zabbix_export: version: '7.0' template_groups: - uuid: e960332b3f6c46a1956486d4f3f99fce name: 'Templates/Server hardware' templates: - uuid: 9fde0e1c36f8453da72f97535d4e74ca template: 'DELL PowerEdge R740 by SNMP' name: 'DELL PowerEdge R740 by SNMP' description: | Template for DELL PowerEdge R740 servers with iDRAC version 7 and later. MIBs used: HOST-RESOURCES-MIB IDRAC-MIB-SMIv2 SNMPv2-MIB You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/426752-discussion-thread-for-official-zabbix-dell-templates Generated by official Zabbix template tool "Templator" vendor: name: Zabbix version: 7.0-5 groups: - name: 'Templates/Server hardware' items: - uuid: f956a1ccd0f14b1b88c1d98e6850cd7b name: 'SNMP walk RAID controllers table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79,1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2]' key: dell.server.array.controller.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::controllerTable`.' tags: - tag: component value: raw - uuid: ab2744fa308e4a51be4617b7ded321a0 name: 'SNMP walk Battery table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4,1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21]' key: dell.server.battery.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of RAID Controllers Table `IDRAC-MIB-SMIv2::batteryTable`.' tags: - tag: component value: raw - uuid: 3e3a215ef84946619beb4cc769ef7573 name: 'BIOS version' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1]' key: dell.server.bios.version value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the version name of the system BIOS. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: bb8eb9194d964824a3c62f0cdd777520 name: 'System contact details' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.4.0]' key: 'dell.server.contact[sysContact]' delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB Name and contact information of the contact person for the node. If not provided, the value is a zero-length string. inventory_link: CONTACT preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: 0612a426ef21465085614e790fa4e886 name: 'SNMP walk Processor device tables' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.30.1.26,1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.1]' key: dell.server.cpu.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Processor Device Status Table `IDRAC-MIB-SMIv2::processorDeviceTable` and `IDRAC-MIB-SMIv2::processorDeviceStatusTable`.' tags: - tag: component value: raw - uuid: d16c384f99a94a22a0a24a01070d95a2 name: 'System description' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.1.0]' key: 'dell.server.descr[sysDescr]' delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating system, and networking software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: d3ab597f3148403f801b32f9faa71e34 name: 'SNMP walk Physical disk table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35,1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11]' key: dell.server.disk.physical.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Physical Disk Table `IDRAC-MIB-SMIv2::physicalDiskTable`.' tags: - tag: component value: raw - uuid: 0f11e52e20ca4dd2a0723ba0a86eda20 name: 'SNMP walk Virtual disk table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6,1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4]' key: dell.server.disk.virtual.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Virtual Disk Table `IDRAC-MIB-SMIv2::virtualDiskTable`.' tags: - tag: component value: raw - uuid: f5b95355db804ca2a1f050b45174faa5 name: 'SNMP walk Cooling device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.12.1.5,1.3.6.1.4.1.674.10892.5.4.700.12.1.8,1.3.6.1.4.1.674.10892.5.4.700.12.1.7,1.3.6.1.4.1.674.10892.5.4.700.12.1.6]' key: dell.server.fan.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Cooling Device Table `IDRAC-MIB-SMIv2::coolingDeviceTable`.' tags: - tag: component value: raw - uuid: ab2437a52da14bd28e54b781d9f1034d name: 'Firmware version' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.1.8.0]' key: 'dell.server.hw.firmware[racFirmwareVersion]' delay: 1h value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the firmware version of a remote access card. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: b77eee80359e4fac87d36257d8adc38a expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#1)<>last(/DELL PowerEdge R740 by SNMP/dell.server.hw.firmware[racFirmwareVersion],#2) and length(last(/DELL PowerEdge R740 by SNMP/dell.server.hw.firmware[racFirmwareVersion]))>0' name: 'Dell R740: Firmware has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: INFO description: 'Firmware version has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: da32b347cedf4f7a906b6a819e08cf16 name: 'Hardware model name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.12.0]' key: 'dell.server.hw.model[systemModelName]' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the model name of the system. inventory_link: MODEL preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: c18ca70147524b0b95dd239c81495637 name: 'Hardware serial number' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.2.0]' key: 'dell.server.hw.serialnumber[systemServiceTag]' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the service tag of the system. inventory_link: SERIALNO_A preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: 0610dd019a64431f954a41b58e34e0a1 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#1)<>last(/DELL PowerEdge R740 by SNMP/dell.server.hw.serialnumber[systemServiceTag],#2) and length(last(/DELL PowerEdge R740 by SNMP/dell.server.hw.serialnumber[systemServiceTag]))>0' name: 'Dell R740: Device has been replaced' event_name: 'Dell R740: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 330f4c339c95443fb87640d2d807e4d9 name: 'Uptime (hardware)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.5.0]' key: 'dell.server.hw.uptime[systemPowerUpTime]' trends: '0' units: uptime description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the power-up time of the system in seconds. tags: - tag: component value: system - uuid: 3a354c53006b44f3993c962c60028c33 name: 'System location' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.6.0]' key: 'dell.server.location[sysLocation]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The physical location of this node (e.g., 'telephone closet, 3rd floor'). If the location is unknown, the value is a zero-length string. inventory_link: LOCATION preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: 78d9d2f87bd743e4b55cc8e9ca64fd1e name: 'Memory, total size' type: CALCULATED key: dell.server.memory.size.total units: B params: 'sum(last_foreach(//dell.server.memory.size[*]))' description: 'Total memory amount on the device.' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: memory triggers: - uuid: 1b12170aa1dd4b278e887bd20d3a7f00 expression: 'change(/DELL PowerEdge R740 by SNMP/dell.server.memory.size.total)>0' name: 'Dell R740: Memory amount has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: AVERAGE tags: - tag: scope value: availability - uuid: 68deb350a71341e19dc6740d327af700 name: 'SNMP walk Memory device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1,1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1]' key: dell.server.memory.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Memory Device Table `IDRAC-MIB-SMIv2::memoryDeviceTable`.' tags: - tag: component value: raw - uuid: d6962f725c4547ebb939503dae9f24dd name: 'System name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.5.0]' key: 'dell.server.name[sysName]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is a zero-length string. inventory_link: NAME preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system triggers: - uuid: bc5e7a8b73b6425d9ba59c7c1bb44276 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.name[sysName],#1)<>last(/DELL PowerEdge R740 by SNMP/dell.server.name[sysName],#2) and length(last(/DELL PowerEdge R740 by SNMP/dell.server.name[sysName]))>0' name: 'Dell R740: System name has changed' event_name: 'Dell R740: System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'The name of the system has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 25dc5f538e5b4b108e9fcc6866cbbdf4 name: 'SNMP walk Network device table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1,1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1, 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1]' key: dell.server.net.if.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Network Device Table `IDRAC-MIB-SMIv2::networkDeviceTable`.' tags: - tag: component value: raw - uuid: c0953b2a7dc24b03b098b6ae66af77df name: 'Uptime (network)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.6.3.10.2.1.3.0]' key: 'dell.server.net.uptime[snmpEngineTime]' trends: '0' units: uptime description: | MIB: SNMP-FRAMEWORK-MIB The number of seconds since the value of the snmpEngineBoots object last changed. tags: - tag: component value: system - uuid: af019e901b1948c68888b90a703b9718 name: 'System object ID' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.2.0]' key: 'dell.server.objectid[sysObjectID]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the entity as part of the vendor's SMI enterprises subtree with the prefix 1.3.6.1.4.1 (e.g., a vendor with the identifier 1.3.6.1.4.1.4242 might assign a system object with the OID 1.3.6.1.4.1.4242.1.1). preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: system - uuid: a9c00a61d4284fe581d097739dcc3f86 name: 'SNMP walk Power supply table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.12.1.5,1.3.6.1.4.1.674.10892.5.4.600.12.1.8]' key: dell.server.psu.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Power Supply Table `IDRAC-MIB-SMIv2::powerSupplyTable`.' tags: - tag: component value: raw - uuid: 1acb2a2c55b349278c46e2d4f12b446b name: 'SNMP walk Temperature sensor table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.700.20.1.1,1.3.6.1.4.1.674.10892.5.4.700.20.1.8,1.3.6.1.4.1.674.10892.5.4.700.20.1.6,1.3.6.1.4.1.674.10892.5.4.700.20.1.5]' key: dell.server.sensor.temp.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Temperature Probe Table `IDRAC-MIB-SMIv2::temperatureProbeTable`.' tags: - tag: component value: raw - uuid: 2e84d73b00bf45c7a143e52bb278c5f1 name: 'Overall system health status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.2.1.0]' key: 'dell.server.status[globalSystemStatus]' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the overall rollup status of all the components in the system monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: health - tag: component value: system triggers: - uuid: 85a8a9c18082436d8fedeebfca0b7173 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.DISASTER}' name: 'Dell R740: System is in unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: f0cf8ea9011443b5bdb6cc92af5e63fb expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}' name: 'Dell R740: System status is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for errors.' tags: - tag: scope value: availability - uuid: 9fe1bfd6ae724365b5ce13edf0dc8823 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.WARN}' name: 'Dell R740: System status is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for warnings.' dependencies: - name: 'Dell R740: System status is in critical state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.status[globalSystemStatus])={$DELL.SNMP.HEALTH.STATUS.CRIT}' tags: - tag: scope value: availability - uuid: 91ef2785cfa944f286c267ab351d8f33 name: 'Operating system' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.674.10892.5.1.3.6.0]' key: 'dell.server.sw.os[systemOSName]' delay: 1h value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the name of the operating system that the host is running. inventory_link: OS preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 6dc4593b42f341799eac23ee792f765d expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sw.os[systemOSName],#1)<>last(/DELL PowerEdge R740 by SNMP/dell.server.sw.os[systemOSName],#2) and length(last(/DELL PowerEdge R740 by SNMP/dell.server.sw.os[systemOSName]))>0' name: 'Dell R740: Operating system description has changed' priority: INFO description: 'Operating system description has changed. Possibly, the system has been updated or replaced. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: e3e8a5715afe4109b5c157ccf33e8a85 name: 'SNMP walk System battery table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1,1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1]' key: dell.server.system.battery.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of System Battery Table `IDRAC-MIB-SMIv2::systemBatteryTable`.' tags: - tag: component value: raw - uuid: 71732127775d4675b73bea0d7b941b60 name: 'SNMP walk Voltage probe table' type: SNMP_AGENT snmp_oid: 'walk[1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1,1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1]' key: dell.server.voltage.walk history: '0' value_type: TEXT trends: '0' description: 'Scanning of Voltage Probe Table `IDRAC-MIB-SMIv2::voltageProbeTable`.' tags: - tag: component value: raw - uuid: 1a90d82b418a416b8aa4575fc6b1e35d name: 'SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback delay: '0' value_type: LOG trends: '0' description: 'The item is used to collect all SNMP traps unmatched by other `snmptrap` items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: component value: network - uuid: f249e299f7c944abbbb8fc824f36b664 name: 'SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' description: | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown valuemap: name: zabbix.host.available tags: - tag: component value: health - tag: component value: system triggers: - uuid: c743348ae566468d93ac23508511443d expression: 'max(/DELL PowerEdge R740 by SNMP/zabbix[host,snmp,available],{$DELL.SNMP.TIMEOUT})=0' name: 'Dell R740: No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' tags: - tag: scope value: availability discovery_rules: - uuid: dccb5d8d2a7747709446943ad676adb3 name: 'Array controller discovery' type: DEPENDENT key: array.discovery delay: '0' description: 'Array controller discovery.' item_prototypes: - uuid: c4661a1ee2804c51a232f4fb8fca715d name: 'Controller [{#CNTLR_NAME}]: Model' type: DEPENDENT key: 'dell.server.hw.diskarray.model[controllerName.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The controller's name as represented in Storage Management. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.array.controller.walk tags: - tag: component value: diskarray - tag: component value: storage - uuid: 77c20c4aef9143dd882bbc4baba53d9a name: 'Controller [{#CNTLR_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.array.controller.walk tags: - tag: component value: diskarray - tag: component value: storage trigger_prototypes: - uuid: ca19f66711ad4cc8acadcd6787102a56 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' name: 'Dell R740: Controller [{#CNTLR_NAME}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: Controller [{#CNTLR_NAME}]: Unrecoverable state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability - uuid: 9b0c2970eb304b4f8495a6caa6505ed9 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' name: 'Dell R740: Controller [{#CNTLR_NAME}]: Unrecoverable state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 3a36696db31040c6bc10d9180067dc52 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.WARN}' name: 'Dell R740: Controller [{#CNTLR_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: Controller [{#CNTLR_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' - name: 'Dell R740: Controller [{#CNTLR_NAME}]: Unrecoverable state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' tags: - tag: scope value: availability master_item: key: dell.server.array.controller.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38 - '0' - '{#CNTLR_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 5ca20f2fd3c34b03bc3e0e926a250a12 name: 'Battery discovery' type: DEPENDENT key: battery.discovery delay: '0' description: 'Battery discovery.' item_prototypes: - uuid: 615fa3adb8664879ba577f6b334eefb8 name: 'Battery [{#BATTERY_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.battery.status[batteryState.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 Current state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and needs to be replaced. 4: The battery temperature is high or charge level is depleting. 5: The battery is missing or not detected. 6: The battery is undergoing the re-charge phase. 7: The battery voltage or charge level is below the threshold. valuemap: name: 'IDRAC-MIB-SMIv2::batteryState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.battery.walk tags: - tag: component value: battery - tag: component value: diskarray trigger_prototypes: - uuid: 603c5383bea74ce3948294b01158b81c expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' name: 'Dell R740: Battery [{#BATTERY_NAME}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 8107d20d4dee4f18b9a3985f02471a00 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])<>{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' name: 'Dell R740: Battery [{#BATTERY_NAME}]: Not in optimal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: Battery [{#BATTERY_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' - name: 'Dell R740: Battery [{#BATTERY_NAME}]: Warning state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' tags: - tag: scope value: availability - uuid: 79b0622881594658bfb7c8b7792d1053 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' name: 'Dell R740: Battery [{#BATTERY_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: Battery [{#BATTERY_NAME}]: Critical state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.battery.status[batteryState.{#SNMPINDEX}])={$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' tags: - tag: scope value: availability master_item: key: dell.server.battery.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#BATTERY_NUM}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 - '0' - '{#BATTERY_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 17db79dcd7c04d798e7a8b04614a7ef3 name: 'CPU status discovery' type: DEPENDENT key: cpu.discovery delay: '0' description: 'CPU status discovery.' item_prototypes: - uuid: 7f3a7fbad20e4d6f96d2d55e9987d92d name: 'CPU [{#CPU_FQDD}]: State' type: DEPENDENT key: 'dell.server.cpu.state[cpu.{#SNMPINDEX}]' delay: '0' description: 'This attribute defines the reading of the processor device status probe.' valuemap: name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.32.1.6.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.cpu.walk tags: - tag: component value: cpu trigger_prototypes: - uuid: 53311d57d9ea43cb9cc7494b51954143 expression: 'bitand(last(/DELL PowerEdge R740 by SNMP/dell.server.cpu.state[cpu.{#SNMPINDEX}],#1),128)=0' name: 'Dell R740: CPU [{#CPU_FQDD}]: Reading error' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 CPU probe reading flag is not `processorPresent`. tags: - tag: scope value: availability - uuid: bd6f4d52db2c415d9dbc97339c314fb8 name: 'CPU [{#CPU_FQDD}]: Status' type: DEPENDENT key: 'dell.server.cpu.status[cpu.{#SNMPINDEX}]' delay: '0' description: 'This attribute defines the status of the processor device status probe. This status will be joined into the `processorDeviceStatus` attribute.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.cpu.walk tags: - tag: component value: cpu trigger_prototypes: - uuid: a5318c7465244e34915cae82ba3c7143 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.cpu.status[cpu.{#SNMPINDEX}],#1)<>3' name: 'Dell R740: CPU [{#CPU_FQDD}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 CPU status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.cpu.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#CPU_FQDD}' - 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 7b6e0ea3ca9847318e9e2ac7dacb70e6 name: 'Fan discovery' type: DEPENDENT key: fan.discovery delay: '0' filter: conditions: - macro: '{#TYPE}' value: '3' formulaid: A description: 'Fan discovery.' item_prototypes: - uuid: 146df75c66474f11a1540d6cb174094c name: 'Fan [{#FAN_DESCR}]: Speed' type: DEPENDENT key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]' delay: '0' units: rpm description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a cooling device of a subtype other than `coolingDeviceSubTypeIsDiscrete`. When the value for `coolingDeviceSubType` is other than `coolingDeviceSubTypeIsDiscrete`, the value returned for this attribute is the speed in RPM or the "OFF/ON" value of the cooling device. When the value for `coolingDeviceSubType` is `coolingDeviceSubTypeIsDiscrete`, a value is not returned for this attribute. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.12.1.6.{#SNMPINDEX}' - '0' master_item: key: dell.server.fan.walk tags: - tag: component value: fan - uuid: cf5a92d04a694057bf596b5cf5e4af05 name: 'Fan [{#FAN_DESCR}]: Status' type: DEPENDENT key: 'dell.server.sensor.fan.status[{#FAN_DESCR}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the cooling device. valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.12.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.fan.walk tags: - tag: component value: fan trigger_prototypes: - uuid: 8477018dfab24e389f2fdf1ee0036e43 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' name: 'Dell R740: Fan [{#FAN_DESCR}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit.' tags: - tag: scope value: availability - uuid: 3da227c6a2e94e2f8631cee269d5a080 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R740: Fan [{#FAN_DESCR}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the fan unit.' dependencies: - name: 'Dell R740: Fan [{#FAN_DESCR}]: Critical state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.fan.status[{#FAN_DESCR}])={$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability graph_prototypes: - uuid: a6e39ba6f8d74833954a7adc6d7d14bc name: 'Dell R740: Fan [{#FAN_DESCR}]: Speed' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.sensor.fan.speed[{#FAN_DESCR}]' master_item: key: dell.server.fan.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.5 - '0' - '{#FAN_DESCR}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.8 - '0' - '{#TYPE}' - 1.3.6.1.4.1.674.10892.5.4.700.12.1.7 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 458cc1949b654938a932ccaeec481c67 name: 'Memory discovery' type: DEPENDENT key: memory.discovery delay: '0' description: 'Memory discovery.' item_prototypes: - uuid: f529edd65222419ca7f122787ca1e52a name: 'Memory [{#SNMPVALUE}]: Size' type: DEPENDENT key: 'dell.server.memory.size[{#SNMPVALUE}]' delay: '0' units: B description: 'This attribute defines the size, in KB, of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memory size.' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - type: MULTIPLIER parameters: - '1024' master_item: key: dell.server.memory.walk tags: - tag: component value: memory - uuid: 1c6b99e33fd3402da694f6ed6112fe77 name: 'Memory [{#SNMPVALUE}]: Status' type: DEPENDENT key: 'dell.server.memory.status[{#SNMPVALUE}]' delay: '0' description: 'This attribute defines the status of the memory device.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.memory.walk tags: - tag: component value: memory trigger_prototypes: - uuid: 8630f03f08ba45b3ade1065794d0dd25 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.memory.status[{#SNMPVALUE}],#1)<>3' name: 'Dell R740: Memory [{#SNMPVALUE}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 Memory status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.memory.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 46889540e5b74ea2b569e3efcb7bc3a8 name: 'Network interface discovery' type: DEPENDENT key: net.if.discovery delay: '0' description: 'Discovery of network interfaces.' item_prototypes: - uuid: e00bf0282cab4a6cad2cb076f7c1193d name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link status' type: DEPENDENT key: 'dell.server.net.if.link[{#NIC_FQDD}]' delay: '0' description: 'This attribute defines the connection status of the network device.' valuemap: name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.net.if.walk tags: - tag: component value: network trigger_prototypes: - uuid: 4f7bcd3f169f4d2794b4c2674a3ee183 expression: '{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1 and last(/DELL PowerEdge R740 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>1 and last(/DELL PowerEdge R740 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)<>last(/DELL PowerEdge R740 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#2)' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.net.if.link[{#NIC_FQDD}],#1)=1 or {$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=0' name: 'Dell R740: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Link down' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | This trigger expression works as follows: 1. It can be triggered if the operations status is Down. 2. `{$DELL.SNMP.IFCONTROL:"{#NIC_FQDD}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is Down. 3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for the "eternal off" interfaces.) manual_close: 'YES' tags: - tag: scope value: availability - uuid: 4d279ebb389d4d8da852f52194be6515 name: 'NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status' type: DEPENDENT key: 'dell.server.net.if.status[{#NIC_FQDD}]' delay: '0' description: 'This attribute defines the status of the network device.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.net.if.walk tags: - tag: component value: network trigger_prototypes: - uuid: 5e3abc09130e42aba1427e1b497d58e5 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.net.if.status[{#NIC_FQDD}],#1)<>3' name: 'Dell R740: NIC [{#NIC_FQDD}/{#NIC_MAC}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 Network interface status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.net.if.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#NIC_FQDD}' - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1 - '0' - '{#NIC_MAC}' - 1.3.6.1.4.1.674.10892.5.4.1100.90.1.15.1 - '2' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 732e223af8f94d6d894da0054c53fceb name: 'Physical disk discovery' type: DEPENDENT key: physicaldisk.discovery delay: '0' description: 'Physical disk discovery.' item_prototypes: - uuid: 611125e175c746bbbbdf01806afed47f name: 'Physical disk [{#DISK_NAME}]: Media type' type: DEPENDENT key: 'dell.server.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Drive (SSD). valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: b34f13ad1ec74d81915944ad95424b81 name: 'Physical disk [{#DISK_NAME}]: Model name' type: DEPENDENT key: 'dell.server.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The model number of the physical disk. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 06d3917a220f4e478f8f98331d308fd2 name: 'Physical disk [{#DISK_NAME}]: Serial number' type: DEPENDENT key: 'dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]' delay: '0' value_type: CHAR trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The physical disk's unique identification number from the manufacturer. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: df07ad54618b4b5db071f137edf18567 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0' name: 'Dell R740: Physical disk [{#DISK_NAME}] has been replaced' event_name: 'Dell R740: [{#DISK_NAME}] has been replaced (new serial number received)' priority: INFO description: '[{#DISK_NAME}] serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 66033914b4234e80abd5ff0125035078 name: 'Physical disk [{#DISK_NAME}]: Size' type: DEPENDENT key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]' delay: '0' trends: '0' units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the physical disk in megabytes. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage - uuid: 9f97e7dd51cd47d5966ac5d052e19766 name: 'Physical disk [{#DISK_NAME}]: S.M.A.R.T. Status' type: DEPENDENT key: 'dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 Indicates whether the physical disk has received a predictive failure alert. valuemap: name: 'IDRAC-MIB-SMIv2::BooleanType' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: cf5346652d2b46c1b03e778b93d46377 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}])={$DELL.SNMP.DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}' name: 'Dell R740: Physical disk [{#DISK_NAME}]: S.M.A.R.T. failed' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Disk probably requires replacement.' dependencies: - name: 'Dell R740: Physical disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability - uuid: 9d2326c1e4f844f1a1328046ab57765d name: 'Physical disk [{#DISK_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 The status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable valuemap: name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.physical.walk tags: - tag: component value: physicaldisk - tag: component value: storage trigger_prototypes: - uuid: 3c52af89a6eb466b9264ee55e1357962 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' name: 'Dell R740: Physical disk [{#DISK_NAME}]: Failed state' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check physical disk for warnings or errors.' tags: - tag: scope value: availability - uuid: c844585cd3d94a389cc5fae05430fa10 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}' name: 'Dell R740: Physical disk [{#DISK_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check physical disk for warnings or errors.' dependencies: - name: 'Dell R740: Physical disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"critical"} or last(/DELL PowerEdge R740 by SNMP/dell.server.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}])={$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' tags: - tag: scope value: availability graph_prototypes: - uuid: de00bac6c7fa44fdb26f02d8b4462841 name: 'Dell R740: Physical disk [{#DISK_NAME}]: Size' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]' master_item: key: dell.server.disk.physical.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 - '0' - '{#DISK_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: ceb2f7f14cd546c6af57ead8f9016c66 name: 'PSU discovery' type: DEPENDENT key: psu.discovery delay: '0' description: 'PSU discovery.' item_prototypes: - uuid: d1aa5fd364984c8ab42fd6a808d93bcc name: 'Power supply [{#PSU_DESCR}]: State' type: DEPENDENT key: 'dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]' delay: '0' trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the status of the power supply. valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.12.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.psu.walk tags: - tag: component value: psu trigger_prototypes: - uuid: ebd2ac9080434c619ee3fce7e009b8d5 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' name: 'Dell R740: Power supply [{#PSU_DESCR}]: Critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors.' tags: - tag: scope value: availability - uuid: 1a83756fc34b481fa1a54f6ac1ea4b90 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}' name: 'Dell R740: Power supply [{#PSU_DESCR}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the power supply unit for errors.' dependencies: - name: 'Dell R740: Power supply [{#PSU_DESCR}]: Critical state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"critical"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}])={$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' tags: - tag: scope value: availability master_item: key: dell.server.psu.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.600.12.1.5 - '0' - '{#PSU_DESCR}' - 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: bfee1b1ae17c446fbafa3ac47189d28f name: 'System battery discovery' type: DEPENDENT key: system.battery.discovery delay: '0' description: 'System battery discovery.' item_prototypes: - uuid: 19e1b59177674c4497044b86c0ac316a name: 'System battery [{#SNMPVALUE}]: Status' type: DEPENDENT key: 'dell.server.system.battery[{#SNMPVALUE}]' delay: '0' description: 'This attribute defines the status of the battery.' valuemap: name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.system.battery.walk tags: - tag: component value: battery trigger_prototypes: - uuid: eeabc8d55cf74ffc9849f4b9a98538b1 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.system.battery[{#SNMPVALUE}],#1)<>3' name: 'Dell R740: System battery [{#SNMPVALUE}]: Status is not OK' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: | MIB: IDRAC-MIB-SMIv2 System battery status is not OK. tags: - tag: scope value: availability master_item: key: dell.server.system.battery.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.600.50.1.7.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: b7562decf05249758d75961f54fdb497 name: 'Temperature discovery' type: DEPENDENT key: temp.discovery delay: '0' description: 'Temperature sensor discovery.' item_prototypes: - uuid: 43a2b5c2f47349cc8a9d194b5e7947d8 name: 'Probe [{#SENSOR_LOCALE}]: Status' type: DEPENDENT key: 'dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}]' delay: '0' value_type: FLOAT trends: '0' description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the probe status of the temperature probe. Possible values: other(1), -- probe status is not one of the following: unknown(2), -- probe status is unknown (not known or monitored) ok(3), -- probe is reporting a value within the thresholds nonCriticalUpper(4), -- probe has crossed the upper noncritical threshold criticalUpper(5), -- probe has crossed the upper critical threshold nonRecoverableUpper(6), -- probe has crossed the upper non-recoverable threshold nonCriticalLower(7), -- probe has crossed the lower noncritical threshold criticalLower(8), -- probe has crossed the lower critical threshold nonRecoverableLower(9), -- probe has crossed the lower non-recoverable threshold failed(10) -- probe is not functional valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.20.1.5.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.sensor.temp.walk tags: - tag: component value: temperature trigger_prototypes: - uuid: 70db3d2915764af99ae09b7121b9007b expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' name: 'Dell R740: Probe [{#SENSOR_LOCALE}]: Critical status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device for faults.' tags: - tag: scope value: availability - uuid: 2417be4d3f8b4ad781214a8644273267 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])<>{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}' name: 'Dell R740: Probe [{#SENSOR_LOCALE}]: Not in optimal status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the device for faults.' manual_close: 'YES' dependencies: - name: 'Dell R740: Probe [{#SENSOR_LOCALE}]: Critical status' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' - name: 'Dell R740: Probe [{#SENSOR_LOCALE}]: Warning status' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' tags: - tag: scope value: notice - uuid: ee60cc886e5445049e0ae7054d0d825d expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' name: 'Dell R740: Probe [{#SENSOR_LOCALE}]: Warning status' opdata: 'Current status: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for faults.' dependencies: - name: 'Dell R740: Probe [{#SENSOR_LOCALE}]: Critical status' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"} or last(/DELL PowerEdge R740 by SNMP/dell.server.sensor.temp.status[temperatureProbeStatus.{#SNMPINDEX}])={$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' tags: - tag: scope value: availability - uuid: c0b6aee515624a6eacd801af4100aade name: 'Probe [{#SENSOR_LOCALE}]: Value' type: DEPENDENT key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]' delay: '0' value_type: FLOAT units: °C description: | MIB: IDRAC-MIB-SMIv2 This attribute defines the reading for a temperature probe of type other than `temperatureProbeTypeIsDiscrete`. When the value for `temperatureProbeType` is other than `temperatureProbeTypeIsDiscrete`, the value returned for this attribute is the temperature that the probe is reading in Centigrade. When the value for `temperatureProbeType` is `temperatureProbeTypeIsDiscrete`, a value is not returned for this attribute. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.700.20.1.6.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '0.1' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.sensor.temp.walk tags: - tag: component value: temperature graph_prototypes: - uuid: 54313cfd1117447f9564987b2149bb8b name: 'Dell R740: Probe [{#SENSOR_LOCALE}]: Value' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.sensor.temp.value[temperatureProbeReading.{#SNMPINDEX}]' master_item: key: dell.server.sensor.temp.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.4.700.20.1.1 - '0' - '{#SENSOR_LOCALE}' - 1.3.6.1.4.1.674.10892.5.4.700.20.1.8 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 9c289d95dd7148238790b2359cf7c2f9 name: 'Virtual disk discovery' type: DEPENDENT key: virtualdisk.discovery delay: '0' description: 'Virtual disk discovery.' item_prototypes: - uuid: e191fd1c7e0348c5ae09c4d83b743388 name: 'Virtual disk [{#DISK_NAME}]: Layout type' type: DEPENDENT key: 'dell.server.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concatenated RAID 1 10: Concatenated RAID 5 valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 056f579ff9004f3fb9456b529ebb8c93 name: 'Virtual disk [{#DISK_NAME}]: Read policy' type: DEPENDENT key: 'dell.server.hw.virtualdisk.read_policy[virtualDiskReadPolicy.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: b769de369b154b20995d5b9240992d55 name: 'Virtual disk [{#DISK_NAME}]: Size' type: DEPENDENT key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]' delay: '0' trends: '0' units: B description: | MIB: IDRAC-MIB-SMIv2 The size of the virtual disk in megabytes. preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '1048576' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 465200ccf7f249069b2835feb974fb89 name: 'Virtual disk [{#DISK_NAME}]: Operational state' type: DEPENDENT key: 'dell.server.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3: A Consistency Check (CC) is being performed on the virtual disk. 4: The virtual disk is being initialized. 5: BackGround Initialization (BGI) is being performed on the virtual disk. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 3m master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk - uuid: 22df6ae9ce6f46198b646d9a240248f2 name: 'Virtual disk [{#DISK_NAME}]: Status' type: DEPENDENT key: 'dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtual disk is operating normally or optimally. 3: The virtual disk has encountered a failure. Data on the disk is lost or is about to be lost. 4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskState' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk trigger_prototypes: - uuid: edb04e1e12e2435db574928f7a8df0fa expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' name: 'Dell R740: Virtual disk [{#DISK_NAME}]: Failed state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the virtual disk for warnings or errors.' tags: - tag: scope value: availability - uuid: 0716847961e24d3e9ff009aead84c39a expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}' name: 'Dell R740: Virtual disk [{#DISK_NAME}]: Warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the virtual disk for warnings or errors.' dependencies: - name: 'Dell R740: Virtual disk [{#DISK_NAME}]: Failed state' expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}])={$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' tags: - tag: scope value: availability - uuid: 6cb2b0370662417eaf6059894e6cb582 name: 'Virtual disk [{#DISK_NAME}]: Write policy' type: DEPENDENT key: 'dell.server.hw.virtualdisk.write_policy[virtualDiskWritePolicy.{#SNMPINDEX}]' delay: '0' description: | MIB: IDRAC-MIB-SMIv2 The write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back. valuemap: name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10.{#SNMPINDEX}' - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h master_item: key: dell.server.disk.virtual.walk tags: - tag: component value: storage - tag: component value: virtualdisk graph_prototypes: - uuid: 3433748046f54048abadd9c85fb76a21 name: 'Dell R740: Virtual disk [{#DISK_NAME}]: Size' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]' master_item: key: dell.server.disk.virtual.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#SNMPVALUE}' - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1 - '0' - '{#DISK_NAME}' - 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2 - '0' error_handler: DISCARD_VALUE - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h - uuid: 66b27f55e9484eaf970bf5bdb02ef09b name: 'Voltage probe discovery' type: DEPENDENT key: voltage.discovery delay: '0' filter: evaltype: AND conditions: - macro: '{#VPROBE_NAME}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}' formulaid: A - macro: '{#VPROBE_NAME}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: B - macro: '{#VPROBE_TYPE}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}' formulaid: C - macro: '{#VPROBE_TYPE}' value: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: D description: 'Voltage probe discovery.' item_prototypes: - uuid: 3eae308500234ea0ac4e32a3046fffa6 name: 'Voltage probe [{#VPROBE_NAME}]: Status' type: DEPENDENT key: 'dell.server.voltage.status[{#VPROBE_NAME}]' delay: '0' description: 'This attribute defines the status of the voltage probe.' valuemap: name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}' - '0' master_item: key: dell.server.voltage.walk tags: - tag: component value: voltage trigger_prototypes: - uuid: 4e9fe74548d0436093a6343faaf06f00 expression: 'last(/DELL PowerEdge R740 by SNMP/dell.server.voltage.status[{#VPROBE_NAME}])<>3' name: 'Dell R740: Voltage probe [{#VPROBE_NAME}]: Status is not OK' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the device''s voltage.' tags: - tag: scope value: availability - uuid: 2d151ba0db394407b354bac35d94cae9 name: 'Voltage probe [{#VPROBE_NAME}]: Voltage' type: DEPENDENT key: 'dell.server.voltage.value[{#VPROBE_NAME}]' delay: '0' value_type: FLOAT units: V description: 'This attribute defines the reading for a voltage probe.' preprocessing: - type: SNMP_WALK_VALUE parameters: - '1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.{#SNMPINDEX}' - '0' - type: MULTIPLIER parameters: - '0.001' master_item: key: dell.server.voltage.walk tags: - tag: component value: voltage graph_prototypes: - uuid: 6477186594ae45d8824ec8a26d260b0c name: 'Dell R740: Voltage probe [{#VPROBE_NAME}]: Voltage' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.voltage.value[{#VPROBE_NAME}]' master_item: key: dell.server.voltage.walk preprocessing: - type: SNMP_WALK_TO_JSON parameters: - '{#VPROBE_NAME}' - 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1 - '0' - '{#VPROBE_TYPE}' - 1.3.6.1.4.1.674.10892.5.4.600.20.1.7.1 - '0' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: class value: hardware - tag: target value: dell - tag: target value: 'dell poweredge' macros: - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.MATCHES}' value: '^.*Voltage.*$' description: 'Sets the regex string of voltage probe names to allow in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.NAME.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'Sets the regex string of voltage probe names to ignore in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.MATCHES}' value: 18|16 description: 'Sets the regex string of voltage probe types to allow in discovery.' - macro: '{$DELL.SNMP.DISCOVERY.VOLTAGE.TYPE.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'Sets the regex string of voltage probe types to ignore in discovery.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT}' value: '3' description: 'The critical status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.OK}' value: '2' description: 'The OK status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.CACHE.BATTERY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array cache battery for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.CRIT}' value: '5' description: 'The critical status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.FAIL}' value: '6' description: 'The disaster status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.ARRAY.STATUS.WARN}' value: '4' description: 'The warning status of the disk array for the trigger expression.' - macro: '{$DELL.SNMP.DISK.SMART.STATUS.FAIL}' value: '1' description: 'The critical S.M.A.R.T status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"critical"}' value: '5' description: 'The critical status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.FAIL:"nonRecoverable"}' value: '6' description: 'The critical status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.DISK.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning status of the disk for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"failed"}' value: '10' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.FAN.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning value of the FAN sensor for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.CRIT}' value: '5' description: 'The critical status of health for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.DISASTER}' value: '6' description: 'The disaster status of health for the trigger expression.' - macro: '{$DELL.SNMP.HEALTH.STATUS.WARN}' value: '4' description: 'The warning status of health for the trigger expression.' - macro: '{$DELL.SNMP.IFCONTROL}' value: '1' description: 'The link status trigger will be fired only for interfaces that have the context macro equal to "1".' - macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"critical"}' value: '5' description: 'The critical value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.PSU.STATUS.CRIT:"nonRecoverable"}' value: '6' description: 'The critical value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.PSU.STATUS.WARN:"nonCritical"}' value: '4' description: 'The warning value of the PSU sensor for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalLower"}' value: '8' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"criticalUpper"}' value: '5' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableLower"}' value: '9' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.CRIT:"nonRecoverableUpper"}' value: '6' description: 'The critical status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.OK}' value: '3' description: 'The OK status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalLower"}' value: '7' description: 'The warning status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.SENSOR.TEMP.STATUS.WARN:"nonCriticalUpper"}' value: '4' description: 'The warning status of the temperature probe for the trigger expression.' - macro: '{$DELL.SNMP.TIMEOUT}' value: 5m description: 'The time interval for the SNMP agent availability trigger expression.' - macro: '{$DELL.SNMP.VDISK.STATUS.CRIT:"failed"}' value: '3' description: 'The critical status of the virtual disk for the trigger expression.' - macro: '{$DELL.SNMP.VDISK.STATUS.WARN:"degraded"}' value: '4' description: 'The warning status of the virtual disk for the trigger expression.' dashboards: - uuid: a02b71d3f0c94112b685d6be23e2dc84 name: Overview pages: - name: Overview display_period: '30' widgets: - type: item name: 'System health' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'System Health' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.status[globalSystemStatus]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: 'Serial number' 'y': '4' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'Serial number' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.hw.serialnumber[systemServiceTag]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: 'HW model' x: '36' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: 'HW model' - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.hw.model[systemModelName]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - type: item name: Firmware x: '36' 'y': '4' width: '36' height: '4' hide_header: 'YES' fields: - type: STRING name: bg_color value: 2196F3 - type: STRING name: description value: Firmware - type: STRING name: desc_color value: FFFFFF - type: INTEGER name: desc_v_pos value: '0' - type: ITEM name: itemid.0 value: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.hw.firmware[racFirmwareVersion]' - type: INTEGER name: show.0 value: '2' - type: INTEGER name: show.1 value: '1' - type: STRING name: value_color value: FFFFFF - type: INTEGER name: value_size value: '35' - name: Discoveries display_period: '30' widgets: - type: honeycomb name: 'Interface link' width: '72' height: '4' fields: - type: STRING name: items.0 value: 'NIC*Link status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size value: '15' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAA - type: STRING name: thresholds.0.color value: 069C56 - type: STRING name: thresholds.0.threshold value: '1' - type: STRING name: thresholds.1.color value: FF681E - type: STRING name: thresholds.1.threshold value: '2' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '3' - type: honeycomb name: 'Temperature sensors' 'y': '4' width: '72' height: '4' fields: - type: STRING name: items.0 value: 'Probe*Value' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAB - type: INTEGER name: secondary_label_decimal_places value: '0' - type: honeycomb name: 'Physical disks' 'y': '8' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Physical disk*: Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size value: '15' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAC - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '0' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '3' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '4' - type: honeycomb name: 'Power supplies' 'y': '12' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Voltage probe*Voltage' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAE - type: honeycomb name: 'Virtual disks' x: '36' 'y': '8' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Virtual disk*: Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAD - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '1' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '2' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '3' - type: honeycomb name: Fans x: '36' 'y': '12' width: '36' height: '4' fields: - type: STRING name: items.0 value: 'Fan*Status' - type: STRING name: primary_label value: '{{ITEM.NAME}.regsub("\[(.*?)\]", "\1")}' - type: INTEGER name: primary_label_size_type value: '1' - type: STRING name: reference value: AAAAF - type: STRING name: thresholds.0.color value: FF980E - type: STRING name: thresholds.0.threshold value: '0' - type: STRING name: thresholds.1.color value: 069C56 - type: STRING name: thresholds.1.threshold value: '3' - type: STRING name: thresholds.2.color value: D3212C - type: STRING name: thresholds.2.threshold value: '4' valuemaps: - uuid: 557381876b894611bf213f55946b49a1 name: 'IDRAC-MIB-SMIv2::batteryState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Ready - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - value: '5' newvalue: Missing - value: '6' newvalue: Charging - value: '7' newvalue: 'Below threshold' - uuid: 39a00987a4e14c0286acd9942db37e03 name: 'IDRAC-MIB-SMIv2::BooleanType' mappings: - value: '0' newvalue: ok - value: '1' newvalue: failed - uuid: 9dbe9b652e7746229cf5ef744a67c566 name: 'IDRAC-MIB-SMIv2::NetworkDeviceConnectionStatusEnum' mappings: - value: '0' newvalue: unknown - value: '1' newvalue: connected - value: '2' newvalue: disconnected - value: '3' newvalue: driverBad - value: '4' newvalue: driverDisabled - value: '10' newvalue: hardwareInitalizing - value: '11' newvalue: hardwareResetting - value: '12' newvalue: hardwareClosing - value: '13' newvalue: hardwareNotReady - uuid: ac53b62fdab246aa807e234ae9982102 name: 'IDRAC-MIB-SMIv2::ObjectStatusEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: 432abc8431e0438696cd1b96d3515a5c name: 'IDRAC-MIB-SMIv2::physicalDiskComponentStatus' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCritical - value: '5' newvalue: critical - value: '6' newvalue: nonRecoverable - uuid: 8aa7cecdd0944b91b8cdcba75e28d781 name: 'IDRAC-MIB-SMIv2::physicalDiskMediaType' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: HDD - value: '3' newvalue: SSD - uuid: 1c683fea74b645ed9f42d8fcd6edf442 name: 'IDRAC-MIB-SMIv2::ProcessorDeviceStatusReadingFlags' mappings: - value: '1' newvalue: internalError - value: '2' newvalue: thermalTrip - value: '32' newvalue: configurationError - value: '128' newvalue: processorPresent - value: '256' newvalue: processorDisabled - value: '512' newvalue: terminatorPresent - value: '1024' newvalue: processorThrottled - uuid: b096a16930734ec28bc0a5a5e7634783 name: 'IDRAC-MIB-SMIv2::StatusProbeEnum' mappings: - value: '1' newvalue: other - value: '2' newvalue: unknown - value: '3' newvalue: ok - value: '4' newvalue: nonCriticalUpper - value: '5' newvalue: criticalUpper - value: '6' newvalue: nonRecoverableUpper - value: '7' newvalue: nonCriticalLower - value: '8' newvalue: criticalLower - value: '9' newvalue: nonRecoverableLower - value: '10' newvalue: failed - uuid: 3fcb8ac498564f068c4b30f3423fbe8c name: 'IDRAC-MIB-SMIv2::virtualDiskLayout' mappings: - value: '1' newvalue: Other - value: '2' newvalue: RAID-0 - value: '3' newvalue: RAID-1 - value: '4' newvalue: RAID-5 - value: '5' newvalue: RAID-6 - value: '6' newvalue: RAID-10 - value: '7' newvalue: RAID-50 - value: '8' newvalue: RAID-60 - value: '9' newvalue: 'Concatenated RAID 1' - value: '10' newvalue: 'Concatenated RAID 5' - uuid: 6850d7335f6c423b87527a1a0252d00f name: 'IDRAC-MIB-SMIv2::virtualDiskOperationalState' mappings: - value: '1' newvalue: 'Not applicable' - value: '2' newvalue: Reconstructing - value: '3' newvalue: Resynching - value: '4' newvalue: Initializing - value: '5' newvalue: 'Background init' - uuid: 076e6a30b90c49e9bcbb8a1adbc0b02d name: 'IDRAC-MIB-SMIv2::virtualDiskReadPolicy' mappings: - value: '1' newvalue: 'No Read Ahead' - value: '2' newvalue: 'Read Ahead' - value: '3' newvalue: 'Adaptive Read Ahead' - uuid: 4699f81ffa784d43b8e74aeb258a15cb name: 'IDRAC-MIB-SMIv2::virtualDiskState' mappings: - value: '1' newvalue: Unknown - value: '2' newvalue: Online - value: '3' newvalue: Failed - value: '4' newvalue: Degraded - uuid: 15f75cf464d347308db357fa80e67f0e name: 'IDRAC-MIB-SMIv2::virtualDiskWritePolicy' mappings: - value: '1' newvalue: 'Write Through' - value: '2' newvalue: 'Write Back' - value: '3' newvalue: 'Force Write Back' - uuid: cf94dd75c6274a2aaff23e3a26eee213 name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown triggers: - uuid: 88a6132f78a24d8ca66e8759526c2381 expression: '(last(/DELL PowerEdge R740 by SNMP/dell.server.hw.uptime[systemPowerUpTime])>0 and last(/DELL PowerEdge R740 by SNMP/dell.server.hw.uptime[systemPowerUpTime])<10m) or (last(/DELL PowerEdge R740 by SNMP/dell.server.hw.uptime[systemPowerUpTime])=0 and last(/DELL PowerEdge R740 by SNMP/dell.server.net.uptime[snmpEngineTime])<10m)' name: 'Dell R740: Host has been restarted' event_name: 'Dell R740: {HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes.' manual_close: 'YES' tags: - tag: scope value: notice graphs: - uuid: 0b67dc9462dd4bb6beebe9a8c0b5001f name: 'Dell R740: Uptime' graph_items: - color: 199C0D item: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.hw.uptime[systemPowerUpTime]' - sortorder: '1' color: F63100 item: host: 'DELL PowerEdge R740 by SNMP' key: 'dell.server.net.uptime[snmpEngineTime]'