zabbix_export: version: '7.0' template_groups: - uuid: 36bff6c29af64692839d077febfc7079 name: 'Templates/Network devices' templates: - uuid: 230fa9f7c1774821bbe6cdcbbba5cbc6 template: 'Morningstar TriStar PWM by SNMP' name: 'Morningstar TriStar PWM by SNMP' description: | MIBs used: TRISTAR Generated by official Zabbix template tool "Templator" vendor: name: Zabbix version: 7.0-2 groups: - name: 'Templates/Network devices' items: - uuid: b76ef47ada0c43cfb50c6a80c8ca55e5 name: 'Battery: Battery Voltage discovery' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.30.0]' key: 'battery.voltage.discovery[batteryVoltage.0]' delay: 15m history: '0' value_type: FLOAT units: V description: | MIB: TRISTAR Description:Battery voltage Scaling Factor:0.002950042724609375 Units:V Range:[0.0, 80.0] Modbus address:0x0008 preprocessing: - type: MULTIPLIER parameters: - '0.002950042725' tags: - tag: component value: battery - tag: component value: discovery - tag: component value: raw - uuid: 0c57da022cf8497e88f788cee1b3a0a6 name: 'Status: Control Mode' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.45.0]' key: 'control.mode[controlMode.0]' value_type: FLOAT description: | MIB: TRISTAR Description:Control Mode Modbus address:0x001A 0: charge 1: loadControl 2: diversion 3: lighting valuemap: name: 'TriStar PWM control mode' tags: - tag: component value: status - uuid: 25a576060f6948e59a855462b04c7276 name: 'Counter: Amp-hours' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.39.0]' key: 'counter.charge_amp_hours[ahResettable.0]' value_type: FLOAT units: Ah description: | MIB: TRISTAR Description:Ah (Resettable) Scaling Factor:0.1 Units:Ah Range:[0.0, 50000.0] Modbus addresses:H=0x0011 L=0x0012 preprocessing: - type: MULTIPLIER parameters: - '0.1' tags: - tag: component value: counter - uuid: d2351af0b6244044949eba67a7f7b39c name: 'Counter: KW-hours' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.49.0]' key: 'counter.charge_kw_hours[kilowattHours.0]' value_type: FLOAT units: '!kWh' description: | MIB: TRISTAR Description:Kilowatt Hours Scaling Factor:1.0 Units:kWh Range:[0.0, 5000.0] Modbus address:0x001E preprocessing: - type: MULTIPLIER parameters: - '0.001' - type: REGEX parameters: - '^(\d+)(\.\d{1,2})?' - \1\2 tags: - tag: component value: counter - uuid: 03c3397ac32b47499002b13e0735ec9b name: 'Status: Alarms' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.42.0]' key: 'status.alarms[alarms.0]' history: 1h value_type: TEXT trends: '0' description: | MIB: TRISTAR Description:Alarms Modbus addresses:H=0x001D L=0x0017 preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h - type: JAVASCRIPT parameters: - | var FIELDS = [ 'rtsOpen', 'rtsShorted', 'rtsDisconnected', 'heatsinkTempSensorOpen', 'heatsinkTempSensorShorted', 'tristarHot', 'currentLimit', 'currentOffset', 'batterySense', 'batterySenseDisconnected', 'uncalibrated', 'rtsMiswire', 'highVoltageDisconnect', 'diversionLoadNearMax', 'systemMiswire', 'mosfetSOpen', 'p12VoltageReferenceOff', 'loadDisconnectState', ]; var flags = parseInt(value.replace(/\x20/g, ''), 16), result = []; for (var i = 0, f = 1 << 31 >>> 0, l = FIELDS.length; i < l; i++, f >>>= 1) { if (flags & f) { result.push(FIELDS[i]); } } return result.length ? result.join('\n') : 'No alarms'; tags: - tag: component value: status triggers: - uuid: 121d47c6bbdd45bca261df2e01ea41c6 expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","batterySense")=2' name: 'Morningstar TriStar PWM: Status: Device has "batterySense" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: fd2d9290144143d39bb5a3cf0a2d261f expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","batterySenseDisconnected")=2' name: 'Morningstar TriStar PWM: Status: Device has "batterySenseDisconnected" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 83d5b8d52acd4e21ac6d3a9cf05dcd04 expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","currentLimit")=2' name: 'Morningstar TriStar PWM: Status: Device has "currentLimit" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: d9529a4372d848038e6ee561d62e9f22 expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","currentOffset")=2' name: 'Morningstar TriStar PWM: Status: Device has "currentOffset" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 5f3983acc1cc417e860c1305b11c15ea expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","diversionLoadNearMax")=2' name: 'Morningstar TriStar PWM: Status: Device has "diversionLoadNearMax" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 878e04df7e7b416bb0d2213b5dbb80e6 expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorOpen")=2' name: 'Morningstar TriStar PWM: Status: Device has "heatsinkTempSensorOpen" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: c642ed9496ce4322809c7142d32929a5 expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","heatsinkTempSensorShorted")=2' name: 'Morningstar TriStar PWM: Status: Device has "heatsinkTempSensorShorted" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 532421fe17bf4732a01a6990e34e649a expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","highVoltageDisconnect")=2' name: 'Morningstar TriStar PWM: Status: Device has "highVoltageDisconnect" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: ae90e8034baf4b21906d56d18bfa4da8 expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","loadDisconnectState")=2' name: 'Morningstar TriStar PWM: Status: Device has "loadDisconnectState" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 8d8b721c6dee40499b29bee44b21589a expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","mosfetSOpen")=2' name: 'Morningstar TriStar PWM: Status: Device has "mosfetSOpen" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 8cda8e5773de4583b9baa6a6e542e32c expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","p12VoltageReferenceOff")=2' name: 'Morningstar TriStar PWM: Status: Device has "p12VoltageReferenceOff" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 1b6192b8ca364c229b35ba6de89ad56b expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","rtsDisconnected")=2' name: 'Morningstar TriStar PWM: Status: Device has "rtsDisconnected" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 176de77a142d45a3ac39ea42989e209c expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","rtsMiswire")=2' name: 'Morningstar TriStar PWM: Status: Device has "rtsMiswire" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: f63029eabc8e498ea7e6336d312ac169 expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","rtsShorted")=2' name: 'Morningstar TriStar PWM: Status: Device has "rtsShorted" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 480b69c1febf45a2971788c2f967c45d expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","systemMiswire")=2' name: 'Morningstar TriStar PWM: Status: Device has "systemMiswire" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 4a287e4086c4458aaa3dc48bbb8ee219 expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","tristarHot")=2' name: 'Morningstar TriStar PWM: Status: Device has "tristarHot" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: de665482d2574730a3a839948dd730ea expression: 'count(/Morningstar TriStar PWM by SNMP/status.alarms[alarms.0],#3,"like","uncalibrated")=2' name: 'Morningstar TriStar PWM: Status: Device has "uncalibrated" alarm flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING tags: - tag: scope value: notice - uuid: 9d0f4444f98c4ec082d35559e8fe9ac5 name: 'Status: Faults' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.43.0]' key: 'status.faults[faults.0]' history: 1h value_type: TEXT trends: '0' description: | MIB: TRISTAR Description:Battery voltage Scaling Factor:0.002950042724609375 Units:V Range:[0.0, 80.0] Modbus address:0x0008 preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h - type: JAVASCRIPT parameters: - | var FIELDS = [ 'externalShort', 'overcurrent', 'mosfetSShorted', 'softwareFault', 'highVoltageDisconnect', 'tristarHot', 'dipSwitchChange', 'customSettingsEdit', 'reset', 'systemMiswire', 'rtsShorted', 'rtsDisconnected', ]; var flags = parseInt(value.replace(/\x20/g, ''), 16), result = []; for (var i = 0, f = 1 << 31 >>> 0, l = FIELDS.length; i < l; i++, f >>>= 1) { if (flags & f) { result.push(FIELDS[i]); } } return result.length ? result.join('\n') : 'No faults'; tags: - tag: component value: status triggers: - uuid: 514b041aebdd4ddb8ab2d1222c0ef295 expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","customSettingsEdit")=2' name: 'Morningstar TriStar PWM: Status: Device has "customSettingsEdit" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 1a40ce8b87f04ab1b4f30387e9ce2d9d expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","dipSwitchChange")=2' name: 'Morningstar TriStar PWM: Status: Device has "dipSwitchChange" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 49b120c3933c43b1b7f5c77f7b359997 expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","externalShort")=2' name: 'Morningstar TriStar PWM: Status: Device has "externalShort" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: f063b9f717c44ab988db7ac95bfca68f expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","highVoltageDisconnect")=2' name: 'Morningstar TriStar PWM: Status: Device has "highVoltageDisconnect" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 468716d748f1470cb764ce1af922164d expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","mosfetSShorted")=2' name: 'Morningstar TriStar PWM: Status: Device has "mosfetSShorted" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: b6f65dfca421490eafff48991cdf1e3b expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","overcurrent")=2' name: 'Morningstar TriStar PWM: Status: Device has "overcurrent" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 73561a5765694633b1dc0ef1b1f60fd4 expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","reset")=2' name: 'Morningstar TriStar PWM: Status: Device has "reset" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: d14c7d928f57448390c2b4c588a28c65 expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","rtsDisconnected")=2' name: 'Morningstar TriStar PWM: Status: Device has "rtsDisconnected" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: d94067598c234968b4929404067eff86 expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","rtsShorted")=2' name: 'Morningstar TriStar PWM: Status: Device has "rtsShorted" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 886b18bee7cd4f8eb454973e2d2ae59f expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","softwareFault")=2' name: 'Morningstar TriStar PWM: Status: Device has "softwareFault" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 2e520cdafaaa4eefad5ebea71819c3a6 expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","systemMiswire")=2' name: 'Morningstar TriStar PWM: Status: Device has "systemMiswire" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 041be44e639d4d1eadb15230a678e278 expression: 'count(/Morningstar TriStar PWM by SNMP/status.faults[faults.0],#3,"like","tristarHot")=2' name: 'Morningstar TriStar PWM: Status: Device has "tristarHot" faults flag' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 6903297e21e14aa8b5eed4eb0f7e1e01 name: 'Status: Uptime (hardware)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]' key: status.hw.uptime units: uptime description: 'The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.' preprocessing: - type: CHECK_NOT_SUPPORTED parameters: - '-1' error_handler: CUSTOM_VALUE error_handler_params: '0' - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: status - uuid: 642eec19ba5d450186590e9f5bba36db name: 'Status: Uptime (network)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.3.0]' key: status.net.uptime units: uptime description: 'The time (in hundredths of a second) since the network management portion of the system was last re-initialized.' preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: status triggers: - uuid: 64aa2a79fe854def8e179a4d27790417 expression: 'nodata(/Morningstar TriStar PWM by SNMP/status.net.uptime,5m)=1' name: 'Morningstar TriStar PWM: Status: Failed to fetch data' event_name: 'Morningstar TriStar PWM: Status: Failed to fetch data (or no data for 5m)' priority: WARNING description: 'Zabbix has not received data for items for the last 5 minutes.' manual_close: 'YES' tags: - tag: scope value: availability - uuid: bc729e23973b4d9d97d694d884431e0b name: 'Temperature: Battery' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.37.0]' key: 'temp.battery[batteryTemperature.0]' value_type: FLOAT units: C description: | MIB: TRISTAR Description:Battery Temperature Scaling Factor:1.0 Units:deg C Range:[-40, 120] Modbus address:0x000F tags: - tag: component value: temperature triggers: - uuid: e759b90e2bf44bbb8e5efe5b9e458e40 expression: 'min(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}' name: 'Morningstar TriStar PWM: Temperature: Critically high battery temperature' event_name: 'Morningstar TriStar PWM: Temperature: Critically high battery temperature (over {$BATTERY.TEMP.MAX.CRIT}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: e57f335f657d45768509f139d31dcdae expression: 'max(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}' name: 'Morningstar TriStar PWM: Temperature: Critically low battery temperature' event_name: 'Morningstar TriStar PWM: Temperature: Critically low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 7d1444dba9334e91ad425a6f2ff9fef9 expression: 'min(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.WARN}' name: 'Morningstar TriStar PWM: Temperature: High battery temperature' event_name: 'Morningstar TriStar PWM: Temperature: High battery temperature (over {$BATTERY.TEMP.MAX.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Morningstar TriStar PWM: Temperature: Critically high battery temperature' expression: 'min(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)>{$BATTERY.TEMP.MAX.CRIT}' tags: - tag: scope value: notice - uuid: 14fe4a22b28c4d08a24da51a54e36e81 expression: 'max(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.WARN}' name: 'Morningstar TriStar PWM: Temperature: Low battery temperature' event_name: 'Morningstar TriStar PWM: Temperature: Low battery temperature (below {$BATTERY.TEMP.MIN.WARN}C for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Morningstar TriStar PWM: Temperature: Critically low battery temperature' expression: 'max(/Morningstar TriStar PWM by SNMP/temp.battery[batteryTemperature.0],5m)<{$BATTERY.TEMP.MIN.CRIT}' tags: - tag: scope value: notice - uuid: a9a009058e99419dbb6cbef5b7797388 name: 'Temperature: Heatsink' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.36.0]' key: 'temp.heatsink[heatsinkTemperature.0]' value_type: FLOAT units: C description: | MIB: TRISTAR Description:Heatsink Temperature Scaling Factor:1.0 Units:deg C Range:[-40, 120] Modbus address:0x000E tags: - tag: component value: temperature discovery_rules: - uuid: 0e06c296579f4b6aa40d69ebb62742b4 name: 'Battery voltage discovery' type: DEPENDENT key: battery.voltage.discovery delay: '0' description: 'Discovery for battery voltage triggers' item_prototypes: - uuid: e1960caed8c44606bb684e28cdfac3c7 name: 'Battery: Voltage{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.30.0]' key: 'battery.voltage[batteryVoltage.0{#SINGLETON}]' value_type: FLOAT units: V description: | MIB: TRISTAR Description:Battery voltage Scaling Factor:0.002950042724609375 Units:V Range:[0.0, 80.0] Modbus address:0x0008 preprocessing: - type: MULTIPLIER parameters: - '0.002950042725' - type: REGEX parameters: - '^(\d+)(\.\d{1,2})?' - \1\2 tags: - tag: component value: battery trigger_prototypes: - uuid: 156ec13d673b4a8aa02a87b1794cb722 expression: 'min(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}' name: 'Morningstar TriStar PWM: Battery: Critically high battery voltage' event_name: 'Morningstar TriStar PWM: Battery: Critically high battery voltage (over {#VOLTAGE.MAX.CRIT}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: capacity - uuid: 5e4400321f4f45b39397c68a4ba54d8e expression: 'max(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}' name: 'Morningstar TriStar PWM: Battery: Critically low battery voltage' event_name: 'Morningstar TriStar PWM: Battery: Critically low battery voltage (below {#VOLTAGE.MIN.CRIT}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: capacity - uuid: fa6502a4a0214f7f933e982182d21d6b expression: 'min(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.WARN}' name: 'Morningstar TriStar PWM: Battery: High battery voltage' event_name: 'Morningstar TriStar PWM: Battery: High battery voltage (over {#VOLTAGE.MAX.WARN}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Morningstar TriStar PWM: Battery: Critically high battery voltage' expression: 'min(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)>{#VOLTAGE.MAX.CRIT}' tags: - tag: scope value: capacity - uuid: a5275748f4c742ea8ab9efd266901e95 expression: 'max(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.WARN}' name: 'Morningstar TriStar PWM: Battery: Low battery voltage' event_name: 'Morningstar TriStar PWM: Battery: Low battery voltage (below {#VOLTAGE.MIN.WARN}V for 5m)' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Morningstar TriStar PWM: Battery: Critically low battery voltage' expression: 'max(/Morningstar TriStar PWM by SNMP/battery.voltage[batteryVoltage.0{#SINGLETON}],5m)<{#VOLTAGE.MIN.CRIT}' tags: - tag: scope value: capacity graph_prototypes: - uuid: bbdea967f4f34a299dd8d9bee43f2841 name: 'Battery: Voltage{#SINGLETON}' graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Morningstar TriStar PWM by SNMP' key: 'battery.voltage[batteryVoltage.0{#SINGLETON}]' master_item: key: 'battery.voltage.discovery[batteryVoltage.0]' preprocessing: - type: JAVASCRIPT parameters: - | var v_range = [ [[0, 18], [12, 15, 11.5, 15.5]], [[18, 36], [24, 30, 23, 31]], [[36, 99], [48, 60, 46, 62]], ], result = []; for (var idx in v_range) { if (v_range[idx][0][0] < value && value <= v_range[idx][0][1]) { result = [{ '{#VOLTAGE.MIN.WARN}': parseInt({$VOLTAGE.MIN.WARN}) || v_range[idx][1][0], '{#VOLTAGE.MAX.WARN}': parseInt({$VOLTAGE.MAX.WARN}) || v_range[idx][1][1], '{#VOLTAGE.MIN.CRIT}': parseInt({$VOLTAGE.MIN.CRIT}) || v_range[idx][1][2], '{#VOLTAGE.MAX.CRIT}': parseInt({$VOLTAGE.MAX.CRIT}) || v_range[idx][1][3], '{#SINGLETON}': '' }]; break; } } return JSON.stringify(result); - uuid: 58a500192e61490f97f33d5b5f6e972f name: 'Charge mode discovery' type: DEPENDENT key: controlmode.charge.discovery delay: '0' lifetime: 1h description: 'Discovery for device in charge mode' item_prototypes: - uuid: f5d120bee1964f10853819d576ddb930 name: 'Array: Voltage{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.32.0]' key: 'array.voltage[arrayloadVoltage.0{#SINGLETON}]' value_type: FLOAT units: V description: | MIB: TRISTAR Description:Array/Load Voltage Scaling Factor:0.00424652099609375 Units:V Range:[0, 80] Modbus address:0x000A preprocessing: - type: MULTIPLIER parameters: - '0.004246520996' - type: REGEX parameters: - '^(\d+)(\.\d{1,2})?' - \1\2 tags: - tag: component value: array - uuid: b5d74de2e96440a5a00a4a4dffffbb26 name: 'Battery: Charge Current{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.33.0]' key: 'charge.current[chargeCurrent.0{#SINGLETON}]' value_type: FLOAT units: A description: | MIB: TRISTAR Description:Charge Current Scaling Factor:0.002034515380859375 Units:A Range:[0, 60] Modbus address:0x000B preprocessing: - type: MULTIPLIER parameters: - '0.002034515381' - type: REGEX parameters: - '^(\d+)(\.\d{1,2})?' - \1\2 tags: - tag: component value: battery graph_prototypes: - uuid: 9886a05be4a74a82a208e3a5950f022d name: 'Array: Voltage{#SINGLETON}' graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Morningstar TriStar PWM by SNMP' key: 'array.voltage[arrayloadVoltage.0{#SINGLETON}]' - uuid: cd64c57669314d2e9526fbc580034c81 name: 'Battery: Charge Current{#SINGLETON}' graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Morningstar TriStar PWM by SNMP' key: 'charge.current[chargeCurrent.0{#SINGLETON}]' master_item: key: 'control.mode[controlMode.0]' preprocessing: - type: JAVASCRIPT parameters: - 'return JSON.stringify(parseInt(value) === 0 ? [{ ''{#SINGLETON}'': '''' }] : []);' - uuid: 02fbfa1dd59a4b9c87bb81da81312f54 name: 'Charge + Diversion mode discovery' type: DEPENDENT key: controlmode.charge_diversion.discovery delay: '0' lifetime: 1h description: 'Discovery for device in charge and diversion modes' item_prototypes: - uuid: e08b526bbb484753a11c99011d31d945 name: 'Battery: Charge State{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.46.0]' key: 'charge.state[controlState.0{#SINGLETON}]' value_type: FLOAT description: | MIB: TRISTAR Description:Control State Modbus address:0x001B valuemap: name: 'TriStar PWM charge state' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: battery trigger_prototypes: - uuid: da21473ce79c42269cc24d3e470b7d07 expression: 'last(/Morningstar TriStar PWM by SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.CRIT}' name: 'Morningstar TriStar PWM: Battery: Device charge in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: 79a592050bc64c018cfa5c7b779fba02 expression: 'last(/Morningstar TriStar PWM by SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.WARN}' name: 'Morningstar TriStar PWM: Battery: Device charge in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Morningstar TriStar PWM: Battery: Device charge in critical state' expression: 'last(/Morningstar TriStar PWM by SNMP/charge.state[controlState.0{#SINGLETON}])={$CHARGE.STATE.CRIT}' tags: - tag: scope value: notice - uuid: edd7d01d2523481293f3ac9e8f3c0a00 name: 'Battery: Target Voltage{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.38.0]' key: 'target.voltage[targetVoltage.0{#SINGLETON}]' value_type: FLOAT units: V description: | MIB: TRISTAR Description:Target Regulation Voltage Scaling Factor:0.002950042724609375 Units:V Range:[0.0, 80.0] Modbus address:0x0010 preprocessing: - type: MULTIPLIER parameters: - '0.002950042725' - type: REGEX parameters: - '^(\d+)(\.\d{1,2})?' - \1\2 tags: - tag: component value: battery master_item: key: 'control.mode[controlMode.0]' preprocessing: - type: JAVASCRIPT parameters: - | var mode = parseInt(value); return JSON.stringify((mode === 0 || mode === 2) ? [{ '{#SINGLETON}': '' }] : []); - uuid: 8c345c0134fe4d90af83292e557d7309 name: 'Diversion mode discovery' type: DEPENDENT key: controlmode.diversion.discovery delay: '0' lifetime: 1h description: 'Discovery for device in diversion mode' item_prototypes: - uuid: 33e6b5a75c1e454cb7b7bc0b1426d1b9 name: 'Load: PWM Duty Cycle{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.48.0]' key: 'diversion.pwm_duty_cycle[pwmDutyCycle.0{#SINGLETON}]' value_type: FLOAT description: | MIB: TRISTAR Description:PWM Duty Cycle Scaling Factor:0.392156862745098 Units:% Range:[0.0, 100.0] Modbus address:0x001C preprocessing: - type: MULTIPLIER parameters: - '0.3921568627' - type: REGEX parameters: - '^(\d+)(\.\d{1,2})?' - \1\2 tags: - tag: component value: load master_item: key: 'control.mode[controlMode.0]' preprocessing: - type: JAVASCRIPT parameters: - 'return JSON.stringify(parseInt(value) === 2 ? [{ ''{#SINGLETON}'': '''' }] : []);' - uuid: 54bfd7f730e64af89f937e9b1b6e4d79 name: 'Load mode discovery' type: DEPENDENT key: controlmode.load.discovery delay: '0' lifetime: 1h description: 'Discovery for device in load mode' item_prototypes: - uuid: 6d42918b9c244f88a23ab1daf2a929ce name: 'Load: State{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.47.0]' key: 'load.state[loadState.0{#SINGLETON}]' value_type: FLOAT description: | MIB: TRISTAR Description:Load State Modbus address:0x001B 0: Start 1: Normal 2: LvdWarning 3: Lvd 4: Fault 5: Disconnect 6: LvdWarning1 7: OverrideLvd 8: Equalize valuemap: name: 'TriStar PWM load state' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: load trigger_prototypes: - uuid: 9035e0a92d384a3c844b8a4d4ebd1eb9 expression: 'last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"fault"}' name: 'Morningstar TriStar PWM: Load: Device load in critical state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH tags: - tag: scope value: notice - uuid: a2d13f97c4bd46bfab8e74a2f2a7df2e expression: 'last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.WARN:"lvdWarning"} or last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.WARN:"override"}' name: 'Morningstar TriStar PWM: Load: Device load in warning state' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING dependencies: - name: 'Morningstar TriStar PWM: Load: Device load in critical state' expression: 'last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"lvd"} or last(/Morningstar TriStar PWM by SNMP/load.state[loadState.0{#SINGLETON}])={$LOAD.STATE.CRIT:"fault"}' tags: - tag: scope value: notice master_item: key: 'control.mode[controlMode.0]' preprocessing: - type: JAVASCRIPT parameters: - 'return JSON.stringify(parseInt(value) === 1 ? [{ ''{#SINGLETON}'': '''' }] : []);' - uuid: 2e2e01f5c1db4224a97162382c77832c name: 'Load + Diversion mode discovery' type: DEPENDENT key: controlmode.load_diversion.discovery delay: '0' lifetime: 1h description: 'Discovery for device in load and diversion modes' item_prototypes: - uuid: b6db019203cc41ca94dcbe54382fdaad name: 'Load: Current{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.34.0]' key: 'load.current[loadCurrent.0{#SINGLETON}]' value_type: FLOAT units: A description: | MIB: TRISTAR Description:Load Current Scaling Factor:0.00966400146484375 Units:A Range:[0, 60] Modbus address:0x000C preprocessing: - type: MULTIPLIER parameters: - '0.009664001465' - type: REGEX parameters: - '^(\d+)(\.\d{1,2})?' - \1\2 tags: - tag: component value: load - uuid: f87ddb7d31d748c8917030ede731f37a name: 'Load: Voltage{#SINGLETON}' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.33333.8.32.0]' key: 'load.voltage[arrayloadVoltage.0{#SINGLETON}]' value_type: FLOAT units: V description: | MIB: TRISTAR Description:Array/Load Voltage Scaling Factor:0.00424652099609375 Units:V Range:[0, 80] Modbus address:0x000A preprocessing: - type: MULTIPLIER parameters: - '0.004246520996' - type: REGEX parameters: - '^(\d+)(\.\d{1,2})?' - \1\2 tags: - tag: component value: load graph_prototypes: - uuid: 91ee10b435144218ab3dfac8f6bf7bdd name: 'Load: Current{#SINGLETON}' graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Morningstar TriStar PWM by SNMP' key: 'load.current[loadCurrent.0{#SINGLETON}]' - uuid: b4b595193e0c40a2b390f7ce6eefba4a name: 'Load: Voltage{#SINGLETON}' graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Morningstar TriStar PWM by SNMP' key: 'load.voltage[arrayloadVoltage.0{#SINGLETON}]' master_item: key: 'control.mode[controlMode.0]' preprocessing: - type: JAVASCRIPT parameters: - | var mode = parseInt(value); return JSON.stringify((mode === 1 || mode === 2) ? [{ '{#SINGLETON}': '' }] : []); tags: - tag: class value: power - tag: target value: morningstar macros: - macro: '{$BATTERY.TEMP.MAX.CRIT}' value: '60' description: 'Battery high temperature critical value' - macro: '{$BATTERY.TEMP.MAX.WARN}' value: '45' description: 'Battery high temperature warning value' - macro: '{$BATTERY.TEMP.MIN.CRIT}' value: '-20' description: 'Battery low temperature critical value' - macro: '{$BATTERY.TEMP.MIN.WARN}' value: '0' description: 'Battery low temperature warning value' - macro: '{$CHARGE.STATE.CRIT}' value: '4' description: fault - macro: '{$CHARGE.STATE.WARN}' value: '2' description: disconnect - macro: '{$LOAD.STATE.CRIT:"fault"}' value: '4' description: fault - macro: '{$LOAD.STATE.CRIT:"lvd"}' value: '3' description: lvd - macro: '{$LOAD.STATE.WARN:"disconnect"}' value: '5' description: disconnect - macro: '{$LOAD.STATE.WARN:"lvdWarning"}' value: '2' description: lvdWarning - macro: '{$LOAD.STATE.WARN:"override"}' value: '7' description: override - macro: '{$VOLTAGE.MAX.CRIT}' - macro: '{$VOLTAGE.MAX.WARN}' - macro: '{$VOLTAGE.MIN.CRIT}' - macro: '{$VOLTAGE.MIN.WARN}' dashboards: - uuid: 7b5209a7cf3f407fb825712f3558bf03 name: 'Morningstar TriStar PWM: Overview' pages: - widgets: - type: graph width: '72' height: '4' fields: - type: GRAPH name: graphid.0 value: host: 'Morningstar TriStar PWM by SNMP' name: 'Temperature: Battery/Heatsink' - type: STRING name: reference value: AAAAA valuemaps: - uuid: 4985c4742d5844e7bc0aee5aeeacc436 name: 'TriStar PWM charge state' mappings: - value: '0' newvalue: Start - value: '1' newvalue: NightCheck - value: '2' newvalue: Disconnect - value: '3' newvalue: Night - value: '4' newvalue: Fault - value: '5' newvalue: Bulk - value: '6' newvalue: Absorption - value: '7' newvalue: Float - value: '8' newvalue: Equalize - uuid: 252c3fb63cc34bb1a36ae6e9cbe5880c name: 'TriStar PWM control mode' mappings: - value: '0' newvalue: Charge - value: '1' newvalue: LoadControl - value: '2' newvalue: Diversion - value: '3' newvalue: Lighting - uuid: 735e1a0d990a4c449e59eeb402f3b40e name: 'TriStar PWM load state' mappings: - value: '0' newvalue: Start - value: '1' newvalue: Normal - value: '2' newvalue: LvdWarning - value: '3' newvalue: Lvd - value: '4' newvalue: Fault - value: '5' newvalue: Disconnect - value: '6' newvalue: LvdWarning1 - value: '7' newvalue: OverrideLvd - value: '8' newvalue: Equalize triggers: - uuid: f0549419f015448497cd7d15a2bf96fa expression: '(last(/Morningstar TriStar PWM by SNMP/status.hw.uptime)>0 and last(/Morningstar TriStar PWM by SNMP/status.hw.uptime)<10m) or (last(/Morningstar TriStar PWM by SNMP/status.hw.uptime)=0 and last(/Morningstar TriStar PWM by SNMP/status.net.uptime)<10m)' name: 'Morningstar TriStar PWM: Status: Device has been restarted' event_name: 'Morningstar TriStar PWM: Status: Device has been restarted (uptime < 10m)' priority: INFO description: 'Uptime is less than 10 minutes.' manual_close: 'YES' tags: - tag: scope value: notice graphs: - uuid: ce3aa40eac5f4ee199ed214752304e19 name: 'Temperature: Battery/Heatsink' graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Morningstar TriStar PWM by SNMP' key: 'temp.battery[batteryTemperature.0]' - sortorder: '1' drawtype: GRADIENT_LINE color: F63100 item: host: 'Morningstar TriStar PWM by SNMP' key: 'temp.heatsink[heatsinkTemperature.0]'