zabbix_export: version: '7.0' template_groups: - uuid: 36bff6c29af64692839d077febfc7079 name: 'Templates/Network devices' templates: - uuid: f744679600844c07b2b4eedda9bc3d0c template: 'Cisco Catalyst 3750V2-48TS by SNMP' name: 'Cisco Catalyst 3750V2-48TS by SNMP' description: | Template Cisco Catalyst 3750V2-48TS MIBs used: CISCO-MEMORY-POOL-MIB IF-MIB EtherLike-MIB SNMPv2-MIB CISCO-PROCESS-MIB CISCO-ENVMON-MIB ENTITY-MIB You can discuss this template or leave feedback on our forum https://www.zabbix.com/forum/zabbix-suggestions-and-feedback/418396-discussion-thread-for-official-zabbix-templates-for-cisco Generated by official Zabbix template tool "Templator" vendor: name: Zabbix version: 7.0-4 groups: - name: 'Templates/Network devices' items: - uuid: 5d096334d7e2455797c9a5a46fecfaec name: 'ICMP ping' type: SIMPLE key: icmpping valuemap: name: 'Service state' tags: - tag: component value: health - tag: component value: network triggers: - uuid: 1dd6a211f5e54351a2d4a0854e66fdba expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/icmpping,#3)=0' name: 'Cisco Catalyst 3750V2-48TS: Unavailable by ICMP ping' priority: HIGH description: 'Last three attempts returned timeout. Please check device connectivity.' tags: - tag: scope value: availability - uuid: a88b7bcaa2174a76b09031993ee48fb4 name: 'ICMP loss' type: SIMPLE key: icmppingloss value_type: FLOAT units: '%' tags: - tag: component value: health - tag: component value: network triggers: - uuid: 669ae230efe84f76be95f3ac0eac1102 expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)<100' name: 'Cisco Catalyst 3750V2-48TS: High ICMP ping loss' opdata: 'Loss: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Cisco Catalyst 3750V2-48TS: Unavailable by ICMP ping' expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/icmpping,#3)=0' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 906ca6fa0cf64000bac2efbc0f5dc7f9 name: 'ICMP response time' type: SIMPLE key: icmppingsec value_type: FLOAT units: s tags: - tag: component value: health - tag: component value: network triggers: - uuid: 391b3ac9e1b746c8824af721c472df7b expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' name: 'Cisco Catalyst 3750V2-48TS: High ICMP ping response time' opdata: 'Value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Cisco Catalyst 3750V2-48TS: High ICMP ping loss' expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco Catalyst 3750V2-48TS by SNMP/icmppingloss,5m)<100' - name: 'Cisco Catalyst 3750V2-48TS: Unavailable by ICMP ping' expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/icmpping,#3)=0' tags: - tag: scope value: availability - tag: scope value: performance - uuid: bc9c48b56cc6405c8256566d4768903a name: 'SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback delay: '0' value_type: LOG trends: '0' description: 'Item is used to collect all SNMP traps unmatched by other snmptrap items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: component value: system - uuid: 19896943dda74f798241c176b1f4fc4f name: 'System contact details' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.4.0]' key: system.contact delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. inventory_link: CONTACT preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: c4bd78d5e1f442128eddcdf4ea22d4b3 name: 'System description' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.1.0]' key: system.descr delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: 58642d7727964ba48f41bc33cfb6ef37 name: 'Hardware model name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.13.1]' key: system.hw.model delay: 1h value_type: CHAR trends: '0' description: 'MIB: ENTITY-MIB' inventory_link: MODEL preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system - uuid: 7fa7b4e4803e4eed932c176afed56cd5 name: 'Hardware serial number' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.11.1]' key: system.hw.serialnumber delay: 1h value_type: CHAR trends: '0' description: 'MIB: ENTITY-MIB' inventory_link: SERIALNO_A preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: f63ea5e9c33f465985259c3c8d27a12a expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber))>0' name: 'Cisco Catalyst 3750V2-48TS: Device has been replaced' event_name: 'Cisco Catalyst 3750V2-48TS: Device has been replaced (new serial number received)' priority: INFO description: 'The device serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: f00b81685e5d41f49561b62d710e247f name: 'Uptime (hardware)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]' key: system.hw.uptime trends: '0' units: uptime description: | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. preprocessing: - type: CHECK_NOT_SUPPORTED parameters: - '-1' error_handler: CUSTOM_VALUE error_handler_params: '0' - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: system - uuid: 213f54a3c23c40aa8693169efd8c0d82 name: 'System location' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.6.0]' key: system.location delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. inventory_link: LOCATION preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: system - uuid: 7e325f94720f4b29ad83a741a3735fa1 name: 'System name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.5.0]' key: system.name delay: 1h value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. inventory_link: NAME preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: system triggers: - uuid: 55ff869f6acb4f2daddf5c855aa3d76d expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name))>0' name: 'Cisco Catalyst 3750V2-48TS: System name has changed' event_name: 'Cisco Catalyst 3750V2-48TS: System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'The name of the system has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: d33f3f14dfff49d88269706ab464e2b9 name: 'Uptime (network)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.3.0]' key: system.net.uptime trends: '0' units: uptime description: | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: system - uuid: 2fce50826a7d498abe4ca628021fb9ac name: 'System object ID' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.2.0]' key: system.objectid value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: system - uuid: 0d55299054304e658dc036f234727c73 name: 'Operating system' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.1.0]' key: system.sw.os delay: 1h value_type: CHAR trends: '0' description: 'MIB: SNMPv2-MIB' inventory_link: OS preprocessing: - type: REGEX parameters: - 'Version (.+), RELEASE' - \1 - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 6724cfef1df145fdb0e6e2cfb35bc890 expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.sw.os))>0' recovery_mode: NONE name: 'Cisco Catalyst 3750V2-48TS: Operating system description has changed' priority: INFO description: 'The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually.' manual_close: 'YES' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: System name has changed' expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name,#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.name))>0' tags: - tag: scope value: notice - uuid: 82c87e2ade594f68abc4861e4d328a16 name: 'SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' valuemap: name: zabbix.host.available tags: - tag: component value: system triggers: - uuid: da0596afe59b455bb503a0b2dea1cebe expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'Cisco Catalyst 3750V2-48TS: No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' tags: - tag: scope value: availability discovery_rules: - uuid: f472cb3505b34f14b84bc1ce69f66b29 name: 'CPU discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.109.1.1.1.1.5]' key: cpu.discovery delay: 1h description: | If your IOS device has several CPUs, you must use CISCO-PROCESS-MIB and its object cpmCPUTotal5minRev from the table called cpmCPUTotalTable , indexed with cpmCPUTotalIndex . This table allows CISCO-PROCESS-MIB to keep CPU statistics for different physical entities in the router, like different CPU chips, group of CPUs, or CPUs in different modules/cards. In case of a single CPU, cpmCPUTotalTable has only one entry. item_prototypes: - uuid: 71248adcae1247fb8fe96ff83505b72a name: '#{#SNMPINDEX}: CPU utilization' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.9.9.109.1.1.1.1.8.{#SNMPINDEX}]' key: 'system.cpu.util[{#SNMPINDEX}]' delay: 5m value_type: FLOAT units: '%' description: | MIB: CISCO-PROCESS-MIB Object name: cpmCPUTotal5minRev The cpmCPUTotal5minRev MIB object provides a more accurate view of the performance of the router over time than the MIB objects cpmCPUTotal1minRev and cpmCPUTotal5secRev . These MIB objects are not accurate because they look at CPU at one minute and five second intervals, respectively. These MIBs enable you to monitor the trends and plan the capacity of your network. The recommended baseline rising threshold for cpmCPUTotal5minRev is 90 percent. Depending on the platform, some routers that run at 90 percent, for example, 2500s, can exhibit performance degradation versus a high-end router, for example, the 7500 series, which can operate fine. Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15215-collect-cpu-util-snmp.html tags: - tag: component value: cpu - tag: cpu-index value: '{#SNMPINDEX}' trigger_prototypes: - uuid: 194c2d8b74c94717a037ce22c31a50e6 expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/system.cpu.util[{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT}' name: 'Cisco Catalyst 3750V2-48TS: #{#SNMPINDEX}: High CPU utilization' event_name: 'Cisco Catalyst 3750V2-48TS: #{#SNMPINDEX}: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)' opdata: 'Current utilization: {ITEM.LASTVALUE1}' priority: WARNING description: 'The CPU utilization is too high. The system might be slow to respond.' tags: - tag: scope value: capacity - tag: scope value: performance graph_prototypes: - uuid: af1ac970bce54108bec634e986711c65 name: '#{#SNMPINDEX}: CPU utilization' ymin_type_1: FIXED ymax_type_1: FIXED graph_items: - drawtype: GRADIENT_LINE color: 1A7C11 item: host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'system.cpu.util[{#SNMPINDEX}]' - uuid: 7b40466007144e82ba7b6081d9d024ae name: 'Entity Serial Numbers discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#ENT_CLASS},1.3.6.1.2.1.47.1.1.1.1.5,{#ENT_NAME},1.3.6.1.2.1.47.1.1.1.1.7,{#ENT_SN},1.3.6.1.2.1.47.1.1.1.1.11]' key: entity_sn.discovery delay: 1h filter: evaltype: AND conditions: - macro: '{#ENT_CLASS}' value: '[^3]' formulaid: A - macro: '{#ENT_SN}' value: .+ formulaid: B item_prototypes: - uuid: c08c86fa7d1a4f16b51a8212eb98826f name: '{#ENT_NAME}: Hardware serial number' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.47.1.1.1.1.11.{#SNMPINDEX}]' key: 'system.hw.serialnumber[{#SNMPINDEX}]' delay: 1h value_type: CHAR trends: '0' description: | MIB: ENTITY-MIB Object name: entPhysicalSerialNum preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: serial-number - tag: entity value: '{#ENT_NAME}' trigger_prototypes: - uuid: 7dc178a7bced4003b51b599459e41047 expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#1)<>last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}],#2) and length(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.serialnumber[{#SNMPINDEX}]))>0' name: 'Cisco Catalyst 3750V2-48TS: {#ENT_NAME}: Device has been replaced' event_name: 'Cisco Catalyst 3750V2-48TS: {#ENT_NAME}: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 4972e929a2e84bc1bf37f8844aa640d2 name: 'FAN discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.4.1.2]' key: fan.discovery delay: 1h description: 'The table of fan status maintained by the environmental monitor.' item_prototypes: - uuid: 6bc5cda2b5fa487d8841f6f9d07899e3 name: '{#SNMPVALUE}: Fan status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.4.1.3.{#SNMPINDEX}]' key: 'sensor.fan.status[{#SNMPINDEX}]' description: | MIB: CISCO-ENVMON-MIB Object name: ciscoEnvMonFanState valuemap: name: 'CISCO-ENVMON-MIB::CiscoEnvMonState' tags: - tag: component value: fan - tag: fan value: '{#SNMPVALUE}' trigger_prototypes: - uuid: 16d0712d6e1f4cb18a65d4cc7e11a8df expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Fan is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 42ad0109072e404eb47daaf17236d805 expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=2' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Fan is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the fan unit' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Fan is in critical state' expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.fan.status[{#SNMPINDEX}])=4' tags: - tag: scope value: availability - tag: scope value: performance - uuid: d5c08c7436a44b74b35c4dd5be5c308a name: 'Memory discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.48.1.1.1.2]' key: memory.discovery delay: 1h description: | Discovery of ciscoMemoryPoolTable, a table of memory pool monitoring entries. http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html item_prototypes: - uuid: 3520b5d6482145958337956cb29d5dad name: '{#SNMPVALUE}: Free memory' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.9.9.48.1.1.1.6.{#SNMPINDEX}]' key: 'vm.memory.free[{#SNMPINDEX}]' units: B description: | MIB: CISCO-MEMORY-POOL-MIB Object name: ciscoMemoryPoolFree Indicates the number of bytes from the memory pool that are currently unused on the managed device. Note that the sum of ciscoMemoryPoolUsed and ciscoMemoryPoolFree is the total amount of memory in the pool Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html tags: - tag: component value: memory - tag: memory value: '{#SNMPVALUE}' - uuid: 5317e1db040846728cf05f3b7fe5dcab name: '{#SNMPVALUE}: Used memory' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.9.9.48.1.1.1.5.{#SNMPINDEX}]' key: 'vm.memory.used[{#SNMPINDEX}]' units: B description: | MIB: CISCO-MEMORY-POOL-MIB Object name: ciscoMemoryPoolUsed Indicates the number of bytes from the memory pool that are currently in use by applications on the managed device. Reference: http://www.cisco.com/c/en/us/support/docs/ip/simple-network-management-protocol-snmp/15216-contiguous-memory.html tags: - tag: component value: memory - tag: memory value: '{#SNMPVALUE}' - uuid: 9120f609d03f44c68c5c34177745422c name: '{#SNMPVALUE}: Memory utilization' type: CALCULATED key: 'vm.memory.util[{#SNMPINDEX}]' value_type: FLOAT units: '%' params: 'last(//vm.memory.used[{#SNMPINDEX}])/(last(//vm.memory.free[{#SNMPINDEX}])+last(//vm.memory.used[{#SNMPINDEX}]))*100' description: 'Memory utilization in %' tags: - tag: component value: memory - tag: memory value: '{#SNMPVALUE}' trigger_prototypes: - uuid: 8cf907c229fa4c4c86c1f06e65facef8 expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/vm.memory.util[{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: High memory utilization' event_name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: High memory utilization ( >{$MEMORY.UTIL.MAX}% for 5m)' priority: AVERAGE description: 'The system is running out of free memory.' tags: - tag: scope value: capacity - tag: scope value: performance graph_prototypes: - uuid: 5d8987ea729748048c3fb5381c6930aa name: '{#SNMPVALUE}: Memory utilization' ymin_type_1: FIXED ymax_type_1: FIXED graph_items: - drawtype: GRADIENT_LINE color: 1A7C11 item: host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'vm.memory.util[{#SNMPINDEX}]' - uuid: c0be105de4db4c0182833e6a7e0fcd01 name: 'Network interfaces discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]' key: net.if.discovery delay: 1h filter: evaltype: AND conditions: - macro: '{#IFADMINSTATUS}' value: '{$NET.IF.IFADMINSTATUS.MATCHES}' formulaid: A - macro: '{#IFADMINSTATUS}' value: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: B - macro: '{#IFALIAS}' value: '{$NET.IF.IFALIAS.MATCHES}' formulaid: C - macro: '{#IFALIAS}' value: '{$NET.IF.IFALIAS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: D - macro: '{#IFDESCR}' value: '{$NET.IF.IFDESCR.MATCHES}' formulaid: E - macro: '{#IFDESCR}' value: '{$NET.IF.IFDESCR.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: F - macro: '{#IFNAME}' value: '{$NET.IF.IFNAME.MATCHES}' formulaid: G - macro: '{#IFNAME}' value: '{$NET.IF.IFNAME.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: H - macro: '{#IFOPERSTATUS}' value: '{$NET.IF.IFOPERSTATUS.MATCHES}' formulaid: I - macro: '{#IFOPERSTATUS}' value: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: J - macro: '{#IFTYPE}' value: '{$NET.IF.IFTYPE.MATCHES}' formulaid: K - macro: '{#IFTYPE}' value: '{$NET.IF.IFTYPE.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: L description: 'Discovering interfaces from IF-MIB.' item_prototypes: - uuid: 06f850ef11f24e79be813a8b79e25d91 name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}]' key: 'net.if.in.discards[{#SNMPINDEX}]' description: | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 216cd11617ce4fcb9551cbada0189919 name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}]' key: 'net.if.in.errors[{#SNMPINDEX}]' description: | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: f4fa2946c04d4bdbabc9be4b492cf5f0 expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8' name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): High input error rate' event_name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): High input error rate ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)' opdata: 'errors in: {ITEM.LASTVALUE1}' priority: WARNING description: 'It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.' manual_close: 'YES' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope value: performance - uuid: 9dfdb09ca395486b9b71f1e3d74b8f5a name: 'Interface {#IFNAME}({#IFALIAS}): Bits received' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}]' key: 'net.if.in[{#SNMPINDEX}]' units: bps description: | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' - type: MULTIPLIER parameters: - '8' tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 69fffa684b344774877ccb05e80fa0ab name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}]' key: 'net.if.out.discards[{#SNMPINDEX}]' description: | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: ce6a12b2553d456b87738efeb43ca849 name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}]' key: 'net.if.out.errors[{#SNMPINDEX}]' description: | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: a14d914fa1404daab227b6d22e71ea69 expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out.errors[{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8' name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): High output error rate' event_name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): High output error rate ( > {$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)' opdata: 'errors out: {ITEM.LASTVALUE2}' priority: WARNING description: 'It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.' manual_close: 'YES' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope value: performance - uuid: eee4285b410f470f82e05c8f0cbc97b5 name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}]' key: 'net.if.out[{#SNMPINDEX}]' units: bps description: | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' - type: MULTIPLIER parameters: - '8' tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: b95c3c8730434b58a1a03c661c767901 name: 'Interface {#IFNAME}({#IFALIAS}): Speed' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}]' key: 'net.if.speed[{#SNMPINDEX}]' units: bps description: | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero. preprocessing: - type: MULTIPLIER parameters: - '1000000' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 28cb37005e6c46eaa636b5de0b7b5c8d name: 'Interface {#IFNAME}({#IFALIAS}): Operational status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}]' key: 'net.if.status[{#SNMPINDEX}]' description: | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. valuemap: name: 'IF-MIB::ifOperStatus' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: 77b810108caa4ae6bd8d8bff06acddb2 expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): Link down' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: | This trigger expression works as follows: 1. It can be triggered if the operations status is down. 2. `{ $IFCONTROL:"{#IFNAME}" }=1` - a user can redefine context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down. manual_close: 'YES' tags: - tag: scope value: availability - uuid: 73d4de02c2e84a75acd66e33d98f6180 name: 'Interface {#IFNAME}({#IFALIAS}): Interface type' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}]' key: 'net.if.type[{#SNMPINDEX}]' description: | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. valuemap: name: 'IF-MIB::ifType' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 6h tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: 4eae529fc032412d957f1e0d04261867 expression: | change(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])<0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 and ( last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=6 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=7 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=11 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=62 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=69 or last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.type[{#SNMPINDEX}])=117 ) and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])<>2) recovery_mode: RECOVERY_EXPRESSION recovery_expression: | (change(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}],#2)>0) or (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2) name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before' opdata: 'Current reported speed: {ITEM.LASTVALUE1}' priority: INFO description: 'This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually.' manual_close: 'YES' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope value: notice - uuid: 4e1ee888558346faa54c02b85d320170 expression: | (avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])) and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.in[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])' name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage' event_name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): High inbound bandwidth usage ( > {$IF.UTIL.MAX:"{#IFNAME}"}% )' opdata: 'In: {ITEM.LASTVALUE1}, speed: {ITEM.LASTVALUE2}' priority: WARNING description: 'The utilization of the network interface is close to its estimated maximum bandwidth.' manual_close: 'YES' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope value: performance - uuid: 7623796067224187b6f692c8b6cbd398 expression: | (avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out[{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])) and last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])>0 recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.out[{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.speed[{#SNMPINDEX}])' name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage' event_name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): High outbound bandwidth usage ( > {$IF.UTIL.MAX:"{#IFNAME}"}% )' opdata: 'Out: {ITEM.LASTVALUE1}, speed: {ITEM.LASTVALUE2}' priority: WARNING description: 'The utilization of the network interface is close to its estimated maximum bandwidth.' manual_close: 'YES' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and (last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.status[{#SNMPINDEX}])=2)' tags: - tag: scope value: performance graph_prototypes: - uuid: 2f07fa8de9f94fdfab762af30d7ac17a name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic' graph_items: - drawtype: GRADIENT_LINE color: 1A7C11 item: host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.in[{#SNMPINDEX}]' - sortorder: '1' drawtype: BOLD_LINE color: 2774A4 item: host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.out[{#SNMPINDEX}]' - sortorder: '2' color: F63100 yaxisside: RIGHT item: host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.out.errors[{#SNMPINDEX}]' - sortorder: '3' color: A54F10 yaxisside: RIGHT item: host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.in.errors[{#SNMPINDEX}]' - sortorder: '4' color: FC6EA3 yaxisside: RIGHT item: host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.out.discards[{#SNMPINDEX}]' - sortorder: '5' color: 6C59DC yaxisside: RIGHT item: host: 'Cisco Catalyst 3750V2-48TS by SNMP' key: 'net.if.in.discards[{#SNMPINDEX}]' - uuid: 15992a60957c4ef896ece23744da52f1 name: 'EtherLike discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.2.1.10.7.2.1.19,{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2]' key: net.if.duplex.discovery delay: 1h filter: evaltype: AND conditions: - macro: '{#IFOPERSTATUS}' value: '1' formulaid: A - macro: '{#SNMPVALUE}' value: (2|3) formulaid: B description: 'Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered.' item_prototypes: - uuid: 530a9cfa68024c1e8ad6573573c8f2b7 name: 'Interface {#IFNAME}({#IFALIAS}): Duplex status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.10.7.2.1.19.{#SNMPINDEX}]' key: 'net.if.duplex[{#SNMPINDEX}]' description: | MIB: EtherLike-MIB Object name: dot3StatsDuplexStatus The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. valuemap: name: 'EtherLike-MIB::dot3StatsDuplexStatus' tags: - tag: component value: interface - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: a1217d320897464da4bb9a67f669460f expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/net.if.duplex[{#SNMPINDEX}])=2' name: 'Cisco Catalyst 3750V2-48TS: Interface {#IFNAME}({#IFALIAS}): In half-duplex mode' priority: WARNING description: 'Please check autonegotiation settings and cabling' manual_close: 'YES' tags: - tag: scope value: performance - uuid: d2658fe23d274233accf16090273118f name: 'PSU discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.5.1.2]' key: psu.discovery delay: 1h description: 'The table of power supply status maintained by the environmental monitor card.' item_prototypes: - uuid: b87fda0166dc4baa9c24124dae6cea5c name: '{#SNMPVALUE}: Power supply status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.5.1.3.{#SNMPINDEX}]' key: 'sensor.psu.status[{#SNMPINDEX}]' description: | MIB: CISCO-ENVMON-MIB Object name: ciscoEnvMonSupplyState valuemap: name: 'CISCO-ENVMON-MIB::CiscoEnvMonState' tags: - tag: component value: power - tag: power-supply value: '{#SNMPVALUE}' trigger_prototypes: - uuid: 56fced6c99ba44ab9fb5268d946a385b expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Power supply is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors' tags: - tag: scope value: availability - uuid: 6962e5851f244e9cb9d87763637a20f3 expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=2' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Power supply is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the power supply unit for errors' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Power supply is in critical state' expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.psu.status[{#SNMPINDEX}])=4' tags: - tag: scope value: availability - uuid: ab60f4a103254b2c87f260014ecd1a28 name: 'Temperature discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.9.9.13.1.3.1.2]' key: temperature.discovery delay: 1h description: | Discovery of ciscoEnvMonTemperatureTable (ciscoEnvMonTemperatureDescr), a table of ambient temperature status maintained by the environmental monitor. item_prototypes: - uuid: 2b2423e625914a4f89b16faaed832bae name: '{#SNMPVALUE}: Temperature status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.3.1.6.{#SNMPINDEX}]' key: 'sensor.temp.status[{#SNMPINDEX}]' description: | MIB: CISCO-ENVMON-MIB Object name: ciscoEnvMonTemperatureState The current state of the test point being instrumented. valuemap: name: 'CISCO-ENVMON-MIB::CiscoEnvMonState' tags: - tag: component value: temperature - tag: sensor value: '{#SNMPVALUE}' trigger_prototypes: - uuid: e4844779a080455e9691bdc705227a28 expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor state' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 120dd2434317447d8ee6708d5c1221e3 expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=2' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor state' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is in critical state' expression: 'last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=3 or last(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.status[{#SNMPINDEX}])=4' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 92864c59d4b34a979dc465824c3ef1b2 name: '{#SNMPVALUE}: Temperature' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.9.9.13.1.3.1.3.{#SNMPINDEX}]' key: 'sensor.temp.value[{#SNMPINDEX}]' value_type: FLOAT units: °C description: | MIB: CISCO-ENVMON-MIB Object name: ciscoEnvMonTemperatureValue The current measurement of the test point being instrumented. tags: - tag: component value: temperature - tag: sensor value: '{#SNMPVALUE}' trigger_prototypes: - uuid: 6cecb3ad6e7640cc84b03e3b3943ad07 expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is above critical threshold' event_name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 6f5d1c3f3c804b6ba17486db5e6e8037 expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SNMPVALUE}"}-3' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is above warning threshold' event_name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is above critical threshold' expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"}' recovery_expression: 'max(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SNMPVALUE}"}-3' tags: - tag: scope value: availability - tag: scope value: performance - uuid: ed406cbc4b08446991c610c902574cac expression: 'avg(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'min(/Cisco Catalyst 3750V2-48TS by SNMP/sensor.temp.value[{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}+3' name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is too low' event_name: 'Cisco Catalyst 3750V2-48TS: {#SNMPVALUE}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SNMPVALUE}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: AVERAGE tags: - tag: scope value: availability - tag: scope value: performance tags: - tag: class value: network - tag: target value: cisco - tag: target value: cisco-catalyst - tag: target value: cisco-catalyst-3750v2-48ts macros: - macro: '{$CPU.UTIL.CRIT}' value: '90' description: 'Critical threshold of CPU utilization in %.' - macro: '{$ICMP_LOSS_WARN}' value: '20' description: 'Warning threshold of ICMP packet loss in %.' - macro: '{$ICMP_RESPONSE_TIME_WARN}' value: '0.15' description: 'Threshold of the average ICMP response time in seconds.' - macro: '{$IF.ERRORS.WARN}' value: '2' description: 'Threshold for the warning level of the interface error packet rate.' - macro: '{$IF.UTIL.MAX}' value: '90' description: 'Maximum threshold of interface bandwidth utilization in %. Can be used with the interface name as context.' - macro: '{$IFCONTROL}' value: '1' description: 'Macro for the operational state of the interface for the link down trigger. Can be used with the interface name as context.' - macro: '{$MEMORY.UTIL.MAX}' value: '90' description: 'Threshold for maximum memory utilization in %.' - macro: '{$NET.IF.IFADMINSTATUS.MATCHES}' value: '^.*' description: 'This macro is used to include network interfaces by their administrative status.' - macro: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}' value: ^2$ description: 'Ignore down(2) administrative status' - macro: '{$NET.IF.IFALIAS.MATCHES}' value: '.*' description: 'This macro is used to include network interfaces by their alias.' - macro: '{$NET.IF.IFALIAS.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'This macro is used to exclude network interfaces by their alias.' - macro: '{$NET.IF.IFDESCR.MATCHES}' value: '.*' description: 'This macro is used to include network interfaces by their description.' - macro: '{$NET.IF.IFDESCR.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'This macro is used to exclude network interfaces by their description.' - macro: '{$NET.IF.IFNAME.MATCHES}' value: '^.*$' description: 'This macro is used to include network interfaces by their name.' - macro: '{$NET.IF.IFNAME.NOT_MATCHES}' value: '(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})' description: 'Filter out loopbacks, nulls, docker veth links and docker0 bridge by default' - macro: '{$NET.IF.IFOPERSTATUS.MATCHES}' value: '^.*$' description: 'This macro is used to include network interfaces by their operational status.' - macro: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}' value: ^6$ description: 'Ignore notPresent(6)' - macro: '{$NET.IF.IFTYPE.MATCHES}' value: '.*' description: 'This macro is used to include network interfaces by their type.' - macro: '{$NET.IF.IFTYPE.NOT_MATCHES}' value: CHANGE_IF_NEEDED description: 'This macro is used to exclude network interfaces by their type.' - macro: '{$SNMP.TIMEOUT}' value: 5m description: 'The time interval for the SNMP availability trigger.' - macro: '{$TEMP_CRIT}' value: '60' description: 'Critical threshold of the temperature in °C.' - macro: '{$TEMP_CRIT_LOW}' value: '5' description: 'Critical threshold of the low temperature in °C.' - macro: '{$TEMP_WARN}' value: '50' description: 'Warning threshold of the temperature in °C.' dashboards: - uuid: 3819c2a561ff439fbc521e99f2f38bc2 name: Resources pages: - name: Overview widgets: - type: graphprototype width: '72' height: '5' fields: - type: INTEGER name: columns value: '1' - type: GRAPH_PROTOTYPE name: graphid.0 value: host: 'Cisco Catalyst 3750V2-48TS by SNMP' name: '#{#SNMPINDEX}: CPU utilization' - type: STRING name: reference value: AAAAA - type: graphprototype 'y': '5' width: '72' height: '5' fields: - type: INTEGER name: columns value: '1' - type: GRAPH_PROTOTYPE name: graphid.0 value: host: 'Cisco Catalyst 3750V2-48TS by SNMP' name: '{#SNMPVALUE}: Memory utilization' - type: STRING name: reference value: AAAAB - type: graphprototype 'y': '10' width: '72' height: '10' fields: - type: INTEGER name: columns value: '1' - type: GRAPH_PROTOTYPE name: graphid.0 value: host: 'Cisco Catalyst 3750V2-48TS by SNMP' name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic' - type: STRING name: reference value: AAAAC valuemaps: - uuid: 52875f5c6b1b4bb3987c3baa03860d4d name: 'CISCO-ENVMON-MIB::CiscoEnvMonState' mappings: - value: '1' newvalue: normal - value: '2' newvalue: warning - value: '3' newvalue: critical - value: '4' newvalue: shutdown - value: '5' newvalue: notPresent - value: '6' newvalue: notFunctioning - uuid: 8decf4d7d8744711b5f2ea68b5e73d14 name: 'EtherLike-MIB::dot3StatsDuplexStatus' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: halfDuplex - value: '3' newvalue: fullDuplex - uuid: e8815fad611e47389c987c88a029cece name: 'IF-MIB::ifOperStatus' mappings: - value: '1' newvalue: up - value: '2' newvalue: down - value: '3' newvalue: testing - value: '4' newvalue: unknown - value: '5' newvalue: dormant - value: '6' newvalue: notPresent - value: '7' newvalue: lowerLayerDown - uuid: 93f29c48ad8b4bc7afe036817d946b18 name: 'IF-MIB::ifType' mappings: - value: '1' newvalue: other - value: '2' newvalue: regular1822 - value: '3' newvalue: hdh1822 - value: '4' newvalue: ddnX25 - value: '5' newvalue: rfc877x25 - value: '6' newvalue: ethernetCsmacd - value: '7' newvalue: iso88023Csmacd - value: '8' newvalue: iso88024TokenBus - value: '9' newvalue: iso88025TokenRing - value: '10' newvalue: iso88026Man - value: '11' newvalue: starLan - value: '12' newvalue: proteon10Mbit - value: '13' newvalue: proteon80Mbit - value: '14' newvalue: hyperchannel - value: '15' newvalue: fddi - value: '16' newvalue: lapb - value: '17' newvalue: sdlc - value: '18' newvalue: ds1 - value: '19' newvalue: e1 - value: '20' newvalue: basicISDN - value: '21' newvalue: primaryISDN - value: '22' newvalue: propPointToPointSerial - value: '23' newvalue: ppp - value: '24' newvalue: softwareLoopback - value: '25' newvalue: eon - value: '26' newvalue: ethernet3Mbit - value: '27' newvalue: nsip - value: '28' newvalue: slip - value: '29' newvalue: ultra - value: '30' newvalue: ds3 - value: '31' newvalue: sip - value: '32' newvalue: frameRelay - value: '33' newvalue: rs232 - value: '34' newvalue: para - value: '35' newvalue: arcnet - value: '36' newvalue: arcnetPlus - value: '37' newvalue: atm - value: '38' newvalue: miox25 - value: '39' newvalue: sonet - value: '40' newvalue: x25ple - value: '41' newvalue: iso88022llc - value: '42' newvalue: localTalk - value: '43' newvalue: smdsDxi - value: '44' newvalue: frameRelayService - value: '45' newvalue: v35 - value: '46' newvalue: hssi - value: '47' newvalue: hippi - value: '48' newvalue: modem - value: '49' newvalue: aal5 - value: '50' newvalue: sonetPath - value: '51' newvalue: sonetVT - value: '52' newvalue: smdsIcip - value: '53' newvalue: propVirtual - value: '54' newvalue: propMultiplexor - value: '55' newvalue: ieee80212 - value: '56' newvalue: fibreChannel - value: '57' newvalue: hippiInterface - value: '58' newvalue: frameRelayInterconnect - value: '59' newvalue: aflane8023 - value: '60' newvalue: aflane8025 - value: '61' newvalue: cctEmul - value: '62' newvalue: fastEther - value: '63' newvalue: isdn - value: '64' newvalue: v11 - value: '65' newvalue: v36 - value: '66' newvalue: g703at64k - value: '67' newvalue: g703at2mb - value: '68' newvalue: qllc - value: '69' newvalue: fastEtherFX - value: '70' newvalue: channel - value: '71' newvalue: ieee80211 - value: '72' newvalue: ibm370parChan - value: '73' newvalue: escon - value: '74' newvalue: dlsw - value: '75' newvalue: isdns - value: '76' newvalue: isdnu - value: '77' newvalue: lapd - value: '78' newvalue: ipSwitch - value: '79' newvalue: rsrb - value: '80' newvalue: atmLogical - value: '81' newvalue: ds0 - value: '82' newvalue: ds0Bundle - value: '83' newvalue: bsc - value: '84' newvalue: async - value: '85' newvalue: cnr - value: '86' newvalue: iso88025Dtr - value: '87' newvalue: eplrs - value: '88' newvalue: arap - value: '89' newvalue: propCnls - value: '90' newvalue: hostPad - value: '91' newvalue: termPad - value: '92' newvalue: frameRelayMPI - value: '93' newvalue: x213 - value: '94' newvalue: adsl - value: '95' newvalue: radsl - value: '96' newvalue: sdsl - value: '97' newvalue: vdsl - value: '98' newvalue: iso88025CRFPInt - value: '99' newvalue: myrinet - value: '100' newvalue: voiceEM - value: '101' newvalue: voiceFXO - value: '102' newvalue: voiceFXS - value: '103' newvalue: voiceEncap - value: '104' newvalue: voiceOverIp - value: '105' newvalue: atmDxi - value: '106' newvalue: atmFuni - value: '107' newvalue: atmIma - value: '108' newvalue: pppMultilinkBundle - value: '109' newvalue: ipOverCdlc - value: '110' newvalue: ipOverClaw - value: '111' newvalue: stackToStack - value: '112' newvalue: virtualIpAddress - value: '113' newvalue: mpc - value: '114' newvalue: ipOverAtm - value: '115' newvalue: iso88025Fiber - value: '116' newvalue: tdlc - value: '117' newvalue: gigabitEthernet - value: '118' newvalue: hdlc - value: '119' newvalue: lapf - value: '120' newvalue: v37 - value: '121' newvalue: x25mlp - value: '122' newvalue: x25huntGroup - value: '123' newvalue: trasnpHdlc - value: '124' newvalue: interleave - value: '125' newvalue: fast - value: '126' newvalue: ip - value: '127' newvalue: docsCableMaclayer - value: '128' newvalue: docsCableDownstream - value: '129' newvalue: docsCableUpstream - value: '130' newvalue: a12MppSwitch - value: '131' newvalue: tunnel - value: '132' newvalue: coffee - value: '133' newvalue: ces - value: '134' newvalue: atmSubInterface - value: '135' newvalue: l2vlan - value: '136' newvalue: l3ipvlan - value: '137' newvalue: l3ipxvlan - value: '138' newvalue: digitalPowerline - value: '139' newvalue: mediaMailOverIp - value: '140' newvalue: dtm - value: '141' newvalue: dcn - value: '142' newvalue: ipForward - value: '143' newvalue: msdsl - value: '144' newvalue: ieee1394 - value: '145' newvalue: if-gsn - value: '146' newvalue: dvbRccMacLayer - value: '147' newvalue: dvbRccDownstream - value: '148' newvalue: dvbRccUpstream - value: '149' newvalue: atmVirtual - value: '150' newvalue: mplsTunnel - value: '151' newvalue: srp - value: '152' newvalue: voiceOverAtm - value: '153' newvalue: voiceOverFrameRelay - value: '154' newvalue: idsl - value: '155' newvalue: compositeLink - value: '156' newvalue: ss7SigLink - value: '157' newvalue: propWirelessP2P - value: '158' newvalue: frForward - value: '159' newvalue: rfc1483 - value: '160' newvalue: usb - value: '161' newvalue: ieee8023adLag - value: '162' newvalue: bgppolicyaccounting - value: '163' newvalue: frf16MfrBundle - value: '164' newvalue: h323Gatekeeper - value: '165' newvalue: h323Proxy - value: '166' newvalue: mpls - value: '167' newvalue: mfSigLink - value: '168' newvalue: hdsl2 - value: '169' newvalue: shdsl - value: '170' newvalue: ds1FDL - value: '171' newvalue: pos - value: '172' newvalue: dvbAsiIn - value: '173' newvalue: dvbAsiOut - value: '174' newvalue: plc - value: '175' newvalue: nfas - value: '176' newvalue: tr008 - value: '177' newvalue: gr303RDT - value: '178' newvalue: gr303IDT - value: '179' newvalue: isup - value: '180' newvalue: propDocsWirelessMaclayer - value: '181' newvalue: propDocsWirelessDownstream - value: '182' newvalue: propDocsWirelessUpstream - value: '183' newvalue: hiperlan2 - value: '184' newvalue: propBWAp2Mp - value: '185' newvalue: sonetOverheadChannel - value: '186' newvalue: digitalWrapperOverheadChannel - value: '187' newvalue: aal2 - value: '188' newvalue: radioMAC - value: '189' newvalue: atmRadio - value: '190' newvalue: imt - value: '191' newvalue: mvl - value: '192' newvalue: reachDSL - value: '193' newvalue: frDlciEndPt - value: '194' newvalue: atmVciEndPt - value: '195' newvalue: opticalChannel - value: '196' newvalue: opticalTransport - value: '197' newvalue: propAtm - value: '198' newvalue: voiceOverCable - value: '199' newvalue: infiniband - value: '200' newvalue: teLink - value: '201' newvalue: q2931 - value: '202' newvalue: virtualTg - value: '203' newvalue: sipTg - value: '204' newvalue: sipSig - value: '205' newvalue: docsCableUpstreamChannel - value: '206' newvalue: econet - value: '207' newvalue: pon155 - value: '208' newvalue: pon622 - value: '209' newvalue: bridge - value: '210' newvalue: linegroup - value: '211' newvalue: voiceEMFGD - value: '212' newvalue: voiceFGDEANA - value: '213' newvalue: voiceDID - value: '214' newvalue: mpegTransport - value: '215' newvalue: sixToFour - value: '216' newvalue: gtp - value: '217' newvalue: pdnEtherLoop1 - value: '218' newvalue: pdnEtherLoop2 - value: '219' newvalue: opticalChannelGroup - value: '220' newvalue: homepna - value: '221' newvalue: gfp - value: '222' newvalue: ciscoISLvlan - value: '223' newvalue: actelisMetaLOOP - value: '224' newvalue: fcipLink - value: '225' newvalue: rpr - value: '226' newvalue: qam - value: '227' newvalue: lmp - value: '228' newvalue: cblVectaStar - value: '229' newvalue: docsCableMCmtsDownstream - value: '230' newvalue: adsl2 - value: '231' newvalue: macSecControlledIF - value: '232' newvalue: macSecUncontrolledIF - value: '233' newvalue: aviciOpticalEther - value: '234' newvalue: atmbond - value: '235' newvalue: voiceFGDOS - value: '236' newvalue: mocaVersion1 - value: '237' newvalue: ieee80216WMAN - value: '238' newvalue: adsl2plus - value: '239' newvalue: dvbRcsMacLayer - value: '240' newvalue: dvbTdm - value: '241' newvalue: dvbRcsTdma - value: '242' newvalue: x86Laps - value: '243' newvalue: wwanPP - value: '244' newvalue: wwanPP2 - value: '245' newvalue: voiceEBS - value: '246' newvalue: ifPwType - value: '247' newvalue: ilan - value: '248' newvalue: pip - value: '249' newvalue: aluELP - value: '250' newvalue: gpon - value: '251' newvalue: vdsl2 - value: '252' newvalue: capwapDot11Profile - value: '253' newvalue: capwapDot11Bss - value: '254' newvalue: capwapWtpVirtualRadio - value: '255' newvalue: bits - value: '256' newvalue: docsCableUpstreamRfPort - value: '257' newvalue: cableDownstreamRfPort - value: '258' newvalue: vmwareVirtualNic - value: '259' newvalue: ieee802154 - value: '260' newvalue: otnOdu - value: '261' newvalue: otnOtu - value: '262' newvalue: ifVfiType - value: '263' newvalue: g9981 - value: '264' newvalue: g9982 - value: '265' newvalue: g9983 - value: '266' newvalue: aluEpon - value: '267' newvalue: aluEponOnu - value: '268' newvalue: aluEponPhysicalUni - value: '269' newvalue: aluEponLogicalLink - value: '270' newvalue: aluGponOnu - value: '271' newvalue: aluGponPhysicalUni - value: '272' newvalue: vmwareNicTeam - value: '277' newvalue: docsOfdmDownstream - value: '278' newvalue: docsOfdmaUpstream - value: '279' newvalue: gfast - value: '280' newvalue: sdci - value: '281' newvalue: xboxWireless - value: '282' newvalue: fastdsl - value: '283' newvalue: docsCableScte55d1FwdOob - value: '284' newvalue: docsCableScte55d1RetOob - value: '285' newvalue: docsCableScte55d2DsOob - value: '286' newvalue: docsCableScte55d2UsOob - value: '287' newvalue: docsCableNdf - value: '288' newvalue: docsCableNdr - value: '289' newvalue: ptm - value: '290' newvalue: ghn - uuid: ee7cb62782d44458abc9f7cca816dca8 name: 'Service state' mappings: - value: '0' newvalue: Down - value: '1' newvalue: Up - uuid: 6273854a740e41718cd1354f227cf4db name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown triggers: - uuid: 2f1841fb315041a2a437886dc6c23814 expression: '(last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)>0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)<10m) or (last(/Cisco Catalyst 3750V2-48TS by SNMP/system.hw.uptime)=0 and last(/Cisco Catalyst 3750V2-48TS by SNMP/system.net.uptime)<10m)' name: 'Cisco Catalyst 3750V2-48TS: Host has been restarted' event_name: 'Cisco Catalyst 3750V2-48TS: {HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes.' manual_close: 'YES' tags: - tag: scope value: notice