Backup de templates Zabbix 7.0.31
This commit is contained in:
@@ -0,0 +1,459 @@
|
||||
zabbix_export:
|
||||
version: '7.0'
|
||||
template_groups:
|
||||
- uuid: e960332b3f6c46a1956486d4f3f99fce
|
||||
name: 'Templates/Server hardware'
|
||||
templates:
|
||||
- uuid: cf0947cc05d3450b9a6d66b2eb180482
|
||||
template: 'Supermicro Aten by SNMP'
|
||||
name: 'Supermicro Aten by SNMP'
|
||||
description: |
|
||||
Template Server Supermicro Aten
|
||||
|
||||
MIBs used:
|
||||
HOST-RESOURCES-MIB
|
||||
SNMPv2-MIB
|
||||
ATEN-IPMI-MIB
|
||||
|
||||
Generated by official Zabbix template tool "Templator"
|
||||
vendor:
|
||||
name: Zabbix
|
||||
version: 7.0-2
|
||||
groups:
|
||||
- name: 'Templates/Server hardware'
|
||||
items:
|
||||
- uuid: 7c60cd8613094b95bfd0ad45d04bc0e8
|
||||
name: 'ICMP ping'
|
||||
type: SIMPLE
|
||||
key: icmpping
|
||||
description: |
|
||||
The host accessibility by ICMP ping.
|
||||
|
||||
0 - ICMP ping fails;
|
||||
1 - ICMP ping successful.
|
||||
valuemap:
|
||||
name: 'Service state'
|
||||
tags:
|
||||
- tag: component
|
||||
value: health
|
||||
- tag: component
|
||||
value: network
|
||||
triggers:
|
||||
- uuid: 680c72ab6bb441779553b198081e3bf4
|
||||
expression: 'max(/Supermicro Aten by SNMP/icmpping,#3)=0'
|
||||
name: 'Supermicro Aten: Unavailable by ICMP ping'
|
||||
priority: HIGH
|
||||
description: 'Last three attempts returned timeout. Please check device connectivity.'
|
||||
tags:
|
||||
- tag: scope
|
||||
value: availability
|
||||
- uuid: 4a8bd0d13bab4666aaf4c53b7722ec74
|
||||
name: 'ICMP loss'
|
||||
type: SIMPLE
|
||||
key: icmppingloss
|
||||
value_type: FLOAT
|
||||
units: '%'
|
||||
description: 'The percentage of lost packets.'
|
||||
tags:
|
||||
- tag: component
|
||||
value: health
|
||||
- tag: component
|
||||
value: network
|
||||
triggers:
|
||||
- uuid: e2e4bfca2d0c4f8ebd64bef322d2a368
|
||||
expression: 'min(/Supermicro Aten by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Supermicro Aten by SNMP/icmppingloss,5m)<100'
|
||||
name: 'Supermicro Aten: High ICMP ping loss'
|
||||
opdata: 'Loss: {ITEM.LASTVALUE1}'
|
||||
priority: WARNING
|
||||
description: 'ICMP packets loss detected.'
|
||||
dependencies:
|
||||
- name: 'Supermicro Aten: Unavailable by ICMP ping'
|
||||
expression: 'max(/Supermicro Aten by SNMP/icmpping,#3)=0'
|
||||
tags:
|
||||
- tag: scope
|
||||
value: availability
|
||||
- tag: scope
|
||||
value: performance
|
||||
- uuid: feb1b9189b904b42b17ac4e1db49806e
|
||||
name: 'ICMP response time'
|
||||
type: SIMPLE
|
||||
key: icmppingsec
|
||||
value_type: FLOAT
|
||||
units: s
|
||||
description: 'The ICMP ping response time (in seconds).'
|
||||
tags:
|
||||
- tag: component
|
||||
value: health
|
||||
- tag: component
|
||||
value: network
|
||||
triggers:
|
||||
- uuid: b6fb489c6a624b2994c5e50ba75539b2
|
||||
expression: 'avg(/Supermicro Aten by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}'
|
||||
name: 'Supermicro Aten: High ICMP ping response time'
|
||||
opdata: 'Value: {ITEM.LASTVALUE1}'
|
||||
priority: WARNING
|
||||
description: 'Average ICMP response time is too high.'
|
||||
dependencies:
|
||||
- name: 'Supermicro Aten: High ICMP ping loss'
|
||||
expression: 'min(/Supermicro Aten by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Supermicro Aten by SNMP/icmppingloss,5m)<100'
|
||||
- name: 'Supermicro Aten: Unavailable by ICMP ping'
|
||||
expression: 'max(/Supermicro Aten by SNMP/icmpping,#3)=0'
|
||||
tags:
|
||||
- tag: scope
|
||||
value: availability
|
||||
- tag: scope
|
||||
value: performance
|
||||
- uuid: cadc501d69624baa8ad292c2c8f6fd52
|
||||
name: 'SNMP traps (fallback)'
|
||||
type: SNMP_TRAP
|
||||
key: snmptrap.fallback
|
||||
delay: '0'
|
||||
value_type: LOG
|
||||
trends: '0'
|
||||
description: 'The item is used to collect all SNMP traps unmatched by other snmptrap items'
|
||||
logtimefmt: 'hh:mm:sszyyyy/MM/dd'
|
||||
tags:
|
||||
- tag: component
|
||||
value: network
|
||||
- uuid: ccba865de57a41718b53ff1f82b2ca87
|
||||
name: 'System contact details'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.2.1.1.4.0]'
|
||||
key: 'system.contact[sysContact.0]'
|
||||
delay: 15m
|
||||
value_type: CHAR
|
||||
trends: '0'
|
||||
description: |
|
||||
MIB: SNMPv2-MIB
|
||||
The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.
|
||||
inventory_link: CONTACT
|
||||
preprocessing:
|
||||
- type: DISCARD_UNCHANGED_HEARTBEAT
|
||||
parameters:
|
||||
- 12h
|
||||
tags:
|
||||
- tag: component
|
||||
value: system
|
||||
- uuid: 70f51b4370c64c2bab2c811359ef690b
|
||||
name: 'System description'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.2.1.1.1.0]'
|
||||
key: 'system.descr[sysDescr.0]'
|
||||
delay: 15m
|
||||
value_type: CHAR
|
||||
trends: '0'
|
||||
description: |
|
||||
MIB: SNMPv2-MIB
|
||||
A textual description of the entity. This value should
|
||||
include the full name and version identification of the system's hardware type, software operating-system, and
|
||||
networking software.
|
||||
preprocessing:
|
||||
- type: DISCARD_UNCHANGED_HEARTBEAT
|
||||
parameters:
|
||||
- 12h
|
||||
tags:
|
||||
- tag: component
|
||||
value: system
|
||||
- uuid: 8b0320157a0144a0b2f1d7df7cbbe08a
|
||||
name: 'Uptime (hardware)'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.2.1.25.1.1.0]'
|
||||
key: 'system.hw.uptime[hrSystemUptime.0]'
|
||||
delay: 30s
|
||||
trends: '0'
|
||||
units: uptime
|
||||
description: |
|
||||
MIB: HOST-RESOURCES-MIB
|
||||
The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.
|
||||
preprocessing:
|
||||
- type: CHECK_NOT_SUPPORTED
|
||||
parameters:
|
||||
- '-1'
|
||||
error_handler: CUSTOM_VALUE
|
||||
error_handler_params: '0'
|
||||
- type: MULTIPLIER
|
||||
parameters:
|
||||
- '0.01'
|
||||
tags:
|
||||
- tag: component
|
||||
value: system
|
||||
- uuid: 52169be1d3924c638476a290590066f3
|
||||
name: 'System location'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.2.1.1.6.0]'
|
||||
key: 'system.location[sysLocation.0]'
|
||||
delay: 15m
|
||||
value_type: CHAR
|
||||
trends: '0'
|
||||
description: |
|
||||
MIB: SNMPv2-MIB
|
||||
Physical location of the node (e.g., `equipment room`, `3rd floor`). If not provided, the value is a zero-length string.
|
||||
inventory_link: LOCATION
|
||||
preprocessing:
|
||||
- type: DISCARD_UNCHANGED_HEARTBEAT
|
||||
parameters:
|
||||
- 12h
|
||||
tags:
|
||||
- tag: component
|
||||
value: system
|
||||
- uuid: afa2acff36034dccb96a1946e7039f39
|
||||
name: 'System name'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.2.1.1.5.0]'
|
||||
key: system.name
|
||||
delay: 15m
|
||||
value_type: CHAR
|
||||
trends: '0'
|
||||
description: |
|
||||
MIB: SNMPv2-MIB
|
||||
An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.
|
||||
inventory_link: NAME
|
||||
preprocessing:
|
||||
- type: DISCARD_UNCHANGED_HEARTBEAT
|
||||
parameters:
|
||||
- 12h
|
||||
tags:
|
||||
- tag: component
|
||||
value: system
|
||||
triggers:
|
||||
- uuid: 07b7a49bffea4c03a022eed632754f47
|
||||
expression: 'last(/Supermicro Aten by SNMP/system.name,#1)<>last(/Supermicro Aten by SNMP/system.name,#2) and length(last(/Supermicro Aten by SNMP/system.name))>0'
|
||||
name: 'Supermicro Aten: System name has changed'
|
||||
event_name: 'Supermicro Aten: System name has changed (new name: {ITEM.VALUE})'
|
||||
priority: INFO
|
||||
description: 'The name of the system has changed. Acknowledge to close the problem manually.'
|
||||
manual_close: 'YES'
|
||||
tags:
|
||||
- tag: scope
|
||||
value: notice
|
||||
- tag: scope
|
||||
value: security
|
||||
- uuid: cc33c0e22893432280d642c75020a222
|
||||
name: 'Uptime (network)'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.2.1.1.3.0]'
|
||||
key: 'system.net.uptime[sysUpTime.0]'
|
||||
delay: 30s
|
||||
trends: '0'
|
||||
units: uptime
|
||||
description: |
|
||||
MIB: SNMPv2-MIB
|
||||
Time (in hundredths of a second) since the network management portion of the system was last re-initialized.
|
||||
preprocessing:
|
||||
- type: MULTIPLIER
|
||||
parameters:
|
||||
- '0.01'
|
||||
tags:
|
||||
- tag: component
|
||||
value: system
|
||||
- uuid: a0c0d3ee729b4a159719271232024b45
|
||||
name: 'System object ID'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.2.1.1.2.0]'
|
||||
key: 'system.objectid[sysObjectID.0]'
|
||||
delay: 15m
|
||||
value_type: CHAR
|
||||
trends: '0'
|
||||
description: |
|
||||
MIB: SNMPv2-MIB
|
||||
The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.
|
||||
preprocessing:
|
||||
- type: DISCARD_UNCHANGED_HEARTBEAT
|
||||
parameters:
|
||||
- 12h
|
||||
tags:
|
||||
- tag: component
|
||||
value: system
|
||||
- uuid: e205f1aa96a448a2955e988fa8528600
|
||||
name: 'SNMP agent availability'
|
||||
type: INTERNAL
|
||||
key: 'zabbix[host,snmp,available]'
|
||||
description: |
|
||||
Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.
|
||||
Possible values:
|
||||
0 - not available
|
||||
1 - available
|
||||
2 - unknown
|
||||
valuemap:
|
||||
name: zabbix.host.available
|
||||
tags:
|
||||
- tag: component
|
||||
value: health
|
||||
- tag: component
|
||||
value: network
|
||||
triggers:
|
||||
- uuid: caeb9732846b4ae586ee103ac0c4a65b
|
||||
expression: 'max(/Supermicro Aten by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
|
||||
name: 'Supermicro Aten: No SNMP data collection'
|
||||
opdata: 'Current state: {ITEM.LASTVALUE1}'
|
||||
priority: WARNING
|
||||
description: 'SNMP is not available for polling. Please check device connectivity and SNMP settings.'
|
||||
dependencies:
|
||||
- name: 'Supermicro Aten: Unavailable by ICMP ping'
|
||||
expression: 'max(/Supermicro Aten by SNMP/icmpping,#3)=0'
|
||||
tags:
|
||||
- tag: scope
|
||||
value: availability
|
||||
discovery_rules:
|
||||
- uuid: e31995e21b3942e58b7ed451f57f0360
|
||||
name: 'FAN Discovery'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.21317.1.3.1.2,{#SENSOR_DESCR},1.3.6.1.4.1.21317.1.3.1.13]'
|
||||
key: fan.discovery
|
||||
delay: 1h
|
||||
filter:
|
||||
evaltype: AND
|
||||
conditions:
|
||||
- macro: '{#SENSOR_DESCR}'
|
||||
value: 'FAN.*'
|
||||
formulaid: A
|
||||
- macro: '{#SNMPVALUE}'
|
||||
value: '[1-9]+'
|
||||
formulaid: B
|
||||
description: 'Scanning ATEN-IPMI-MIB::sensorTable with filter: not connected FAN sensors (Value = 0)'
|
||||
item_prototypes:
|
||||
- uuid: 5309e5fab7a44b11a8f045db2868a544
|
||||
name: '{#SENSOR_DESCR}: Fan speed, %'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.4.1.21317.1.3.1.2.{#SNMPINDEX}]'
|
||||
key: 'sensor.fan.speed.percentage[sensorReading.{#SNMPINDEX}]'
|
||||
units: '%'
|
||||
description: |
|
||||
MIB: ATEN-IPMI-MIB
|
||||
A textual string containing information about the interface.
|
||||
This string should include the name of the manufacturer, the product name and the version of the interface hardware/software.
|
||||
tags:
|
||||
- tag: component
|
||||
value: fan
|
||||
- uuid: c03c556ed8e441099513aaacaf4a3752
|
||||
name: 'Temperature Discovery'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'discovery[{#SNMPVALUE},1.3.6.1.4.1.21317.1.3.1.2,{#SENSOR_DESCR},1.3.6.1.4.1.21317.1.3.1.13]'
|
||||
key: tempDescr.discovery
|
||||
delay: 1h
|
||||
filter:
|
||||
evaltype: AND
|
||||
conditions:
|
||||
- macro: '{#SENSOR_DESCR}'
|
||||
value: '.*Temp.*'
|
||||
formulaid: A
|
||||
- macro: '{#SNMPVALUE}'
|
||||
value: '[1-9]+'
|
||||
formulaid: B
|
||||
description: 'Scanning ATEN-IPMI-MIB::sensorTable with filter: not connected temp sensors (Value = 0)'
|
||||
item_prototypes:
|
||||
- uuid: fe3acdb63d884c10bc5abe7edf001ceb
|
||||
name: '{#SENSOR_DESCR}: Temperature'
|
||||
type: SNMP_AGENT
|
||||
snmp_oid: 'get[1.3.6.1.4.1.21317.1.3.1.2.{#SNMPINDEX}]'
|
||||
key: 'sensor.temp.value[sensorReading.{#SNMPINDEX}]'
|
||||
delay: 3m
|
||||
value_type: FLOAT
|
||||
units: °C
|
||||
description: |
|
||||
MIB: ATEN-IPMI-MIB
|
||||
A textual string containing information about the interface.
|
||||
This string should include the name of the manufacturer, the product name and the version of the interface hardware/software.
|
||||
tags:
|
||||
- tag: component
|
||||
value: temperature
|
||||
trigger_prototypes:
|
||||
- uuid: 1a48aee477d54d34bdea47fc6027968c
|
||||
expression: 'avg(/Supermicro Aten by SNMP/sensor.temp.value[sensorReading.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_DESCR}"}'
|
||||
recovery_mode: RECOVERY_EXPRESSION
|
||||
recovery_expression: 'max(/Supermicro Aten by SNMP/sensor.temp.value[sensorReading.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_DESCR}"}-3'
|
||||
name: 'Supermicro Aten: {#SENSOR_DESCR}: Temperature is above critical threshold'
|
||||
event_name: 'Supermicro Aten: {#SENSOR_DESCR}: Temperature is above critical threshold: >{$TEMP_CRIT:"{#SENSOR_DESCR}"}'
|
||||
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
||||
priority: HIGH
|
||||
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
||||
tags:
|
||||
- tag: scope
|
||||
value: availability
|
||||
- tag: scope
|
||||
value: performance
|
||||
- uuid: 2c2914d1c8c846d180ee308fa861540e
|
||||
expression: 'avg(/Supermicro Aten by SNMP/sensor.temp.value[sensorReading.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SENSOR_DESCR}"}'
|
||||
recovery_mode: RECOVERY_EXPRESSION
|
||||
recovery_expression: 'max(/Supermicro Aten by SNMP/sensor.temp.value[sensorReading.{#SNMPINDEX}],5m)<{$TEMP_WARN:"{#SENSOR_DESCR}"}-3'
|
||||
name: 'Supermicro Aten: {#SENSOR_DESCR}: Temperature is above warning threshold'
|
||||
event_name: 'Supermicro Aten: {#SENSOR_DESCR}: Temperature is above warning threshold: >{$TEMP_WARN:"{#SENSOR_DESCR}"}'
|
||||
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
||||
priority: WARNING
|
||||
description: 'This trigger uses temperature sensor values as well as temperature sensor status if available'
|
||||
dependencies:
|
||||
- name: 'Supermicro Aten: {#SENSOR_DESCR}: Temperature is above critical threshold'
|
||||
expression: 'avg(/Supermicro Aten by SNMP/sensor.temp.value[sensorReading.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SENSOR_DESCR}"}'
|
||||
recovery_expression: 'max(/Supermicro Aten by SNMP/sensor.temp.value[sensorReading.{#SNMPINDEX}],5m)<{$TEMP_CRIT:"{#SENSOR_DESCR}"}-3'
|
||||
tags:
|
||||
- tag: scope
|
||||
value: availability
|
||||
- tag: scope
|
||||
value: performance
|
||||
- uuid: 1439e7a34bbf4046836890f208f99a48
|
||||
expression: 'avg(/Supermicro Aten by SNMP/sensor.temp.value[sensorReading.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}'
|
||||
recovery_mode: RECOVERY_EXPRESSION
|
||||
recovery_expression: 'min(/Supermicro Aten by SNMP/sensor.temp.value[sensorReading.{#SNMPINDEX}],5m)>{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}+3'
|
||||
name: 'Supermicro Aten: {#SENSOR_DESCR}: Temperature is too low'
|
||||
event_name: 'Supermicro Aten: {#SENSOR_DESCR}: Temperature is too low: <{$TEMP_CRIT_LOW:"{#SENSOR_DESCR}"}'
|
||||
opdata: 'Current value: {ITEM.LASTVALUE1}'
|
||||
priority: AVERAGE
|
||||
tags:
|
||||
- tag: scope
|
||||
value: availability
|
||||
- tag: scope
|
||||
value: performance
|
||||
tags:
|
||||
- tag: class
|
||||
value: hardware
|
||||
- tag: target
|
||||
value: aten
|
||||
- tag: target
|
||||
value: supermicro
|
||||
macros:
|
||||
- macro: '{$ICMP_LOSS_WARN}'
|
||||
value: '20'
|
||||
description: 'Warning threshold of ICMP packet loss in %.'
|
||||
- macro: '{$ICMP_RESPONSE_TIME_WARN}'
|
||||
value: '0.15'
|
||||
description: 'Warning threshold of the average ICMP response time in seconds.'
|
||||
- macro: '{$SNMP.TIMEOUT}'
|
||||
value: 5m
|
||||
description: 'Time interval for the SNMP availability trigger.'
|
||||
- macro: '{$TEMP_CRIT}'
|
||||
value: '60'
|
||||
- macro: '{$TEMP_CRIT_LOW}'
|
||||
value: '5'
|
||||
- macro: '{$TEMP_WARN}'
|
||||
value: '50'
|
||||
valuemaps:
|
||||
- uuid: e6794dc7602149a3b4fdbfeef45f6e8e
|
||||
name: 'Service state'
|
||||
mappings:
|
||||
- value: '0'
|
||||
newvalue: Down
|
||||
- value: '1'
|
||||
newvalue: Up
|
||||
- uuid: 1fbe26c5dcb3457f98f84a240aa790cd
|
||||
name: zabbix.host.available
|
||||
mappings:
|
||||
- value: '0'
|
||||
newvalue: 'not available'
|
||||
- value: '1'
|
||||
newvalue: available
|
||||
- value: '2'
|
||||
newvalue: unknown
|
||||
triggers:
|
||||
- uuid: 37aab043ea474548ab1e54e504720bed
|
||||
expression: '(last(/Supermicro Aten by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Supermicro Aten by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Supermicro Aten by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Supermicro Aten by SNMP/system.net.uptime[sysUpTime.0])<10m)'
|
||||
name: 'Supermicro Aten: Host has been restarted'
|
||||
event_name: 'Supermicro Aten: {HOST.NAME} has been restarted (uptime < 10m)'
|
||||
priority: WARNING
|
||||
description: 'Uptime is less than 10 minutes.'
|
||||
manual_close: 'YES'
|
||||
dependencies:
|
||||
- name: 'Supermicro Aten: No SNMP data collection'
|
||||
expression: 'max(/Supermicro Aten by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0'
|
||||
tags:
|
||||
- tag: scope
|
||||
value: notice
|
||||
Reference in New Issue