serial number received)'
priority: INFO
description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
- uuid: 21601518669d483daea2e5950c449d6e
name: 'Physical disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the physical disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
- uuid: 0e4f4c25cfb144cf8728ece8ddcf6b90
name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
Indicates whether the physical disk has received a predictive failure alert.
valuemap:
name: 'IDRAC-MIB-SMIv2::BooleanType'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 48741d6a36484dfba7edc893d1f06f68
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}'
name: 'Dell R660: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Disk probably requires replacement.'
dependencies:
- name: 'Dell R660: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
- uuid: f58be233639845038d8dad2452f6003a
name: 'Physical disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The status of the physical disk itself without the propagation of any contained component status.
Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
valuemap:
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.physical.walk
tags:
- tag: component
value: physicaldisk
- tag: component
value: storage
trigger_prototypes:
- uuid: 090de34ecef14ebc8a6383a50b4255ad
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
name: 'Dell R660: Physical disk [{#DISK_NAME}]: Failed state'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check physical disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: 11dffa72d07e43c5a63f624e126b38ac
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
name: 'Dell R660: Physical disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check physical disk for warnings or errors.'
dependencies:
- name: 'Dell R660: Physical disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R660 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
tags:
- tag: scope
value: availability
graph_prototypes:
- uuid: 7041ed04c6f14703b36b52aa68b49b2e
name: 'Dell R660: Physical disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.physical.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: a303f72921fe4aaf87a58b53409d3e93
name: 'PSU discovery'
type: DEPENDENT
key: psu.discovery
delay: '0'
description: 'PSU discovery.'
item_prototypes:
- uuid: ded0373d94e4467c9495cf94a7d96628
name: 'Power supply [{#PSU_DESCR}]: State'
type: DEPENDENT
key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]'
delay: '0'
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the status of the power supply.
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.psu.walk
tags:
- tag: component
value: psu
trigger_prototypes:
- uuid: 14698cb8183340818414f36d05abb428
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
name: 'Dell R660: Power supply [{#PSU_DESCR}]: Critical state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the power supply unit for errors.'
tags:
- tag: scope
value: availability
- uuid: 20c0b3af5ad24a1bbb29c759452f6620
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
name: 'Dell R660: Power supply [{#PSU_DESCR}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the power supply unit for errors.'
dependencies:
- name: 'Dell R660: Power supply [{#PSU_DESCR}]: Critical state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
tags:
- tag: scope
value: availability
master_item:
key: dell.server.psu.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.5
- '0'
- '{#PSU_DESCR}'
- 1.3.6.1.4.1.674.10892.5.4.600.12.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: b0440590b39848758e67dd614844b1bd
name: 'System battery discovery'
type: DEPENDENT
key: system.battery.discovery
delay: '0'
description: 'System battery discovery.'
item_prototypes:
- uuid: 73e8b6ae099a4109b03417d2c9b849cc
name: 'System battery [{#SNMPVALUE}]: Status'
type: DEPENDENT
key: 'dell.server.system.battery[{#SNMPVALUE}]'
delay: '0'
description: 'This attribute defines the status of the battery.'
valuemap:
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.system.battery.walk
tags:
- tag: component
value: battery
trigger_prototypes:
- uuid: 272f79a4c334434489c026133e7faea6
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3'
name: 'Dell R660: System battery [{#SNMPVALUE}]: Status is not OK'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: |
MIB: IDRAC-MIB-SMIv2
System battery status is not OK.
tags:
- tag: scope
value: availability
master_item:
key: dell.server.system.battery.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 4dcc455d35774521b8b9c37cf0f8ddb3
name: 'Temperature discovery'
type: DEPENDENT
key: temp.discovery
delay: '0'
description: 'Temperature sensor discovery.'
item_prototypes:
- uuid: e6f3ff1e7a4d460eb436b5798ea73762
name: 'Probe [{#SENSOR_LOCALE}]: Status'
type: DEPENDENT
key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
trends: '0'
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the probe status of the temperature probe.
Possible values:
other(1), -- probe status is not one of the following:
unknown(2), -- probe status is unknown (not known or monitored)
ok(3), -- probe is reporting a value within the thresholds
nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold
criticalUpper(5), -- probe has crossed the upper critical threshold
nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold
nonCriticalLower(7), -- probe has crossed the lower noncritical threshold
criticalLower(8), -- probe has crossed the lower critical threshold
nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold
failed(10) -- probe is not functional
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
trigger_prototypes:
- uuid: ad72d86ab2ff47e081d56d755c9f38cf
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
name: 'Dell R660: Probe [{#SENSOR_LOCALE}]: Critical status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device for faults.'
tags:
- tag: scope
value: availability
- uuid: 2bedce1701084c30a4e443f6a5681bde
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
name: 'Dell R660: Probe [{#SENSOR_LOCALE}]: Not in optimal status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: INFO
description: 'Please check the device for faults.'
manual_close: 'YES'
dependencies:
- name: 'Dell R660: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
- name: 'Dell R660: Probe [{#SENSOR_LOCALE}]: Warning status'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
tags:
- tag: scope
value: notice
- uuid: abcff76920ca4f64b58f7bdcde618181
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
name: 'Dell R660: Probe [{#SENSOR_LOCALE}]: Warning status'
opdata: 'Current status: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the device for faults.'
dependencies:
- name: 'Dell R660: Probe [{#SENSOR_LOCALE}]: Critical status'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R660 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
tags:
- tag: scope
value: availability
- uuid: 3710a01c29e84b55ae9040c1f69de95a
name: 'Probe [{#SENSOR_LOCALE}]: Value'
type: DEPENDENT
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
delay: '0'
value_type: FLOAT
units: °C
description: |
MIB: IDRAC-MIB-SMIv2
This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`.
When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade.
When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.1'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.sensor.temp.walk
tags:
- tag: component
value: temperature
graph_prototypes:
- uuid: e6fa96c07eed45f4be0c3c63b3782804
name: 'Dell R660: Probe [{#SENSOR_LOCALE}]: Value'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]'
master_item:
key: dell.server.sensor.temp.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
- '0'
- '{#SENSOR_LOCALE}'
- 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 59ebee32aa89490a9a6ac84c8706fc04
name: 'Virtual disk discovery'
type: DEPENDENT
key: virtualdisk.discovery
delay: '0'
description: 'Virtual disk discovery.'
item_prototypes:
- uuid: 43e9d39607614eae80550101d029aa6f
name: 'Virtual disk [{#DISK_NAME}]: Layout type'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The virtual disk's RAID type.
Possible values:
1: Not one of the following
2: RAID-0
3: RAID-1
4: RAID-5
5: RAID-6
6: RAID-10
7: RAID-50
8: RAID-60
9: Concatenated RAID 1
10: Concatenated RAID 5
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 94b642e109cf4b509e8e778d4c465cdd
name: 'Virtual disk [{#DISK_NAME}]: Read policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The read policy used by the controller for read operations on this virtual disk.
Possible values:
1: No Read Ahead.
2: Read Ahead.
3: Adaptive Read Ahead.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 485837b0fe5a40699210fefaba81ccec
name: 'Virtual disk [{#DISK_NAME}]: Size'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
delay: '0'
trends: '0'
units: B
description: |
MIB: IDRAC-MIB-SMIv2
The size of the virtual disk in megabytes.
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '1048576'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 0a1ec895744b4cfc86410de425f82fa3
name: 'Virtual disk [{#DISK_NAME}]: Operational state'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The state of the virtual disk when there are progressive operations ongoing.
Possible values:
1: There is no active operation running.
2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.
3: A Consistency Check (CC) is being performed on the virtual disk.
4: The virtual disk is being initialized.
5: BackGround Initialization (BGI) is being performed on the virtual disk.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 3m
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
- uuid: 1751727ae3a74e719d5aa66b4fe7254f
name: 'Virtual disk [{#DISK_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The current state of this virtual disk (which includes any member physical disks.)
Possible states:
1: The current state could not be determined.
2: The virtual disk is operating normally or optimally.
3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost.
4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.
The data on the virtual disk might no longer be fault tolerant.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
trigger_prototypes:
- uuid: 29cab0ba7b674b298435e7babd4d13d4
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
name: 'Dell R660: Virtual disk [{#DISK_NAME}]: Failed state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: HIGH
description: 'Please check the virtual disk for warnings or errors.'
tags:
- tag: scope
value: availability
- uuid: aeeb4eac4abc4b6bb92de1a22e9840eb
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
name: 'Dell R660: Virtual disk [{#DISK_NAME}]: Warning state'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: WARNING
description: 'Please check the virtual disk for warnings or errors.'
dependencies:
- name: 'Dell R660: Virtual disk [{#DISK_NAME}]: Failed state'
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
tags:
- tag: scope
value: availability
- uuid: c80bd3fd5d1249a7b808512a3c62d28b
name: 'Virtual disk [{#DISK_NAME}]: Write policy'
type: DEPENDENT
key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]'
delay: '0'
description: |
MIB: IDRAC-MIB-SMIv2
The write policy used by the controller for write operations on this virtual disk.
Possible values:
1: Write Through.
2: Write Back.
3: Force Write Back.
valuemap:
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}'
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 1h
master_item:
key: dell.server.disk.virtual.walk
tags:
- tag: component
value: storage
- tag: component
value: virtualdisk
graph_prototypes:
- uuid: 7128dd52533e43c582946dc346c6882b
name: 'Dell R660: Virtual disk [{#DISK_NAME}]: Size'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]'
master_item:
key: dell.server.disk.virtual.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#SNMPVALUE}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1
- '0'
- '{#DISK_NAME}'
- 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2
- '0'
error_handler: DISCARD_VALUE
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
- uuid: 85322325c90646d29fe6db928f28fa03
name: 'Voltage probe discovery'
type: DEPENDENT
key: voltage.discovery
delay: '0'
filter:
evaltype: AND
conditions:
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
formulaid: A
- macro: '{#VPROBE_NAME}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: B
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
formulaid: C
- macro: '{#VPROBE_TYPE}'
value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
operator: NOT_MATCHES_REGEX
formulaid: D
description: 'Voltage probe discovery.'
item_prototypes:
- uuid: 61c9b167810f48ccb092b9a558159191
name: 'Voltage probe [{#VPROBE_NAME}]: Status'
type: DEPENDENT
key: 'dell.server.voltage.status[{#VPROBE_NAME}]'
delay: '0'
description: 'This attribute defines the status of the voltage probe.'
valuemap:
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}'
- '0'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
trigger_prototypes:
- uuid: c68730ac9acf427b9c03c3d3a68197d5
expression: 'last(/DELL PowerEdge R660 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3'
name: 'Dell R660: Voltage probe [{#VPROBE_NAME}]: Status is not OK'
opdata: 'Current state: {ITEM.LASTVALUE1}'
priority: AVERAGE
description: 'Please check the device''s voltage.'
tags:
- tag: scope
value: availability
- uuid: 05894e7311ee4a5ab0108e4135416ebf
name: 'Voltage probe [{#VPROBE_NAME}]: Voltage'
type: DEPENDENT
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
delay: '0'
value_type: FLOAT
units: V
description: 'This attribute defines the reading for a voltage probe.'
preprocessing:
- type: SNMP_WALK_VALUE
parameters:
- '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}'
- '0'
- type: MULTIPLIER
parameters:
- '0.001'
master_item:
key: dell.server.voltage.walk
tags:
- tag: component
value: voltage
graph_prototypes:
- uuid: 2c0c884b124b4abc8869cdac905df0ef
name: 'Dell R660: Voltage probe [{#VPROBE_NAME}]: Voltage'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.voltage.value[{#VPROBE_NAME}]'
master_item:
key: dell.server.voltage.walk
preprocessing:
- type: SNMP_WALK_TO_JSON
parameters:
- '{#VPROBE_NAME}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1
- '0'
- '{#VPROBE_TYPE}'
- 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1
- '0'
- type: DISCARD_UNCHANGED_HEARTBEAT
parameters:
- 6h
tags:
- tag: class
value: hardware
- tag: target
value: dell
- tag: target
value: 'dell poweredge'
macros:
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}'
value: '^.*Voltage.*$'
description: 'Sets the regex string of voltage probe names to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe names to ignore in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}'
value: 18|16
description: 'Sets the regex string of voltage probe types to allow in discovery.'
- macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}'
value: CHANGE_IF_NEEDED
description: 'Sets the regex string of voltage probe types to ignore in discovery.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}'
value: '3'
description: 'The critical status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}'
value: '2'
description: 'The OK status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array cache battery for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}'
value: '5'
description: 'The critical status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}'
value: '6'
description: 'The disaster status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}'
value: '4'
description: 'The warning status of the disk array for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}'
value: '1'
description: 'The critical S.M.A.R.T status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}'
value: '5'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}'
value: '6'
description: 'The critical status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning status of the disk for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}'
value: '10'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning value of the FAN sensor for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}'
value: '5'
description: 'The critical status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}'
value: '6'
description: 'The disaster status of health for the trigger expression.'
- macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}'
value: '4'
description: 'The warning status of health for the trigger expression.'
- macro: '{$DELL.SNMP.IFCONTROL}'
value: '1'
description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}'
value: '5'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}'
value: '6'
description: 'The critical value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}'
value: '4'
description: 'The warning value of the PSU sensor for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}'
value: '8'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}'
value: '5'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}'
value: '9'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}'
value: '6'
description: 'The critical status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}'
value: '3'
description: 'The OK status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}'
value: '7'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}'
value: '4'
description: 'The warning status of the temperature probe for the trigger expression.'
- macro: '{$DELL.SNMP.TIMEOUT}'
value: 5m
description: 'The time interval for the SNMP agent availability trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}'
value: '3'
description: 'The critical status of the virtual disk for the trigger expression.'
- macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}'
value: '4'
description: 'The warning status of the virtual disk for the trigger expression.'
dashboards:
- uuid: 1bbf4fc1f4cf4581835b8272b042a144
name: Overview
pages:
- name: Overview
display_period: '30'
widgets:
- type: item
name: 'System health'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'System Health'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.status[globalSystemStatus]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'Serial number'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'Serial number'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.hw.serialnumber[systemServiceTag]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: 'HW model'
x: '36'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: 'HW model'
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.hw.model[systemModelName]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- type: item
name: Firmware
x: '36'
'y': '4'
width: '36'
height: '4'
hide_header: 'YES'
fields:
- type: STRING
name: bg_color
value: 2196F3
- type: STRING
name: description
value: Firmware
- type: STRING
name: desc_color
value: FFFFFF
- type: INTEGER
name: desc_v_pos
value: '0'
- type: ITEM
name: itemid.0
value:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.hw.firmware[racFirmwareVersion]'
- type: INTEGER
name: show.0
value: '2'
- type: INTEGER
name: show.1
value: '1'
- type: STRING
name: value_color
value: FFFFFF
- type: INTEGER
name: value_size
value: '35'
- name: Discoveries
display_period: '30'
widgets:
- type: honeycomb
name: 'Interface link'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'NIC*Link status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAA
- type: STRING
name: thresholds.0.color
value: 069C56
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: FF681E
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: 'Temperature sensors'
'y': '4'
width: '72'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Probe*Value'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAB
- type: INTEGER
name: secondary_label_decimal_places
value: '0'
- type: honeycomb
name: 'Physical disks'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Physical disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size
value: '15'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAC
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
- type: honeycomb
name: 'Power supplies'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Voltage probe*Voltage'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAE
- type: honeycomb
name: 'Virtual disks'
x: '36'
'y': '8'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Virtual disk*: Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAD
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '1'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '2'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '3'
- type: honeycomb
name: Fans
x: '36'
'y': '12'
width: '36'
height: '4'
fields:
- type: STRING
name: items.0
value: 'Fan*Status'
- type: STRING
name: primary_label
value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}'
- type: INTEGER
name: primary_label_size_type
value: '1'
- type: STRING
name: reference
value: AAAAF
- type: STRING
name: thresholds.0.color
value: FF980E
- type: STRING
name: thresholds.0.threshold
value: '0'
- type: STRING
name: thresholds.1.color
value: 069C56
- type: STRING
name: thresholds.1.threshold
value: '3'
- type: STRING
name: thresholds.2.color
value: D3212C
- type: STRING
name: thresholds.2.threshold
value: '4'
valuemaps:
- uuid: ffad2b2a57364726ba31cfc89f363e2b
name: 'IDRAC-MIB-SMIv2::batteryState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Ready
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- value: '5'
newvalue: Missing
- value: '6'
newvalue: Charging
- value: '7'
newvalue: 'Below threshold'
- uuid: 053a4a529ddf4bc7b1971958e4dce5c9
name: 'IDRAC-MIB-SMIv2::BooleanType'
mappings:
- value: '0'
newvalue: ok
- value: '1'
newvalue: failed
- uuid: 2216bf2485f548be90060048eec6547d
name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum'
mappings:
- value: '0'
newvalue: unknown
- value: '1'
newvalue: connected
- value: '2'
newvalue: disconnected
- value: '3'
newvalue: driverBad
- value: '4'
newvalue: driverDisabled
- value: '10'
newvalue: hardwareInitalizing
- value: '11'
newvalue: hardwareResetting
- value: '12'
newvalue: hardwareClosing
- value: '13'
newvalue: hardwareNotReady
- uuid: 58480240826e49b09bf73f682f252148
name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: e44bc856e8d449f9a288b614b7d6a143
name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCritical
- value: '5'
newvalue: critical
- value: '6'
newvalue: nonRecoverable
- uuid: e17dbbe344994170afa47b3d76b393f8
name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: HDD
- value: '3'
newvalue: SSD
- uuid: c9543b611d434fba99d4be3614813419
name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags'
mappings:
- value: '1'
newvalue: internalError
- value: '2'
newvalue: thermalTrip
- value: '32'
newvalue: configurationError
- value: '128'
newvalue: processorPresent
- value: '256'
newvalue: processorDisabled
- value: '512'
newvalue: terminatorPresent
- value: '1024'
newvalue: processorThrottled
- uuid: d2f5ad57814e4c3ab8f1e7b1fa076557
name: 'IDRAC-MIB-SMIv2::StatusProbeEnum'
mappings:
- value: '1'
newvalue: other
- value: '2'
newvalue: unknown
- value: '3'
newvalue: ok
- value: '4'
newvalue: nonCriticalUpper
- value: '5'
newvalue: criticalUpper
- value: '6'
newvalue: nonRecoverableUpper
- value: '7'
newvalue: nonCriticalLower
- value: '8'
newvalue: criticalLower
- value: '9'
newvalue: nonRecoverableLower
- value: '10'
newvalue: failed
- uuid: 70851c009b4d4f0484f3bb955558c1db
name: 'IDRAC-MIB-SMIv2::virtualDiskLayout'
mappings:
- value: '1'
newvalue: Other
- value: '2'
newvalue: RAID-0
- value: '3'
newvalue: RAID-1
- value: '4'
newvalue: RAID-5
- value: '5'
newvalue: RAID-6
- value: '6'
newvalue: RAID-10
- value: '7'
newvalue: RAID-50
- value: '8'
newvalue: RAID-60
- value: '9'
newvalue: 'Concatenated RAID 1'
- value: '10'
newvalue: 'Concatenated RAID 5'
- uuid: 160204c8609542038d31357ce58424df
name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState'
mappings:
- value: '1'
newvalue: 'Not applicable'
- value: '2'
newvalue: Reconstructing
- value: '3'
newvalue: Resynching
- value: '4'
newvalue: Initializing
- value: '5'
newvalue: 'Background init'
- uuid: c1686f5a938f4dac977d55517687358e
name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy'
mappings:
- value: '1'
newvalue: 'No Read Ahead'
- value: '2'
newvalue: 'Read Ahead'
- value: '3'
newvalue: 'Adaptive Read Ahead'
- uuid: 1c3e3bcf7ff14f59ac24f9d62f6671af
name: 'IDRAC-MIB-SMIv2::virtualDiskState'
mappings:
- value: '1'
newvalue: Unknown
- value: '2'
newvalue: Online
- value: '3'
newvalue: Failed
- value: '4'
newvalue: Degraded
- uuid: 0a940bdd7900425b941e11e486e70c8a
name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy'
mappings:
- value: '1'
newvalue: 'Write Through'
- value: '2'
newvalue: 'Write Back'
- value: '3'
newvalue: 'Force Write Back'
- uuid: 20182c95fb0e494a826a7ae3f932127b
name: zabbix.host.available
mappings:
- value: '0'
newvalue: 'not available'
- value: '1'
newvalue: available
- value: '2'
newvalue: unknown
triggers:
- uuid: 0c72f52ac52c46adab21c577c27381b1
expression: '(last(/DELL PowerEdge R660 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R660 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R660 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R660 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)'
name: 'Dell R660: Host has been restarted'
event_name: 'Dell R660: {HOST.NAME} has been restarted (uptime < 10m)'
priority: WARNING
description: 'Uptime is less than 10 minutes.'
manual_close: 'YES'
tags:
- tag: scope
value: notice
graphs:
- uuid: 92c35ca847fb44cbae6542f1b11e41da
name: 'Dell R660: Uptime'
graph_items:
- color: 199C0D
item:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.hw.uptime[systemPowerUpTime]'
- sortorder: '1'
color: F63100
item:
host: 'DELL PowerEdge R660 by SNMP'
key: 'dell.server.net.uptime[snmpEngineTime]'