zabbix_export: version: '7.0' template_groups: - uuid: 36bff6c29af64692839d077febfc7079 name: 'Templates/Network devices' templates: - uuid: de96d02bd5f242bfa31308ae2131d03f template: 'Brocade FC by SNMP' name: 'Brocade FC by SNMP' description: | Template Net Brocade FC MIBs used: HOST-RESOURCES-MIB SNMPv2-MIB SW-MIB IF-MIB Known Issues: Description: no IF-MIB::ifAlias is available Version: v6.3.1c, v7.0.0c, v7.4.1c Device: all Generated by official Zabbix template tool "Templator" vendor: name: Zabbix version: 7.0-2 groups: - name: 'Templates/Network devices' items: - uuid: 79adbe7d5d8f4dd6a172bfc3e2d8b23d name: 'ICMP ping' type: SIMPLE key: icmpping description: | The host accessibility by ICMP ping. 0 - ICMP ping fails; 1 - ICMP ping successful. valuemap: name: 'Service state' tags: - tag: component value: health - tag: component value: network triggers: - uuid: 0c73f37e7ffc4acf83a7edeb84398aba expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0' name: 'Brocade FC: Unavailable by ICMP ping' priority: HIGH description: 'Last three attempts returned timeout. Please check device connectivity.' tags: - tag: scope value: availability - uuid: 4ae37446cb1e4a2d95f55a41dd295bdf name: 'ICMP loss' type: SIMPLE key: icmppingloss value_type: FLOAT units: '%' description: 'The percentage of lost packets.' tags: - tag: component value: health - tag: component value: network triggers: - uuid: eea2256c85764c12b1da83dd8d1a9fe3 expression: 'min(/Brocade FC by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC by SNMP/icmppingloss,5m)<100' name: 'Brocade FC: High ICMP ping loss' opdata: 'Loss: {ITEM.LASTVALUE1}' priority: WARNING description: 'ICMP packets loss detected.' dependencies: - name: 'Brocade FC: Unavailable by ICMP ping' expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 4c8f61f10759487087d5942756f478b2 name: 'ICMP response time' type: SIMPLE key: icmppingsec value_type: FLOAT units: s description: 'The ICMP ping response time (in seconds).' tags: - tag: component value: health - tag: component value: network triggers: - uuid: 17df26093a5f42fdb19715371c85f733 expression: 'avg(/Brocade FC by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}' name: 'Brocade FC: High ICMP ping response time' opdata: 'Value: {ITEM.LASTVALUE1}' priority: WARNING description: 'Average ICMP response time is too high.' dependencies: - name: 'Brocade FC: High ICMP ping loss' expression: 'min(/Brocade FC by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Brocade FC by SNMP/icmppingloss,5m)<100' - name: 'Brocade FC: Unavailable by ICMP ping' expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0' tags: - tag: scope value: availability - tag: scope value: performance - uuid: c7e6790a311c4b4582093cd28341306a name: 'SNMP traps (fallback)' type: SNMP_TRAP key: snmptrap.fallback delay: '0' value_type: LOG trends: '0' description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items' logtimefmt: 'hh:mm:sszyyyy/MM/dd' tags: - tag: component value: network - uuid: 62ae879ca6ab46aebc8655534acbba06 name: 'System contact details' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.4.0]' key: 'system.contact[sysContact.0]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. inventory_link: CONTACT preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system - uuid: b17a06635cb2400f9c6d0f848fd38868 name: 'CPU utilization' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.26.1.0]' key: 'system.cpu.util[swCpuUsage.0]' value_type: FLOAT units: '%' description: | MIB: SW-MIB System's CPU usage. tags: - tag: component value: cpu triggers: - uuid: 68a50684095941cb90f22fbc8d632e7a expression: 'min(/Brocade FC by SNMP/system.cpu.util[swCpuUsage.0],5m)>{$CPU.UTIL.CRIT}' name: 'Brocade FC: High CPU utilization' event_name: 'Brocade FC: High CPU utilization (over {$CPU.UTIL.CRIT}% for 5m)' opdata: 'Current utilization: {ITEM.LASTVALUE1}' priority: WARNING description: 'The CPU utilization is too high. The system might be slow to respond.' tags: - tag: scope value: performance - uuid: 8340ccd92ba940b497375aba810394a4 name: 'System description' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.1.0]' key: 'system.descr[sysDescr.0]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system - uuid: c6e2d4c076b14ed19fbcb08caa32e5be name: 'Firmware version' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.6.0]' key: system.hw.firmware delay: 1h value_type: CHAR trends: '0' description: 'MIB: SW-MIB' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 9c5ae10dbafb45658f25f0279a8a1934 expression: 'last(/Brocade FC by SNMP/system.hw.firmware,#1)<>last(/Brocade FC by SNMP/system.hw.firmware,#2) and length(last(/Brocade FC by SNMP/system.hw.firmware))>0' name: 'Brocade FC: Firmware has changed' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: INFO description: 'Firmware version has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: 3c68a1be050d4c1287e63eb7b3b81f8f name: 'Hardware serial number' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.10.0]' key: system.hw.serialnumber delay: 1h value_type: CHAR trends: '0' description: 'MIB: SW-MIB' inventory_link: SERIALNO_A preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: system triggers: - uuid: 9939f98da99c435a9b5505e55e8abb5f expression: 'last(/Brocade FC by SNMP/system.hw.serialnumber,#1)<>last(/Brocade FC by SNMP/system.hw.serialnumber,#2) and length(last(/Brocade FC by SNMP/system.hw.serialnumber))>0' name: 'Brocade FC: Device has been replaced' event_name: 'Brocade FC: Device has been replaced (new serial number received)' priority: INFO description: 'Device serial number has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - uuid: a988240abba8442da83fdbcb789d0138 name: 'Uptime (hardware)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]' key: 'system.hw.uptime[hrSystemUptime.0]' delay: 30s trends: '0' units: uptime description: | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. preprocessing: - type: CHECK_NOT_SUPPORTED parameters: - '-1' error_handler: CUSTOM_VALUE error_handler_params: '0' - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: system - uuid: 88c5304ddeca47779b76d9806b1edc68 name: 'System location' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.6.0]' key: 'system.location[sysLocation.0]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB Physical location of the node (e.g., `equipment room`, `3rd floor`). If not provided, the value is a zero-length string. inventory_link: LOCATION preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system - uuid: d8d912cb5c924f6587c83f08aa0c8ae1 name: 'System name' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.5.0]' key: system.name delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. inventory_link: NAME preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system triggers: - uuid: 0e624c73fdca490e809ffe9235cda610 expression: 'last(/Brocade FC by SNMP/system.name,#1)<>last(/Brocade FC by SNMP/system.name,#2) and length(last(/Brocade FC by SNMP/system.name))>0' name: 'Brocade FC: System name has changed' event_name: 'Brocade FC: System name has changed (new name: {ITEM.VALUE})' priority: INFO description: 'The name of the system has changed. Acknowledge to close the problem manually.' manual_close: 'YES' tags: - tag: scope value: notice - tag: scope value: security - uuid: 237a5614cb634773853f6d5f42096773 name: 'Uptime (network)' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.3.0]' key: 'system.net.uptime[sysUpTime.0]' delay: 30s trends: '0' units: uptime description: | MIB: SNMPv2-MIB Time (in hundredths of a second) since the network management portion of the system was last re-initialized. preprocessing: - type: MULTIPLIER parameters: - '0.01' tags: - tag: component value: system - uuid: 939c63320b8e4199b87cc4759011da3c name: 'System object ID' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.1.2.0]' key: 'system.objectid[sysObjectID.0]' delay: 15m value_type: CHAR trends: '0' description: | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'. preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 12h tags: - tag: component value: system - uuid: 29f1dda8042d4fd18d7da9eb95fea76c name: 'Overall system health status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.7.0]' key: 'system.status[swOperStatus.0]' delay: 30s trends: '0' description: | MIB: SW-MIB The current operational status of the switch.The states are as follow: online(1) means the switch is accessible by an external Fibre Channel port offline(2) means the switch is not accessible testing(3) means the switch is in a built-in test mode and is not accessible by an external Fibre Channel port faulty(4) means the switch is not operational. valuemap: name: 'SW-MIB::swOperStatus' tags: - tag: component value: system triggers: - uuid: b91af8b94e2047538376be9911beadee expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1' name: 'Brocade FC: System status is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: HIGH description: 'Please check the device for errors' tags: - tag: scope value: availability - tag: scope value: performance - uuid: b17d4a2bae804c968984b763fa4562fc expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"offline\"}")=1 or count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_WARN_STATUS:\"testing\"}")=1' name: 'Brocade FC: System status is in warning state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'Please check the device for warnings' dependencies: - name: 'Brocade FC: System status is in critical state' expression: 'count(/Brocade FC by SNMP/system.status[swOperStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 9a8441cae4fb4c698502a20d5ce23ddf name: 'Memory utilization' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.26.6.0]' key: 'vm.memory.util[swMemUsage.0]' value_type: FLOAT units: '%' description: | MIB: SW-MIB Memory utilization in %. tags: - tag: component value: memory triggers: - uuid: 1991ae08b008488380db02160b15160e expression: 'min(/Brocade FC by SNMP/vm.memory.util[swMemUsage.0],5m)>{$MEMORY.UTIL.MAX}' name: 'Brocade FC: High memory utilization' event_name: 'Brocade FC: High memory utilization (>{$MEMORY.UTIL.MAX}% for 5m)' priority: AVERAGE description: 'The system is running out of free memory.' tags: - tag: scope value: capacity - tag: scope value: performance - uuid: 00b66dbea9464b55bbab004e0eb57c7b name: 'SNMP agent availability' type: INTERNAL key: 'zabbix[host,snmp,available]' description: | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible values: 0 - not available 1 - available 2 - unknown valuemap: name: zabbix.host.available tags: - tag: component value: health - tag: component value: network triggers: - uuid: 1c67a764531b48f1a931a9a928a8708d expression: 'max(/Brocade FC by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' name: 'Brocade FC: No SNMP data collection' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: WARNING description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.' dependencies: - name: 'Brocade FC: Unavailable by ICMP ping' expression: 'max(/Brocade FC by SNMP/icmpping,#3)=0' tags: - tag: scope value: availability discovery_rules: - uuid: 721801e236e34b02b5430d115b23817e name: 'FAN Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1,{#SENSOR_TYPE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2,{#SENSOR_INFO},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5]' key: fan.discovery delay: 1h filter: conditions: - macro: '{#SENSOR_TYPE}' value: '2' formulaid: A item_prototypes: - uuid: 4f37f76d0b3241598e69b091f1835ef5 name: '{#SENSOR_INFO}: Fan speed' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.{#SNMPINDEX}]' key: 'sensor.fan.speed[swSensorValue.{#SNMPINDEX}]' units: rpm description: | MIB: SW-MIB The current value (reading) of the sensor. The value, -2147483648, represents an unknown quantity. The fan value will be in RPM(revolution per minute) tags: - tag: component value: fan - uuid: ee2569161ad146b392bb8f331a7f7d19 name: '{#SENSOR_INFO}: Fan status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.{#SNMPINDEX}]' key: 'sensor.fan.status[swSensorStatus.{#SNMPINDEX}]' delay: 3m trends: '0' description: 'MIB: SW-MIB' valuemap: name: 'SW-MIB::swSensorStatus' tags: - tag: component value: fan trigger_prototypes: - uuid: 75003433a8304644a20d11b82dcbae14 expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' name: 'Brocade FC: {#SENSOR_INFO}: Fan is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the fan unit' tags: - tag: scope value: availability - tag: scope value: performance - uuid: 83e8182fd7034edca8317fa91776b6d2 expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1' name: 'Brocade FC: {#SENSOR_INFO}: Fan is not in normal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the fan unit' dependencies: - name: 'Brocade FC: {#SENSOR_INFO}: Fan is in critical state' expression: 'count(/Brocade FC by SNMP/sensor.fan.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1' tags: - tag: scope value: notice - uuid: 58ece372fefb4881ace97a40c5fb09c2 name: 'Network interfaces discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#IFOPERSTATUS},1.3.6.1.2.1.2.2.1.8,{#IFADMINSTATUS},1.3.6.1.2.1.2.2.1.7,{#IFALIAS},1.3.6.1.2.1.31.1.1.1.18,{#IFNAME},1.3.6.1.2.1.31.1.1.1.1,{#IFDESCR},1.3.6.1.2.1.2.2.1.2,{#IFTYPE},1.3.6.1.2.1.2.2.1.3]' key: net.if.discovery delay: 1h filter: evaltype: AND conditions: - macro: '{#IFADMINSTATUS}' value: '{$NET.IF.IFADMINSTATUS.MATCHES}' formulaid: A - macro: '{#IFADMINSTATUS}' value: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: B - macro: '{#IFALIAS}' value: '{$NET.IF.IFALIAS.MATCHES}' formulaid: C - macro: '{#IFALIAS}' value: '{$NET.IF.IFALIAS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: D - macro: '{#IFDESCR}' value: '{$NET.IF.IFDESCR.MATCHES}' formulaid: E - macro: '{#IFDESCR}' value: '{$NET.IF.IFDESCR.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: F - macro: '{#IFNAME}' value: '{$NET.IF.IFNAME.MATCHES}' formulaid: G - macro: '{#IFNAME}' value: '{$NET.IF.IFNAME.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: H - macro: '{#IFOPERSTATUS}' value: '{$NET.IF.IFOPERSTATUS.MATCHES}' formulaid: I - macro: '{#IFOPERSTATUS}' value: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: J - macro: '{#IFTYPE}' value: '{$NET.IF.IFTYPE.MATCHES}' formulaid: K - macro: '{#IFTYPE}' value: '{$NET.IF.IFTYPE.NOT_MATCHES}' operator: NOT_MATCHES_REGEX formulaid: L description: 'Discovering interfaces from IF-MIB.' item_prototypes: - uuid: a780105f84584ba48acef58f573b5728 name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.13.{#SNMPINDEX}]' key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]' delay: 3m description: | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 04b7026dd1704074b9a18e154d10ef7f name: 'Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.14.{#SNMPINDEX}]' key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]' delay: 3m description: | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: efe5a3957efd4d989809db22ad9cff9d name: 'Interface {#IFNAME}({#IFALIAS}): Bits received' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.6.{#SNMPINDEX}]' key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]' delay: 3m units: bps description: | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' - type: MULTIPLIER parameters: - '8' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: a087793253314286a0bfab36a27898bd name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.19.{#SNMPINDEX}]' key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]' delay: 3m description: | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 67d8b40449a24ad28e31ef0363d8b76d name: 'Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.20.{#SNMPINDEX}]' key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]' delay: 3m description: | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 3c557f4086bc455eb6185878e50b72d9 name: 'Interface {#IFNAME}({#IFALIAS}): Bits sent' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.10.{#SNMPINDEX}]' key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]' delay: 3m units: bps description: | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. preprocessing: - type: CHANGE_PER_SECOND parameters: - '' - type: MULTIPLIER parameters: - '8' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: de0920aa56b740ab89118016cdacbc5e name: 'Interface {#IFNAME}({#IFALIAS}): Speed' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.31.1.1.1.15.{#SNMPINDEX}]' key: 'net.if.speed[ifHighSpeed.{#SNMPINDEX}]' delay: 5m trends: '0' units: bps description: | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero. preprocessing: - type: MULTIPLIER parameters: - '1000000' - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1h tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' - uuid: 1e9a9d3ea4d24922b8c4b7acc20a3c4f name: 'Interface {#IFNAME}({#IFALIAS}): Operational status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.8.{#SNMPINDEX}]' key: 'net.if.status[ifOperStatus.{#SNMPINDEX}]' trends: '0' description: | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. valuemap: name: 'IF-MIB::ifOperStatus' tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: e5391912a6b84c1bb41832e88df4fb96 expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Link down' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: | This trigger expression works as follows: 1. It can be triggered if the operations status is down. 2. `{$IFCONTROL:"{#IFNAME}"}=1` - a user can redefine the context macro to "0", marking this interface as not important. No new trigger will be fired if this interface is down. 3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, does not fire for "eternal off" interfaces.) WARNING: if closed manually - it will not fire again on the next poll, because of .diff. manual_close: 'YES' tags: - tag: scope value: availability - uuid: 391fe664d0e44ed99b2b966c647e1e55 name: 'Interface {#IFNAME}({#IFALIAS}): Interface type' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.2.1.2.2.1.3.{#SNMPINDEX}]' key: 'net.if.type[ifType.{#SNMPINDEX}]' delay: 1h trends: '0' description: | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. valuemap: name: 'IF-MIB::ifType' preprocessing: - type: DISCARD_UNCHANGED_HEARTBEAT parameters: - 1d tags: - tag: component value: network - tag: description value: '{#IFALIAS}' - tag: interface value: '{#IFNAME}' trigger_prototypes: - uuid: 5a98171af6b342ab97e0c6c9de0bd589 expression: | change(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Brocade FC by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) recovery_mode: RECOVERY_EXPRESSION recovery_expression: | (change(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}],#2)>0) or (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2) name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before' opdata: 'Current reported speed: {ITEM.LASTVALUE1}' priority: INFO description: 'This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually.' manual_close: 'YES' dependencies: - name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope value: performance - uuid: a16b52f43a224a11861813be5a11697c expression: | (avg(/Brocade FC by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Brocade FC by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 recovery_mode: RECOVERY_EXPRESSION recovery_expression: | avg(/Brocade FC by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) and avg(/Brocade FC by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)<(({$IF.UTIL.MAX:"{#IFNAME}"}-3)/100)*last(/Brocade FC by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage' event_name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): High bandwidth usage (>{$IF.UTIL.MAX:"{#IFNAME}"}%)' opdata: 'In: {ITEM.LASTVALUE1}, out: {ITEM.LASTVALUE3}, speed: {ITEM.LASTVALUE2}' priority: WARNING description: 'The utilization of the network interface is close to its estimated maximum bandwidth.' manual_close: 'YES' dependencies: - name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope value: performance - uuid: 9f42c5a5ed1341c1a26263642e4dabe4 expression: | min(/Brocade FC by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Brocade FC by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} recovery_mode: RECOVERY_EXPRESSION recovery_expression: | max(/Brocade FC by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 and max(/Brocade FC by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)<{$IF.ERRORS.WARN:"{#IFNAME}"}*0.8 name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): High error rate' event_name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): High error rate (>{$IF.ERRORS.WARN:"{#IFNAME}"} for 5m)' opdata: 'errors in: {ITEM.LASTVALUE1}, errors out: {ITEM.LASTVALUE2}' priority: WARNING description: 'It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.' manual_close: 'YES' dependencies: - name: 'Brocade FC: Interface {#IFNAME}({#IFALIAS}): Link down' expression: '{$IFCONTROL:"{#IFNAME}"}=1 and last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))' recovery_expression: 'last(/Brocade FC by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2 or {$IFCONTROL:"{#IFNAME}"}=0' tags: - tag: scope value: availability - tag: scope value: performance graph_prototypes: - uuid: 0ca148aeaadd45b6bd32e9ecde4127df name: 'Interface {#IFNAME}({#IFALIAS}): Network traffic' graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Brocade FC by SNMP' key: 'net.if.in[ifHCInOctets.{#SNMPINDEX}]' - sortorder: '1' drawtype: BOLD_LINE color: F63100 item: host: 'Brocade FC by SNMP' key: 'net.if.out[ifHCOutOctets.{#SNMPINDEX}]' - sortorder: '2' color: 00611C yaxisside: RIGHT item: host: 'Brocade FC by SNMP' key: 'net.if.out.errors[ifOutErrors.{#SNMPINDEX}]' - sortorder: '3' color: F7941D yaxisside: RIGHT item: host: 'Brocade FC by SNMP' key: 'net.if.in.errors[ifInErrors.{#SNMPINDEX}]' - sortorder: '4' color: FC6EA3 yaxisside: RIGHT item: host: 'Brocade FC by SNMP' key: 'net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]' - sortorder: '5' color: 6C59DC yaxisside: RIGHT item: host: 'Brocade FC by SNMP' key: 'net.if.in.discards[ifInDiscards.{#SNMPINDEX}]' - uuid: 32c9720e348e4d4ebb9e70c2b247de29 name: 'PSU Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1,{#SENSOR_TYPE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2,{#SENSOR_INFO},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5]' key: psu.discovery delay: 1h filter: conditions: - macro: '{#SENSOR_TYPE}' value: '3' formulaid: A item_prototypes: - uuid: 7a8f32cbb43f4ce789097e8cb26b0456 name: '{#SENSOR_INFO}: Power supply status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.{#SNMPINDEX}]' key: 'sensor.psu.status[swSensorStatus.{#SNMPINDEX}]' delay: 3m trends: '0' description: 'MIB: SW-MIB' valuemap: name: 'SW-MIB::swSensorStatus' tags: - tag: component value: power trigger_prototypes: - uuid: 649e7344411242738d9824f861b3c49a expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' name: 'Brocade FC: {#SENSOR_INFO}: Power supply is in critical state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: AVERAGE description: 'Please check the power supply unit for errors' tags: - tag: scope value: availability - tag: scope value: performance - uuid: bfe2f4085f6840da9e8d30f37bb29fdb expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1' name: 'Brocade FC: {#SENSOR_INFO}: Power supply is not in normal state' opdata: 'Current state: {ITEM.LASTVALUE1}' priority: INFO description: 'Please check the power supply unit for errors' dependencies: - name: 'Brocade FC: {#SENSOR_INFO}: Power supply is in critical state' expression: 'count(/Brocade FC by SNMP/sensor.psu.status[swSensorStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1' tags: - tag: scope value: notice - uuid: efaa3e2dfb5b405d99998bd6f8a08697 name: 'Temperature Discovery' type: SNMP_AGENT snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1,{#SENSOR_TYPE},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2,{#SENSOR_INFO},1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5]' key: temperature.discovery delay: 1h filter: conditions: - macro: '{#SENSOR_TYPE}' value: '1' formulaid: A item_prototypes: - uuid: f95f92a4151d4039ab3ce73ca231f079 name: '{#SENSOR_INFO}: Temperature status' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3.{#SNMPINDEX}]' key: 'sensor.temp.status[swSensorStatus.{#SNMPINDEX}]' delay: 3m trends: '0' description: | MIB: SW-MIB Temperature status of testpoint: {#SENSOR_INFO} valuemap: name: 'SW-MIB::swSensorStatus' tags: - tag: component value: temperature - uuid: ee48ef951f124c569327670a2a0f2152 name: '{#SENSOR_INFO}: Temperature' type: SNMP_AGENT snmp_oid: 'get[1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.{#SNMPINDEX}]' key: 'sensor.temp.value[swSensorValue.{#SNMPINDEX}]' delay: 3m value_type: FLOAT units: °C description: | MIB: SW-MIB Temperature readings of testpoint: {#SENSOR_INFO} tags: - tag: component value: temperature trigger_prototypes: - uuid: 5ee4c1931e244d638b58f945f8a7565c expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3' name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above critical threshold' event_name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SENSOR_INFO}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: HIGH description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' tags: - tag: scope value: availability - tag: scope value: performance - uuid: fc68b3a0ea6643f988c26e3e735d7491 expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}' recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'min(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}+3' name: 'Brocade FC: {#SENSOR_INFO}: Temperature is too low' event_name: 'Brocade FC: {#SENSOR_INFO}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SENSOR_INFO}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: AVERAGE tags: - tag: scope value: availability - tag: scope value: performance trigger_prototypes: - uuid: 726afdedb08848bd86ab4161cef29f42 expression: | avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_INFO}"} or last(/Brocade FC by SNMP/sensor.temp.status[swSensorStatus.{#SNMPINDEX}])={$TEMP_WARN_STATUS} recovery_mode: RECOVERY_EXPRESSION recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_INFO}"}-3' name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above warning threshold' event_name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SENSOR_INFO}"}' opdata: 'Current value: {ITEM.LASTVALUE1}' priority: WARNING description: 'This trigger uses temperature sensor values as well as temperature sensor status if available' dependencies: - name: 'Brocade FC: {#SENSOR_INFO}: Temperature is above critical threshold' expression: 'avg(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_INFO}"}' recovery_expression: 'max(/Brocade FC by SNMP/sensor.temp.value[swSensorValue.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_INFO}"}-3' tags: - tag: scope value: availability - tag: scope value: performance tags: - tag: class value: network - tag: target value: brocade - tag: target value: brocade-fc macros: - macro: '{$CPU.UTIL.CRIT}' value: '90' - macro: '{$FAN_CRIT_STATUS}' value: '2' - macro: '{$FAN_OK_STATUS}' value: '4' - macro: '{$HEALTH_CRIT_STATUS}' value: '4' - macro: '{$HEALTH_WARN_STATUS:"offline"}' value: '2' - macro: '{$HEALTH_WARN_STATUS:"testing"}' value: '3' - macro: '{$ICMP_LOSS_WARN}' value: '20' description: 'Warning threshold of ICMP packet loss in %.' - macro: '{$ICMP_RESPONSE_TIME_WARN}' value: '0.15' description: 'Warning threshold of the average ICMP response time in seconds.' - macro: '{$IF.ERRORS.WARN}' value: '2' description: 'Warning threshold of error packet rate. Can be used with interface name as context.' - macro: '{$IF.UTIL.MAX}' value: '90' - macro: '{$IFCONTROL}' value: '1' - macro: '{$MEMORY.UTIL.MAX}' value: '90' - macro: '{$NET.IF.IFADMINSTATUS.MATCHES}' value: '^.*' - macro: '{$NET.IF.IFADMINSTATUS.NOT_MATCHES}' value: ^2$ description: 'Ignore down(2) administrative status' - macro: '{$NET.IF.IFALIAS.MATCHES}' value: '.*' - macro: '{$NET.IF.IFALIAS.NOT_MATCHES}' value: CHANGE_IF_NEEDED - macro: '{$NET.IF.IFDESCR.MATCHES}' value: '.*' - macro: '{$NET.IF.IFDESCR.NOT_MATCHES}' value: CHANGE_IF_NEEDED - macro: '{$NET.IF.IFNAME.MATCHES}' value: '^.*$' - macro: '{$NET.IF.IFNAME.NOT_MATCHES}' value: '(^Software Loopback Interface|^NULL[0-9.]*$|^[Ll]o[0-9.]*$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})' description: 'Filter out loopbacks, nulls, docker veth links and docker0 bridge by default' - macro: '{$NET.IF.IFOPERSTATUS.MATCHES}' value: '^.*$' - macro: '{$NET.IF.IFOPERSTATUS.NOT_MATCHES}' value: ^6$ description: 'Ignore notPresent(6)' - macro: '{$NET.IF.IFTYPE.MATCHES}' value: '.*' - macro: '{$NET.IF.IFTYPE.NOT_MATCHES}' value: CHANGE_IF_NEEDED - macro: '{$PSU_CRIT_STATUS}' value: '2' - macro: '{$PSU_OK_STATUS}' value: '4' - macro: '{$SNMP.TIMEOUT}' value: 5m description: 'Time interval for the SNMP availability trigger.' - macro: '{$TEMP_CRIT}' value: '75' - macro: '{$TEMP_CRIT_LOW}' value: '5' - macro: '{$TEMP_WARN}' value: '65' - macro: '{$TEMP_WARN_STATUS}' value: '5' dashboards: - uuid: 3cf4d180b2a64e938124274ec468491f name: 'Brocade FC: General' pages: - name: 'Brocade FC: General' widgets: - type: graph name: 'Memory utilization' width: '36' height: '5' fields: - type: GRAPH name: graphid.0 value: host: 'Brocade FC by SNMP' name: 'Brocade FC: Memory utilization' - type: STRING name: reference value: AAAAA - type: graph name: 'CPU utilization' x: '36' width: '36' height: '5' fields: - type: GRAPH name: graphid.0 value: host: 'Brocade FC by SNMP' name: 'Brocade FC: CPU utilization' - type: STRING name: reference value: AAAAB valuemaps: - uuid: c8b95f7ce9e44b5ea09273fb6c3c9a28 name: 'IF-MIB::ifOperStatus' mappings: - value: '1' newvalue: up - value: '2' newvalue: down - value: '4' newvalue: unknown - value: '5' newvalue: dormant - value: '6' newvalue: notPresent - value: '7' newvalue: lowerLayerDown - uuid: db55d484980244b4bf5c60e0908f4e9b name: 'IF-MIB::ifType' mappings: - value: '1' newvalue: other - value: '2' newvalue: regular1822 - value: '3' newvalue: hdh1822 - value: '4' newvalue: ddnX25 - value: '5' newvalue: rfc877x25 - value: '6' newvalue: ethernetCsmacd - value: '7' newvalue: iso88023Csmacd - value: '8' newvalue: iso88024TokenBus - value: '9' newvalue: iso88025TokenRing - value: '10' newvalue: iso88026Man - value: '11' newvalue: starLan - value: '12' newvalue: proteon10Mbit - value: '13' newvalue: proteon80Mbit - value: '14' newvalue: hyperchannel - value: '15' newvalue: fddi - value: '16' newvalue: lapb - value: '17' newvalue: sdlc - value: '18' newvalue: ds1 - value: '19' newvalue: e1 - value: '20' newvalue: basicISDN - value: '21' newvalue: primaryISDN - value: '22' newvalue: propPointToPointSerial - value: '23' newvalue: ppp - value: '24' newvalue: softwareLoopback - value: '25' newvalue: eon - value: '26' newvalue: ethernet3Mbit - value: '27' newvalue: nsip - value: '28' newvalue: slip - value: '29' newvalue: ultra - value: '30' newvalue: ds3 - value: '31' newvalue: sip - value: '32' newvalue: frameRelay - value: '33' newvalue: rs232 - value: '34' newvalue: para - value: '35' newvalue: arcnet - value: '36' newvalue: arcnetPlus - value: '37' newvalue: atm - value: '38' newvalue: miox25 - value: '39' newvalue: sonet - value: '40' newvalue: x25ple - value: '41' newvalue: iso88022llc - value: '42' newvalue: localTalk - value: '43' newvalue: smdsDxi - value: '44' newvalue: frameRelayService - value: '45' newvalue: v35 - value: '46' newvalue: hssi - value: '47' newvalue: hippi - value: '48' newvalue: modem - value: '49' newvalue: aal5 - value: '50' newvalue: sonetPath - value: '51' newvalue: sonetVT - value: '52' newvalue: smdsIcip - value: '53' newvalue: propVirtual - value: '54' newvalue: propMultiplexor - value: '55' newvalue: ieee80212 - value: '56' newvalue: fibreChannel - value: '57' newvalue: hippiInterface - value: '58' newvalue: frameRelayInterconnect - value: '59' newvalue: aflane8023 - value: '60' newvalue: aflane8025 - value: '61' newvalue: cctEmul - value: '62' newvalue: fastEther - value: '63' newvalue: isdn - value: '64' newvalue: v11 - value: '65' newvalue: v36 - value: '66' newvalue: g703at64k - value: '67' newvalue: g703at2mb - value: '68' newvalue: qllc - value: '69' newvalue: fastEtherFX - value: '70' newvalue: channel - value: '71' newvalue: ieee80211 - value: '72' newvalue: ibm370parChan - value: '73' newvalue: escon - value: '74' newvalue: dlsw - value: '75' newvalue: isdns - value: '76' newvalue: isdnu - value: '77' newvalue: lapd - value: '78' newvalue: ipSwitch - value: '79' newvalue: rsrb - value: '80' newvalue: atmLogical - value: '81' newvalue: ds0 - value: '82' newvalue: ds0Bundle - value: '83' newvalue: bsc - value: '84' newvalue: async - value: '85' newvalue: cnr - value: '86' newvalue: iso88025Dtr - value: '87' newvalue: eplrs - value: '88' newvalue: arap - value: '89' newvalue: propCnls - value: '90' newvalue: hostPad - value: '91' newvalue: termPad - value: '92' newvalue: frameRelayMPI - value: '93' newvalue: x213 - value: '94' newvalue: adsl - value: '95' newvalue: radsl - value: '96' newvalue: sdsl - value: '97' newvalue: vdsl - value: '98' newvalue: iso88025CRFPInt - value: '99' newvalue: myrinet - value: '100' newvalue: voiceEM - value: '101' newvalue: voiceFXO - value: '102' newvalue: voiceFXS - value: '103' newvalue: voiceEncap - value: '104' newvalue: voiceOverIp - value: '105' newvalue: atmDxi - value: '106' newvalue: atmFuni - value: '107' newvalue: atmIma - value: '108' newvalue: pppMultilinkBundle - value: '109' newvalue: ipOverCdlc - value: '110' newvalue: ipOverClaw - value: '111' newvalue: stackToStack - value: '112' newvalue: virtualIpAddress - value: '113' newvalue: mpc - value: '114' newvalue: ipOverAtm - value: '115' newvalue: iso88025Fiber - value: '116' newvalue: tdlc - value: '117' newvalue: gigabitEthernet - value: '118' newvalue: hdlc - value: '119' newvalue: lapf - value: '120' newvalue: v37 - value: '121' newvalue: x25mlp - value: '122' newvalue: x25huntGroup - value: '123' newvalue: trasnpHdlc - value: '124' newvalue: interleave - value: '125' newvalue: fast - value: '126' newvalue: ip - value: '127' newvalue: docsCableMaclayer - value: '128' newvalue: docsCableDownstream - value: '129' newvalue: docsCableUpstream - value: '130' newvalue: a12MppSwitch - value: '131' newvalue: tunnel - value: '132' newvalue: coffee - value: '133' newvalue: ces - value: '134' newvalue: atmSubInterface - value: '135' newvalue: l2vlan - value: '136' newvalue: l3ipvlan - value: '137' newvalue: l3ipxvlan - value: '138' newvalue: digitalPowerline - value: '139' newvalue: mediaMailOverIp - value: '140' newvalue: dtm - value: '141' newvalue: dcn - value: '142' newvalue: ipForward - value: '143' newvalue: msdsl - value: '144' newvalue: ieee1394 - value: '145' newvalue: if-gsn - value: '146' newvalue: dvbRccMacLayer - value: '147' newvalue: dvbRccDownstream - value: '148' newvalue: dvbRccUpstream - value: '149' newvalue: atmVirtual - value: '150' newvalue: mplsTunnel - value: '151' newvalue: srp - value: '152' newvalue: voiceOverAtm - value: '153' newvalue: voiceOverFrameRelay - value: '154' newvalue: idsl - value: '155' newvalue: compositeLink - value: '156' newvalue: ss7SigLink - value: '157' newvalue: propWirelessP2P - value: '158' newvalue: frForward - value: '159' newvalue: rfc1483 - value: '160' newvalue: usb - value: '161' newvalue: ieee8023adLag - value: '162' newvalue: bgppolicyaccounting - value: '163' newvalue: frf16MfrBundle - value: '164' newvalue: h323Gatekeeper - value: '165' newvalue: h323Proxy - value: '166' newvalue: mpls - value: '167' newvalue: mfSigLink - value: '168' newvalue: hdsl2 - value: '169' newvalue: shdsl - value: '170' newvalue: ds1FDL - value: '171' newvalue: pos - value: '172' newvalue: dvbAsiIn - value: '173' newvalue: dvbAsiOut - value: '174' newvalue: plc - value: '175' newvalue: nfas - value: '176' newvalue: tr008 - value: '177' newvalue: gr303RDT - value: '178' newvalue: gr303IDT - value: '179' newvalue: isup - value: '180' newvalue: propDocsWirelessMaclayer - value: '181' newvalue: propDocsWirelessDownstream - value: '182' newvalue: propDocsWirelessUpstream - value: '183' newvalue: hiperlan2 - value: '184' newvalue: propBWAp2Mp - value: '185' newvalue: sonetOverheadChannel - value: '186' newvalue: digitalWrapperOverheadChannel - value: '187' newvalue: aal2 - value: '188' newvalue: radioMAC - value: '189' newvalue: atmRadio - value: '190' newvalue: imt - value: '191' newvalue: mvl - value: '192' newvalue: reachDSL - value: '193' newvalue: frDlciEndPt - value: '194' newvalue: atmVciEndPt - value: '195' newvalue: opticalChannel - value: '196' newvalue: opticalTransport - value: '197' newvalue: propAtm - value: '198' newvalue: voiceOverCable - value: '199' newvalue: infiniband - value: '200' newvalue: teLink - value: '201' newvalue: q2931 - value: '202' newvalue: virtualTg - value: '203' newvalue: sipTg - value: '204' newvalue: sipSig - value: '205' newvalue: docsCableUpstreamChannel - value: '206' newvalue: econet - value: '207' newvalue: pon155 - value: '208' newvalue: pon622 - value: '209' newvalue: bridge - value: '210' newvalue: linegroup - value: '211' newvalue: voiceEMFGD - value: '212' newvalue: voiceFGDEANA - value: '213' newvalue: voiceDID - value: '214' newvalue: mpegTransport - value: '215' newvalue: sixToFour - value: '216' newvalue: gtp - value: '217' newvalue: pdnEtherLoop1 - value: '218' newvalue: pdnEtherLoop2 - value: '219' newvalue: opticalChannelGroup - value: '220' newvalue: homepna - value: '221' newvalue: gfp - value: '222' newvalue: ciscoISLvlan - value: '223' newvalue: actelisMetaLOOP - value: '224' newvalue: fcipLink - value: '225' newvalue: rpr - value: '226' newvalue: qam - value: '227' newvalue: lmp - value: '228' newvalue: cblVectaStar - value: '229' newvalue: docsCableMCmtsDownstream - value: '230' newvalue: adsl2 - value: '231' newvalue: macSecControlledIF - value: '232' newvalue: macSecUncontrolledIF - value: '233' newvalue: aviciOpticalEther - value: '234' newvalue: atmbond - value: '235' newvalue: voiceFGDOS - value: '236' newvalue: mocaVersion1 - value: '237' newvalue: ieee80216WMAN - value: '238' newvalue: adsl2plus - value: '239' newvalue: dvbRcsMacLayer - value: '240' newvalue: dvbTdm - value: '241' newvalue: dvbRcsTdma - value: '242' newvalue: x86Laps - value: '243' newvalue: wwanPP - value: '244' newvalue: wwanPP2 - value: '245' newvalue: voiceEBS - value: '246' newvalue: ifPwType - value: '247' newvalue: ilan - value: '248' newvalue: pip - value: '249' newvalue: aluELP - value: '250' newvalue: gpon - value: '251' newvalue: vdsl2 - value: '252' newvalue: capwapDot11Profile - value: '253' newvalue: capwapDot11Bss - value: '254' newvalue: capwapWtpVirtualRadio - value: '255' newvalue: bits - value: '256' newvalue: docsCableUpstreamRfPort - value: '257' newvalue: cableDownstreamRfPort - value: '258' newvalue: vmwareVirtualNic - value: '259' newvalue: ieee802154 - value: '260' newvalue: otnOdu - value: '261' newvalue: otnOtu - value: '262' newvalue: ifVfiType - value: '263' newvalue: g9981 - value: '264' newvalue: g9982 - value: '265' newvalue: g9983 - value: '266' newvalue: aluEpon - value: '267' newvalue: aluEponOnu - value: '268' newvalue: aluEponPhysicalUni - value: '269' newvalue: aluEponLogicalLink - value: '270' newvalue: aluGponOnu - value: '271' newvalue: aluGponPhysicalUni - value: '272' newvalue: vmwareNicTeam - value: '277' newvalue: docsOfdmDownstream - value: '278' newvalue: docsOfdmaUpstream - value: '279' newvalue: gfast - value: '280' newvalue: sdci - value: '281' newvalue: xboxWireless - value: '282' newvalue: fastdsl - value: '283' newvalue: docsCableScte55d1FwdOob - value: '284' newvalue: docsCableScte55d1RetOob - value: '285' newvalue: docsCableScte55d2DsOob - value: '286' newvalue: docsCableScte55d2UsOob - value: '287' newvalue: docsCableNdf - value: '288' newvalue: docsCableNdr - value: '289' newvalue: ptm - value: '290' newvalue: ghn - uuid: 17cb6bdbe4244a8fab16c0cbca5a4a00 name: 'Service state' mappings: - value: '0' newvalue: Down - value: '1' newvalue: Up - uuid: 54427fdf694547c598e3662df09a980a name: 'SW-MIB::swOperStatus' mappings: - value: '1' newvalue: online - value: '2' newvalue: offline - value: '3' newvalue: testing - value: '4' newvalue: faulty - uuid: 73618556ee4b4e8f9ec9acf0893e13ea name: 'SW-MIB::swSensorStatus' mappings: - value: '1' newvalue: unknown - value: '2' newvalue: faulty - value: '3' newvalue: below-min - value: '4' newvalue: nominal - value: '5' newvalue: above-max - value: '6' newvalue: absent - uuid: 2fdee7620a3a449f9dd61eb3405e620c name: zabbix.host.available mappings: - value: '0' newvalue: 'not available' - value: '1' newvalue: available - value: '2' newvalue: unknown triggers: - uuid: 42bb10d788484b92ac7290e171ee28a2 expression: '(last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Brocade FC by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Brocade FC by SNMP/system.net.uptime[sysUpTime.0])<10m)' name: 'Brocade FC: Host has been restarted' event_name: 'Brocade FC: {HOST.NAME} has been restarted (uptime < 10m)' priority: WARNING description: 'Uptime is less than 10 minutes.' manual_close: 'YES' dependencies: - name: 'Brocade FC: No SNMP data collection' expression: 'max(/Brocade FC by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0' tags: - tag: scope value: notice graphs: - uuid: 8d1edf299fde462bbca5ceaf1b439223 name: 'Brocade FC: CPU utilization' ymin_type_1: FIXED ymax_type_1: FIXED graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Brocade FC by SNMP' key: 'system.cpu.util[swCpuUsage.0]' - uuid: d1e06bb17c2f458699664bfa61c12496 name: 'Brocade FC: Memory utilization' ymin_type_1: FIXED ymax_type_1: FIXED graph_items: - drawtype: GRADIENT_LINE color: 199C0D item: host: 'Brocade FC by SNMP' key: 'vm.memory.util[swMemUsage.0]'